Search PubMed⌕ Search

Biomedical subjects

Lars Wallman

Publications and source records attributed to Lars Wallman.

6 recordsLinked to original sources

Miniaturized solid-phase extraction and sample preparation for MALDI MS using a microfabricated integrated selective enrichment target.

A microfabricated proteomic sample preparation and sample presentation device, Integrated Selective Enrichment Target, (ISET), comprising an array of 96 perforated nanovials is described. Each perforated nanovial can be filled with solid-phase extraction media for purification and concentration of peptides prior to matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). The validity of the ISET sample preparation is shown by analysis of low nM-pM standard samples, as well as biological samples. The ISET solid-phase extraction sample preparation was compared to ZipTip and MassPREP PROtarget sample preparation, demonstrating a superior performance with respect to number of detected peptides and signal intensity of detected peptides.

Caseins↗

Integrated selective enrichment target--a microtechnology platform for matrix-assisted laser desorption/ionization-mass spectrometry applied on protein biomarkers in prostate diseases.

The performance of a miniaturized sample processing platform for matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS), manufactured by silicon microfabrication, called integrated selective enrichment target (ISET) technology was evaluated in a biological context. The ISET serves as both sample treatment device and MALDI-MS target, and contains an array of 96 perforated nanovials, which each can be filled with 40 nL of reversed-phase beads. This methodology minimizes the number of sample transfers and the total surface area available for undesired adsorption of the analytes in order to provide high-sensitivity analysis. ISET technology was successfully applied for characterization of proteins coisolated by affinity chromatography of prostate-specific antigen (PSA) from human seminal fluid. The application of ISET sample preparation enabled multiple analyses to be performed on a limited sample volume, which resulted in the discovery that prolactin inducible protein (PIP) was coisolated from the samples.

Biomarkers↗

Autonomous protein sample processing on-chip using solid-phase microextraction, capillary force pumping, and microdispensing.

A capillary force filling microsystem consisting of a chip-integrated solid-phase microextraction (SMEC) array and a microdispenser for sample purification and trace enrichment of peptides is described. The microextraction array was loaded with solid-phase media (50 microm Poros R2 beads) for purification and enrichment of proteomic samples. Samples bound to the SMEC were eluted in a volume of 200 nL. A piezo-electric microdispenser was docked to the array and the samples bound to the SMEC were eluted in a volume of 200 nL using capillary forces. The purified and enriched samples were dispensed onto the matrix-assisted laser desorption/ionization (MALDI) target, providing quality data from samples in the picomolar range. The nanoproteomic platform was compared to corresponding commercial preparation protocols, showing higher mass spectrometry (MS) signal intensities for peptides generated from an alpha-casein digest. The platform was also evaluated with regards to two-dimensional (2-D) gel-derived protein digests from both fibroblast and epithelial target cells.

Electrophoresis, Gel, Two-Dimensional↗

On-chip microextraction for proteomic sample preparation of in-gel digests.

Despite the high sensitivity and relatively high tolerance for contaminants of matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) there is often a need to purify and concentrate the sample solution, especially after in-gel digestion of proteins separated by two-dimensional gel electrophoresis (2-DE). A silicon microextraction chip (SMEC) for sample clean-up and trace enrichment of peptides was manufactured and investigated. The microchip structure was used to trap reversed-phase chromatography media (POROS R2 beads) that facilitates sample purification/enrichment of contaminated and dilute samples prior to the MALDI-TOF MS analysis. The validity of the SMEC sample preparation technique was successfully investigated by performing analysis on a 10 nM peptide mixture containing 2 m urea in 0.1 m phosphate-buffered saline with MALDI-TOF MS. It is demonstrated that the microchip sample clean-up and enrichment of peptides can facilitate identification of proteins from 2-DE separations. The microchip structure was also used to trap beads immobilized with trypsin, thereby effectively becoming a microreactor for enzymatic digestion of proteins. This microreactor was used to generate a peptide map from a 100 nM bovine serum albumin sample.

Electrophoresis, Gel, Two-Dimensional↗

Improved chip design for integrated solid-phase microextraction in on-line proteomic sample preparation.

A recently introduced silicon microextraction chip (SMEC), used for on-line proteomic sample preparation, has proved to facilitate the process of protein identification by sample clean up and enrichment of peptides. It is demonstrated that a novel grid-SMEC design improves the operating characteristics for solid-phase microextraction, by reducing dispersion effects and thereby improving the sample preparation conditions. The structures investigated in this paper are treated both numerically and experimentally. The numerical approach is based on finite element analysis of the microfluidic flow in the microchip. The analysis is accomplished by use of the computational fluid dynamics-module FLOTRAN in the ANSYS software package. The modeling and analysis of the previously reported weir-SMEC design indicates some severe drawbacks, that can be reduced by changing the microextraction chip geometry to the grid-SMEC design. The overall analytical performance was thereby improved and also verified by experimental work. Matrix-assisted laser desorption/ionization mass spectra of model peptides extracted from both the weir-SMEC and the new grid-SMEC support the numerical analysis results. Further use of numerical modeling and analysis of the SMEC structures is also discussed and suggested in this work.

Miniaturization↗

Tissue reactions evoked by porous and plane surfaces made out of silicon and titanium.

Square-shaped silicon or titanium implants with plane or porous surfaces surrounded by a rim of silicone were implanted in the rat abdominal wall for evaluation of the tissue response after one, six, or 12 weeks. Cell damage was identified as increased membrane permeability using fluorescence microscopy by injection of propidium iodide prior to the killing of the rats. Capsule thickness and immunohistochemical quantification of macrophages were used as a further measure of the foreign-body reaction. There were no significant differences in capsular cell densities for macrophages, total cells (macrophages, fibroblasts, and other cells), or necrotic cells at the different time points for the four surfaces studied. However, significant differences in the kinetics of the response were found between plane surfaces compared with porous ones. Both types of plane surfaces developed a significant increase in capsule thickness over time in contrast to the porous implants. Porous silicon displayed a significant decrease in total cells in the reactive capsule over time. Furthermore, porous silicon and titanium surfaces displayed a significant decrease in total cell numbers at the implant interface between six and 12 weeks. The present study demonstrated that implanted silicon elicited soft-tissue reactions comparable to that of titanium.

Abdominal Muscles↗