Search PubMed⌕ Search

PubMed · 10980087

A digital 3-dimensional method for computing great artery flows: in vitro validation studies.

Abstract

BACKGROUND: Conventional 2-dimensional Doppler large vessels are prone to inaccuracy. Three-dimensional (3D) volume imaging provides the opportunity to make cross-sectional flow calculations through digital spatiotemporal integration of flow velocity, area, and profile. METHODS: A new digital 3D color Doppler reconstruction method was used to generate radially acquired flow data sets. Raw scanline data with digital velocity assignments, obtained by scanning parallel to flow, were transferred from a specially programmed but otherwise conventional ultrasonographic system, which controlled a multiplane transesophageal probe, to a computer workstation via an Ethernet link for assimilation into color 3D data sets. This configuration was used to study 20 pulsatile laminar flows (stroke volumes 30 to 70 mL and peak flow rates 65 to 205 mL/s) in a curved tube model with an oval cross-sectional geometry. After generation of the color 3D data set, flow velocity values from cross sections perpendicular to the tubes were analyzed to determine flow rate and stroke volume. RESULTS: The flows from 3D digital velocity profiles showed close correlation with peak instantaneous flow rates (r = 0.99, y = 1.01x-0.9, standard error of estimate 4.1 mL/s). When interpreted with pulsed wave Doppler data obtained through the cardiac cycle, they also allowed computation of stroke volume (r = 0.98, y = 1.44x-2.5, standard error of estimate 3.8 mL). CONCLUSION: The ability to compute laminar flows from 3D digital data sets obtained parallel to the direction of flow and without the need for geometric assumptions represents an important opportunity for and advantage of 3D color Doppler echocardiography.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Irvine, X N Li, Y Mori, S Wanitkun, X Li, P R Detmer, R W Martin, A Pope, G A Schwartz, R A Rusk, A Kenny, D J Sahn. 2000. A digital 3-dimensional method for computing great artery flows: in vitro validation studies.. https://doi.org/10.1067/mje.2000.106049

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Stress echocardiography in 11 patients with symptoms of ischemia and a myocardial bridge: no indication of a causal connection in 10 cases].

OBJECTIVE: To determine whether in patients with a myocardial bridge, systolic compression of the affected coronary branch may cause cardiac ischaemia and is of clinical relevance. DESIGN: Pilot inventory. METHOD: In 11 consecutive patients with an established myocardial bridge who presented with possible ischaemic symptoms angiographic dobutamine stress-echocardiography was used to visualize hypokinesia caused by ischaemia in the area ofmyocardium supplied by the bridged artery. RESULTS: Hypokinesia was observed in the area supplied by the bridged artery in one of the patients (9%). The symptoms in the other patients were not associated with the bridge. CONCLUSION: The clinical relevance of myocardial bridging appeared to be smaller than is generally assumed. In patients with known myocardial bridging and symptoms that could be caused by myocardial ischaemia, it should first be established that the bridge is actually causing the ischaemia before any therapeutic intervention aimed at the bridge is undertaken.

Coronary Vessels↗

Double orifice tricuspid valve in an infant with tetralogy of Fallot.

Atrioventricular valve duplication, also known as double orifice valve, is an excitingly rare anomaly that can involve either the mitral or more uncommonly the tricuspid valve. Herein we describe a case of a double orifice tricuspid valve that prejudiced the complete repair in a symptomatic infant with tetralogy of Fallot.

Coronary Vessels↗