Determination of peroxide-based explosives using liquid chromatography with on-line infrared detection.

A nondestructive analytical method for peroxide-based explosives determination in solid samples is described. Reversed-phase high-performance liquid chromatography in combination with on-line Fourier transform infrared (FT-IR) detection is used for the analysis of triacetonetriperoxide (TATP) and hexamethylenetriperoxide diamine (HMTD). In contrast to other liquid chromatographic methods with optical detection, no derivatization or decomposition of the peroxides is required. The peroxides are identified and quantified via their characteristic absorption spectra in the mid-infrared range of the electromagnetic spectrum. The detection limit of 0.5 mmol L-1 for HMTD and 1 mmol L-1 for TATP allows the identification of the explosives in complex matrixes.

Journal Article↗

Determination of airborne isocyanates.

Isocyanates are important in industrial hygiene and workplace monitoring. Owing to their severe acute toxicity and sensitizing properties, analytical methods with high sampling efficiency and sensitivity in the low ppb to ppt range are required. The reactivity of isocyanates necessitates initial derivatization with nucleophilic agents--usually amines--for stabilization and enrichment; this is often followed by chromatographic separation with spectroscopic, electrochemical, or mass spectrometric detection. Sampling strategies for airborne isocyanates comprise active, i.e. pumped, or passive, i.e. diffusive, methods; the method selected depends on the application. Whereas active methods rely mainly on impingers, reagent-coated filters, or sampling tubes, passive samplers make use of reagent-coated filters, the surface of which is connected to the air sample by diffusion channels. Because airborne isocyanates are prone to occur in different forms, i.e. as vapors, as aerosols, or adsorbed on particulate matter, denuder sampling has been introduced, thus enabling simultaneous collection of gaseous and aerosol isocyanates. The first part of this review summarizes chemical methods and reagents which have been introduced for derivatization of airborne isocyanates. The advantages and drawbacks of the individual derivatization procedures and their combination with different detection principles are evaluated. In the second part, the most recent developments in air sampling for isocyanates, with special focus on diffusive sampling, are reviewed and critically discussed.

Journal Article↗

Simulation of the detoxification of paracetamol using on-line electrochemistry/liquid chromatography/mass spectrometry.

On-line electrochemistry/liquid chromatography/mass spectrometry was used to simulate the detoxification mechanism of paracetamol in the body. In an electrochemical flow-through cell, paracetamol was oxidized at a porous glassy carbon working electrode at a potential of 600 mV vs. Pd/H2 with formation of a quinoneimine intermediate. The quinoneimine further reacted with glutathione and/or N-acetylcysteine to form isomeric adducts via the thiol function. The adducts were characterized on-line by liquid chromatography/mass spectrometry. These reactions are similar to those occurring between paracetamol and glutathione under catalysis by cytochrome P450 enzymes in the body.

Acetaminophen↗

Recent developments in optical detection methods for microchip separations.

This paper summarizes the features and performances of optical detection systems currently applied in order to monitor separations on microchip devices. Fluorescence detection, which delivers very high sensitivity and selectivity, is still the most widely applied method of detection. Instruments utilizing laser-induced fluorescence (LIF) and lamp-based fluorescence along with recent applications of light-emitting diodes (LED) as excitation sources are also covered in this paper. Since chemiluminescence detection can be achieved using extremely simple devices which no longer require light sources and optical components for focusing and collimation, interesting approaches based on this technique are presented, too. Although UV/vis absorbance is a detection method that is commonly used in standard desktop electrophoresis and liquid chromatography instruments, it has not yet reached the same level of popularity for microchip applications. Current applications of UV/vis absorbance detection to microchip separations and innovative approaches that increase sensitivity are described. This article, which contains 85 references, focuses on developments and applications published within the last three years, points out exciting new approaches, and provides future perspectives on this field.

Journal Article↗

Quantitative on-chip determination of taurine in energy and sports drinks.

A new method for the quantitative determination of taurine in beverages by microchip electrophoresis was developed. A rapid and simple sample preparation procedure, only including two dilution steps and the addition of the fluorogenic labeling reagent NBD-Cl (4-chloro-7-nitrobenzofurazan), is applied. Using a home-built wavelength-resolved fluorescence detector, the separation and determination of the taurine derivative could be achieved in only 12 s, while the additional spectral information was utilized to ensure peak purity. Spanning from 0.1 to 50 mmol L(-1), the linear dynamic range of the applied method was adapted to the apparent contents in common taurine containing beverages. The smallest detectable amount of the taurine derivative actually injected into the separation channel was as low as 60 amol. The method was successfully validated by an independent liquid chromatographic method.

