Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Photogrammetry”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

[Assessment of precision and accuracy of digital surface photogrammetry with the DSP 400 system].

The objective of the present study was to evaluate the precision and accuracy of facial anthropometric measurements obtained through digital 3-D surface photogrammetry with the DSP 400 system in comparison to traditional 2-D photogrammetry. Fifty plaster casts of cleft infants were imaged and 21 standard anthropometric measurements were obtained. For precision assessment the measurements were performed twice in a subsample. Accuracy was determined by comparison of direct measurements and indirect 2-D and 3-D image measurements. Precision of digital surface photogrammetry was almost as good as direct anthropometry and clearly better than 2-D photogrammetry. Measurements derived from 3-D images showed better congruence to direct measurements than from 2-D photos. Digital surface photogrammetry with the DSP 400 system is sufficiently precise and accurate for craniofacial anthropometric examinations.

Algorithms↗

3D surface and body documentation in forensic medicine: 3-D/CAD Photogrammetry merged with 3D radiological scanning.

A main goal of forensic medicine is to document and to translate medical findings to a language and/or visualization that is readable and understandable for judicial persons and for medical laymen. Therefore, in addition to classical methods, scientific cutting-edge technologies can and should be used. Through the use of the Forensic, 3-D/CAD-supported Photogrammetric method the documentation of so-called "morphologic fingerprints" has been realized. Forensic, 3-D/CAD-supported Photogrammetry creates morphologic data models of the injury and of the suspected injury-causing instrument allowing the evaluation of a match between the injury and the instrument. In addition to the photogrammetric body surface registration, the radiological documentation provided by a volume scan (i.e., spiral, multi-detector CT, or MRI) registers the sub-surface injury, which is not visible to Photogrammetry. The new, combined method of merging Photogrammetry and Radiology data sets creates the potential to perform many kinds of reconstructions and postprocessing of (patterned) injuries in the realm of forensic medical case work. Using this merging method of colored photogrammetric surface and gray-scale radiological internal documentation, a great step towards a new kind of reality-based, high-tech wound documentation and visualization in forensic medicine is made. The combination of the methods of 3D/CAD Photogrammetry and Radiology has the advantage of being observer-independent, non-subjective, non-invasive, digitally storable over years or decades and even transferable over the web for second opinion.

Autopsy↗

Role of depth in eye distance measurements: comparison of single and stereo-photogrammetry.

Photogrammetry has been used as an alternative to direct measurements to obtain facial distances for a variety of anthropometric applications. Taking measurements from photographs is less intrusive to subjects and reduces screening time, but measurements from single frontal photographs neglect depth information and may be inadequate for screening purposes. This study examined the role of depth in measurements of palpebral fissure length, interpupillary distance, inner canthal distance, and outer canthal distance using single- and stereo-photogrammetry; an operator selected landmarks on single and stereo digital photographs displayed on a computer monitor. Depth was not found to make a significant contribution to eye distances in an idealized system where the real-world coordinates of points on the eye were known from three-dimensional calibration of stereo photographs. However, the differences found between measurements taken from single frontal photographs and those from stereo-photogrammetry indicated that measurements from single photographs are prone to errors due to misalignment of the camera, the face, and the calibration instrument during image acquisition; if single photographs are to be used, the placement of these components should be carefully monitored.

Anthropometry↗

Digital photogrammetry for quantitative wear analysis of retrieved TKA components.

