Search PubMed⌕ Search

Biomedical subjects

Peter Szmuk

Publications and source records attributed to Peter Szmuk.

16 recordsLinked to original sources

Phosphate salt bowel preparation regimens alter perioperative acid-base and electrolyte balance.

BACKGROUND: Hyperphosphatemic acidosis and severe electrolyte disturbances caused by phosphate salts (PO) used for mechanical bowel preparation have been described in occasional case reports prior to bowel resection surgery. We hypothesized that PO used preoperatively for bowel preparation may cause more pronounced acid base and electrolyte changes than polyethylene glycol (PG). METHODS: Forty American Society of Anesthesiologists physical status II-III patients were randomly allocated to receive either PO or PG for bowel preparation before intra-abdominal surgery (bowel resection or other major elective intra-abdominal surgeries). Measurements of pH, base deficit, blood gases, lactate, hemoglobin, calcium, magnesium, potassium and phosphorus were undertaken before the laxative administration, intraoperatively, and postoperatively. RESULTS: Preoperative demographic, hemodynamic and laboratory data were similar in the two groups. Intraoperative calcium (8.4 [0.6] vs 9 [0.5] mg x dL(-1)) and pH (7.35 [0.04] vs 7.41 [0.03]) were lower, while lactate (1.3 [0.4] vs 0.9 [0.3] mmol x L(-1)) was higher with PO. Postoperative calcium, magnesium and potassium were lower (8 [0.5] vs 8.9 [0.2] mg x dL(-1), 1.68 [0.3] vs 1.8 [0.4] and 3.5 [0.36] vs 3.7 [0.33] mEq x L(-1) respectively) while phosphorus (4.1 [0.3] vs 3.3 [0.2] mEq x L(-1)) was higher with PO. A higher percentage of abnormal values for calcium, potassium, phosphorus and base deficit (66% vs 33%, 25% vs 10%, 19% vs 2% and 28.3% vs 5% respectively) were observed with PO. CONCLUSIONS: Calcium and magnesium changes were more pronounced in patients who received PO for bowel preparation.

Abdomen↗

Use of CobraPLA for airway management in a neonate with Desbuquois syndrome. Case report and anesthetic implications.

We present the anesthetic management of an infant with Desbuquois syndrome (a rare form of micromelic dwarfism) with a possible difficult airway. The anesthetic implications of this syndrome are presented. The airway was managed with a new supraglottic device - the CobraPLA. Although intubation through this device was not possible in this instance, CobraPLA provided a satisfactory supraglottic airway. It was easy to insert and provided satisfactory conditions for positive pressure ventilation. The CobraPLA provides another option for airway management.

Abnormalities, Multiple↗

Nasal versus oral fiberoptic intubation via a cuffed oropharyngeal airway (COPA) during spontaneous ventilation.

STUDY OBJECTIVE: To compare the success rate of nasal versus oral fiberoptic intubation in anesthetized patients breathing spontaneously via the cuffed oropharyngeal airway (COPAtrade mark). DESIGN: Prospective, randomized, controlled study. SETTING: Two university-affiliated hospitals. PATIENTS: Patients scheduled for general or plastic surgery of the torso or extremities. INTERVENTIONS: Nasal (n=20) and oral (n=20) fiberoptic intubation were performed in patients while breathing spontaneously via the COPA during standardized anesthesia. MEASUREMENTS: Demographic data, mean arterial pressure, heart rate, end-tidal carbon dioxide (ETCO2), oxygen saturation (SpO2), COPA size, difficult airway predictors, rate of failed ventilation via COPA, and frequency of hypoxemia (SpO2 < 90%) during the procedure, and perioperative untoward events were recorded. MAIN RESULTS: The background, airway difficulty, vital signs and untoward effects were similar in the two groups. Nasal fiberoptic laryngeal view (scale 1-4) was better than the oral grading (3 [median] vs. 2, respectively; p <0.05). Eighty percent of the nasal intubations were successful compared with 40% of the oral intubations (p <0.05). Nasal intubations were accomplished within 153 +/- 15 SD seconds compared with 236 +/- 22 seconds (p <0.05) for the oral intubations, and less propofol was needed in the nasal intubations during the procedures (240 +/- 27 mg [nasal] vs. 277+/- 39 mg [oral]; p <0.05). CONCLUSIONS: Nasal fiberoptic laryngoscopy is more successful and easy than the oral approach in anesthetized patients who are breathing spontaneously through the COPA.

Administration, Inhalation↗

Increased body mass index per se is not a predictor of difficult laryngoscopy.

