Biomedical subjects
D J Sahn
Publications and source records attributed to D J Sahn.
Relation of atrial size and function to Doppler indexes of diastolic function in normal human fetuses.
Fetal atrial function is compared with diastolic ventricular function indexes. The falloff of hyperfunction in fetal atrial contraction patterns matches sequentially the lessening of A wave dominance in the Doppler filling patterns for both ventricles.
New echocardiographic windows for quantitative determination of aortic regurgitation volume using color Doppler flow convergence and vena contracta.
Color Doppler images of aortic regurgitation (AR) flow acceleration, flow convergence (FC), and the vena contracta (VC) have been reported to be useful for evaluating severity of AR. However, clinical application of these methods has been limited because of the difficulty in clearly imaging the FC and VC. This study aimed to explore new windows for imaging the FC and VC to evaluate AR volumes in patients and to validate this in animals with chronic AR. Forty patients with AR and 17 hemodynamic states in 4 sheep with strictly quantified AR volumes were evaluated. A Toshiba SSH 380A with a 3.75-MHz transducer was used to image the FC and VC. After routine echo Doppler imaging, patients were repositioned in the right lateral decubitus position, and the FC and VC were imaged from high right parasternal windows. In only 15 of the 40 patients was it possible to image clearly and measure accurately the FC and VC from conventional (left decubitus) apical or parasternal views. In contrast, 31 of 40 patients had clearly imaged FC regions and VCs using the new windows. In patients, AR volumes derived from the FC and VC methods combined with continuous velocity agreed well with each other (r = 0.97, mean difference = -7.9 ml +/- 9.9 ml/beat). In chronic animal model studies, AR volumes derived from both the VC and the FC agreed well with the electromagnetically derived AR volumes (r = 0.92, mean difference = -1.3 +/- 4.0 ml/beat). By imaging from high right parasternal windows in the right decubitus position, complementary use of the FC and VC methods can provide clinically valuable information about AR volumes.
Three-dimensional reconstruction of the color Doppler-imaged vena contracta for quantifying aortic regurgitation: studies in a chronic animal model.
BACKGROUND: The purpose of this study was to investigate the use of 3-dimensional (3D) reconstruction of color Doppler flow maps to image and extract the vena contracta cross-sectional area to determine the severity of aortic regurgitation (AR) in an animal model. Evaluation of the vena contracta with 2-dimensional imaging systems may not be sufficiently robust to fully characterize this region, which may be asymmetrically shaped. METHODS AND RESULTS: In 6 sheep with surgically induced chronic AR, 18 hemodynamically different states were studied. Instantaneous regurgitant flow rates were obtained by aortic and pulmonary electromagnetic flowmeters (EMFs) as reference standards, and aortic regurgitant effective orifice areas (EOAs) were determined from EMF regurgitant flow rates divided by continuous-wave (CW) Doppler velocities. Composite video data for color Doppler imaging of the aortic regurgitant flows were transferred into a TomTec computer after computer-controlled 180 degrees rotational acquisition. After the 3D data transverse to the flow jet were sectioned, the smallest proximal jet cross section was identified for direct measurement of the vena contracta area. Peak regurgitant flow rates and regurgitant stroke volumes were calculated as the product of these areas and the CW Doppler peak velocities and velocity-time integrals, respectively. There was an excellent correlation between the 3D-derived vena contracta areas and reference EOAs (r=0.99, SEE=0.01 cm2) and between 3D and reference peak regurgitant flow rates and regurgitant stroke volumes (r=0.99, difference=0.11 L/min; r=0.99, difference=1.5 mL/beat, respectively). CONCLUSIONS: 3D-based determination of the vena contracta cross-sectional area can provide accurate quantification of the severity of AR.
Micromultiplane transesophageal echocardiographic probe for intraoperative study of congenital heart disease repair in neonates, infants, children, and adults.
This study reports the development of a micromultiplane 8.2-mm transesophageal echocardiographic probe. The probe is applicable to newborn infants and can deliver diagnostic images in adults.
Practical application of three-dimensional echocardiography in evaluation of atrial septal defects.
Explore the source record for details and available documents.
Validation of the accuracy of both right and left ventricular outflow volume determinations and semiautomated calculation of shunt volumes through atrial septal defects by digital color Doppler flow mapping in a chronic animal model.
