Search PubMed⌕ Search

Biomedical subjects

W Bonfield

Publications and source records attributed to W Bonfield.

At least 91 records · Page 5Linked to original sources

Histomorphological and biomechanical characterization of calcium phosphates in the osseous environment.

The standardization of characterization techniques is becoming increasingly important for bone replacement materials as it becomes apparent that, for the field to advance, testing must be developed to allow the biocompatibility or bioactivity of a new material to be assessed and directly compared with existing materials. Currently there are many forms of biocompatibility test for materials destined for the osseous environment, ranging from immersion in simulated body fluid to implantation into living bone. However, the variety of ways in which the data from these tests may be acquired and interpreted, as a result of changes in parameters such as surgical technique and mechanical test conditions, means that much of the published data within the field is not comparable. This paper will introduce the concept of biocompatibility by considering calcium phosphate bioceramics, and discusses some aspects of in vivo experimental design, including simple histomorphometry techniques, in addition to considering practical methods for the assessment of the biomechanical characteristics of an osseointegrated implant.

Animals↗

Effect of crosslinking agents on acrylic bone cements based on poly(methylmethacrylate).

Three different crosslinking agents were added to the monomer content of the bone cement formulation based on poly(methylmethacrylate), PMMA, in various concentrations, and their effects on the curing parameters and mechanical properties were determined. The different crosslinking agents were dimethacrylates containing a range of chain lengths and degrees of flexibility. For the parent formulation of the bone cement, PMMA powder was used, and the properties and kinetics of curing were compared for the same system with and without crosslinking agents. It was found that at low concentrations of crosslinking agents, the mechanical properties were superior but steadily decreased with increasing concentrations. Poly(ethyleneglycoldimethacrylate), EGDMA(400), even when used at very low concentrations, produced a steady improvement in the mechanical properties and could be used in cement formulations with a view to reducing creep and improving mechanical properties.

Acrylates↗

Crack growth resistance in cortical bone: concept of microcrack toughening.

The role of microcracking in cortical bone as a toughening mechanism has been investigated in conjunction with the variation in fracture toughness with crack length. Fracture toughness tests were conducted on miniaturised compact tension specimens made from human and bovine cortical bone and the resultant microstructural damage, present in the form of microcracking on the surface, was analysed around the main propagating crack. It was found that the fracture toughness (Kc) and the cumulative number of microcracks increased linearly with crack extension in human and bovine cortical bone, although both Kc and number of microcracks were considerably higher in the latter case. Based on these results, a mechanism, derived from the resistance (R) curve concept developed for microcracking brittle solids, is proposed to explain the fracture of cortical bone, with microcracking distributed between a frontal process zone and a significant process zone wake. Evidence to support this mechanism is given from the existing bone literature, detailed scanning electron microscopical observations and the distribution of microcracks in the process zone wake.

Adult↗

Biomechanical assessment of bone ingrowth in porous hydroxyapatite.

Porous hydroxyapatite (Endobon) specimens were implanted into the femoral condyle of New Zealand White rabbits for up to 6 months. After sacrifice, specimens were sectioned for histology and mechanical testing, where the extent of reinforcement by bony ingrowth was assessed by compression testing and fixation was assessed by push-out testing. From histological observations, it was established that the majority of bone ingrowth occurred between 10 day and 5 weeks after implantation and proceeded predominantly from the deep end of the trephined defect, with some integration from the circumferential sides. At 3 months, the implants were fully integrated, exhibiting bony ingrowth, vascularization and bone marrow stroma within the internal macropores. After 5 weeks, the mean ultimate compressive strength of retrieved implants (6.9 MPa) was found to be greater than that of the original implant (2.2 MPa), and by 3 months the fully integrated implants attained a compressive strength of approximately 20 MPa. Push-out testing demonstrated that after 5 weeks in vivo, the interfacial shear strength reached 3.2 MPa, increasing to 7.3 MPa at 3 and 6 months.

Journal Article↗

In vitro mechanical and biological assessment of hydroxyapatite-reinforced polyethylene composite.

In vitro performance of hydroxyapatite (HA)-reinforced polyethylene (PE) composite (HAPEX) has been characterized from both mechanical and biological aspects. The mechanical properties of HAPEX, such as tensile strength and Young's modulus, showed little change after immersion in a physiological solution at 37 and 70 degrees C for various periods. In addition, the biological response of primary human osteoblast-like (HOB) cells in vitro on HAPEX was assessed by measuring DNA synthesis and osteoblast phenotype expression. Cell proliferation rate on HAPEX was demonstrated by an increase in DNA content with time. A high tritiated thymidine ([3H]-TdR) incorporation/DNA rate was observed on day 1 for HAPEX, indicating a stimulatory effect on cell proliferation. The alkaline phosphatase (ALP) activity was expressed earlier on HAPEX than on unfilled PE and increased with time, indicating that HOB cells had commenced differentiation. Furthermore, it was found that the HA particles in the composite provided favourable sites for cell attachment. It appears that the presence of HA particles in HAPEX may have the advantage of acting as microanchors for bone bonding in vivo.