PURPOSE: We investigated the association between morbid obesity and difficult laryngoscopy (DL). METHODS: In a prospective, controlled study we evaluated the impact of different variables on the prediction of DL in 200 morbidly obese (study group-SG), and 1272 non-obese (control group-CG) patients undergoing elective surgery. Variables assessed included age, sex, body mass index (BMI), protruding, loose, and missing upper teeth, thyro-mental distance, temporo-mandibular joint (TMJ) function, neck extension, and Mallampati class. A Cormack grade III or IV was considered DL. RESULTS: The SG patients were younger (P < 0.000), there were more females in the SG (P < 0.000) and more in the SG had teeth problems (P = 0.026). More patients in the SG (10% vs 1%), had obstructive sleep apnea (P < 0.001) with 90% of them in the SG having a grade III laryngoscopy. High BMI did not affect the laryngoscopy difficulty (P = 0.56). Multivariable regression analysis revealed that morbid obesity, increased age, male sex, pathology of TMJ, and higher Mallampati class, were independent predictors of DL. When interaction between the predictors and the group was added to the multivariable model, the SG was no longer a predictor by itself, rather its association with abnormal upper teeth turned to be significant for prediction of DL. CONCLUSIONS: Increased age, male sex, TMJ pathology, Mallampati 3 and 4, a history of obstructive sleep apnea and abnormal upper teeth were associated with a higher incidence of DL. The magnitude of BMI had no influence on difficulty with laryngoscopy.

Adult↗

Difficult airway management practice patterns among anesthesiologists practicing in the United States: have we made any progress?

STUDY OBJECTIVE: To determine the extent instruction and practice in the use of airway devices and techniques varies among anesthesiologists practicing in the United States. DESIGN: Survey questionnaire. SETTING: University medical center. MEASUREMENTS: Questionnaires were completed by American-trained anesthesiologists who attended the 1999 American Society of Anesthesiologists (ASA) Annual Meeting. Data collected included demographics, education, skills with airway devices/techniques, management of clinical difficult airway scenarios, and the use of the ASA Difficult Airway Algorithm. MAIN RESULTS: 1) DEMOGRAPHICS: 452 questionnaires were correctly completed; 62% attending anesthesiologists, 70% <50 years, 81% males, 44% from academic institutions, 63% >10 years of practice, 81% night duty, 77% board certified. 2) Education: 71% had at least one educational modality: difficult airway rotation, workshops, conferences, books, and simulators. 3) Skills: Miller blade 61%, Bullard laryngoscope 32%, LMA 86%, Combitube 43%, bougie 43%, exchangers 47%, cuffed oropharyngeal airway (COPA) 34%, retrograde 41%, transtracheal needle jet ventilation 34%, cricothyrotomy 21%, fiberoptics 59%, and blind nasal intubation 78%. The average reported use of special airway devices/techniques was 47.5%. 4) Management choices: failed intubation/ventilation: LMA (81%) and for all other situations: fiberoptic intubation. Use of ASA Difficult Airway Algorithm in clinical practice (86%). CONCLUSION: Fiberoptic intubation and the LMA are most popular in management of the difficult airway.

Anesthesia, Conduction↗

Anaesthesia for magnetoencephalography in children with intractable seizures.

BACKGROUND: Magnetoencephalography (MEG), a noninvasive technique for evaluation of epileptic patients, records magnetic fields during neuronal electrical activity within the brain. Anaesthesia experience for MEG has not yet been reported. METHODS: We retrospectively reviewed records of 48 paediatric patients undergoing MEG under anaesthesia. Thirty-one patients (nonprotocol group) were managed according to the anaesthesiologist's discretion. Premedication included oral midazolam, chloral hydrate or fentanyl oralet, intravenous midazolam or inhalational anaesthesia with sevoflurane. Anaesthesia was maintained with propofol, midazolam, fentanyl, alone or in combination. A subsequent protocol group (17 patients) received chloral hydrate as premedication and propofol for maintenance of anaesthesia. RESULTS: There was an overall 25% failure of interictal activity and localization on the MEG scan. In the nonprotocol group, 11 scans failed (35.5%). Of these, eight (72.7%) received midazolam orally. Only one failure (5.8%) was recorded in the protocol group in a patient who received chloral hydrate as sedation supplemented by sevoflurane. CONCLUSIONS: In our experience, midazolam premedication resulted in a high MEG failure rate (73%). Chloral hydrate premedication and propofol maintenance resulted in a lower incidence of MEG failure (5.8%). General anaesthesia with a continuous infusion of propofol or sevoflurane appears acceptable, although, lighter levels of anaesthesia might be required to avoid interference with interictal activity of the brain.

Anesthesia, General↗

The endotracheal tube moves more often in obese patients undergoing laparoscopy compared with open abdominal surgery.

