Search PubMed⌕ Search

PubMed · 1917815

Rapid pentachlorophenol evaluation in solid matrixes by second derivative UV spectroscopy for application to wood and leather samples.

Abstract

A method for the quail-quantitative evaluation of pentachlorophenol (PCP) in solid matrixes has been developed. The procedure is based on solid-liquid extraction of solid samples (leather or wood), followed by purification on a cyanopropyl column and determination of the preservative by second derivative UV spectroscopy considering the PCP A peak-through value (304-297 nm). The method allows rapid PCP determination in the concentration range 1-40 micrograms/mL; any matrix interference is avoided by the purification step and recoveries of the preservative were 99.12% (RSD% 0.13) for the leather matrix and 98.03 (RSD% 0.17) for the wood matrix.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Secchieri, C A Benassi, S Pastore, A Semenzato, A Bettero, M Levorato, A Guerrato. Rapid pentachlorophenol evaluation in solid matrixes by second derivative UV spectroscopy for application to wood and leather samples.. https://pubmed.ncbi.nlm.nih.gov/1917815/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Application of a temperature-controllable microreactor to simple and rapid protein identification using MALDI-TOF MS.

We have carried out a simultaneous thermal denaturation and trypsin digestion of proteins using a temperature-controllable microreactor. This is a simple and rapid sample preparation technique for use before matrix-assisted laser desorption ionization time-of-flight mass spectrometry. In contrast to a conventional sample preparation method, which involves several chemical treatments, our sample preparation was performed using only trypsin digestion with the thermal denaturation of the target protein. Optimization of the reactor operational parameters for trypsin digestion using a temperature-controllable microreactor was carried out. The entire trypsin digestion procedure took about 11 min, and consisted of 1 min for the thermal denaturation of the sample protein (3 microl, 0.2 microM) at 85 degrees C, and 10 min for digestion of the protein at 37 degrees C. The resulting sequence coverage ranged from 24% to 57%, which was sufficient for practical protein identification.

Microchemistry↗

Control of droplet size in liquid nanodispensing.

In this Letter, the phenomena and parameters governing the nanoscale dispensing of liquid through an apertured atomic force microscope probe milled by focused ion beam lithography are characterized in detail. We show that the size of deposited droplets can be reproducibly defined by controlling the aperture size on the probe and the surface energies of both tip outer wall and substrate surface. On the basis of these findings, tips with aperture diameter as small as 35 nm enabled the deposition of regular arrays of nanodroplets with diameter down to 70 nm on an alkylamine-modified surface. The fine control of droplet volumes down to a few tens of zeptoliters (10(-21)L) provides a unique tool for creating devices and probing the fundamentals of wetting at the nanometer scale.

Microchemistry↗