Search PubMed⌕ Search

PubMed · 14674792

A sampling method for comparing fungal concentrations in carpets.

Abstract

A microvacuum method is described for sampling fungal contaminants in carpet dust and reporting the results on an area basis. When sampling parameters such as suction force, contact time, and area sampled were held constant, and the results were reported on an area basis, fungal concentrations were associated with the potential for water intrusion, a determinant of exposure. Carpet dust samples were collected in open-face 25-mm cassettes containing 0.8 micro m mixed cellulose ester filters. The airflow rate was calibrated at 10 L/min, and the open-faced cassette was held firmly against the carpet at 20 separate spots for a period of 5 sec at each spot. An area of 98 cm(2) of carpet was sampled with each cassette. A total of 58 carpet dust samples were collected in 31 residential condominium units using the described methodology. The carpets were stratified into three groups: (1) controls and those at centers of rooms, (2) at sliding glass doors and under windows, and (3) in areas of water intrusion reported by the occupant. The geometric mean concentrations (GM) of total fungi increased in the listed order, as did the GM concentrations of Penicillium spp. and Aspergillus spp. detected in the samples. In addition, the 95% confidence intervals on the GM concentrations for total fungi could be used to classify the carpets into three groups: uncontaminated, potentially contaminated, and contaminated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Joe C Spurgeon. A sampling method for comparing fungal concentrations in carpets.. https://doi.org/10.1202/429.1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Pilot study of indoor radon in Greek workplaces.

Radon and gamma dose rate measurements have been performed in 561 workplaces in 19 prefectures of Greece. The distribution of radon concentration can be well described by a log-normal distribution. Most of the radon concentrations are between 50 and 200 Bq m(-3) with an arithmetic mean of 123 Bq m(-3). The maximum measured value of radon gas concentration is 695 Bq m(-3). About 10% of the workplaces exceed 200 Bq m(-3). Only a small fraction ( approximately 1%) of workplaces exceed the European Commission action level (400 Bq m(-3)). Despite the relative small fraction of workplaces which exceed the value of 400 Bq m(-3), it is clear from the results of the present work that for certain prefectures, further and more extensive research is needed.

Air Pollution, Indoor↗

Health effects of arsenic, fluorine, and selenium from indoor burning of Chinese coal.

China's economy has developed rapidly in the last two decades, leading to an increase in energy consumption and consequently emissions from energy generation. Coal is a primary energy source in China because of its abundance and will continue to be used in the future. The dominance of coal in energy production is expected to result in increasing levels of exposure to environmental pollution in China. Toxic trace elements emitted during coal combustion are the main sources of indoor air pollution. They are released into the atmosphere mainly in the forms of fine ash and vapors and have the potential to adversely affect human health. Those trace elements, which volatilize during combustion, are hazardous air pollutants (HAPs) and are particularly rich in Chinese coals. Among the HAPs, arsenic (As), fluorine (F), and selenium (Se) have already been identified as pollutants that can induce severe health problems. In this review, the geochemical characteristics of As, F, and Se, including their concentration, distribution, and mode of occurrences in Chinese coal, are documented and discussed. Our investigations have confirmed the current As- and F-induced epidemics in Guizhou (Southwest China) and Se epidemic in Hubei (Northeast China). In this study, diagnostic symptoms of arseniasis, fluorosis, and selenosis are also illustrated.

Air Pollution, Indoor↗