The use of new materials in knee arthroplasty demands a way in which to accurately quantify wear in retrieved components. Methods such as damage scoring, coordinate measurement, and in vivo wear analysis have been used in the past. The limitations in these methods illustrate a need for a different methodology that can accurately quantify wear, which is relatively easy to perform and uses a minimal amount of expensive equipment. Off-the-shelf digital photogrammetry represents a potentially quick and easy alternative to what is readily available. Eighty tibial inserts were visually examined for front and backside wear and digitally photographed in the presence of two calibrated reference fields. All images were segmented (via manual and automated algorithms) using Adobe Photoshop and National Institute of Health ImageJ. Finally, wear was determined using ImageJ and Rhinoceros software. The absolute accuracy of the method and repeatability/reproducibility by different observers were measured in order to determine the uncertainty of wear measurements. To determine if variation in wear measurements was due to implant design, 35 implants of the three most prevalent designs were subjected to retrieval analysis. The overall accuracy of area measurements was 97.8%. The error in automated segmentation was found to be significantly lower than that of manual segmentation. The photogrammetry method was found to be reasonably accurate and repeatable in measuring 2-D areas and applicable to determining wear. There was no significant variation in uncertainty detected among different implant designs. Photogrammetry has a broad range of applicability since it is size- and design-independent. A minimal amount of off-the-shelf equipment is needed for the procedure and no proprietary knowledge of the implant is needed.

Biocompatible Materials↗

Accuracy of a photogrammetry-based patient positioning and monitoring system for radiation therapy.

A photogrammetry system designed to reduce simulator-to-treatment and treatment-to-treatment patient positioning errors has been developed. Two complete systems have been installed in our department: one in the simulator room and one in a treatment room. Each system consists of three charge-coupled device (CCD) cameras; a ring of infrared LEDs around the lens of each camera; and several small, circular, retroreflective markers that are applied to the patient. The markers reflect infrared light directly back to the cameras, producing a binary image of oval hot spots when the image is thresholded. The three-dimensional position of each marker is calculated by conventional photogrammetry methods. At simulation, marker positions are measured, then transferred to the treatment room system. The system may be used to actively position patients, and to passively monitor a patient's position and motion during treatment. Studies have focused on measuring the system's temporal stability, precision, and accuracy; on optimal positioning of markers and cameras; and on assessing the system's capability to reduce the positioning error. The repeatability of measuring a marker's position is <0.1 mm in each orthogonal direction. The accuracy is approximately 0.5 mm over a 40 X 40 X 40 cm3 field of view. The system drift over four hours is approximately +/-0.2 mm. The photogrammetry system has been used to actively position a lead BB, embedded within a head phantom, at the isocenter; repeatability was +/-0.3 mm, as determined radiographically. The system has also been used to passively monitor the positioning of several head and neck patients that were set up by a therapist; setup errors of up to 10 mm in each orthogonal direction were measured, as well as the motion of the patient during treatment.

Humans↗

Digital surface photogrammetry for anthropometric analysis of the cleft infant face.

OBJECTIVE: To analyze the three-dimensional morphology of the cleft infant face with digital surface photogrammetry. DESIGN: Fifty plaster casts of unoperated infants with cleft lip and palate were imaged three-dimensionally with digital surface photogrammetry. Twenty-one standard craniofacial measurements were taken. The plaster casts were divided into 4 groups with unilateral, bilateral, complete, and incomplete clefts of the lip and palate. The measurements were compared with standard values for healthy infants. RESULTS: Significant differences (p < .0025) were found for the alar base width (33% to 55%), the alar base root width (59% to 103%), the width of the nose (7% to 25%), the length of the alar wing (18% to 25%), and the intercanthal (6% to 17%) and biocular (4% to 12%) width, depending on the cleft type. The vertical dimensions of the nose and the upper lip did not differ significantly from the controls. CONCLUSION: This study describes preliminary data on the cleft infant facial deformity. The obtained results were mainly in agreement with data in the limited literature. Three-dimensional photogrammetry has proven to be reliable and can be applied more readily to potentially uncooperative patients.

Cephalometry↗

History of photogrammetry in medicine.

Photogrammetry is one of the many fields of three dimensional measurement associated with surveying. Photogrammetry has been used for medical applications since midway through the nineteenth century, and is now beginning to regain its past popularity due to recent developments in real time instrumentation. Medical photogrammetry, now part of the broader field known as biostereometrics, has had varying popularity over the past one hundred and fifty years due to the many problems encountered during practical applications. This paper will review those applications and explain how technology has been used to overcome many of the problems encountered.

