Search PubMed⌕ Search

Biomedical subjects

Uwe Karst

Publications and source records attributed to Uwe Karst.

At least 37 records · Page 2Linked to original sources

Turbulent flow chromatography for the reduction of matrix effects in electrospray ionization mass spectrometry-based enzyme assays.

Turbulent flow chromatography (TFC) is presented as a means to reduce ion suppression in simultaneous multianalyte mass spectrometric bioassays. In this study, the effects of enzymes present in the sample on the signal response of five analytes were simultaneously investigated over a protein content range from 0 to 38 microg/mL by means of direct flow injection MS. As model enzymes, trypsin, thrombin, and chymotrypsin were selected. Without employment of TFC, both signal suppression and signal enhancement, depending on the nature of the analyte and the amount of matrix in the sample, were observed. Generally, these matrix effects were found to be intolerably large. The deviation from the mean signal response as a measure of deterioration was found to be between 14 and 112%. The addition of an excess of methanol as means of sample clean-up was investigated and found not to be sufficient. By employing TFC for online sample preparation, it was possible to reduce the matrix effecTs to a minimum for all model systems investigated. In case of trypsin the distortion could be lowered from 41.9 to 2.6%. Thus, TFC is considered to be a highly valuable tool for improving the sensitivity and reliability in the monitoring of enzymatic conversions by means of MS.

Chromatography, Liquid↗

Screening for proteolytic activities in snake venom by means of a multiplexing electrospray ionization mass spectrometry assay scheme.

A multiplexed mass spectrometry based assay scheme for the simultaneous determination of five different substrate/product pairs was developed as a tool for screening of proteolytic activities in snake venom fractions from Bothrops moojeni. The assay scheme was employed in the functional characterization of eight model proteases. Time-resolved reaction profiles were generated and the relative reaction progress at each time point was determined. These were used to semi-quantitatively sort the catalytic activities of each enzyme towards the respective substrates into six classes. The resulting activity pattern served as an activity fingerprint for each enzyme. The multiplex assay scheme was then applied to a screening for proteolytic activities in fractions of the pre-separated venom from B. moojeni. Activity patterns of each fraction were generated and used to sort the fractions into three different categories of activity. By comparison of the fingerprint activity patterns of the venom fractions and the model enzymes, a compound with proteolytic properties similar to activated protein C was detected.

Animals↗

Determination of aldehydes and ketones using derivatization with 2,4-dinitrophenylhydrazine and liquid chromatography-atmospheric pressure photoionization-mass spectrometry.

Atmospheric pressure photoionization-mass spectrometry (APPI-MS) is used for the analysis of aldehydes and ketones after derivatization with 2,4-dinitrophenylhydrazine (DNPH) and liquid chromatographic separation. In the negative ion mode, the [M - H]- pseudomolecular ions are most abundant for the carbonyls. Compared with the established atmospheric pressure chemical ionization (APCI)-MS, limits of detection are typically lower using similar conditions. Automobile exhaust and cigarette exhaust samples were analyzed with APPI-MS and APCI-MS in combination with an ion trap mass analyzer. Due to improved limits of detection, more of the less abundant long-chain carbonyls are detected with APPI-MS in real samples. While 2,4-dinitrophenylazide, a known reaction product of DNPH with nitrogen dioxide, is detected in APCI-MS due to dissociative electron capture, it is not observed at all in APPI-MS.

Aldehydes↗

Detection strategies for bioassays based on luminescent lanthanide complexes and signal amplification.

Two attractive detection strategies for bioassays are reviewed in this article. Both approaches use the highly sensitive time-resolved luminescence detection of lanthanide complexes in combination with a signal amplification scheme. While enzyme-amplified lanthanide luminescence (EALL) has been an established technique for more than a decade, nanoparticles doped with luminescent lanthanide complexes have been introduced very recently. In this paper, the basic properties and major applications of both techniques are presented, and their future perspectives are discussed critically.

Biosensing Techniques↗

Liquid chromatographic-mass spectrometric studies on the in vitro degradation of a poly(ether ester) block copolymer.

A detailed study on the in vitro degradation of a poly(ethylene glycol) and poly(butylene terephthalate) (PEOT/PBT) segmented block copolymer was carried out using liquid chromatography/electrospray-mass spectrometry. Accelerated hydrolysis of PEOT/PBT was achieved by placing the material for 14 days in a refluxing phosphate buffered saline (pH 7.4) solution. All major degradation products and several side-products were identified using both the positive and the negative ion mode. The data indicate that degradation does not only occur in the "soft", but also in the "hard" segments of the polymer. Liquid chromatographic separation is required to distinguish between degradation products with different sequences but identical molecular mass. The addition of ammonium and sodium ions provided important complementary information on the number of monomer units present in the degradation products.

Chromatography, Liquid↗

Liquid chromatography/coordination ion spray-mass spectrometry for the analysis of rubber vulcanization products.