UNLABELLED: We compared the incidence of movements of the endotracheal tube (ETT) within the trachea in morbidly obese patients undergoing either laparoscopic or open gastroplasty. In a double-blinded, prospective, controlled study, 60 patients (body mass index, 35-60 kg/m(2)) were equally allocated to either laparoscopic LapBand gastroplasty (study group; Group 1) or open laparotomy gastroplasty (control; Group 2), both under standardized general anesthesia. Movements of the ETT were assessed with chest auscultation, peak inspiratory pressure, ETCO(2), SpO(2), and the Rapiscope at predetermined time points: after intubation (baseline values), 5 min before peritoneal inflation in Group 1 and 10 min postintubation in Group 2, at maximal abdominal inflation in Group 1 and 20 min into the procedure in Group 2, 5 min before and 5 min after changing the patient's position from neutral to 10 degrees head up and 10 degrees head down in Group 1 and 30 and 40 min into the procedure in Group 2, 2 min after abdominal deflation and table repositioning in Group 1 and at 50 min in Group 2, and just before extubation in both groups. Twenty-one events of ETT tip movement occurred in both groups. The tube moved in 15 (50%) study (laparoscopy) group patients compared with 6 (20%) controls (laparotomy; P < 0.05), 12 of the former having moved downward either after maximal abdominal insufflation or in association with head-down positioning. The tubes of five study group patients (17%) advanced into the right bronchus, compared with none in the controls (P < 0.05). All changes in position were rectified only by the Rapiscope. IMPLICATIONS: Abdominal insufflation and changes in table position lead to more frequent movements of the endotracheal tube in obese patients undergoing laparoscopic versus open gastroplasty. The Rapiscope identifies all these changes, but not the clinically available variables.

Abdomen↗

The effects of hydration on core temperature in pediatric surgical patients.

BACKGROUND: Reduced vascular volume might influence body temperature by diverting heat flow from peripheral tissues to the central organs. We therefore tested the hypothesis that mild hypovolemia helps to prevent intraoperative hypothermia in pediatric patients. METHODS: Twenty-two pediatric patients (aged 1-3 yr) undergoing prolonged minor surgery were randomly assigned to conservative (n = 12) or aggressive (n = 10) perioperative fluid management. The conservative group fasted 8 h before surgery and received a crystalloid at 1 ml. kg-1. h-1 during surgery. The aggressive group was allowed to drink liquids until 3 h before surgery and was given a maintenance crystalloid at 8 ml. kg-1. h-1. Anesthesia was induced and maintained with halothane in nitrous oxide. Ambient temperature was kept near 25 degrees C, but the patients were not actively warmed. During recovery from anesthesia, additional fluid was given to the conservative group so that perioperative fluid totaled 9.5 ml. kg-1. h-1 in both groups. RESULTS: Intraoperative body weight remained unchanged in the aggressive group and decreased only 1% in patients managed conservatively. Heart rate was slightly greater in the conservative group (107 +/- 9 vs. 95 +/- 4 beats/min, P = 0.002), but blood pressure was similar. Esophageal temperature in patients whose fluid was managed conservatively increased significantly, by 0.4 +/- 0.3 degrees C, to 37.1 degrees C; in contrast, temperature in the aggressive group decreased significantly, by 0.4 +/- 0.2 degrees C, to 36.4 degrees C (P < 0.001 between groups). Temperatures remained significantly different 1 h after surgery. CONCLUSIONS: Conservative fluid management, which decreased body weight by only 1%, prevented reduction in core body temperature, presumably by reducing dissipation of metabolic heat from the core thermal compartment to peripheral tissues.

Anesthesia↗

Endotracheal intubation with a gum-elastic bougie in unanticipated difficult direct laryngoscopy: comparison of a blind technique versus indirect laryngoscopy with a laryngeal mirror.

UNLABELLED: We evaluated the efficacy of intubation over a gum-elastic bougie by using either a blind technique or indirect laryngoscopy with a laryngeal mirror in patients with unexpected difficult direct laryngoscopy. In a prospective study, 60 consecutive patients with an unexpected Grade III or IV direct laryngoscopy were randomly allocated for intubation with a gum-elastic bougie either blindly (Group 1) or by indirect laryngoscopy with a laryngeal mirror (Group 2). We evaluated the failure rate of each method of intubation, complications related to either method, and the time required for intubation. Out of 725 patients evaluated over a 2-mo period, 60 patients (8.3%) had a Grade III laryngoscopy, and 30 of these were randomized into each group. There were 8 failed intubations in Group 1 compared with 1 failed intubation in Group 2 (P < 0.05). All eight failures in the blind intubation group ended with esophageal intubation. No additional complications were noted in either group. The time required for endotracheal intubation with each group was not significantly different (45 +/- 10 s versus 44 +/- 11 s). We conclude that intubation with a gum-elastic bougie had a lower failure rate using indirect laryngoscopy with a laryngeal mirror than a traditional blind technique. IMPLICATIONS: We evaluated the efficacy of intubation over a gum-elastic bougie by using either a blind technique or a laryngeal mirror. Intubation with a gum-elastic bougie had a lower failure rate using indirect laryngoscopy with a laryngeal mirror (P < 0.05) than a traditional blind technique.

Aged↗