Non-invasive radiation-free monitoring of regional lung ventilation in critically ill infants.

OBJECTIVE: Established techniques used to examine lung function in critically ill infants cannot continuously follow regional aspects of lung ventilation although this information would be beneficial for proper therapy planning. We have studied the applicability and clinical relevance of a relatively new non-invasive radiation-free imaging method, electrical impedance tomography (EIT), in monitoring regional lung function in paediatric intensive care patients. DESIGN: Prospective study. SETTING: Neonatal and paediatric intensive care unit (ICU) at a university hospital. PATIENTS: Eight infants (1 day-7 years old) suffering from miscellaneous diseases requiring intensive care therapy. INTERVENTIONS: Adjustment of ventilator settings, surfactant administration, and postural changes. MEASUREMENTS AND RESULTS: Repeated EIT measurements were performed with the intention to monitor regional lung ventilation in mechanically ventilated and spontaneously breathing infants. The follow-up time ranged between 1 and 11 days. During individual EIT measurements of 100-s duration electrical voltages resulting from repetitive injection of small electrical currents were continuously measured on the thoracic circumference using conventional surface electrodes. Acquired data were used to generate functional cross-sectional thoracic images of regional lung ventilation. A total of 638 EIT measurements were performed. The redistribution of lung ventilation and changes in regional ventilation magnitude resulting from adjusted positive end-expiratory pressure, peak inspiratory pressure, inspiration-expiration ratio, surfactant instillation, and prone or supine positioning were identified. CONCLUSIONS: Provided that EIT hardware and software are further developed to guarantee stable and undisturbed measurements in the ICU and that practical handling is improved, this non-invasive method may become a useful bedside monitoring tool of regional lung ventilation in critically ill infants.

Child↗

Impedance analyser module for EIT and spectroscopy using undersampling.

In this paper we present the concept, the design and the test procedure for a DSP-based high-precision and high-performance wide-band (up to 10 MHz) bioimpedance analyser module for application in EIT or bioimpedance spectroscopy. The module implements a digital concept with appropriate signal conditioning hardware for voltage and current measurement, early signal digitization and subsequent digital signal processing in order to calculate the components of impedance (or admittance). At low frequencies, the module utilizes the conventional direct conversion method, whereas at high frequencies the undersampling technique is used. The advantages of the described system are the following: (a) the frequency range is extended to higher frequencies, (b) the number of data sampled per time interval is significantly reduced, and (c) the current consumption and the costs of the ADCs can be significantly reduced. The validation procedure is performed by comparing the measured and theoretical values of the magnitude and the phase of the impedance for a commonly used tissue model. The module offers an accuracy of better than 0.012% for the magnitude of impedance and better than 0.02 degrees for the phase.

Electric Impedance↗

Gravity effects on regional lung ventilation determined by functional EIT during parabolic flights.

Gravity-dependent changes of regional lung function were studied during normogravity, hypergravity, and microgravity induced by parabolic flights. Seven healthy subjects were followed in the right lateral and supine postures during tidal breathing, forced vital capacity, and slow expiratory vital capacity maneuvers. Regional 1) lung ventilation, 2) lung volumes, and 3) lung emptying behavior were studied in a transverse thoracic plane by functional electrical impedance tomography (EIT). The results showed gravity-dependent changes of regional lung ventilation parameters. A significant effect of gravity on regional functional residual capacity with a rapid lung volume redistribution during the gravity transition phases was established. The most homogeneous functional residual capacity distribution was found at microgravity. During vital capacity and forced vital capacity in the right lateral posture, the decrease in lung volume on expiration was larger in the right lung region at all gravity phases. During tidal breathing, the differences in ventilation magnitudes between the right and left lung regions were not significant in either posture or gravity phase. A significant nonlinearity of lung emptying was determined at normogravity and hypergravity. The pattern of lung emptying was homogeneous during microgravity.

Adult↗

Quantitative evaluation of the performance of different electrical tomography devices.

Two widely used electrical tomography systems, the Sheffield Mark I and the DAS-01P, were quantitatively evaluated and compared to the newly developed Goe-MF system. The performance was quantified using a hardware phantom which closely matches the real input and transfer impedances of the human thorax and allows measurements equivalent to different states of lung inflation. Our results demonstrate that adequate averaging is necessary for noise reduction for the Mark I and especially for the DAS-01P system to get meaningful results even in visualizing maximal respiratory manoeuvres. The Goe-MF system showed a notably improved signal-to-noise ratio which allows also dynamic measurements at low levels of lung volume changes, e.g., in intensive care lung injury patients.

Calibration↗

Influence of opioids on the vascular tone of isolated porcine coronary artery segments.