Journal Article↗

Validation of a diffusive sampling method for airborne low-molecular isocyanates using 4-nitro-7-piperazinobenzo-2-oxa-1,3-diazole-impregnated filters and liquid chromatography-tandem mass spectrometry.

A diffusive sampling method for the determination of low-molecular isocyanates as their 4-nitro-7-piperazinobenzo-2-oxa-1,3-diazole (NBDPZ) derivatives using tandem mass spectrometry (MS/MS) after atmospheric pressure chemical ionisation (APCI) is presented. Isocyanic acid (ICA), methyl isocyanate (MIC), ethyl isocyanate (EIC) and phenyl isocyanate (PhIC) are collected on NBDPZ-impregnated polystyrene divinyl benzene (SDB) filter tapes. The method was validated for MIC, EIC and PhIC for concentrations between 0.5 and 50 ppb at relative humidity (RH) conditions from 10 up to 90%. Validation was carried out by active sampling using 1-(2-methoxyphenyl)piperazine (2-MP) as derivatising agent. Sampling periods applied were between 15 min and more than 8 h. The sampling rates were determined to be 21.0 mL/min for MIC with a relative standard deviation (RSD) of 9.0% for 184 samplers, 15.6 mL/min for EIC (RSD 11.6%; N = 154) and 11.5 mL/min for PhIC (RSD 8.4%; N = 87). The limits of quantification were 1.4 ppb for MIC and 1.3 ppb for EIC and PhIC applying 15 min sampling periods. Owing to high background signals, isocyanic acid could only be determined when it was present in concentrations in the high ppb range.

Air↗

Passive sampling of airborne peroxyacetic acid.

The first passive sampling device for the determination of airborne peroxyacetic acid (PAA) is presented. 2-([3-{2-[4-Amino-2-(methylsulfanyl)phenyl]-1-diazenyl}phenyl]sulfonyl)-1-ethanol (ADS) is used to impregnate glass fiber filters, and the reagent is oxidized by PAA to the corresponding sulfoxide ADSO. After elution of the filters, ADS and ADSO are separated by reversed-phase HPLC and detected by UV/visible absorbance. Limit of detection is 30 ppb, limit of quantification is 90 ppb (for 30 min sampling), and the linear range comprises 2 orders of magnitude. Thorough investigations were carried out with respect to the selectivity of the method toward hydrogen peroxide, and air samples were analyzed successfully after disinfection of a laboratory area.

Air Pollutants, Occupational↗

Recent methods for the determination of peroxide-based explosives.

In the last few years, the need to determine peroxide-based explosives in solid samples and air samples has resulted in the development of a series of new analytical methods for triacetonetriperoxide (TATP, acetone peroxide) and hexamethylenetriperoxidediamine (HMTD). In this review, after a short introduction describing the state of the art in the field, these new analytical methods are critically discussed. Particular emphasis is placed on spectroscopic and mass spectrometric methods as well as on chromatographic techniques with selective detection schemes. The potential of these methods to analyse unknown solid samples that might contain one or more of the explosives and to analyse peroxide-based explosives in air is evaluated.

Journal Article↗

From fundamentals to applications: recent developments in atmospheric pressure photoionization mass spectrometry.

Only five years after the first publication on atmospheric pressure photoionization (APPI), this technique has evolved rapidly as a very useful complement to established ionization techniques for liquid chromatography/mass spectrometry (LC/MS). This is reflected in a rapidly increasing number of publications in this field. On the one hand, thorough studies into the photoionization mechanism have provided deep insights into the roles and influences of the solvent, the dopant and other additives. On the other hand, a large number of new and attractive applications have recently been introduced. New instrumental developments have resulted in combined APPI/ESI (PAESI) and APPI/APCI sources and a microfabricated APPI source. In this review, the most important developments within the field are summarized, focusing in particular on the applications of the technique.

Journal Article↗

Chip-based on-line nanospray MS method enabling study of the kinetics of isocyanate derivatization reactions.

