Search PubMed⌕ Search

PubMed · 15310651

Internal or external diameter?

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tiberiu Ezri, Marian Weissenberg, Ofer Yanai, Michael Sullam-Muggia, Zion Houri, Peter Szmuk. Internal or external diameter?. https://doi.org/10.1007/bf03018441

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of surfactant deficiency and surfactant replacement on airway patency in the piglet lung.

We investigated the effect of surfactant deficiency on airway patency and the effectiveness of surfactant replacement as either an instilled liquid bolus, a non-hygroscopic aerosol or a hygroscopic aerosol. Small airway patency was assessed in isolated piglet lungs by passing a continuous flow of gas though a cannulated airway. Occlusion was assessed by measuring increases in pressure in the cannula that resulted from airway obstruction. In surfactant-deficient conditions the amount of airway closure increased approximately three-fold. However, administration of exogenous surfactant as an instilled liquid bolus, non-hygroscopic aerosol or a hygroscopic aerosol decreased airway closure such that it was statistically similar to that recorded prior to induction of surfactant deficiency, although the instilled and hygroscopic aerosol surfactant both appeared superior to the non-hygroscopic aerosol. These experiments showed that pulmonary surfactant does have a role in maintaining airway patency and that airway closure induced by surfactant deficiency could be reduced by administration of surfactant in any of the aforementioned forms.

Airway Resistance↗

Clinical applications of forced oscillation to assess peripheral airway function.

Forced oscillation applies external pressures to the respiratory system to measure respiratory impedance. Impedance of larger central airways may be dissected from that of peripheral airways using multiple oscillation frequencies. Respiratory impedance is calculated by computer-assisted methods that yield separate resistive and reactive components. The reactive component includes respiratory system capacitative and inertive properties, which may be separately visualized for clinical purposes using resonance as a rough dividing line. Low oscillation frequencies comprise those below resonance, and relate most prominently to capacitative properties of peripheral airways. High oscillation frequencies comprise those greater than resonance, which relate most prominently to inertial properties of larger central airways. Measurements of resistance and reactance in patients with peripheral airway disease, before and after therapeutic intervention, manifest characteristic patterns of response in low frequency resistance and reactance measures that appear to be closely correlated with each other. In contrast, changes in large central airways manifest resistance change uniformly over low and high frequencies.

Airway Resistance↗

Evaluation of respiratory function by barometric whole-body plethysmography in healthy dogs.

The objective of the present study was to assess the validity of barometric whole-body plethysmography (BWBP), to establish reference values, and to standardise a bronchoprovocative test to investigate airway responsiveness using BWBP in healthy dogs. BWBP measurements were obtained from six healthy beagle dogs using different protocols: (1) during three consecutive periods (3.5min each) in two morning and two evening sessions; (2) before and after administration of two protocols of sedation; (3) before and after nebulisation of saline and increasing concentrations of carbachol and histamine both in conscious dogs and in dogs under both protocols of sedation. Enhanced pause (PENH) was used as index of bronchoconstriction. Basal BWBP measurements were also obtained in 22 healthy dogs of different breeds, age and weight. No significant influence of either time spent in the chamber or daytime was found for most respiratory variables but a significant dog effect was detected for most variables. A significant body weight effect was found on tidal volume and peak flow values (P<0.05). Response to carbachol was not reproducible and always associated with side effects. Nebulisation of histamine induced a significant increase in respiratory rate, peak expiratory flow, peak expiratory flow/peak inspiratory flow ratio and PENH (P<0.05). The response was reproduced in each dog at different concentrations of histamine. Sedation with acepromazine+buprenorphine had little influence on basal measurements and did not change the results of histamine challenge. It was concluded that BWBP is a safe, non invasive and reliable technique of investigation of lung function in dogs which provides new opportunities to characterise respiratory status, to evaluate airway hyperresponsiveness and to assess therapeutic interventions.

Airway Resistance↗