Search PubMed⌕ Search

PubMed · 14807380

[Optic coordinates vertigo].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L HALPERN. 1950. [Optic coordinates vertigo].. https://doi.org/10.1159/000300904

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Location of glaucoma drainage devices relative to the optic nerve.

BACKGROUND: Limited data are available to guide optimal positioning of glaucoma drainage devices (GDD) in relation to the limbus and optic nerve. The authors aim to provide guidelines for appropriate and safe GDD implantation. METHOD: The optimal positioning of five different GDD were evaluated using necropsy eyes of varying axial lengths. The dependent variable that was measured was the maximum distance that a GDD could be placed posterior to the limbus while remaining 2 mm away from the optic nerve. RESULTS: The average maximum distance posterior to the limbus of the anterior plate edge ranged between 9.0-15.0 mm in the superotemporal quadrant for the GDD tested. The distances for superonasal, inferonasal, and inferotemporal quadrants ranged between 8.0-14.0 mm, 9.0-14.0 mm, and 11.0-17.0 mm, respectively. The Molteno device could be placed most posteriorly while remaining 2 mm away from the nerve. The Ahmed FP7 and S2 were the least amenable to posterior placement before encroaching on the 2 mm limit. CONCLUSION: The maximum distance that a GDD can be placed posterior to the limbus, before encroachment around the optic nerve, varies between different devices and quadrants of placement. Taking a measurement of the exact distance of the plate from the limbus during GDD surgery is recommended.

Eye↗

High-resolution MR imaging of the human eye 2005.

RATIONALE AND OBJECTIVES: We studied preparatory strategies for high-resolution human eye in vivo imaging with commercially available magnets and coils. MATERIALS AND METHODS: We imaged normal volunteers on 1.5T systems by Philips, GE, and Siemens, using commercial approximately 9 cm temporomandibular joint receive coils. Subjects fixated the nonimaged eye on a target. We compared signal (S) to tissue noise (Nt) and system noise (Ns) between images acquired with the imaged eye: 1) open, 2) held closed, 3) taped closed, and 4) taped closed with overlying water-soaked gauze. We standardized technique 4 to compare studies between manufacturers using T1-weighted parameters (repetition time/echo time/flip angle/number of signal averages = 400 ms/10-17 ms/90 degrees /4-6, in-plane resolution approximately 250 x 250 microm2; 2-3 mm slices, image time = 4.3-5.2 min). We obtained similar images of an enucleated human eye to estimate in vivo effects of microsaccades and ocular pulsations. RESULTS: Measurements of S/Nt and S/Ns gave surprising results of Nt < Ns in some instances. Ns/Nt was congruent with 1, varying approximately 20%, when the eye was taped shut and covered with water-soaked gauze. T1-weighted spin echo sequences, using technique 4, produced high-quality images with good S/Nt on all systems. Images from the three manufacturers were comparable when parameters were normalized for pulse repetition time, echo time, number of signal averages, bandwidth in Hz/pixel, and reconstruction matrix. Images of the enucleated eye produced S/Nt ratios that were comparable to in vivo images in some structures. CONCLUSIONS: Our best preparatory technique produced images with in-plane resolution of approximately 250 mum in 4-5 minutes with three commercial 1.5 T systems. The in vivo S/Nt was comparable to in vitro values in most solid tissues but decreased in most fluid compartments.

Eye↗