Search PubMed⌕ Search

Biomedical subjects

Simon Ekström

Publications and source records attributed to Simon Ekström.

5 recordsLinked to original sources

Integrated selective enrichment target--a microtechnology platform for matrix-assisted laser desorption/ionization-mass spectrometry applied on protein biomarkers in prostate diseases.

The performance of a miniaturized sample processing platform for matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS), manufactured by silicon microfabrication, called integrated selective enrichment target (ISET) technology was evaluated in a biological context. The ISET serves as both sample treatment device and MALDI-MS target, and contains an array of 96 perforated nanovials, which each can be filled with 40 nL of reversed-phase beads. This methodology minimizes the number of sample transfers and the total surface area available for undesired adsorption of the analytes in order to provide high-sensitivity analysis. ISET technology was successfully applied for characterization of proteins coisolated by affinity chromatography of prostate-specific antigen (PSA) from human seminal fluid. The application of ISET sample preparation enabled multiple analyses to be performed on a limited sample volume, which resulted in the discovery that prolactin inducible protein (PIP) was coisolated from the samples.

Biomarkers↗

Autonomous protein sample processing on-chip using solid-phase microextraction, capillary force pumping, and microdispensing.

A capillary force filling microsystem consisting of a chip-integrated solid-phase microextraction (SMEC) array and a microdispenser for sample purification and trace enrichment of peptides is described. The microextraction array was loaded with solid-phase media (50 microm Poros R2 beads) for purification and enrichment of proteomic samples. Samples bound to the SMEC were eluted in a volume of 200 nL. A piezo-electric microdispenser was docked to the array and the samples bound to the SMEC were eluted in a volume of 200 nL using capillary forces. The purified and enriched samples were dispensed onto the matrix-assisted laser desorption/ionization (MALDI) target, providing quality data from samples in the picomolar range. The nanoproteomic platform was compared to corresponding commercial preparation protocols, showing higher mass spectrometry (MS) signal intensities for peptides generated from an alpha-casein digest. The platform was also evaluated with regards to two-dimensional (2-D) gel-derived protein digests from both fibroblast and epithelial target cells.

Electrophoresis, Gel, Two-Dimensional↗

Macro-/nanoporous silicon as a support for high-performance protein microarrays.

The present work demonstrates the possibilities of using macroporous silicon as a substrate for highly sensitive protein chip applications. The formation of 3D porous silicon structures was performed by electrochemical dissolution of monocrystalline silicon. The fabricated macroporous silicon network has a rigid spongelike structure showing high uniformity and mechanical stability. The microfluidic properties of the substrates were found to be essential for a good bioassay performance. Small spot area, good spot reproducibility, and homogeneous spot profiles were demonstrated on the substrates for immobilized aRIgG. Water contact angles were measured on the porous surface and compared to that of planar silicon, silanized glass, and ordinary microscope glass slides. The effect of the porous surface on the performance of a model IgG-binding immunoassay is presented. aRIgG was microdispensed onto the chip surface forming a microarray of spots with high affinity for the target analyte. The dispensing was performed using an in-house-developed piezoelectric flow-through dispenser. Each spot was formed by a single droplet (100 pL) at each position. The macroporous silicon allowed a high-density microarraying with spot densities up to 4400 spots/cm2 in human plasma samples without cross-talk and consumption of only 0.6 pmol of antibodies/1-cm2 array. Antigen levels down to 70 pM were detected.

Antibodies↗

On-chip microextraction for proteomic sample preparation of in-gel digests.

Despite the high sensitivity and relatively high tolerance for contaminants of matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) there is often a need to purify and concentrate the sample solution, especially after in-gel digestion of proteins separated by two-dimensional gel electrophoresis (2-DE). A silicon microextraction chip (SMEC) for sample clean-up and trace enrichment of peptides was manufactured and investigated. The microchip structure was used to trap reversed-phase chromatography media (POROS R2 beads) that facilitates sample purification/enrichment of contaminated and dilute samples prior to the MALDI-TOF MS analysis. The validity of the SMEC sample preparation technique was successfully investigated by performing analysis on a 10 nM peptide mixture containing 2 m urea in 0.1 m phosphate-buffered saline with MALDI-TOF MS. It is demonstrated that the microchip sample clean-up and enrichment of peptides can facilitate identification of proteins from 2-DE separations. The microchip structure was also used to trap beads immobilized with trypsin, thereby effectively becoming a microreactor for enzymatic digestion of proteins. This microreactor was used to generate a peptide map from a 100 nM bovine serum albumin sample.

Electrophoresis, Gel, Two-Dimensional↗

Improved chip design for integrated solid-phase microextraction in on-line proteomic sample preparation.

A recently introduced silicon microextraction chip (SMEC), used for on-line proteomic sample preparation, has proved to facilitate the process of protein identification by sample clean up and enrichment of peptides. It is demonstrated that a novel grid-SMEC design improves the operating characteristics for solid-phase microextraction, by reducing dispersion effects and thereby improving the sample preparation conditions. The structures investigated in this paper are treated both numerically and experimentally. The numerical approach is based on finite element analysis of the microfluidic flow in the microchip. The analysis is accomplished by use of the computational fluid dynamics-module FLOTRAN in the ANSYS software package. The modeling and analysis of the previously reported weir-SMEC design indicates some severe drawbacks, that can be reduced by changing the microextraction chip geometry to the grid-SMEC design. The overall analytical performance was thereby improved and also verified by experimental work. Matrix-assisted laser desorption/ionization mass spectra of model peptides extracted from both the weir-SMEC and the new grid-SMEC support the numerical analysis results. Further use of numerical modeling and analysis of the SMEC structures is also discussed and suggested in this work.

Miniaturization↗