History, 20th Century↗

Analog vs. digital photogrammetry for optic cup analysis.

This report compares the reproducibility of analog and digital photogrammetry for topographical analysis of the optic cup. Ten simultaneous stereophotographs of each of three optic discs were taken with the Zeiss fundus camera plus a twin-prism stereoseparator. Digital processing produced photogrammetric contours of the optic cup and estimates of its geometry. Optic cup contours from the same stereopairs were also drawn with an analog stereoplotter and were analyzed by manual planimetry. The reproducibility of digital photogrammetry and analysis for estimation of cup depth, cup width, cup cross sectional area, and cup volume was concluded to be generally superior to the reproducibility of analog photogrammetry and manual analysis.

Analog-Digital Conversion↗

A comparison of convergent and bi-plane X-ray photogrammetry systems used to detect total joint loosening.

X-ray photogrammetry is an accurate method of measuring structural displacements within the musculoskeletal system. Total joint implant alignment, migration and loosening are important clinical parameters which can be measured by X-ray photogrammetry. The purpose of this paper is to compare two different X-ray photogrammetry systems which are being used to study total joint parameters. The Seattle system uses a convergent geometry and the Cleveland system a bi-plane geometry. The accuracy of the two systems was compared by individually measuring the relative motion produced in an articulated plastic model. The model was designed to simulate the relative motion which can take place between the bone and a loose implant. The displacements of the model components were determined physically and photogrammetrically, and the error in the measurements was calculated for several conditions. Both systems measured relative component motion in the model with a root mean square error of 0.1 mm or less. In clinical use stainless steel markers are implanted in human subjects, and both systems measure distances with a r.m.s. error of 0.2 mm or less. The ease of usage, efficiency and flexibility of the two systems based on actual clinical experience reveals strengths and weaknesses in each which should be recognized when selecting a particular system.

Ankle Joint↗

Combined application of electron backscatter diffraction and stereo-photogrammetry in fractography studies.

The main aim of this paper is to report on recent experimental developments that have succeeded in combining electron back-scatter diffraction (EBSD) with stereo-photogrammetry, compared with two other methods for study of fracture surfaces, namely visual fractography analysis in the scanning electron microscope (SEM) and EBSD directly from facets. These approaches will be illustrated with data relating to the cleavage plane orientation analysis in a ferritic and C-Mn steel. It is demonstrated that the combined use of EBSD and stereo-photogrammetry represents a significant advance in the methodology for facet crystallography analysis. The results of point counting from fractograph characterization determined that the proportions of intergranular fracture in C-Mn and ferritic steels were 10.4% and 9.4%, respectively. The crystallographic orientation was determined directly from the fracture surface of a ferritic steel sample and produced an orientation distribution with a clear trend towards the [001] plane. A stereo-photogrammetry technique was validated using the known geometry of a Vickers hardness indent. The technique was then successfully employed to measure the macroscopic orientation of individual cleavage facets in the same reference frame as the EBSD measurements. Correlating the results of these measurements indicated that the actual crystallographic orientation of every cleavage facet identified in the steel specimens is [001].

Journal Article↗

Simplified photogrammetry of the optic disc.

Simplified photogrammetry of the optic disc depends on axis-correct fundus photography. The evaluation can be initiated by a time-based method of photogrammetry that proves presence or absence of change of the object. The degree of change can be simply measured by a telemetric device that permits one to evaluate the third dimension from stereophotographs.

Humans↗

Geometry of the flagellar motor in the cytoplasmic membrane of Salmonella typhimurium as determined by stereo-photogrammetry of quick-freeze deep-etch replica images.