Liquid chromatography/coordination ion spray-mass spectrometry has been used for the identification of reaction products in a model rubber vulcanization process. After LC separation using reversed-phase conditions, AgBF(4) in acetonitrile was added, and strong signals were observed for silica-rubber coupling agents and products of the reaction between these and alkenes. The method performs best for substances containing sulfur chains with chain lengths between two and eight sulfur atoms, but sulfur-free compounds containing triethoxysilyl groups were detected as well. For the latter, the postcolumn addition of NaBF(4) proved to be a suitable alternative. Besides the coupling agents, various reaction products, including sulfur-chain bridged alkenes were identified.

Journal Article↗

Ferrocenoyl piperazide as derivatizing agent for the analysis of isocyanates and related compounds using liquid chromatography/electrochemistry/mass spectrometry (LC/EC/MS).

Ferrocenoyl piperazide is introduced as a new pre-column derivatizing agent for the analysis of various isocyanates in air samples using reversed-phase liquid chromatographic separation, electrochemical oxidation/ionization, and mass spectrometry. The nonpolar derivatives can be separated well using a phenyl-modified stationary phase and a formic acid/ammonium formate buffer of pH 3, which yields excellent separations, especially for one problematic group of isocyanates consisting of 2,4- and 2,6-toluylenediisocyanate (2,4- and 2,6-TDI) and hexamethylenediisocyanate (HDI). Electrochemical oxidation at low potentials (0.5 V versus Pd/H(2)) leads to formation of charged products, which are nebulized in a commercial atmospheric pressure chemical ionization (APCI) source, with the corona discharge operated only at low voltage. Limits of detection between 6 and 20 nmol/L are obtained for the isocyanate derivatives, and calibration is linear over at least two decades of concentration. The method is applied for the analysis of air after thermal degradation of a polyurethane foam, and it is demonstrated that it is suitable as well for the analysis of carboxylic acid chlorides and of isothiocyanates.

Chromatography, High Pressure Liquid↗

Reaction monitoring of enzyme-catalyzed ester cleavage by time-resolved fluorescence and electrospray mass spectrometry: method development and comparison.

Two complementary methods for reaction monitoring of the esterase-catalyzed cleavage of bis(2-pyridylmethyl)(2-acetoxyphenyl)amine are developed and compared. While enzyme-amplified lanthanide luminescence (EALL) allows for the time-resolved fluorescence determination of the intrinsically non-fluorescent product, both substrate and product of the enzymatic reaction may be determined simultaneously by electrospray mass spectrometry (ESI-MS). Excitation wavelength for the Tb(III) complex of the reaction product is 297 nm and emission was detected at 545 nm, which is the characteristic emission wavelength of the terbium(III) ion. In contrast to other EALL techniques, the presented method allows for the direct monitoring of an enzymatic conversion without any further sample preparation (e.g., rebuffering). For the mass spectrometric measurements the mass traces were set to m/z=306, 328, 348, and 370 for the protonated ester, the resulting phenol and their sodium adducts, respectively.

Catalysis↗

Analysis of phenothiazine and its derivatives using LC/electrochemistry/MS and LC/electrochemistry/fluorescence.

The on-line electrochemical conversion of phenothiazine and its derivatives after liquid chromatographic separation has been studied by mass spectrometry and fluorescence spectroscopy. In an electrochemical cell consisting of porous glassy carbon, the phenothiazines are readily converted to oxidized products, which can be detected by on-line fluorescence spectroscopy and mass spectrometry. The method allows rapid investigations on the electrochemical oxidation pathways, as demonstrated for phenothiazine itself. The phenothiazine derivatives are transferred into their strongly fluorescent sulfoxides. Based on this reaction, an LC/electrochemistry/fluorescence method was developed that allows for limits of detection between 5 x 10(-9) and 4 x 10(-8) mol/L and limits of quantification between 2 x 10(-8) and 1 x 10(-7) mol/L for the individual phenothiazines. The linear ranges comprised three decades starting at the limit of quantification.

Chromatography, Liquid↗

Liquid chromatography-electrochemistry-mass spectrometry of polycyclic aromatic hydrocarbons.

An efficient method for fast elucidation of the electrochemical reactions of polycyclic aromatic hydrocarbons (PAH) has been set up by applying post-column electrochemistry in liquid chromatography-mass spectrometry (LC-MS). With this set-up strong improvement of sensitivity in the LC-MS analysis of PAH is observed. Due to their low redox potentials, the non-polar PAH are converted into the respective radical cations, which may further react with constituents of the mobile phase and in additional electrochemical oxidation steps. Among other products, mono-, di-, and trioxygenated species are observed in aqueous solutions, alkoxylated compounds in alcohols, and solvent adducts in the presence of acetonitrile. While more different products are observed by using atmospheric pressure chemical ionization in the positive-ion mode (APCI(+)), the deprotonation of hydroxylated species results in very clear spectra in the negative-ion mode (APCI(-)). Deuterated PAH and deuterated solvents were used to gain additional information on the formation of the reaction products.

Journal Article↗

Strategies for the liquid chromatographic-mass spectrometric analysis of non-polar compounds.

