Search PubMed⌕ Search

PubMed · 10375488

Studies in calf venous pump function utilizing a two-valve experimental model.

Abstract

OBJECTIVES: to explore the hydrodynamic mechanisms involved in the regulation of ambulatory venous pressure. DESIGN: an experimental model of calf venous pump was constructed with collapsible tubes and valves. MATERIAL: the model consisted of a conduit and a pump with an intervening competent valve. Another valve that could allow reflux into the pump was mounted above the pump. METHODS: conduit pressure and recovery times were monitored under conditions of different degrees of ejection fraction and reflux into the pump. Model variables included using poorly compliant tubes for the pump, the conduit and for both the pump and conduit. RESULTS: the latex tube exhibited a non-linear volume-pressure relationship and a bi-modal regimen of compliance. This bestowed pressure-buffering properties. Ambulatory venous hypertension resulted when reflux beyond buffering capacity occurred. Substituting less compliant PTFE for latex at the pump had a relatively minor effect on post-ejection pressure and recovery times. Using PTFE at the conduit had a profound but divergent effect on both of these parameters. Conduit capacitance reduction had a similar effect. CONCLUSION: conduit elastance plays a significant role in the regulation of ambulatory venous pressure in this experimental model. The hydrodynamic principles illustrated by the model may enhance our understanding of the human calf venous pump.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Raju, C A Hudson, R Fredericks, P Neglén, A B Greene, E F Meydrech. 1999. Studies in calf venous pump function utilizing a two-valve experimental model.. https://doi.org/10.1053/ejvs.1999.0818

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Central venous pulse pressure analysis using an R-synchronized pressure measurement system.

OBJECTIVE: The information derived from central venous catheters is underused. We developed an EKG-R synchronization and averaging system to obtained distinct CVP waveforms and analyzed components of these. METHODS: Twenty-five paralyzed surgical patients undergoing CVP monitoring under mechanical ventilation were studied. CVP and EKG signals were analyzed employing our system, the mean CVP and CVP at end-diastole during expiration were compared, and CVP waveform components were measured using this system. RESULTS: CVP waveforms were clearly visualized in all patients. They showed the a peak to be 1.8+/- 0.7 mmHg, which was the highest of three peaks, and the x trough to be lower than the y trough (-1.6+/- 0.7 mmHg and -0.9+/- 0.5 mmHg, respectively), with a mean pulse pressure of 3.4 mmHg. The difference between the mean CVP and CVP at end-diastole during expiration was 0.58+/- 0.81 mmHg. CONCLUSIONS: The mean CVP can be used as an index of right ventricular preload in patients under mechanical ventilation with regular sinus rhythm. Our newly developed system is useful for clinical monitoring and for education in circulatory physiology.

Blood Pressure Determination↗

Beyond inpatient and outpatient care: alternative model for hypertension management.

Hypertension is a major contributor to worldwide cardiovascular mortality, however, only one-third of patients with hypertension have their blood pressure treated to guideline recommended levels. To improve hypertension control, there may need to be a fundamental shift in care delivery, one that is population-based and simultaneously addresses patient, provider and system barriers. One potential approach is home-based disease management, based on the triad of home monitoring, team care, and patient self-care. Although there may be challenges to achieving the vision of home-based disease management, there are tremendous potential benefits of such an approach for reducing the global burden of cardiovascular disease.

Blood Pressure Determination↗