Search PubMed⌕ Search

PubMed · 12164701

Improved chip design for integrated solid-phase microextraction in on-line proteomic sample preparation.

Abstract

A recently introduced silicon microextraction chip (SMEC), used for on-line proteomic sample preparation, has proved to facilitate the process of protein identification by sample clean up and enrichment of peptides. It is demonstrated that a novel grid-SMEC design improves the operating characteristics for solid-phase microextraction, by reducing dispersion effects and thereby improving the sample preparation conditions. The structures investigated in this paper are treated both numerically and experimentally. The numerical approach is based on finite element analysis of the microfluidic flow in the microchip. The analysis is accomplished by use of the computational fluid dynamics-module FLOTRAN in the ANSYS software package. The modeling and analysis of the previously reported weir-SMEC design indicates some severe drawbacks, that can be reduced by changing the microextraction chip geometry to the grid-SMEC design. The overall analytical performance was thereby improved and also verified by experimental work. Matrix-assisted laser desorption/ionization mass spectra of model peptides extracted from both the weir-SMEC and the new grid-SMEC support the numerical analysis results. Further use of numerical modeling and analysis of the SMEC structures is also discussed and suggested in this work.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jonas Bergkvist, Simon Ekström, Lars Wallman, Mikael Löfgren, György Marko-Varga, Johan Nilsson, Thomas Laurell. 2002. Improved chip design for integrated solid-phase microextraction in on-line proteomic sample preparation.. https://doi.org/10.1002/1615-9861(200204)2%3A4%3C422%3A%3Aaid-prot422%3E3.0.co%3B2-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Miniaturized thermal lens and fluorescence detection system for microchemical chips.

We have developed a miniaturized two-way detection system using thermal lens and fluorescence spectroscopies for microchip chemistry. The system was composed of laser diode (LD) modules, fiber-based optics combined with a gradient index lens, and miniaturized detection units for thermal lens and fluorescence signals. The detection limits in the thermal lens and fluorescence spectroscopies were 6.3 x 10(-9)M for Ni(II) phthalocyanine tetrasulfonic acid and 3.0 x 10(-9)M for cy5, respectively. The performance of the system with the miniaturized thermal lens was equivalent to that of a conventional thermal lens microscope. The fluorescence sensitivity was comparable to sensitivities offered by conventional miniaturized systems.

Miniaturization↗

Microcoil nuclear magnetic resonance spectroscopy.

In comparison with most analytical chemistry techniques, nuclear magnetic resonance has an intrinsically low sensitivity, and many potential applications are therefore precluded by the limited available quantity of certain types of sample. In recent years, there has been a trend, both commercial and academic, towards miniaturization of the receiver coil in order to increase the mass sensitivity of NMR measurements. These small coils have also proved very useful in coupling NMR detection with commonly used microseparation techniques. A further development enabled by small detectors is parallel data acquisition from many samples simultaneously, made possible by incorporating multiple receiver coils into a single NMR probehead. This review article summarizes recent developments and applications of "microcoil" NMR spectroscopy.

Miniaturization↗

Towards a miniaturised system for dynamic field gradient focused separation of proteins.

Separation and focusing of proteins is described in a miniaturised dynamic field gradient focusing device with a 2.5 cm x 0.1 cm channel filled with a porous polymer monolith. The separation channel is in contact with a parallel electric field channel with five individually addressable electrodes through a porous glass membrane so that a variable field can be generated that drives charged proteins electroosmotically against a constant hydrodynamic flow. Separated pre-stained proteins were detected by means of a digital camera and background subtraction.

Miniaturization↗