Electrospray ionization and atmospheric pressure chemical ionization (APCI) have evolved recently as very useful tools for the liquid chromatographic-mass spectrometric (LC-MS) analysis of polar substances. Non-polar compounds, however, are difficult to analyze with these atmospheric pressure ionization techniques due to their soft ionization mechanism. Recently, new approaches have been introduced which are likely to overcome this obstacle, at least partly. On-line electrochemical conversion of the analytes to more polar reaction products, atmospheric pressure photoionization, atmospheric pressure electron capture negativeion-MS and coordination ionspray-MS are four techniques which are presented in detail compared and discussed critically with respect to their current status and future perspectives. Particular focus is directed from a chemical viewpoint on the substance groups which are accessible by each of the new approaches.

Atmospheric Pressure↗

Trace analysis of peroxide-based explosives.

The first method for quantitative trace analysis of peroxide-based explosives is described. A reversed-phase high-performance liquid chromatography method with post-column UV irradiation and fluorescence detection for the analysis of triacetone triperoxide (TATP) and hexamethylene triperoxide diamine (HMTD) has been developed. After separation, the analytes are degraded photochemically to hydrogen peroxide, which is subsequently determined on the basis of the peroxidase-catalyzed oxidation of p-hydroxyphenylacetic acid to the fluorescent dimer. This two-step reaction scheme in combination with the respective blanks (photochemical reactor switched off) provides for high selectivity. The limits of detection were 2 x 10(-6) mol/L for both TATP and HMTD, respectively. The method has been applied to the analysis of real samples.

Bridged Bicyclo Compounds, Heterocyclic↗

Liquid chromatography with on-line electrochemical derivatization and fluorescence detection for the determination of phenols.

A new methodological approach for the determination of monosubstituted phenols is described. After liquid chromatographic separation of the analytes, an on-line electrochemical derivatization is carried out and the reaction products are detected fluorometrically. Phenols are oxidized in the electrochemical cell to form fluorescent dimers and higher oligomers, which were identified by on-line electrochemistry/mass spectrometry. Major advantages of the proposed method include enhanced selectivity and sensitivity. Without prior enrichment of the analytes, limits of detection down to 2 x 10(-9) M (20 fmol) may be reached for selected phenols, e.g., for 4-octylphenol, 4-ethylphenol, and 4-(1-indanyl)phenol. Only readily available instrumentation is required for these measurements.

Journal Article↗

Diffusive sampling of methyl isocyanate using 4-nitro-7-piperazinobenzo-2-oxa-1,3-diazole (NBDPZ) as derivatizing agent.

A diffusive sampling method for the determination of methyl isocyanate (MIC) in air is introduced. MIC is collected using a glass fiber filter impregnated with 4-nitro-7-piperazinobenzo-2-oxa-1,3-diazole (NBDPZ). The urea derivative formed is desorbed from the filter with acetonitrile and analyzed by means of high-performance liquid chromatography (HPLC) using fluorescence detection (FLD) with lambdaex = 471 nm and lambdaex = 540 nm. Additionally, a method was developed using tandem mass spectrometric (MS-MS) detection, which was performed as selected reaction monitoring (SRM) on the transition [MIC-NBDPZ + H]+ (m/z 307) to [NBDPZ + H]+ (m/z 250). The diffusive sampler was tested with MIC concentrations between 1 and 35 microg m(-3). The sampling periods varied from 15 min to 8 h, and the relative humidity (RH) was set from 20% up to 80%. The sampling rate for all 15 min experiments was determined to be 15.0 mL min(-1) (using HPLC-FLD) with a relative standard deviation of 9.9% for 56 experiments. At 80% RH, only 15 min sampling gave acceptable results. Further experiments revealed that humidity did not affect the MIC derivative but the reagent on the filter prior to and during sampling. The sampling rate for all experiments (including long term sampling) performed at 20% RH was found to be 15.0 mL min(-1) with a relative standard deviation of 6.3% (N = 42). The limit of quantification was 3 microg m(-3) (LC-MS-MS: 1.3 microg m(-3)) for 15 min sampling periods and 0.2 microg m(-3) (LC-MS-MS: 0.15 microg m(-3)) for 8 h sampling runs applying fluorescence detection.

Absorption↗

A tripod ligand as new sensitiser for the enzyme amplified lanthanide luminescence determination of esterase.

Screening of a small library of tripod ligands resulted in the discovery of bis(2-pyridylmethyl)-(2-hydroxybenzyl)amine (HL1) as a new sensitiser, which is able to transfer its excitation energy to terbium(III). After synthesis of the acetic acid ester of HL1, a highly selective method for the determination of porcine liver esterase by means of enzyme amplified lanthanide luminescence (EALL) was developed. Enzyme-catalysed cleavage of the ester results in the formation of HL1. After excitation at 297 nm, the characteristic emission of Tb(III) at 545 nm is observed and used to determine the esterase concentration. In contrast to existing EALL methods, this method may be carried out at neutral pH and without further additives. Limit of detection for porcine liver esterase is 10(-9) mol l(-1) and limit of quantification is 3 x 10(-9) mol l(-1). A linear calibration range of two decades starting at the limit of quantification is observed.

Animals↗