Search PubMed⌕ Search

PubMed · 10795338

Categorizing risks for risk ranking.

Abstract

Any practical process of risk ranking must group hazards into a manageable number of categories. Defining such categories requires value choices that can have important implications for the rankings that result. Most risk-management organizations will find it useful to begin defining categories in terms of environmental loadings or initiating events. However, the resulting categories typically need to be modified in light of other considerations. Risk-ranking projects can benefit from considering several alternative categorization strategies and drawing upon elements of each in developing their final categorization of risks. In principle, conducting multiple ranking exercises by using different categorizations could be interesting and useful. In practice, agencies are unlikely to have either the resources or patience to do this, but other groups in society might. Done well, such additional independent rankings could add valuable inputs to democratic risk-management decision making.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M G Morgan, H K Florig, M L DeKay, P Fischbeck. 2000. Categorizing risks for risk ranking.. https://doi.org/10.1111/0272-4332.00005

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Indoor air quality at nine shopping malls in Hong Kong.

Hong Kong is one of the most attractive shopping paradises in the world. Many local people and international tourists favor to spend their time in shopping malls in Hong Kong. Good indoor air quality is, therefore, very essential to shoppers. In order to characterize the indoor air quality in shopping malls, nine shopping malls in Hong Kong were selected for this study. The indoor air pollutants included carbon dioxide (CO2), carbon monoxide (CO), total hydrocarbons (THC), formaldehyde (HCHO), respirable particulate matter (PM10) and total bacteria count (TBC). More than 40% of the shopping malls had 1-h average CO2 levels above the 1000 ppm of the ASHRAE standard on both weekdays and weekends. Also, they had average weekday PM10 concentrations that exceeded the Hong Kong Indoor Air Quality Objective (HKIAQO). The highest indoor PM10 level at a mall was 380 microg/m3. Of the malls surveyed, 30% had indoor airborne bacteria levels above 1000 cfu/m3 set by the HKIAQO. The elevated indoor CO2 and bacteria levels could result from high occupancy combined with insufficient ventilation. The increased PM10 levels could be probably attributed to illegal smoking inside these establishments. In comparison, the shopping malls that contained internal public transport drop-off areas, where vehicles were parked with idling engines and had major entry doors close to heavy traffic roads had higher CO and PM10 indoor levels. In addition, the extensive use of cooking stoves without adequate ventilation inside food courts could increase indoor CO2, CO and PM10 levels.

Air Pollution, Indoor↗

Effects of surface type and relative humidity on the production and concentration of nitrous acid in a model indoor environment.

A nested chamber design was constructed for the purpose of studying parameters that affect indoor air chemistry. Experiments were conducted in this system to investigate the effects of three surface types (Teflon, wallpaper, and carpet) and two levels of relative humidity (50% and 70% RH) on the formation of gas-phase nitrous acid (HONO) through the heterogeneous reaction of nitrogen dioxide (NO2) with sorbed water vapor. The results of this investigation show that, compared with Teflon surfaces, carpet made of synthetic fibers increased the NO2 surface removal rate by nearly an order of magnitude and resulted in higher peak HONO concentrations. The results also suggest that the capacity of a surface to sorb water will determine if HONO is released from that surface after the NO2 source has been turned off and the heterogeneous reaction between NO2 and sorbed water is no longer significant. Vinyl-coated wallpaper was found to release HONO for prolonged periods of time after the NO2 source was turned off at both 50% and 70% RH whereas Teflon was found to do so only at 70% RH. The results of this investigation also demonstrate the utility of the nested chamber design in investigating indoor air chemistry.

Air Pollution, Indoor↗

Mercury vapour release from a dental aspirator.

OBJECTIVE: To investigate the release of mercury vapour from a dental aspirator which vented its waste air through its base directly into the surgery environment. METHODOLOGY: Mercury vapour in air concentrations were measured at the breathing zone of the dentist during continuous operation of the aspirator. Further series of mercury vapour measurements taken at the aspirator exhaust vent were carried out to determine the sources of mercury vapour from this particular device. RESULTS: At the dentist's breathing zone, mercury vapour concentrations of ten times the current occupational exposure limit of 25 micrograms/m3 were recorded after 20 minutes of continuous aspirator operation. A build up of amalgam contamination within the internal corrugated tubing of the aspirator was found to be the main source of mercury vapour emissions followed by particulate amalgam trapped within the vacuum motor. As the vacuum motor heated up with run time, mercury vapour emissions increased. It was found that the bacterial air exhaust filter (designed to clean the contaminated waste air entering the surgery) offered no protection to mercury vapour. In this case the filter trapped particulate amalgam which contributed to further mercury vapour contamination as high volume air was vented through it. CONCLUSION: It is not known how many dental aspirators are in use that vent their waste air directly into the surgery or if this aspirator is representative of others in existence. The safety of dental aspirating systems with regard to mercury vapour exposure requires further investigation.

Air Pollution, Indoor↗