OBJECTIVES: The aim of the present study was to quantitate shunt flow volumes through atrial septal defects (ASDs) in a chronic animal model with surgically created ASDs using a new semiautomated color Doppler flow calculation method (ACM). BACKGROUND: Because pulsed Doppler is cumbersome and often inappropriate for color flow computation, new methods such as ACM are of interest. METHODS: In this study, 13 to 25 weeks after ASDs were surgically created in eight sheep, a total of 24 hemodynamic states were studied at a separate open chest experimental session. Electromagnetic (EM) flow probes and meters were used to provide reference flow volumes as the pulmonary and aortic flow volumes (Qp and Qs) and shunt flow volumes (Qp minus Qs). Epicardial echocardiographic studies were performed to image the left and right ventricular outflow tract (LVOT and RVOT) forward flow signals. The ACM method digitally integrated spatial and temporal color flow velocity data to provide stroke volumes. RESULTS Left ventricular outflow tract and RVOT flow volumes obtained by the ACM method agreed well with those obtained by the EM method (r = 0.96, mean difference = 0.78 +/- 1.7 ml for LVOT and r = 0.97, mean difference = -0.35 +/- 3.6 ml for RVOT). As a result, shunt flow volumes and Qp/Qs by the ACM method agreed well with those obtained by the EM method (r = 0.96, mean difference = -1.1 +/- 3.6 ml/beat for shunt volumes and r = 0.95, mean difference = -0.11 +/- 0.22 for Qp/Qs). CONCLUSIONS: This animal study, using strictly quantified shunt flow volumes, demonstrated that the ACM method can provide Qp/Qs and shunt measurements semiautomatically and noninvasively.
Accuracy of Doppler methods for estimating peak-to-peak and peak instantaneous gradients across coarctation of the aorta: An In vitro study.
Although data exist that address the attempt to correlate noninvasive Doppler-derived pressure gradients with invasive catheter pressure gradients in patients with coarctation of the aorta, few data exist about stiffness of the proximal descending aorta (precoarctation) and its relation to these pressure measurements. In this study, an in vitro flow model of a simulated neonatal aorta with a coarctation was developed. Three proximal descending aortas of different stiffnesses were used. The stiffness index of the proximal descending aorta was calculated as beta = ln [systolic pressure/diastolic pressure/(systolic diameter - diastolic diameter)]. We evaluated pressure gradients obtained by continuous wave Doppler and standard catheter methods and looked at acceleration of flow velocity determined by pulsed wave Doppler in the 3 precoarctation segments of differing stiffnesses. Pressures in the proximal descending aorta (precoarctation) increased with increasing stiffness, ranging from 105 mm Hg (soft) to greater than 300 mm Hg (stiff). Continuous wave Doppler instantaneous pressure gradients overestimated the catheter instantaneous pressure gradients substantially (mean 41% +/- 19%). The stiffer the precoarctation segment, the more the degree of overestimation: soft, 0% to 63% (= 3.47); medium, 13% to 54% (beta = 4.42); and stiff, 43% to 66% (beta = 5.91). Inclusion of the precoarctation velocity [V1] component in the Bernoulli equation did not significantly improve the correlation or the agreement. An additional observation was that pullback catheter peak-to-peak gradients were higher than simultaneous peak-to-peak gradients. In the stiff aorta, this difference could be greater than 22 mm Hg (>19%). Acceleration of flow velocity toward the coarctation was evident by pulsed wave Doppler interrogation. Increasing the stiffness of the precoarctation segment also increased the degree of acceleration within this proximal segment: soft, 0.4 to 0.8 m/s; medium, 0.5 to 1. 4 m/s; and stiff, 0.7 to 1.5 m/s. These data suggest that increasing stiffness of the proximal descending aorta can alter the continuous wave detected Doppler gradient and although the gradient itself has increased, it may not predict accurately the true severity of the localized, most severely obstructed segment.
Evaluation of descending aortic flow volumes and effective orifice area through aortic coarctation by spatiotemporal integration of color Doppler data: An in vitro study.