The reaction of propyl isocyanate (2), benzyl isocyanate (3), and toluene-2,4-diisocyanate (4) with 4-nitro-7-piperazino-2,1,3-benzoxadiazole (1) to yield the corresponding urea derivatives 5 was carried out in a continuous flow glass microfluidics chip. Real-time monitoring of the derivatization reactions was done by electrospray ionization mass spectrometry, making use of a recently reported modular chip-MS interface. Rate constants of 1.5 x 10(4), 5.2 x 10(4), and 2.4 x 10(4) M(-1) min(-1) were determined for 2, 3, and 4, respectively. Using macroscale batch conditions, the rate constants are 3-4 times lower. The faster on-chip kinetics is attributed to the more efficient molecular diffusion in the micrometer-sized channel.

Journal Article↗

Analysis of microperoxidases using liquid chromatography, post-column substrate conversion and fluorescence detection.

A liquid chromatographic method with on-line activity determination for microperoxidases has been developed. After enzymatic digestion of a cytochrome, possibly under formation of microperoxidases, the product mixture is separated by reversed-phase liquid chromatography. The products first pass a diode-array detector, and are then subjected to a reaction with 4-(N-methylhydrazino)-7-nitro-2,1,3-benzooxadiazole (MNBDH) and hydrogen peroxide. In a reaction coil, microperoxidases catalyze the reaction under formation of the fluorescent 4-(N-methylamino)-7-nitro-2,1,3-benzooxadiazole (MNBDA). Quantification of the microperoxidases is performed using a fluorescence detector at an excitation wavelength of 470 nm and an emission wavelength of 545 nm, respectively. For this LC-based detection system, limits of detection are 3 x 10(-8) mol/L, limits of quantification are 9 x 10(-8) mol/L, and a linear range from 9 x 10(-8) mol/L to 3 x 10(-6) mol/L is obtained for the microperoxidases MP-9 and MP-11. A highly active microperoxidase MP-6 was found in the reaction of cytochrome c from bovine heart with protease from streptomyces griseus.

Animals↗

Labeling strategies for bioassays.

Different labeling strategies for enzymatic assays and immunoassays are reviewed. Techniques which make use of direct detection of a label, e.g. radioimmunoassays, are discussed, as are techniques in which the label is associated with inherent signal amplification. Examples of the latter, e.g. enzyme-linked immunosorbent assays or nanoparticle-label based assays, are presented. Coupling of the bioassays to chromatographic separations adds selectivity but renders the assays more difficult to apply. The advantages and drawbacks of the different analytical principles, including future perspectives, are discussed and compared. Selected applications from clinical, pharmaceutical, and environmental analysis are provided as examples.

Fluorescent Dyes↗

Monitoring enzymatic conversions by mass spectrometry: a critical review.

This review highlights recent advances in the application of electrospray ionisation and matrix-assisted laser desorption/ionisation mass spectrometry (MS) to study enzymatic reactions. Several assay schemes for different fields of application are presented. The employment of MS as a means of detection in pre-steady-state kinetic studies by rapid-mixing direct analysis and rapid-mixing quench flow techniques is discussed. Several steady-state kinetic studies of a broad range of different enzymatic systems are presented as well as enzyme inhibition studies for various target enzymes. As a promising new development multiplex assays, which monitor the conversion of several substrates simultaneously in one experiment, are described. This assay type has been used for competition studies, enzymatic activity screenings and for diagnostic purposes in clinical chemistry. Generally, it can be concluded that mass spectrometry offers an intriguing alternative as detection methodology in enzymatic bioassays. Its applicability for the monitoring the conversion of naturally occurring substrates and its overall versatility make MS an especially promising tool for the study of enzyme-catalysed processes.

Enzymes↗

Prediction of clozapine metabolism by on-line electrochemistry/liquid chromatography/mass spectrometry.

Combining electrochemical conversion, liquid chromatography and electrospray ionization mass spectrometry (EC/LC/ESI-MS) on-line allows the rapid identification of possible oxidation products of clozapine (CLZ) in the absence and in the presence of glutathione. CLZ is, depending on the applied potential, oxidized to various products in an electrochemical flow-through cell using a porous glassy carbon working electrode. Several hydroxylated and demethylated species are detected on-line using LC/MS. While hydroxy-CLZ is most abundant at a potential of 400 mV, demethylation occurs more readily at higher potentials (at around 700 mV versus Pd/H(2) reference). In the presence of glutathione (GSH), various isomeric glutathione adducts and respective products of further oxidation can be identified. The thioadducts are characterized by tandem MS. Mono-GSH and bis-GSH derivatives can be seen in the chromatograms. The results correlate well with the cyclic voltammetric profile of CLZ. The data are relevant from a pharmacological point of view, since similar metabolites (phases I and II) have been reported in the literature. The EC/LC/MS and EC/MS methods should be valuable tools that can be used to anticipate and understand the metabolization patterns of molecules of pharmacological interest and to point out reactive intermediates.