Journal Article↗

Influence of Ringer's solution on creep resistance of hydroxyapatite reinforced polyethylene composites.

In vitro creep studies of polyethylene, both unfilled and filled with hydroxyapatite at 0.20 and 0.40 volume fraction, have been performed. The samples were immersed in Ringer's solution at 37 degrees C for 1, 7, 30, 90 and 150 days prior to isochronous and creep tests in the same condition. The creep properties of unfilled polyethylene is unaffected by the immersion, but the isochronous modulus and the creep resistance of filled polyethylene were reduced. The effect increased with increasing volume fraction and time of immersion. This reduction is related to the penetration of the solution into the material, softening the interface.

Journal Article↗

Preparation and characterization of fluoride-substituted apatites.

Apatites were prepared with three different fluoride concentrations: 0.0 mM (pure hydroxyapatite) 2.5 mM and 5 mM. Reactions were performed in aqueous medium using a reaction between diammonium orthophosphate and calcium nitrate 4-hydrate and ammonium fluoride at temperatures of 3 degrees, 25 degrees, 60 degrees and 90 degrees C. The effects of reaction temperature and fluoride concentration on the crystal morphology, phase purity and crystallinity of the precipitates were observed, using transmission electron microscopy (TEM), X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscopy and ion chromatography. Transmission electron micrographs revealed that the crystallites precipitated at 3 degrees C were spheroidal, but became increasingly acicular with increasing precipitation temperature. X-ray diffraction results indicated that all the materials produced were phase pure and that the crystallinity of apatites prepared at higher precipitation temperatures was higher than those prepared at lower precipitation temperatures. A significant difference in the a-axis dimension of fluoride-substituted apatites was observed, as compared to hydroxyapatite. FTIR spectroscopy revealed a hydroxyl band at 3568 cm-1, along with a broad peak of adsorbed water in the region of 3568 cm-1 to 2670 cm-1 in the hydroxyapatite and fluoride-substituted apatite powders. Hence by careful selection of the precipitation conditions and fluoride contents, the composition and morphology of fluoride-substituted apatite may be controlled and this has interesting implications for the development of these materials for biomedical implantation.

Journal Article↗

Influence of sterilization upon a range of properties of experimental bone cements.

Bone cement, used to fix prostheses into the bone, must be sterilized prior to implantation. Two sterilization techniques, gamma and beta radiation, were investigated, examining the influence upon molecular weight, static and dynamic mechanical characteristics and rheological properties. A number of experimental cements were studied prepared from methylmethacrylate (MMA) co-polymers, either single powders or powder blends, mixed with MMA monomer. It was found that with both gamma and beta radiation, there was a decrease in molecular weight of all powders, including a MMA/styrene co-polymer, in relation to the radiation dose. This fall in molecular weight resulted in a drop in tensile strength, Young's modulus and strain to failure of all cements tested. However, the deterioration in mechanical strength was highlighted by the dynamic testing. Fatigue lives of cements after testing in tension-tension, at 2 Hz under load control and irradiated with 25 kGy gamma radiation, displayed significant decreases. This result indicated the utmost importance of conducting such tests upon experimental bone cements prior to in vivo use. The rheological time profiles of curing cements were also found to be influenced by 25 kGy gamma radiation, with a reduction of complex viscosity after sterilization.

Journal Article↗

Optimization of benzoyl peroxide concentration in an experimental bone cement based on poly(methyl methacrylate).

The effect of the concentration of benzoyl peroxide in poly(methyl methacrylate) bone cement formulations on their setting characteristics, particularly peak temperature and setting time, were studied. An optimization of the concentration of benzoyl peroxide was made with respect to curing parameters and compared with the residual monomer content. The mechanical properties of the different formulations were also determined and the results indicated that a composition of 1.5% wt/wt and 0.82% wt/wt of benzoyl peroxide and N,N-dimethyl-p-toluidine concentrations, respectively, gave the highest yield strength. Studies on the preparation of bone cement formulations containing different amounts of barium sulphate were also performed to assess the effect on the polymerization process and mechanical properties of the cements.

Journal Article↗

Characterization of hydroxyapatite and carbonated apatite by photo acoustic FTIR spectroscopy.

