Structural evaluation of human and sheep bone and comparison with synthetic hydroxyapatite by FT-Raman spectroscopy.

The composition of whole human and sheep cortical bone tissue, and of a synthetic hydroxyapatite (P120), were compared using Fourier transform Raman (FT-Raman) spectroscopy. Deproteination procedures to remove the bulk of the collagen present in bone tissue allowed isolation of the mineral phase. A comparison of the spectra obtained from both whole and deproteinated bone with those of synthetic hydroxyapatite showed direct correlation only in the region of 952 cm-1 (symmetric P-O mode). In contrast, human and sheep bone were very closely matched in both, the organic and inorganic structures. The results demonstrate that deproteination of bone is not a necessary precursor to obtain spectral information.

Animals↗

Water absorption characteristics of modified hydroxyapatite bone cements.

Water absorption characteristics of a range of modified hydroxyapatite (HA)-reinforced poly(ethyl methacrylate)-n-butyl methacrylate (PEMA-nBMA) bone cements have been established. From gravimetric measurements, the kinetics of successive absorption and desorption cycles, equilibrium uptake, diffusion coefficients and solubility data have been determined. In general, the water uptake could be modelled by the classical laws of diffusion. The introduction of the HA reduced the water uptake of the bone cement, with a further decrease if the HA filler was surface treated with a silane coupling agent. However, the system comprising the silicated silanated HA-filled cement produced a large uptake of water, with relatively low diffusion coefficients, which is attributed to the presence of soluble sites in the matrix.

Absorption↗

Is stem length important in uncemented endoprostheses?

In an uncemented total hip replacement where the femoral stem is thinner than the medullary canal it may be hypothesized that the distal portion of the stem has no mechanical function. In this study an uncemented total hip replacement has been modelled mathematically using finite element analysis and mechanical tests of a similar system have been carried out loading implants in cadaveric proximal femora. Two implants have been tested mechanically; one with a full length stem and the second with the stem shortened, but three implants have been modelled with an additional intermediate length stem analysed. Additionally the finite element analysis has been done with a high neck resection and a standard level resection. The finite element model showed that the full length stem produced lower interface contact stress levels under the proximal neck, particularly when the nec was resected, and this was borne out by the mechanical testing.

Biomechanical Phenomena↗

Analysis of surface layers on bioactive glasses.

FT-Raman spectroscopy proves to be a powerful technique to study surface reactions on bioactive glasses and it eliminates the fluorescence of the organic phase of whole bone, thereby making it possible to compare the reaction layers formed on bioactive glasses with the mineral phase of bone. The spectrum of hydroxycarbonate apatite (HCA) developed on the bioactive glasses is closer to that of bone than synthetic hydroxyapatite (HA) and closely matches that of bone mineral obtained by deproteination of whole human femoral cortical bone.

Apatites↗

Development of a glass reinforced hydroxyapatite with enhanced mechanical properties. The effect of glass composition on mechanical properties and its relationship to phase changes.

Utilizing glasses of the types xNa2O-(1-x)P2O5 and xCaO-(1-x)P2O5 (where x = 0.2, 0.3, and 0.5), a systematic study of the effect of increasing network modifying oxides in glasses was made on the mechanical properties of a glass reinforced hydroxyapatite, at glass additions of 2.5 and 5 wt%. For the soda type glass, phase changes were promoted much more readily compared to the lime type glass. This was true for both 2.5 and 5 wt% additions of glass. For the lime type glass, considerable differences between the effects of 2.5 and 5 wt% additions were seen. At 5 wt%, the increased amount of liquid phase present promotes an increased level of phase inversion to alpha and beta tricalcium phosphate. At 2.5 wt%, a larger percentage of the HA remains stable at higher temperatures. Furthermore, the effect of the composition may be seen. As the mol% of network forming oxide increases, (i.e., the Ca/P ratio moves towards 1.67, (the ratio for HA) the HA remains more stable. This is seen in the maintenance of both the HA phase and also the enhanced mechanical properties.