Chromatography, Liquid↗

Liquid chromatographic/mass spectrometric investigation on the reaction products in the peroxidase-catalyzed oxidation of o-phenylenediamine by hydrogen peroxide.

Mass spectrometric evidence was obtained to confirm that the main reaction product of the horseradish peroxidase (POD)-catalyzed oxidation of o-phenylenediamine (OPD) by hydrogen peroxide is 2,3-diaminophenazine. Although this reaction is one of the most widespread detection schemes in enzyme-linked immunosorbent assays (ELISAs), the literature data on the identity of the reaction product(s) have been strongly contradictory throughout the last few decades. Liquid chromatography with UV/Vis and mass spectrometric detection as well as exact mass measurements after LC fraction collection have led to the unambiguous identification of 2,3-diaminophenazine as main reaction product. 2,2'-Diaminoazobenzene, which is frequently described in other publications to be the major reaction product, was not detected at all.

Catalysis↗

Assessing protease activity pattern by means of multiple substrate ESI-MS assays.

The development of a simultaneous multiple substrate enzymatic assay based on electrospray ionization mass spectrometry (ESI-MS) detection is described. This multiplexing assay scheme was employed in a parallel proteolytic enzyme activity screening. As model systems, the respective activities of trypsin, thrombin, chymotrypsin, bromelain, ficin and elastase towards seven different substrates were assessed. The resulting activity patterns were evaluated semi-quantitatively ranking the enzymatic activities in five classes of activity (very high, high, medium, low and no activity) with respect to the individual substrates. The validity of the MS-based multiplexing assay scheme was proved by comparison with the results obtained from single substrate assays detected by means of UV/vis absorption at 405 nm, showing good agreement of the resulting activity patterns and classifications.

Flow Injection Analysis↗

Bilayer vesicles of amphiphilic cyclodextrins: host membranes that recognize guest molecules.

A family of amphiphilic cyclodextrins (6, 7) has been prepared through 6-S-alkylation (alkyl=n-dodecyl and n-hexadecyl) of the primary side and 2-O-PEGylation of the secondary side of alpha-, beta-, and gamma-cyclodextrins (PEG=poly(ethylene glycol)). These cyclodextrins form nonionic bilayer vesicles in aqueous solution. The bilayer vesicles were characterized by transmission electron microscopy, dynamic light scattering, dye encapsulation, and capillary electrophoresis. The molecular packing of the amphiphilic cyclodextrins was investigated by using small-angle X-ray diffraction of bilayers deposited on glass and pressure-area isotherms obtained from Langmuir monolayers on the air-water interface. The bilayer thickness is dependent on the chain length, whereas the average molecular surface area scales with the cyclodextrin ring size. The alkyl chains of the cyclodextrins in the bilayer are deeply interdigitated. Molecular recognition of a hydrophobic anion (adamantane carboxylate) by the cyclodextrin vesicles was investigated by using capillary electrophoresis, thereby exploiting the increase in electrophoretic mobility that occurs when the hydrophobic anions bind to the nonionic cyclodextrin vesicles. It was found that in spite of the presence of oligo(ethylene glycol) substituents, the beta-cyclodextrin vesicles retain their characteristic affinity for adamantane carboxylate (association constant K(a)=7.1 x 10(3) M(-1)), whereas gamma-cyclodextrin vesicles have less affinity (K(a)=3.2 x 10(3) M(-1)), and alpha-cyclodextrin or non-cyclodextrin, nonionic vesicles have very little affinity (K(a) approximately 100 M(-1)). Specific binding of the adamantane carboxylate to beta-cyclodextrin vesicles was also evident in competition experiments with beta-cyclodextrin in solution. Hence, the cyclodextrin vesicles can function as host bilayer membranes that recognize small guest molecules by specific noncovalent interaction.

Air↗