Search PubMed⌕ Search

PubMed · 12198843

Method based on solid-phase microextraction--high-performance liquid chromatography with UV and electrochemical detection to determine estrogenic compounds in water samples.

Abstract

We determined a group of estrogenic compounds by solid-phase microextraction (SPME) coupled to high-performance liquid chromatography (HPLC) with both ultraviolet (UV) and electrochemical detection (ED). A modified liquid chromatograph was used. Polyacrylate fibers (85 microns) were used to extract the analytes from the aqueous samples. Dynamic and static modes of desorption were compared and the variables affecting both absorption and desorption processes in SPME-HPLC were optimized. Static desorption gave the best recoveries and peak shapes. The performance of the SPME-HPLC-UV-ED method was checked with river water and wastewater. The method enabled estrogenic compounds to be determined at low-microgram l-1 levels in real water samples. Limits of detection were between 0.3 and 1.1 micrograms l-1 using UV detection and between 0.06 and 0.08 microgram l-1 using ED. beta-Estradiol was found in samples from a wastewater treatment plant at concentrations between 1.9 and 2.2 micrograms l-1.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Peñalver, E Pocurull, F Borrull, R M Marcé. 2002-07-26. Method based on solid-phase microextraction--high-performance liquid chromatography with UV and electrochemical detection to determine estrogenic compounds in water samples.. https://doi.org/10.1016/s0021-9673(02)00694-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of ultra-performance liquid chromatography and high-performance liquid chromatography for the determination of priority pesticides in baby foods by tandem quadrupole mass spectrometry.

Determination of 16 priority pesticides and transformation products specified in the EU Baby Food Directive 2003/13/EC has been compared using high-performance liquid chromatography (HPLC) and ultra-performance liquid chromatography (UPLC) coupled to tandem quadrupole mass spectrometry (MS/MS). Prior to analysis, co-extractives were removed from acetonitrile extracts using dispersive solid-phase extraction (SPE) with primary secondary amine (50 mg). Extracts spiked with pesticides at 1 microg kg(-1) yielded average recoveries in the range 85-119%, with relative standard deviations less than 17%. The HPLC-MS/MS and UPLC-MS/MS multi-residue methods developed are simple, rapid and suitable for the quantification and confirmation of the 16 priority pesticides in fruit-, potato- and cereal-based baby food at 1 microg kg(-1). The major advantages of UPLC, using 1.7 microm particles, over HPLC are the speed of analysis, the narrower peaks (giving increased signal-to-noise ratio) and improved confirmation for the targeted pesticides in the analyses of baby foods.

Chromatography, High Pressure Liquid↗

A validated new method for nevirapine quantitation in human plasma via high-performance liquid chromatography.

A fully validated and clinically relevant assay was developed for the assessment of nevirapine concentrations in neonate blood plasma samples. Solid-phase extraction with an acid-base wash series was used to prepare subject samples for analysis. Samples were separated by high performance liquid chromatography and detected at 280 nm on a C8 reverse-phase column in an isocratic mobile phase. The retention times of nevirapine and its internal standard were 5.0 and 6.9 min, respectively. The method was validated by assessment of accuracy and precision (statistical values <15%), specificity, and stability. The assay was linear in the range 25-10,000 ng/mL (r2 > 0.996) and the average recovery was 93% (n = 18). The lower limit of quantification (relative standard deviation <20%) was determined to be 25 ng/mL for 50 microL of plasma, allowing detection of as little as 1.25 ng of nevirapine in a sample. This value represents an increase in sensitivity of up to 30-fold over previously published methods.

Chromatography, High Pressure Liquid↗