A constrained acetabular component for recurrent dislocation.

Abstract

We treated 34 patients with recurrent dislocation of the hip with a constrained acetabular component. Roentgen stereophotogrammetric analysis was performed to assess migration of the prosthesis. The mean clinical follow-up was 3.0 years (2.2 to 4.8) and the radiological follow-up was 2.7 years (2.0 to 4.8). At the latest review six patients had died and none was lost to follow-up. There were four acetabular revisions, three for aseptic loosening and one for deep infection. Another acetabular component was radiologically loose with progressive radiolucent lines in all Gruen zones and was awaiting revision. The overall rate of aseptic loosening was 11.8% (4 of 34). Roentgen stereophotogrammetric analysis in the non-revised components confirmed migration of up to 1.06 mm of translation and 2.32 degrees of rotation at 24 months. There was one case of dislocation and dissociation of the component in the same patient. Of the 34 patients, 33 (97.1%) had no further episodes of dislocation. The constrained acetabular component reported in our study was effective in all but one patient with instability of the hip, but the rate of aseptic loosening was higher than has been reported previously and requires further investigation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R J K Khan, D Fick, R Alakeson, S Haebich, M de Cruz, B Nivbrant, D Wood. 2006. A constrained acetabular component for recurrent dislocation.. https://doi.org/10.1302/0301-620x.88b7.17644

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Corona mortis: an anatomical study with clinical implications in approaches to the pelvis and acetabulum.

The "corona mortis" is an anatomical variant, an anastomosis between the obturator and the external iliac or inferior epigastric arteries or veins. It is located behind the superior pubic ramus at a variable distance from the symphysis pubis (range 40-96 mm). The name "corona mortis" or crown of death testifies to the importance of this feature, as significant hemorrhage may occur if accidentally cut and it is difficult to achieve subsequent hemostasis. It constitutes a hazard for orthopedic surgeons especially in the anterior approach to the acetabulum. We carried out forty cadaver dissections (80 hemi-pelvises) through the ilioinguinal approach. A vascular anastomosis was found in 83% of specimens. Of these, 60% had a large diameter (>3 mm) channel along the posterior aspect of the superior pubic ramus. In clinical practice, however, 492 anterior approaches (to the best of our knowledge the largest series described) have been carried out over the last 15 years by the senior author (MB) and only five of these problematic vessels were discovered, and in only two cases was there troublesome bleeding. This study confirms a paradox: in anatomical dissections a large vessel was identified behind the superior pubic ramus, whereas in clinical practice this vessel does not seem to be as great a threat as initially perceived. Orthopedic surgeons planning an anterior approach to the acetabulum, such as the ilioinguinal or the intrapelvic approach (modified Stoppa), have to be cautious when dissecting near the superior pubic ramus. Despite the high prevalence of these large retropubic vessels in the dissecting room, surgeons should exercise caution but not alter their surgical approach for fear of excessive hemorrhage.

Acetabulum↗

Contact stress assessment of conventional and highly crosslinked ultra high molecular weight polyethylene acetabular liners with finite element analysis and pressure sensitive film.

Stress magnitude and distribution of both conventional polyethylene versus a crosslinked polyethylene in the liner of a total hip replacement (THR) were examined using finite element analysis and pressure sensitive film. Both types of polyethylene were assessed against head sizes of 22 and 28 mm with 5-mm thick polyethylene liners and head sizes of 28, 38, and 46 mm with 3-mm thick polyethylene liners. Liners with 5-mm conventional polyethylene represented successful combinations with long track records. Our hypothesis was that although the combination of the large head and the lower modulus of the highly crosslinked polyethylene would lead to lower stresses, the stresses would be excessive if the liner was extremely thin at 3 mm. Von Mises stresses at the articulating surface of the highly crosslinked liners were lower, when compared to conventional polyethylene, in every THR size examined. Specifically, however, the 38- and 46-mm inner diameter (ID) highly crosslinked polyethylene even at the extreme of only 3-mm thick had lower stresses than the 22-mm ID conventional liner of 5-mm thickness. These data indicate that the use of a large head against highly crosslinked material even at 3-mm thickness results in lower stresses than in an existing conventional 22-mm head and 5-mm thick combination. Obviously, other considerations will influence the minimum thickness to be recommended.

Acetabulum↗

Noninvasive three-dimensional assessment of femoroacetabular impingement.

A CT-based method ("HipMotion") for the noninvasive three-dimensional assessment of femoroacetabular impingement (FAI) was developed, validated, and applied in a clinical pilot study. The method allows for the anatomically based calculation of hip range of motion (ROM), the exact location of the impingement zone, and the simulation of quantified surgical maneuvers for FAI. The accuracy of HipMotion was 0.7 +/- 3.1 degrees in a plastic bone setup and -5.0 +/- 5.6 degrees in a cadaver setup. Reliability and reproducibility were excellent [intraclass correlation coefficient (ICC) > 0.87] for all measures except external rotation (ICC = 0.48). The normal ROM was determined from a cohort of 150 patients and was compared to 31 consecutive hips with FAI. Patients with FAI had a significantly decreased flexion, internal rotation, and abduction in comparison to normal hips (p < 0.001). Normal hip flexion and internal rotation are generally overestimated in a number of orthopedic textbooks. HipMotion is a useful tool for further assessment of impinging hips and for appropriate planning of the necessary amount of surgical intervention, which represents the basis for future computer-assisted treatment of FAI with less invasive surgical approaches, such as hip arthroscopy.

Acetabulum↗