Biocompatible Materials↗

Predictive modelling of hydroxyapatite-polyethylene composite.

A predictive model for hydroxyapatite-reinforced polyethylene composite has been developed using the finite element analysis method. The simulation is based on the analysis of a representative cell. Results for the complete material can be derived using a spatial statistical material model. Predicted values of Young's modulus are found to be in reasonable agreement with experimentally measured values over a wide range of hydroxyapatite volume fraction. The predictive model can be used to investigate the micromechanical behaviour of the material. This investigation leads to significant elucidation of the failure processes for this material.

Biocompatible Materials↗

Hydrogels as an interface between bone and an implant.

The use of fully hydrated hydrogels in the body has been well established. The forces a hydrogel generates on swelling when it is placed in a constrained space were investigated with a view to providing a mechanism for fixing a prosthesis in the intramedullary cavity. A cross-linked poly(2-hydroxyethyl methacrylate) [p(HEMA)] hydrogel was investigated as a potential material. In vitro mechanical tests were carried out to determine the stresses generated in the p(HEMA) when it was placed in water and not allowed to swell. Pull out loads of up to 375 N indicated that the system could be used successfully in vivo. Consequently, the material was placed intraosseously at two sites in a rabbit animal model, in the mid-shaft (diaphysis) and the lower end (metaphysis) of the femur. Histological examination showed there was no adverse bone response; bone was growing from the endosteal surface up to and into the hydrogel in the diaphyseal implants and surrounded the hydrogel in the metaphysis. As a result of the shape and size variations in the rabbit femur, in vivo mechanical tests were found to give lower values than those obtained in vitro.

Animals↗

Factors affecting the strength of flexor tendon repair.

The effects of different thicknesses and configurations of core sutures were studied in human cadaveric flexor tendon repairs. Both straight and cyclic load tests were employed. To exploit the full strength of 4/0 suture material, the Kessler repair using four locked single knots would seem to be appropriate.

Biomechanical Phenomena↗

The response of equine cortical bone to loading at strain rates experienced in vivo by the galloping horse.

The behaviour of cortical bone under load is strain rate-dependent, i.e. it is dependent on the rate at which the load is applied. This is particularly relevant in the galloping horse since the strain rates experienced by the bone are far in excess of those recorded for any other species. In this study the effect of strain rates between 0.0001 and 1 sec-1 on the mechanical properties of equine cortical bone were assessed. Initially, increasing strain rates resulted in increased mechanical properties. Beyond a critical value, however, further increases in strain rate resulted in lower strain to failure and energy absorbing capacity. This critical rate occurred around 0.1 sec-1 which is within the in vivo range for a galloping racehorse. Analysis of the stress-strain curves revealed a transition in the type of deformation at this point from pseudo-ductile to brittle. Bones undergoing brittle deformation are more likely to fail under load, leading to catastrophic fracture and destruction of the animal.

Animals↗

In vitro and in vivo evaluation of polyhydroxybutyrate and of polyhydroxybutyrate reinforced with hydroxyapatite.

Polyhydroxybutyrate (PHB) is a polyester made by many microorganisms under conditions of nitrogen deficiency, and is produced commercially in bulk by biotechnology. It has been suggested that PHB-based materials (copolymers and composites) could be suitable for medical applications and may be biodegradable. This paper presents some findings regarding the degradation and biological properties of polyhydroxybutyrate and composites reinforced with particulate hydroxyapatite. It has been established that the strength and stiffness of these materials reduce on in-vitro environment exposure in phosphate-buffered saline at 37 degrees C for periods up to 4 months, and that the degradation rate is a function of composition and processing conditions. It has also been demonstrated that materials based on PHB produce a consistent favourable bone tissue adaptation response with no evidence of an undesirable chronic inflammatory response after implantation periods up to 12 months. Bone is rapidly formed close to the material and subsequently becomes highly organized, with up to 80% of the implant surface lying in direct apposition to new bone. The materials showed no conclusive evidence of extensive structural breakdown in vivo during the implantation period of the study.