Flow volumes in an in vitro model of the aorta with 3 different degrees of stiffness (stiff, moderately stiff, and compliant) proximal to a coarctation were calculated by using a digital color Doppler echocardiography flow calculation method that semiautomatically integrates spatial and temporal color flow velocity data. These flow volumes were compared with those obtained by the conventional pulsed Doppler method with reference to ultrasonic flowmeter. Flow volumes determined by the automated method agreed well with those obtained by ultrasonic flowmeter, even in this compliant aorta model with vessel size changing with pulsation, whereas the pulsed Doppler method overestimated the reference data, especially for more compliant descending aortic segments. The combination of flow data with continuous wave Doppler allows definition of effective orifice area for coarctation.
Flow convergence flow rates from 3-dimensional reconstruction of color Doppler flow maps for computing transvalvular regurgitant flows without geometric assumptions: An in vitro quantitative flow study.
OBJECTIVE: This study was designed to develop and test a 3-dimensional method for direct measurement of flow convergence (FC) region surface area and for quantitating regurgitant flows with an in vitro flow system. BACKGROUND: Quantitative methods for characterizing regurgitant flow events such as flow convergence with 2-dimensional color flow Doppler imaging systems have yielded variable results and may not be accurate enough to characterize those more complex spatial events. METHOD: Four differently shaped regurgitant orifices were studied: 3 flat orifices (circular, rectangular, triangular) and a nonflat one mimicking mitral valve prolapse (all 4 orifice areas = 0.24 cm(2)) in a pulsatile flow model at 8 to 9 different regurgitant flow rates (10 to 50 mL/beat). An ultrasonic flow probe and meter were connected to the flow model to provide reference flow data. Video composite data from the color Doppler flow images of the FC were reconstructed after computer-controlled 180 degrees rotational acquisition was performed. FC surface area (S cm(2)) was calculated directly without any geometric assumptions by measuring parallel sliced flow convergence arc lengths through the FC volume and multiplying each by the slice thickness (2.5 to 3.2 mm) over 5 to 8 slices and then adding them together. Peak regurgitant flow rate (milliliters per second) was calculated as the product of 3-dimensional determined S (cm(2)) multiplied by the aliasing velocity (centimeters per second) used for color Doppler imaging. RESULTS: For all of the 4 shaped orifices, there was an excellent relationship between actual peak flow rates and 3-dimensional FC-calculated flow rates with the direct measurement of the surface area of FC (r = 0.99, mean difference = -7.2 to -0.81 mL/s, % difference = -5% to 0%), whereas a hemielliptic method implemented with 3 axial measurements of the flow convergence zone from 2-dimensional planes underestimated actual flow rate by mean difference = -39.8 to -18.2 mL/s, % difference = -32% to -17% for any given orifice. CONCLUSIONS: Three-dimensional reconstruction of flow based on 2-dimensional color Doppler may add quantitative spatial information, especially for complex flow events. Direct measurement of 3-dimensional flow convergence surface areas may improve accuracy for estimation of the severity of valvular regurgitation.
Quantitative assessment of chronic aortic regurgitation with 3-dimensional echocardiographic reconstruction: comparison with electromagnetic flowmeter measurements.
Two-dimensional echocardiography and color Doppler are useful in the qualitative assessment of aortic regurgitation. However, color Doppler planar methods are not accurate in quantifying regurgitant flow, in part because of the complex geometry of aortic regurgitant flow events. Three-dimensional echocardiographic reconstruction is a new technique that provides dynamic 3-dimensional images of intracardiac color flow jets. We sought to determine whether the measurement of aortic regurgitant jet volume by 3-dimensional echocardiography correlated with the true regurgitant volume, measured by electromagnetic flowmeter in vivo, to accurately reflect the severity of aortic regurgitation. We performed volume-rendered 3-dimensional echocardiography in 6 sheep with surgically induced chronic eccentric aortic regurgitation. We obtained a total of 22 aortic regurgitation states by altering loading conditions. Instantaneous regurgitant flow rates were obtained by aortic and pulmonary electromagnetic flowmeters. The maximum aortic regurgitant jet volume by 3-dimensional echocardiography and the maximum jet area by 2-dimensional echocardiography were measured and compared with electromagnetic flowmeter data. By electromagnetic flowmeter, aortic regurgitant flow rate varied from 0.14 to 3.1 L/min (mean 1. 25 +/- 0.78); aortic regurgitant stroke volume varied from 1 to 34 mL/beat (mean 12 +/- 8), and regurgitant fraction varied from 3% to 42% (mean 25% +/- 12%). The maximum jet volume by 3-dimensional echocardiography correlated very well with the aortic regurgitant stroke volume (r = 0.92; P <.0001), with the mean regurgitant flow rate (r = 0.87; P <.0001), and with the regurgitant fraction (r = 0. 87; P <.0001) derived from electromagnetic flowmeter. Both intraobserver and interobserver variability on the measurement of the jet volume by 3-dimensional echocardiography were excellent (r = 0.98; P <.0001 and r = 0.90; P <.001, respectively). The maximum jet area by 2-dimensional echocardiography did not correlate with the aortic regurgitant stroke volume (r = 0.41; P = not significant) and related poorly with the regurgitant fraction (r = 0.52; P <.05) by electromagnetic flowmeter. Dynamic 3-dimensional echocardiography can allow better determination of the geometry of the aortic regurgitant jet and may assist of quantifying the severity of aortic regurgitation.
