Search PubMed⌕ Search

PubMed · 11089991

Optimized speech understanding with the continuous interleaved sampling speech coding strategy in patients with cochlear implants: effect of variations in stimulation rate and number of channels.

Abstract

The purpose of this study was to investigate the effect of systematic variations in stimulation rate and number of channels on speech understanding in 13 patients with cochlear implants who used the continuous interleaved sampling speech coding strategy. Reducing the stimulation rate from 1,515 to 1,730 pulses per second per channel to 600 pulses per second per channel resulted in decreased overall performance; the understanding of monosyllables and consonants was more affected than the understanding of vowels. Reducing the number of active channels below 7 or 8 channels decreased speech understanding; the identification of vowels and monosyllables was most affected. We conclude that vowel recognition with the continuous interleaved sampling strategy relies on spectral cues more than on temporal cues, increasing with the number of active channels, whereas consonant recognition is more dependent on temporal cues and stimulation rate.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Kiefer, C von Ilberg, V Rupprecht, J Hubner-Egner, R Knecht. 2000. Optimized speech understanding with the continuous interleaved sampling speech coding strategy in patients with cochlear implants: effect of variations in stimulation rate and number of channels.. https://doi.org/10.1177/000348940010901105

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Cochlear implantation in a patient with bilateral deep brain stimulators.

OBJECTIVE: We report the case of a patient successfully implanted with a Nucleus Contour cochlear implant after placement of a deep brain stimulator for Parkinson disease. METHODS: The authors conducted a case report and literature review. RESULTS: Successful hookup and mapping of the device was performed 1 month after implantation without evidence of aberrant activity of the deep brain stimulators. CONCLUSIONS: To our knowledge, this is the first reported case of successful implantation of both a cochlear implant and a deep brain stimulator in the same patient. We have outlined one approach to avoiding detrimental interactions between cochlear implant and deep brain stimulator devices.

Cochlear Implantation↗

[Measurement of skull thickness by ultrasound].

BACKGROUND: The presurgical diagnostic for measurement of skull thickness for implantations of epithesis or bone anchored hearing aids is limited on computed tomography (CT) of petrosal bone up to now. Testing of ultrasound for measurement of skull thickness is the aim of our study . MATERIAL AND METHODS: 20 patients has been included, which had got a computed tomography of nasal sinus, skull or petrosal bone. The potential localisations of implantations have been measured by 3D-reconstruction of computed tomography. The results have been statistical compared by sonographic investigations (7.5 MHz Soundhead) at the same localisation. RESULTS: The mean skull thickness has been 5,2 mm in computed tomography. Comparison has described a mean skull thickness of 4,2 mm in sonography. Statistical comparison has shown that ultrasound has been measured statistical significant too small. CONCLUSIONS: The skull thickness can be described and measured by sonography. However mean skull thickness has been measured statistical significant too small. In spite of this, conclusions relating to presurgical diagnostic, for instance for the implantation of epithesis and bone anchored hearing aids, can be drawn by sonographic data.

Cochlear Implantation↗

Developmental delay and outcomes in paediatric cochlear implantation: implications for candidacy.

OBJECTIVE: Criteria for paediatric cochlear implant candidacy continue to evolve, as research indicates an increasingly broad range of children for whom the procedure can produce benefit. Children with difficulties in addition to their deafness, or global developmental delay, are not routinely excluded. The aim of this study is to explore the association between developmental delay in young paediatric cochlear implant candidates and progress with the device. MATERIALS AND METHODS: The study is a retrospective case series analysis of 32 children, aged between 1.2 and 2.8 years at pre-implant assessment. Children were assessed using the Schedule of Growing Skills II and IT-MAIS before implantation. Progress in speech perception and Speech Intelligibility was monitored using the E2L toy test and Speech Intelligibility Rating (SIR), respectively, 1 and 2 years after switch-on. RESULTS: Data were subjected to regression analyses, with either the E2L or SIR as the outcome variables, and variables derived from the Schedule of Growing Skills II (general development and cognitive functioning), IT-MAIS, age at switch-on and average aided hearing loss pre-implant as the predictor variables. In each analysis the strongest (and statistically significant) predictors of speech perception and Speech Intelligibility were the measures of general development and cognitive functioning, accounting for around 40% of the variance in outcomes. CONCLUSION: This study indicates the value of routinely assessing the general development of young paediatric cochlear implant candidates, as part of the pre-implant decision-making process. Significant developmental delay is predictive of poor outcomes, but children with a mild delay do make appreciable progress. Developmental assessment of young deaf children is therefore important in terms of candidacy decisions and counselling parents regarding potential benefit from a cochlear implant.

Cochlear Implantation↗