BACKGROUND: It was the aim of this study to elucidate the influence of opioids on coronary vascular tone using the model of isolated porcine coronary artery segments. METHODS: We studied the effects of fentanyl (0.01, 0.1, 1.0 microg ml(-1)), alfentanil (0.1, 1.0, 10 microg ml(-1)), and sufentanil (0.01, 0.1, 1.0 microg ml(-1)) on the contractile response to three vasoconstrictors, acetylcholine, histamine and serotonin. RESULTS: Fentanyl (0.1, 1.0 microg x ml(-1)) dose-dependently attenuated the contractile response to acetylcholine, but not to histamine and serotonin. There were no differences in fentanyl's vasorelaxing potency between rings with intact and denuded endothelium. Alfentanil and sufentanil did not exert any significant influence on any of the vasoconstrictors tested. CONCLUSION: It is concluded that, in isolated porcine coronary artery rings, fentanyl at high concentrations has an attenuating effect on acetylcholine-induced contractions, which is independent of endothelial function, whereas alfentanil and sufentanil do not influence coronary vascular tone.

Analgesics, Opioid↗

Do muscle relaxants influence vascular tone in isolated coronary artery segments?

The aim of this study was to elucidate the influence of four neuromuscular blocking substances on coronary vascular tone using the model of isolated porcine coronary artery segments. We studied the effects of four muscle relaxants, atracurium, pancuronium, rocuronium, and vecuronium (0.1, 1, and 10 microg mL-1 each), on the contractile response to three vasoconstrictors: acetylcholine, histamine, and serotonin. None of the neuromuscular blocking agents under investigation exerted a significant influence on the vasoconstricting effects of these mediators except for pancuronium, which dose-dependently attenuated acetylcholine-mediated contractions (-10.8% attenuation for 10 microg mL-1 pancuronium, P < 0.05). There was no difference between vessels with intact endothelium and denuded preparations. It is concluded that high-dose pancuronium exerts an antimuscarinic effect in vascular smooth muscle. The other neuromuscular agents studied do not alter vascular reactivity of isolated porcine coronary arteries.

Acetylcholine↗

Propofol and thiopental attenuate the contractile response to vasoconstrictors in human and porcine coronary artery segments.

The effects of propofol and thiopental on three vasoconstrictors, acetylcholine, histamine, and serotonin were studied in isolated porcine and human coronary artery rings. Propofol and thiopental attenuated the contractile response to all mediators in a dose-dependent manner. This dilating effect was fairly weak using low concentrations (propofol 1 microg mL-1 and 10 microg mL-1, thiopental 5 microg mL-1 and 10 microg mL-1). In the presence of high concentrations (propofol 100 microg mL-1, thiopental 50 microg mL-1) marked relaxation was observed (propofol -32% up to -49%, P < 0,05; thiopental -23% up to -67%, P < 0.05). These dilating effects were seen both in intact and denuded rings, the differences were not significant. Human coronary artery segments were relaxed by thiopental (-22% to -76%) and propofol (-11% to -67%) to a similar extent. Our data indicate that propofol and thiopental relax isolated coronary segments in a dose-dependent manner, and that there is no evidence that these effects are dependent of endothelial factors.

Acetylcholine↗

A simple method to check the dynamic performance of electrical impedance tomography systems.

The test concept as well as the design of a simple resistor phantom suitable for the evaluation of the properties of electrical impedance tomographic (EIT) systems is presented. Input and transfer impedance of the phantom are matched with those of the human thorax. Amplitude of the local impedance variations similar to in vivo conditions (ventilation) can be intentionally set to perform measurements on different states. The theoretical potential differences between the electrodes are calculated. The evaluation procedure is performed in terms of the local amplitude of the relative impedance change as well as the local distribution of noise. The whole procedure can be applied either to compare quantitatively the performance of different EIT data acquisition systems or to determine the amount of measurement disturbance caused by the external electrical environment in clinical settings.

Cardiography, Impedance↗

Monitoring regional lung ventilation by functional electrical impedance tomography during assisted ventilation.

A new approach in discriminating the regional air volume changes in the lungs associated with either spontaneous or mechanical ventilation during assisted ventilation is presented. Impedance data are obtained by conventional electrical impedance tomography (EIT). The data are filtered in the range of either the spontaneous or the ventilator rate and processed by the functional EIT (f-EIT) evaluation technique, whereby the variation of the respective EIT data with time is determined and imaged. EIT measurements performed in an infant during synchronized intermittent mandatory ventilation were evaluated with this method and indicated that the specific local lung volume swings related to spontaneous and mechanical inhalations can be separated and imaged as tomograms. This noninvasive approach may become useful in optimizing the ventilatory pattern during advanced forms of artificial ventilation and may help the clinician in the therapy management of individual patients.

Blood Gas Analysis↗

Errors of the backextrapolation method in determination of the blood volume.