An understanding of the interfacial relationship between a bioceramic implant and the adjacent bone tissue is facilitated by precise characterization of the associated structures. The structure of different commercial synthetic hydroxyapatite powders and a novel carbonated apatite have been studied with photo-acoustic (PAS) Fourier transform infrared (FTIR) spectroscopy. The PAS technique is an ideal method for analysing biomaterials, as materials can be analysed without the need to reduce the particle size or to dilute with KBr. Spectra from carbonated apatite appear to be different from those of commercial hydroxyapatite powders, with the main difference lying in the carbonate and phosphate ratio. Commercial hydroxyapatite powders from different sources have also been analysed and compared.

Journal Article↗

Evaluation of in vitro bioactivity and biocompatibility of Bioglass-reinforced polyethylene composite.

The bioactivity and biocompatibility of Bioglass-reinforced high-density polyethylene composite (Bioglass/HDPE) have been evaluated in simulated body fluid (SBF) and by in vitro cell culture, respectively. The formation of a biologically active hydroxy-carbonate apatite (HCA) layer on the composite surface after immersion in SBF was demonstrated by thin-film X-ray diffraction, infrared spectroscopy and scanning electron microscopy, indicating the in vitro bioactivity of Bioglass/HDPE composites. The HCA layer was formed on the 40 vol% composite surface within 3 days immersion in SBF at a formation rate comparable to those on bioactive glass-ceramics, showing that in vitro bioactivity could be obtained in a composite. Furthermore, the composite was biocompatible to primary human osteoblast-like cells. In comparison with unfilled HDPE and tissue culture plastic control, a significant increase in cellular metabolic activity was found on the composite. Therefore, Bioglass/HDPE composites have a promising biological response as a potential implant material.

Journal Article↗

Morphology and ultrastructure of the interface between hydroxyapatite-polyhydroxybutyrate composite implant and bone.

A composite of polyhydroxybutyrate (PHB) polymer, reinforced with synthetic hydroxyapatite (HA) particles, with potential as a bone-analogue material, was examined microscopically using scanning electron microscopy and transmission electron microscopy. These imaging techniques provide the means of understanding and monitoring the morphological and structural behaviour of retrieved implants. Scanning electron microscopy was used to assess the overall mechanism of new bone formation at the implant interface after up to 6 months implantation. This procedure was followed by a detailed ultrastructural examination at lattice plane resolution level, using high resolution electron microscopy and selected area diffraction of the regions showing bone apposition. Fine hydroxyapatite crystallites were found to form at the interface after in vivo implantation into cortical bone.

Journal Article↗

Effect of crosslinking agents on poly(ethylmethacrylate) bone cements.

Asceptic loosening of cemented joint prostheses in many cases is related to the mechanical failure of the acrylic bone cement. Poly(methylmethacrylate) bone cements are widely used in orthopaedic surgery although there are well-known disadvantages. A lower modulus bone cement based on poly(ethylmethacrylate)-n-butylmethacrylate with a lower polymerization exotherm, and a low monomer extractibility, is a promising alternative. The effect of incorporating crosslinking agents in order to improve the mechanical performance of the PEMA bone cement is reported. Three different bifunctional dimethacrylate crosslinking agents with different chain lengths and degrees of flexibility were incorporated in the monomer phase, and cements formulated. The setting time was found to decrease in the presence of the cross-linking agents and the polymerization exotherm decreased in the presence of triethylene glycol dimethacrylate and polyethylene glycol dimethacrylate, n=400. Incorporation of triethylene glycol dimethacrylate showed an increase in the tensile strength and modulus with a decrease in the strain at maximum stress. However, polyethylene glycol dimethacrylate, n=400, did not improve the mechanical properties appreciably which may be attributed to the low crosslinking density and higher flexibility of the spacer group in the crosslinking agent.

Journal Article↗

The size and shape of particulate polyethylene wear debris in total joint replacements.

Osteolysis induced by wear particles has been recognized as one of the major causes of long-term failure in total joint replacements. However, little is currently known about the exact nature of particles, as the particles are too small to be characterized by light microscopy. In this study, ultra-high molecular weight polyethylene (UHMWPE) particles retrieved from ten cases (six cemented and four uncemented) for Freeman type conforming tibiofemoral total knee replacements (TKRs), three Charnley total hip replacements (THRs) and five Imperial College/London Hospital double cup surface hip replacements for aseptic loosening were extracted using a high-performance method with ultracentrifugation and characterized by scanning electron microscopy. The equivalent circle diameter (ECD) of all 18 cases ranged from 0.40 to 1.15 microns (Mean +/- SE = 0.70 +/- 0.05 micron, median = 0.67 micron). The aspect ratio was 1.50 to 2.04 (Mean +/- SE = 1.75 +/- 0.04, median = 1.73), and roundness was 1.24 to 2.34 (Mean +/- SE = 1.61 +/- 0.07, median = 1.65). The numbers of particles were 5.2 x 10(8) to 9.17 x 10(10)/g tissue (Mean +/- SE = 1.42 x 10(10) +/- 5.41 x 10(9)/g tissue, median = 7.04 x 10(9)). The number of polyethylene (PE) particles/g tissue in TKRs was significantly larger than that in THRs (1.04 x 10(10)/g tissue and 2.16 x 10(9)/g tissue respectively, median, p = 0.03, Mann-Whitney U test). Unstable fixation of the tibial PE component might account for the accumulation of a large number of PE particles in the interface tissue.