The precise geometry of the flagellar basal structure anchored in the cytoplasmic membrane was determined by digital stereo-photogrammetry of the images captured by quick-freeze deep-etch replica electron microscopy. In order to examine the structure on the periplasmic side of the membrane, we analyzed the MS ring complexes of Salmonella typhimurium overproduced in the cytoplasmic membrane of Escherichia coli. The rod, the S ring, and the shoulder of the M ring were exposed to the periplasm. On the cytoplasmic side of the membrane, small bumps corresponding to the cytoplasmic rod were discernible. We also examined the intact inner surface of the cells of polyhook mutant which was prepared by a new protocol and found the bell-shaped structure extending from the membrane towards the cytoplasm. It was identified as the C ring, since it was located at the base of the polyhook. Various dimensions of the MS ring complex and the C ring projecting from the membrane were determined by digital stereo-photogrammetry, and a three-dimensional model of the total basal structure is presented.

Cell Membrane↗

Matching tire tracks on the head using forensic photogrammetry.

In the field of the documentation of forensics-relevant injuries, from the reconstructive point of view, the forensic, CAD-supported photogrammetry plays an important role; particularly so when a detailed 3-D reconstruction is vital. This is demonstrated with a soft-tissue injury to the face caused by being run over by a car tire. Since the objects (injury and surface of the tire) to be investigated will be evaluated in virtual space, they must be series photographed. These photo sequences are then evaluated with the RolleiMetric multi-image evaluation system. This system measures and calculates the spatial location of points shown in the photo sequences, and creates 3-D data models of the objects. In a 3-D CAD program, the model of the injury is then compared against the model of the possible injury-causing instrument. The validation of the forensic, CAD-supported photogrammetry, as shown by the perfect 3-D match between the tire tread and the facial injury, demonstrates how greatly this 3-D method surpasses the classic 2-D overlay method (one-to-one photography).

Accidents, Traffic↗

Photogrammetry and conventional impressions for recording implant positions: a comparative laboratory study.

BACKGROUND: The development of digitized techniques for manufacturing implant frameworks has made possible alternative "impression" techniques for recording implant positions. PURPOSE: The objective of the present study was to test the precision and accuracy of a three-dimensional photogrammetric technique to record implant positions in vitro and to compare casts made with this technique with conventional casts fabricated with two conventional impression techniques. MATERIALS AND METHODS: Twenty casts were fabricated from 10 polyether (Impregum, ESPE Dental AG, Seefeld, Germany) impressions and 10 plaster (Kühns Abdrucksgips, Ernst Hirnischs GmbH, Goslar, Germany) impressions of one master model. The casts were measured in a coordinate measuring machine (Zeiss Prismo VAST, Oberkochen, Germany) and compared with the master model. Six separate three-dimensional photographs of the master model were taken with a special camera. After the photographs were measured with an analytic plotter, results were analyzed and compared to the coordinates of the original model and casts. RESULTS: A systematic pattern of distortion in the x-axis was found for the two impression techniques. Expansion of the implant arch at the terminal implants (p < .01) averaged 22 microm and 94 microm on photographs and plaster casts, respectively. Polyether casts contracted an average of 52 microm when compared with the master (p < .01). In absolute figures, photogrammetry and the polyether technique reproduced the x-axis and three-dimensional parameters more accurately than the plaster technique did when cylinder center point distortion was compared (p < .05 to p < .001). However, angular cylinder distortion in absolute figures was greater with the photographic technique than with either of the impression techniques (p < .05-p < .001). CONCLUSION: Photogrammetry is a valid option for recording implant positions and has a precision comparable to that of conventional impression techniques. At present, however, it is limited to framework fabrication techniques that are based on digital platforms.

Calcium Sulfate↗

Optimal marker placement in photogrammetry patient positioning system.