Acoustically stimulated transient power scattering explains enhanced detection of the very low velocities in myocardial capillaries by power Doppler imaging: an in vitro study.
BACKGROUND: Although enhanced detection of myocardial perfusion signals by power Doppler imaging during contrast echocardiography has been noted, flow velocities in the coronary microvasculature should generally be below the threshold for Doppler motion detection. It has been suggested that in this situation nonlinear scattering related to acoustically stimulated microsphere oscillation or destruction may be responsible for the detected Doppler shift. METHODS AND RESULTS: This study examined the behavior of MRX 115 (ImaRx Pharmaceuticals) microbubbles during harmonic and nonharmonic power Doppler imaging at varying power outputs (mechanical indexes 0. 3, 0.5, 0.7, and 0.9) in a perfusion tube model under zero-flow conditions. Boluses of MRX 115 0.5-mL suspension were introduced into the model, and flow was halted during each imaging period. Once power Doppler imaging was implemented, a signal was detected as unique sparkling color pixels corresponding to individual bubble destruction events, even in the absence of contrast movement. This phenomenon continued until all contrast bubbles disappeared from the region subjected to power Doppler imaging, usually within 35 to 40 seconds. Off-line videointensity measurements showed that initial power Doppler signal intensity and maximum signal decay rates increased parallel to increasing power output and were substantially greater for nonharmonic than for harmonic imaging modes. CONCLUSION: This relationship between signal intensity and decay rate and acoustic power output suggests that transient scattering related to bubble destruction is responsible for generation of the power Doppler signal in the absence of flow. This would explain the enhanced detection of the very low velocity flows in the myocardial capillaries by power Doppler contrast imaging.
Real-time three-dimensional echocardiography for determining right ventricular stroke volume in an animal model of chronic right ventricular volume overload.
BACKGROUND: The lack of a suitable noninvasive method for assessing right ventricular (RV) volume and function has been a major deficiency of two-dimensional (2D) echocardiography. The aim of our animal study was to test a new real-time three-dimensional (3D) echo imaging system for evaluating RV stroke volumes. METHODS AND RESULTS: Three to 6 months before hemodynamic and 3D ultrasonic study, the pulmonary valve was excised from 6 sheep (31 to 59 kg) to induce RV volume overload. At the subsequent session, a total of 14 different steady-state hemodynamic conditions were studied. Electromagnetic (EM) flow probes were used for obtaining aortic and pulmonic flows. A unique phased-array volumetric 3D imaging system developed at the Duke University Center for Emerging Cardiovascular Technology was used for ultrasonic imaging. Real-time volumetric images of the RV were digitally stored, and RV stroke volumes were determined by use of parallel slices of the 3D RV data set and subtraction of end-systolic cavity volumes from end-diastolic cavity volumes. Multiple regression analyses showed a good correlation and agreement between the EM-obtained RV stroke volumes (range, 16 to 42 mL/beat) and those obtained by the new real-time 3D method (r=0.80; mean difference, -2.7+/-6.4 mL/beat). CONCLUSIONS: The real-time 3D system provided good estimation of strictly quantified reference RV stroke volumes, suggesting an important application of this new 3D method.
Phase III multicenter trial comparing the efficacy of 2% dodecafluoropentane emulsion (EchoGen) and sonicated 5% human albumin (Albunex) as ultrasound contrast agents in patients with suboptimal echocardiograms.
