Search PubMed⌕ Search

PubMed · 11394592

Tsunami.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R E Leach. Tsunami.. https://doi.org/10.1177/03635465010290030101

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Three-dimensional optical high-resolution profiler with a large observation field: foot arch behavior under low static charge studies.

Our aim is to describe a method for detecting small deformations from a three-dimensional (3D) shape of large lateral dimensions. For this purpose the measurement method is based on the simultaneous utilization of several 3D optical systems and the phase-shifting technique. In this way, the following problems appear: optical distortion due to the large field observed, nonlinear phase-to-height conversion, conversion of image coordinates into object coordinates for each 3D optical system, and coordinate unification of all optical systems. The resolution is 50 microm with a field of view of 320 mm x 150 mm. We used this system to study the 3D human foot arch deformation under low loads in vivo. First results indicate the hysteresis behavior of the human foot under a low load (50 to 450 N).

Biomechanical Phenomena↗

Design parameters for rotating cylindrical filtration.

Rotating cylindrical filtration displays significantly reduced plugging of filter pores and build-up of a cake layer, but the number and range of parameters that can be adjusted complicates the design of these devices. Twelve individual parameters were investigated experimentally by measuring the build-up of particles on the rotating cylindrical filter after a fixed time of operation. The build-up of particles on the filter depends on the rotational speed, the radial filtrate flow, the particle size and the gap width. Other parameters, such as suspension concentration and total flow rate are less important. Of the four mechanisms present in rotating filters to reduce pore plugging and cake build-up, axial shear, rotational shear, centrifugal sedimentation and vortical motion, the evidence suggests rotational shear is the dominant mechanism, although the other mechanisms still play minor roles. The ratio of the shear force acting parallel to the filter surface on a particle to the Stokes drag acting normal to the filter surface on the particle due to the difference between particle motion and filtrate flow can be used as a non-dimensional parameter that predicts the degree of particle build-up on the filter surface for a wide variety of filtration conditions.

Biomechanical Phenomena↗

A study of the mechanical stability of scoliosis constructs using variable numbers of sublaminar wires.

Sublaminar wiring with posterior instrumentation is one of the methods used when long fusions involving 10-12 thoracolumbar levels are required. Classically, wires are used at every consecutive level to make the construct as rigid as possible, although complications like dural tears, cerebrospinal fluid leak, and neurological deficit have been reported during their passage. We compared the mechanical stability under torsional strain of five specimens of each of three construct designs, by static and fatigue testing, using an electro-servo-hydraulic testing machine. In construct A, a contoured Hartshill rectangle was used from T2 to L2, with sublaminar wires passed at every level. In construct B, the Hartshill rectangle was wired to the spine at every alternate level. In construct C, every alternate level was wired except at the proximal end, where two consecutive levels were wired. Industrially fabricated spine models were used to prepare these constructs. The intervertebral motion within the construct was measured using the Fastrak magnetic field sensor device. On static testing, no statistically significant difference was found in the rotational displacement of the three construct designs. On fatigue testing, all samples of construct B consistently failed, with breakage of the wire at the most proximal level on the left side. But on adding additional wires to the next level (construct C), all five samples withstood fatigue testing at 300 N load to three million cycles. We conclude that wiring alternate levels instead of every level does not compromise the stability of the construct, provided that the most proximal two levels are consecutively wired. This practice would minimise the risk of dural tears and cord damage during wire passage and reduce surgical time, not to mention the economic benefits.

Biomechanical Phenomena↗