A photogrammetry-based patient positioning system has been used instead of the conventional laser alignment technique for patient set-up in external beam radiotherapy. It tracks skin affixed reflective markers with multiple infrared cameras. The three-dimensional (3D) positions of the markers provide reference information to determine the treatment plan isocenter location and hence provide the ability to position the lesion at the isocenter of the treatment linear accelerator. However, in current clinical practice for lung or liver lesion treatments, fiducial markers are usually randomly affixed onto the patients' chest and abdomen, so that the actual target registration error (TRE) of the internal lesions inside the body may be large, depending on the fiducial registration error (FRE). There exists an optimal marker configuration that can minimize the TRE. In this paper, we developed methods to design the patient-specific optimal configurations of the surface makers to minimize the TRE, given the patient's surface contour, the lesion position and the FRE. Floating genetic algorithm (GA) optimization was used to optimize the positions of the skin markers. The surface curve of the patient body was determined by an automatic segmentation algorithm from the planning CT. The method was evaluated using a body phantom implanted with a metal ball (a simulated target). By registering two CT scans using the surface markers and measuring the displacement of the target, the TRE was measured. The TRE was also measured by taking two orthogonal portal films after positioning the phantom using the photogrammetry based patient positioning system. A 50% reduction in TRE has been achieved by using the optimal configuration compared to the random configuration. This result demonstrates that the optimization of a fiducial configuration can result in improved tumor targeting ability.

Humans↗

Photogrammetry of the muscles of facial expression.

The present study has attempted to determine the volume, square measure as well as length, width and thickness of the individual muscles of facial expression by photogrammetry. 15 fresh male head specimens were employed for a careful dissection of muscle layers. The volume was measured using the immersion procedure. The mean values of each parameter together with the standard deviation were summarized. The results suggest that this novelty in the representation of the mimetic muscles will facilitate the planning of corrective interventions in plastic surgery. Moreover, photogrammetry offers additional information on the required size and measurements of donor muscles.

Aged↗

Digital three-dimensional photogrammetry: evaluation of anthropometric precision and accuracy using a Genex 3D camera system.

OBJECTIVE: To determine the precision and accuracy of facial anthropometric measurements obtained through digital three-dimensional (3D) photogrammetry. DESIGN: Nineteen standard craniofacial measurements were repeatedly obtained on 20 subjects by two independent observers, using calipers and 3D photos (obtained with a Genex 3D camera system), both with and without facial landmarks labeled. Four different precision estimates were then calculated and compared statistically across techniques. In addition, mean measurements from 3D photos were compared statistically with those from direct anthropometry. RESULTS: In terms of measurement precision, the 3D photos were clearly better than direct anthropometry. In almost all cases, the 3D photo with landmarks labeled had the highest overall precision. In addition, labeling landmarks prior to taking measurements improved precision, regardless of method. Good congruence was observed between means derived from the 3D photos and direct anthropometry. Statistically significant differences were noted for seven measurements; however, the magnitude of these differences was often clinically insignificant (< 2 mm). CONCLUSIONS: Digital 3D photogrammetry with the Genex camera system is sufficiently precise and accurate for the anthropometric needs of most medical and craniofacial research designs.

Adolescent↗

The relative skin movement of the foot: a 2-D roentgen photogrammetry study.

OBJECTIVE: This paper describes a validation of the relative motions of skin-mounted markers on the foot. DESIGN: The movement of a skin-mounted marker on the foot was evaluated by the use of 2-D roentgen photogrammetry. BACKGROUND: Validations of skin-mounted markers are needed in order to assess whether clinical use of motion analysis systems is accurate. METHODS: Six healthy volunteers participated in the study. Measurements were made with 2-D roentgen photogrammetry from the medial aspect of the foot. Spherical lead markers, with a diameter of 2 mm, were glued on the skin over the following landmarks: the medial malleolus, the navicular bone, the medial part of calcaneus, the base and the head of the first metatarsal bone, and the base of the fifth metatarsal bone. The foot was placed on a platform that was adjustable in three directions: horizontal, 20 degrees upward (towards dorsal flexion), and 30 degrees downward (towards plantar flexion). RESULTS: In relation to the underlying bones, the markers were found to move up to 4.3 mm. The markers with the largest movements were the ones over the medial malleolus, the navicular bone and the calcaneus. For the distally placed markers i.e. at the base and the head of the first metatarsal bone, and the base of the fifth metatarsal bone, the displacements were a maximum 1.8 mm. CONCLUSIONS: Markers mounted on the foot moved between 1.8 and 4.3 mm corresponding to the underlying bones. The most proximal attached markers demonstrated the largest movements.

Journal Article↗