Animals↗

Measurement of the density of trabecular bone.

Methods of assessing real and apparent trabecular bone density are discussed. A method of defatting trabecular bone using trichlorethylene in an ultrasound bath for 4 h followed by rehydration in distilled water under vacuum is described, and its effectiveness discussed.

Bone Density↗

Fracture mechanics of bone with short cracks.

Tensile fracture experiments were performed upon specimens of wet mature bovine Haversian bone, with short, controlled notches. Stress concentration factors were found to be significantly less than values predicted using a maximum stress criterion in the theory of elasticity. Results were also modeled with the aid of linear elastic fracture mechanics. Agreement of experiment with theory was better in this case, however deviations were seen for short notches. Two mechanisms were evaluated for the behavior: plasticity near the crack tip, and effects of the Haversian microstructure, modelled by Cosserat elasticity, a generalized continuum theory. Plastic zone effects were found to be insignificant. Cosserat elasticity, by contrast, predicted stress concentration factors which better approximated observed values. To explore strain redistribution processes, further experiments were conducted upon notched specimens in torsion at small strain. They disclosed a strain redistribution effect consistent with Cosserat elasticity. These microelastic effects were attributed to the Haversian architecture of bone. The implications of the results are that bone resists the effect of stress raisers such as fatigue microcracks and surgical sawcuts to a much greater extent than anticipated on the basis of its elastic or elastoplastic properties.

Animals↗

A contact method for the assessment of ultrasonic velocity and broadband attenuation in cortical and cancellous bone.

A portable system using a direct contact for the measurement of ultrasonic velocity and broadband attenuation in bone is described (contact ultrasonic bone analyser, CUBA). Soft-tissue compensation is performed using an ultrasonic pulse-echo technique. CUBA has been successfully validated using reference materials, the precision of velocity and broadband attenuation measurements being typically 0.2% and 0.5% respectively. The clinical reproducibility has been assessed on the equine third metacarpal bone. The reproducibility of velocity measurement is typically 0.5% for cortical bone and 1% for cancellous bone. For broadband attenuation the reproducibility is typically 7% for cortical bone and 6% for cancellous bone. The lower reproducibility of the attenuation data is attributed to the high sensitivity to variations in the material properties of bone with small changes in transducer positioning. Coupling difficulties through an intact equine coat have been overcome and the system may now be assessed in the clinical environment, in both human and animal populations.

Animals↗

Orientation dependence of the fracture mechanics of cortical bone.

The fracture mechanics parameter of the critical stress intensity factor (Kc) was determined by a modified compact tension test method, for the fracture of bovine tibia cortical bone at orientations of 0 degrees, 15 degrees, 30 degrees, 45 degrees, 75 degrees and 90 degrees to the bone axis. It was established that, for a given loading rate, a variation in orientation from 0-90 degrees produced average increases in Kc from 3.2 to 6.5 MN m-3/2.

Animals↗

Torsional stability of the femoral component of hip arthroplasty. Response to an anteriorly applied load.

Torsional instability of femoral components has not received much attention, and is difficult to detect in conventional radiographs. To test this we designed a system to apply a load in an anteroposterior direction to the head of a femoral component, implanted into a cadaveric femur. Rotation within the bone was measured, using a purpose built transducer, with and without preservation of the neck, with and without cement, and with longitudinal ridges but no cement. The results show that torsional instability may be a problem in uncemented replacement. Preservation of the femoral neck and the use of a ridged prosthesis increases resistance to rotation. Rotational movements occurring in vivo during such activities as climbing stairs and rising from the seated position may contribute to mechanical loosening.

Biomechanical Phenomena↗

Composites for bone replacement.

The application of synthetic materials for bone replacement is now well established, but it is recognized that mechanical compatibility, as well as biocompatibility, of the tissue and implant is required if stress shielding and consequent bone resorption is to be avoided at areas of fixation. The development of materials analogous to the natural tissue for longer term implantation is discussed, with particular reference to hydroxyapatite reinforced polymers.

Biocompatible Materials↗