OBJECTIVES: This study was performed to compare the safety and efficacy of intravenous 2% dodecafluoropentane (DDFP) emulsion (EchoGen) with that of active control (sonicated human albumin [Albunex]) for left ventricular (LV) cavity opacification in adult patients with a suboptimal echocardiogram. BACKGROUND: The development of new fluorocarbon-based echocardiographic contrast agents such as DDFP has allowed opacification of the left ventricle after peripheral venous injection. We hypothesized that DDFP was clinically superior to the Food and Drug Administration-approved active control. METHODS: This was a Phase III, multicenter, single-blind, active controlled trial. Sequential intravenous injections of active control and DDFP were given 30 min apart to 254 patients with a suboptimal echocardiogram, defined as one in which the endocardial borders were not visible in at least two segments in either the apical two- or four-chamber views. Studies were interpreted in blinded manner by two readers and the investigators. RESULTS: Full or intermediate LV cavity opacification was more frequently observed after DDFP than after active control (78% vs. 31% for reader A; 69% vs. 34% for reader B; 83% vs. 55% for the investigators, p < 0.0001). LV cavity opacification scores were higher with DDFP (2.0 to 2.5 vs. 1.1 to 1.5, p < 0.0001). Endocardial border delineation was improved by DDFP in 88% of patients versus 45% with active control (p < 0.001). Similar improvement was seen for duration of contrast effect, salvage of suboptimal echocardiograms, diagnostic confidence and potential to affect patient management. There was no difference between agents in the number of patients with adverse events attributed to the test agent (9% for DDFP vs. 6% for active control, p = 0.92). CONCLUSIONS: This Phase III multicenter trial demonstrates that DDFP is superior to sonicated human albumin for LV cavity opacification, endocardial border definition, duration of effect, salvage of suboptimal echocardiograms, diagnostic confidence and potential to influence patient management. The two agents had similar safety profiles.
Quantification of aortic regurgitant volume by a newly developed automated cardiac flow measurement method: an in vitro study.
BACKGROUND: Quantifying regurgitant volumes is important for treatment of patients with valvular aortic regurgitation. Simple, reliable methods to quantify aortic regurgitation have been sought both in the catheterization laboratory and the echocardiography laboratory. OBJECTIVES: The aim of our study was to investigate the applicability of a new automated cardiac flow measurement method with color Doppler velocity data for quantifying retrograde flow volumes of aortic regurgitation in an ascending aorta model. METHODS AND RESULTS: A 2-chamber pulsatile flow system with a modeled ascending aorta and a regurgitant aortic valve orifice was developed. The model could generate "aortic regurgitation-like" waveforms through the use of an electrically controlled valve. The regurgitant flows through the orifice (8.5 to 28.1 mL/beat) were measured by an ultrasound flowmeter; they were also calculated in the ascending aorta 1.0 cm above the orifice by the automated cardiac flow measurement method, which integrated spatially distributed digital flow velocity data through "diastole." Calculated regurgitant volumes measured with the low color Doppler filter (5.4 cm/s) agreed well with those measured with the flowmeter (r=.99, P < .001, mean difference=2.2+/-3.7 mL). However, the regurgitant volume was underestimated when 2 higher filter settings were used (9.6 and 10.9 cm/s). Although there was no significant difference in mean volume, higher frame rate (19 frames/s) provided more reproducible results with smaller standard deviation as compared with lower frame rate (7 frames/s). CONCLUSIONS: This new automated cardiac flow measurement method appears to be promising for semiautomatic quantification of aortic regurgitant volume. Appropriate choice of filter setting and high frame rate assists reliable data acquisition.
Evaluating isovelocity surface area flow convergence method with finite element modeling.
Through numerical experimentation we investigated the isovelocity surface area flow convergence method used in estimating regurgitant valve flow rates. Recent advances in three-dimensional color Doppler flow imaging have created renewed interest in this method. Experimentation was based on the use of depth-averaged finite element models of the left heart. The heart models studied varied from "synthetic" representations to a model of a left heart traced from an actual echocardiographic image of a patient with a prolapsed mitral valve. The isovelocity surface area flow convergence method overestimated regurgitant flow rates throughout the Nyquist limits considered with a critical Nyquist limit in which this overestimation is minimized. The angle dependence of Doppler color flow imaging partially corrects for this overestimation. The isovelocity surface area flow convergence method is a viable alternative to methods currently in use. Through numerical experimentation, we have begun to shed light on the inaccuracies inherent in this flow convergence method.
