Impedance analyser module for EIT and spectroscopy using undersampling.

In this paper we present the concept, the design and the test procedure for a DSP-based high-precision and high-performance wide-band (up to 10 MHz) bioimpedance analyser module for application in EIT or bioimpedance spectroscopy. The module implements a digital concept with appropriate signal conditioning hardware for voltage and current measurement, early signal digitization and subsequent digital signal processing in order to calculate the components of impedance (or admittance). At low frequencies, the module utilizes the conventional direct conversion method, whereas at high frequencies the undersampling technique is used. The advantages of the described system are the following: (a) the frequency range is extended to higher frequencies, (b) the number of data sampled per time interval is significantly reduced, and (c) the current consumption and the costs of the ADCs can be significantly reduced. The validation procedure is performed by comparing the measured and theoretical values of the magnitude and the phase of the impedance for a commonly used tissue model. The module offers an accuracy of better than 0.012% for the magnitude of impedance and better than 0.02 degrees for the phase.

Electric Impedance↗

Gravity effects on regional lung ventilation determined by functional EIT during parabolic flights.

Gravity-dependent changes of regional lung function were studied during normogravity, hypergravity, and microgravity induced by parabolic flights. Seven healthy subjects were followed in the right lateral and supine postures during tidal breathing, forced vital capacity, and slow expiratory vital capacity maneuvers. Regional 1) lung ventilation, 2) lung volumes, and 3) lung emptying behavior were studied in a transverse thoracic plane by functional electrical impedance tomography (EIT). The results showed gravity-dependent changes of regional lung ventilation parameters. A significant effect of gravity on regional functional residual capacity with a rapid lung volume redistribution during the gravity transition phases was established. The most homogeneous functional residual capacity distribution was found at microgravity. During vital capacity and forced vital capacity in the right lateral posture, the decrease in lung volume on expiration was larger in the right lung region at all gravity phases. During tidal breathing, the differences in ventilation magnitudes between the right and left lung regions were not significant in either posture or gravity phase. A significant nonlinearity of lung emptying was determined at normogravity and hypergravity. The pattern of lung emptying was homogeneous during microgravity.

Adult↗

Quantitative evaluation of the performance of different electrical tomography devices.

Two widely used electrical tomography systems, the Sheffield Mark I and the DAS-01P, were quantitatively evaluated and compared to the newly developed Goe-MF system. The performance was quantified using a hardware phantom which closely matches the real input and transfer impedances of the human thorax and allows measurements equivalent to different states of lung inflation. Our results demonstrate that adequate averaging is necessary for noise reduction for the Mark I and especially for the DAS-01P system to get meaningful results even in visualizing maximal respiratory manoeuvres. The Goe-MF system showed a notably improved signal-to-noise ratio which allows also dynamic measurements at low levels of lung volume changes, e.g., in intensive care lung injury patients.

Calibration↗

A simple method to check the dynamic performance of electrical impedance tomography systems.

The test concept as well as the design of a simple resistor phantom suitable for the evaluation of the properties of electrical impedance tomographic (EIT) systems is presented. Input and transfer impedance of the phantom are matched with those of the human thorax. Amplitude of the local impedance variations similar to in vivo conditions (ventilation) can be intentionally set to perform measurements on different states. The theoretical potential differences between the electrodes are calculated. The evaluation procedure is performed in terms of the local amplitude of the relative impedance change as well as the local distribution of noise. The whole procedure can be applied either to compare quantitatively the performance of different EIT data acquisition systems or to determine the amount of measurement disturbance caused by the external electrical environment in clinical settings.

Cardiography, Impedance↗