Backextrapolation is an empirical method to calculate the central volume of distribution (for example the blood volume). It is based on the compartment model, which says that after an injection the substance is distributed instantaneously in the central volume with no time delay. The occurrence of recirculation is not taken into account. The change of concentration with time of indocyanine green (ICG) was observed in an in vitro model, in which the volume was recirculating in 60 s and the clearance of the ICG could be varied. It was found that the higher the elimination of ICG, the higher was the error of the backextrapolation method. The theoretical consideration of Schröder et al (Biomed. Tech. 42 (1997) 7-11) was proved. If the injected substance is eliminated somewhere in the body (i.e. not by radioactive decay), the backextrapolation method produces large errors.

Artifacts↗

Thoracic electrical impedance tomographic measurements during volume controlled ventilation-effects of tidal volume and positive end-expiratory pressure.

The aim of the study was to analyze thoracic electrical impedance tomographic (EIT) measurements accomplished under conditions comparable with clinical situations during artificial ventilation. Multiple EIT measurements were performed in pigs in three transverse thoracic planes during the volume controlled mode of mechanical ventilation at various tidal volumes (V(T)) and positive end-expiratory pressures (PEEP). The protocol comprised following ventilatory patterns: 1) V(T)(400, 500, 600, 700 ml) was varied in a random order at various constant PEEP levels and 2) PEEP (2, 5, 8, 11, 14 cm H2O) was randomly modified during ventilation with a constant V(T). The EIT technique was used to generate cross-sectional images of 1) regional lung ventilation and 2) regional shifts in lung volume with PEEP. The quantitative analysis was performed in terms of the tidal amplitude of the impedance change, reflecting the volume of delivered gas at various preset V(T) and the end-expiratory impedance change, revealing the variation of the lung volume at various PEEP levels. The results showed: 1) an increase in the tidal amplitude of the impedance change, proportional to the delivered V(T) at all constant PEEP levels, 2) a rising end-expiratory impedance change, with PEEP reflecting an increase in gas volume, and 3) a PEEP-dependent redistribution of the ventilated gas between the planes. The generated images and the quantitative results indicate the ability of EIT to identify regional changes in V(T) and lung volume during mechanical ventilation.

Animals↗

Mapping of capillary flow, cellular redox state, and resting membrane potential in hypoperfused rat myocardium.

The influence on myocyte viability of ischemia-induced changes in capillary perfusion was studied in the hearts of anesthetized rats subjected to partial occlusion of the left coronary artery for 45 min. Timed plasma labeling was applied to determine perfusion patterns. Changes in the fluorescence of preloaded potential-sensitive dyes [tetramethylrhodamine methyl ester (TMRM) and bis-oxonol], of trypan blue, and of endogeneous NADH were utilized in characterizing myocyte viability in histological sections of the heart. Within the hypoperfused zone, localized areas appeared vascularly nonlabeled for periods of at least 10 min. Within these areas a reduction in TMRM fluorescence occurred in 82. 5% of the tissue, signaling a reduced resting membrane potential. In the same areas 37.7% of the myocytes revealed an NADH fluorescence lower than that regularly found in anoxic tissues. This correlated with an especially low level of TMRM, with increased fluorescence bis-oxonol and with an accumulation of trypan blue. In conclusion, in localized hypoperfusion-induced zones lacking capillary flow, an inhomogeneous pattern of reductions in myocyte viability develops, which appears to be relevant in ischemia-induced arrhythmias.

Animals↗

Optimizing deconvolution techniques by the application of the Münchhausen meta algorithm.

A deconvolution applied to disturbed data often gives poor results, due to fundamental difficulties associated with ill-posed problems. Many numerical and theoretical methods have been invented to circumvent this phenomenon. Their performance varies, depending on the given problem and data. The main aim of this paper is to provide a decision rule for choosing a method for deconvolution and application of this method to the same data. We have called this meta-algorithm Münchhausen. In this paper we introduce and describe for the first time the basic principle of artificial disturbance of the data in the set-up of deconvolution. We demonstrate some interesting features of the random procedure Münchhausen, such as the non parametric set-up, robustness to disturbance of the data and last but not least good performance.

Algorithms↗

Electrical impedance tomography in monitoring experimental lung injury.