What is the validity of continuous wave Doppler grading of aortic regurgitation severity? A chronic animal model study.
Continuous wave Doppler methods have been widely used clinically for evaluating the severity of aortic regurgitation; however, there have been no studies comparing these continuous wave Doppler methods with a strictly quantifiable reference for regurgitant severity. The purpose of this study was to test the applicability of continuous wave Doppler methods (deceleration slope and pressure half-time) for evaluation of chronic aortic regurgitation in an animal model. Eight sheep were studied 8 to 20 weeks after surgery to create chronic aortic regurgitation. Twenty-nine hemodynamically different states were obtained pharmacologically. A Vingmed 775 system was used for recording continuous wave Doppler traces with a 5 MHz annular array transducer directly placed on the heart near the apex. The aortic regurgitation was quantified as peak and mean regurgitant flow rates, regurgitant stroke volumes and regurgitant fractions determined with pulmonary and aortic electromagnetic flow probes and meters balanced against each other. Peak regurgitant flow rates varied from 1.8 to 13.6 L/min (6.3 +/- 3.2 L/min) (mean +/- SD), mean regurgitant flow rates varied from 0.7 to 4.9 L/min (2.7 +/- 1.3 L/min), regurgitant stroke volume varied from 7.0 to 48.0 ml/beat (26.9 +/- 12.2 ml/beat), and regurgitant fraction varied from 23% to 78% (53% +/- 16%). Only marginal correlations were obtained between reference indexes and continuous wave Doppler deceleration slope and pressure half-time (r = 0.55 to 0.74). A deceleration slope greater than 3 m/sec2 and pressure half-time less than 400 msec did, however, provide 100% specificity for detecting severe AR (regurgitant fraction > 50%). Our study shows that the continuous wave Doppler deceleration slope and pressure half-time methods have limited use for quantifying aortic regurgitation.
Diagnostic accuracy and role of intraoperative biplane transesophageal echocardiography in pediatric patients with left ventricle outflow tract lesions.
OBJECTIVES: To define the lesion-specific role of biplane transesophageal echocardiography in children with left ventricular outflow tract obstructive lesions, the diagnostic accuracy of transthoracic and transesophageal images were compared, and the impact of transesophageal echocardiography on perioperative management was evaluated. BACKGROUND: The reported high postoperative recurrence of left ventricular outflow tract obstructive lesion can be due to its incomplete surgical relief. A full preoperative definition of the lesions would aid in better surgical outcome. The complexity and spectrum of such lesions provide opportunity to evaluate the role of a recently available biplane transesophageal pediatric probe in its diagnosis and surgical management. METHODS: In 16 consecutive patients (11 male patients) with left ventricular outflow tract obstructive lesions and with a mean age of 7.9 +/- 5.7 years (range 0.25 to 20.0 years) and a mean weight of 29 +/- 19 kg (range 4 to 66 kg), the morphologic and hemodynamic findings of standard preoperative transthoracic and intraoperative biplane transesophageal echocardiography were compared with surgical and cardiac catheterization findings (in seven patients) for the diagnostic accuracy and impact on the surgical management of the lesions. RESULTS: Based on the levels of agreement, transesophageal echocardiography demonstrated higher diagnostic sensitivity (chi-squared analysis = 13.4 < 0.001) to the presence and extent of associated lesions (septal hypertrophy, multiple fibromuscular insertions, involvement of aortic and mitral valves not revealed by transthoracic imaging) and trend toward higher sensitivity (Fisher's exact p = 0.17) to primary morphologic diagnoses (abnormal chordal attachments, prolapsed aortic cusp, and tunnel-like outflow tract obstructive lesions missed by transthoracic imaging). As a result of these factors, intraoperative transesophageal imaging changed the surgical plan in 25% of the patients and modified it in an additional 25% of the patients. CONCLUSIONS: Transesophageal echocardiography can be a reliable diagnostic tool and has an important role in the surgical management of left ventricular outflow tract lesions in children.