Biocompatible Materials↗

Number of polyethylene particles and osteolysis in total joint replacements. A quantitative study using a tissue-digestion method.

Our aim was to analyse the influence of the size, shape and number of particles on the pathogenesis of osteolysis. We obtained peri-implant tissues from 18 patients having revision surgery for aseptically loosened Freeman total knee replacements (10), Charnley total hip replacements (3) and Imperial College/London Hospital double-cup surface hip replacements (5). The size and shape of the polyethylene particles were characterised using SEM and their concentration was calculated. The results were analysed with reference to the presence of radiological osteolysis. The concentration of polyethylene particles in 6 areas with osteolysis was significantly higher than that in 12 areas without osteolysis. There were no significant differences between the size and shape of the particles in these two groups. We conclude that the most critical factor in the pathogenesis of osteolysis is the concentration of polyethylene particles accumulated in the tissue.

Chromatography, High Pressure Liquid↗

In situ analysis of the degree of polymerization of bone cement by using FT-Raman spectroscopy.

A method has been developed which enables an in situ analysis of the degree of polymerization of bone cement. The concentration of monomeric double bond is monitored continuously during the entire curing process and hence the method can be used for quantitative studies of polymerization kinetics. In this study, Fourier Transform Raman (FTR) spectroscopy was utilized to investigate the degree of polymerization of a novel bone cement in situ, and the results are compared with the thermal profile obtained for polymerization.

Biocompatible Materials↗

Structural changes of thermally sprayed hydroxyapatite investigated by Rietveld analysis.

Hydroxyapatite (HA) coatings were prepared by three thermal spraying methods: flame spraying, high velocity oxygen fuel spraying and plasma spraying. The HA was then examined by Rietveld analysis using the General Structure Analysis Software package (GSAS) and the results compared with those for the precursor powder. A comparison between HA before and after spraying showed that all three spraying methods caused a distortion in the unit cell in the form of a unit cell a-axis length decrease and a c-axis increase. Overall unit cell volumes showed a difference between the three thermal methods, with flame spraying and high velocity oxygen fuel methods giving a unit cell volume increase and the air plasma spraying method showing a decrease, compared to the starting powders. The two different starting powders used each showed a high oxygen occupancy for the hydroxyl oxygen. When thermally sprayed, both powders gave a reduction in occupancy, which suggested carbonate substitution for the OH group, but this was subsequently removed when thermally processed. The spraying also formed oxyapatite, indicated both by spectral analysis showing a reduction in the hydroxyl peak and by the hydroxyl oxygen occupancy falling to a level below 0.5. Major differences between the three spraying methods could be seen in the distortion index calculations. The thermal spraying techniques gave an increase in the distortion index, but it was significantly higher for the plasma-sprayed coating.

Biocompatible Materials↗

Carbonate hydroxyapatite gel monolith formation and drying.

The effect of carbonate in reducing the crystal size of precipitated hydroxyapatite by approximately an order of magnitude has not been used previously in the preparation of gel monoliths for the fabrication of carbonate hydroxyapatite ceramics. The aim of this study was to devise a method whereby gel monoliths of carbonate hydroxyapatite could be repeatably produced without cracking. A precipitation reaction was used for the preparation of carbonate hydroxyapatities with carbonate contents of 5.8 and 7.8 wt%. Biaxial vacuum filtration was used to form disc shaped monoliths. The rate of filtration of a 7.8 wt% carbonate hydroxyapatite sol was measured throughout the gelation process. Gel monoliths were dried slowly in air and the mass and dimensions of the gel were recorded once approximately every 24 hours. Using this data, the permeability, water volume fraction with time, rate of water loss, gelation point and gel density were determined. The pore size distribution was measured using mercury porosimetry for a carbonate apatite gel and a pressed powder pellet of a commercial hydroxyapatite. In tact monoliths were formed with masses up to 9.9 g. It was found that gelation behaviour was independent of monolith size and carbonate content and the final green density of all monoliths was 37%. Gelation was found to occur at 50-55 vol% water. Gel monoliths were found to have a monomodal pore size distribution with a mean pore size of 9.1 nm, whereas a pressed pellet of hydroxyapatite had a bimodal pore size distribution.

Apatites↗