OBJECTIVE: To apply electrical impedance tomography (EIT) and the new evaluation approach (the functional EIT) in monitoring the development of artificial lung injury. DESIGN: Acute experimental trial. SETTING: Operating room for animal experimental studies at a university hospital. SUBJECTS: Five pigs (41.3 +/- 4.1 kg, mean body weight +/- SD). INTERVENTIONS: The animals were anaesthetised and mechanically ventilated. Sixteen electrodes were attached on the thoracic circumference and used for electrical current injection and surface voltage measurement. Oleic acid was applied sequentially (total dose 0.05 ml/kg body weight) into the left pulmonary artery to produce selective unilateral lung injury. MEASUREMENTS AND RESULTS: The presence of lung injury was documented by significant changes of PaCO2 (40.1 mmHg vs control 37.1 mmHg), PaO2 (112.3 mmHg vs 187.5 mmHg), pH (7.35 vs 7.42), mean pulmonary arterial pressure (29.2 mmHg vs 20.8 mmHg) and chest radiography. EIT detected 1) a regional decrease in mean impedance variation over the affected left lung (-41.4% vs control) and an increase over the intact right lung (+ 20.4% vs control) indicating reduced ventilation of the affected, and a compensatory augmented ventilation of the unaffected lung and 2) a pronounced fall in local baseline electrical impedance over the injured lung (-20.6% vs control) with a moderate fall over the intact lung (-10.0% vs control) indicating the development of lung oedema in the injured lung with a probable atelectasis formation in the contralateral one. CONCLUSION: The development of the local impairment of pulmonary ventilation and the formation of lung oedema could be followed by EIT in an experimental model of lung injury. This technique may become a useful tool for monitoring local pulmonary ventilation in intensive care patients suffering from pulmonary disorders associated with regionally reduced ventilation, fluid accumulation and/or cell membrane changes.

Acute Disease↗

Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography.

BACKGROUND: Electrical impedance tomography (EIT) is a noninvasive technique providing cross-sectional images of the thorax. We have tested an extended evaluation procedure, the functional EIT (f-EIT), to identify the local shifts of ventilation known to occur during the transition between spontaneous, controlled and assisted ventilation modes. METHODS: Ten patients scheduled for elective laparotomy were studied in the surgical ward, operating theatre and ICU during spontaneous and different modes of mechanical ventilation. Sixteen ECG electrodes were placed on the circumference of the thorax and connected with an EIT device (APT System Mark I, IBEES, Sheffield, UK). Measurements lasting 180 s were performed and f-EIT images of regional ventilation computed. The geometrical centre of ventilation was determined to quantify the regional distribution of lung ventilation during individual modes of ventilation. RESULTS: F-EIT confirmed the differences in the distribution of ventilation associated with various modes of artificial ventilation. Accentuated ventilation of the dependent lung regions was observed during spontaneous breathing, whereas a shift of the centre of ventilation to the nondependent regions was found during controlled ventilation. In the course of assisted ventilation a continuous displacement of the centre of ventilation back towards the dependent lung regions, consistent with an increased proportion of spontaneous breathing, was detected. Unassisted spontaneous breathing after weaning from mechanical ventilation resulted in a similar ventilation distribution as during tidal breathing prior to surgery. CONCLUSION: F-EIT determined the redistribution of lung ventilation during different modes of mechanical ventilation. We expect that f-EIT will become a useful noninvasive bedside monitoring technique for imaging regional ventilation in pulmonary diseased patients during mechanical ventilation.

Abdomen↗

Simulation of the initial concentration-time course after intravenous application of the drug.

In this paper we present a widely applicable computational method for the description of the initial concentration-time-course after intravenous injection of a substance. The intravascular concentration-time course, r, is described as r = c0 + g x r, where the asterisk denotes the convolution operation, c0 is the concentration-time course during the first passage of the substance and g is the transport function of the body. If the body transport function is known, then the concentration-time course of a substance can be predicted. The site of interest can be chosen arbitrarily, i.e. the concentration-time course in the arterial circulation supplying any organ can be described. This might be of special interest for the optimal design of intravenous injections of contrast media, where initial concentrations at the region of interest determine the success of the diagnostic procedure.

Animals↗

Development and initial in vivo testing of a new hydraulic drive system (Paedipump) for circulatory support in infants.

The main limitation in the use of circulatory support in children is the lack of an adequate system with regard to size and pumping capacity. Recently, two pneumatically driven ventricular support systems with low volume chambers for use in a pediatric population became available. We have developed a hydraulic drive system with an advantageous exact control of the stroke volume. The system enables two different modes of operation: the full-empty and the filled-empty modes. In both cases the ventricle is empty at the end of systole. This new system was tested in experimental animals (6 pigs, body weight 9.5-14.0 kg) with normal and reduced left ventricular function (MAP<45 mmHg). A 25 ml ventricle (HIA-Medos) was implanted. The full-empty and the filled-empty mode used led to a significant load reduction, both in animals with normal and impaired cardiac function. Plasma lactate levels, pH-values and total body O2-consumption were in the normal range during circulatory support indicating adequate organ perfusion. Results showed that sufficient ventricular support was achieved during all pumping modes due to the possibility of controlling and modifying the stroke volume of the hydraulically driven support system employed according to necessity. This is a promising feature for its future application in infants with congenital or acquired heart diseases.

Animals↗