Tissue stresses and strain in trabeculae of a canine proximal femur can be quantified from computer reconstructions.

A quantitative assessment of bone tissue stresses and strains is essential for the understanding of failure mechanisms associated with osteoporosis, osteoarthritis, loosening of implants and cell-mediated adaptive bone-remodeling processes. According to Wolff's trajectorial hypothesis, the trabecular architecture is such that minimal tissue stresses are paired with minimal weight. This paradigm at least suggests that, normally, stresses and strains should be distributed rather evenly over the trabecular architecture. Although bone stresses at the apparent level were determined with finite element analysis (FEA), by assuming it to be continuous, there is no data available on trabecular tissue stresses or strains of bones in situ under physiological loading conditions. The objectives of this project were to supply reasonable estimates of these quantities for the canine femur, to compare trabecular-tissue to apparent stresses, and to test Wolff's hypothesis in a quantitative sense. For that purpose, the newly developed method of large-scale micro-FEA was applied in conjunction with micro-CT structural measurements. A three-dimensional high-resolution computer reconstruction of a proximal canine femur was made using a micro-CT scanner. This was converted to a large-scale FE-model with 7.6 million elements, adequately refined to represent individual trabeculae. Using a special-purpose FE-solver, analyses were conducted for three different orthogonal hip-joint loading cases, one of which represented the stance-phase of walking. By superimposing the results, the tissue stress and strain distributions could also be calculated for other force directions. Further analyses of results were concentrated on a trabecular volume of interest (VOI) located in the center of the head. For the stance phase of walking an average tissue principal strain in the VOI of 279 strain was found, with a standard deviation of 212 microstrain. The standard deviation depended not only on the hip-force magnitude, but also on its direction. In more than 95% of the tissue volume the principal stresses and strains were in a range from zero to three times the averages, for all hip-force directions. This indicates that no single load creates even stress or strain distributions in the trabecular architecture. Nevertheless, excessive values occurred at few locations only, and the maximum tissue stress was approximately half the value reported for the tissue fatigue strength. These results thus indicate that trabecular bone tissue has a safety factor of approximately two for hip-joint loads that occur during normal activities.

Animals↗

Tissue stresses and strain in trabeculae of a canine proximal femur can be quantified from computer reconstructions.

A quantitative assessment of bone tissue stresses and strains is essential for the understanding of failure mechanisms associated with osteoporosis, osteoarthritis, loosening of implants and cell- mediated adaptive bone-remodeling processes. According to Wolff's trajectorial hypothesis, the trabecular architecture is such that minimal tissue stresses are paired with minimal weight. This paradigm at least suggests that, normally, stresses and strains should be distributed rather evenly over the trabecular architecture. Although bone stresses at the apparent level were determined with finite element analysis (FEA), by assuming it to be continuous, there is no data available on trabecular tissue stresses or strains of bones in situ under physiological loading conditions. The objectives of this project were to supply reasonable estimates of these quantities for the canine femur, to compare trabecular-tissue to apparent stresses, and to test Wolff's hypothesis in a quantitative sense. For that purpose, the newly developed method of large-scale micro-FEA was applied in conjunction with micro-CT structural measurements. A three-dimensional high-resolution computer reconstruction of a proximal canine femur was made using a micro-CT scanner. This was converted to a large-scale FE-model with 7.6 million elements, adequately refined to represent individual trabeculae. Using a special-purpose FE-solver, analyses were conducted for three different orthogonal hip-joint loading cases, one of which represented the stance-phase of walking. By superimposing the results, the tissue stress and strain distributions could also be calculated for other force directions. Further analyses of results were concentrated on a trabecular volume of interest (VOI) located in the center of the head. For the stance phase of walking an average tissue principal strain in the VOI of 279 strain was found, with a standard deviation of 212 microstrain. The standard deviation depended not only on the hip-force magnitude, but also on its direction. In more than 95% of the tissue volume the principal stresses and strains were in a range from zero to three times the averages, for all hip-force directions. This indicates that no single load creates even stress or strain distributions in the trabecular architecture. Nevertheless, excessive values occurred at few locations only, and the maximum tissue stress was approximately half the value reported for the tissue fatigue strength. These results thus indicate that trabecular bone tissue has a safety factor of approximately two for hip-joint loads that occur during normal activities.

Animals↗

Load transfer analysis of the distal radius from in-vivo high-resolution CT-imaging.

Prevention of osteoporotic bone fractures requires accurate diagnostic methods to detect the increase in bone fragility at an early stage of osteoporosis. However, today's bone fracture risk prediction, primarily based on bone density measurement, is not sufficiently precise. There is increasing evidence that, in addition to bone density, also the bone microarchitecture and its mechanical loading conditions are important factors determining the fracture risk. Recently, it has been shown that new high-resolution imaging techniques in combination with new computer modeling techniques based on the finite-element (FE) method can account for these additional factors. These techniques might provide information that is more relevant for the prediction of bone fracture risk. So far, however, these new imaged-based FE techniques have not been feasible in-vivo. The objectives of this study were to quantify the load transfer through the trabecular network in a distal radius using a computer model based on in-vivo high-resolution images and to determine if common regions of fractures can be explained as a result of high tissue loading in these regions. The left distal radius and the two adjacent carpal bones of a healthy volunteer were imaged using a high-resolution three-dimensional CT system providing an isotropic resolution of 165 microm. The bone representation was converted into a FE-model that was used to calculate stresses and strains in the trabecular network. The two carpal bones were loaded using different load ratios (for each load case 1000 N in total) representing impact forces on the hand either in near-neutral position or ulnar/radial deviation. The load transfer through the trabecular network of the radius was characterized by the tissue strain energy density (SED) distribution for all load cases. It was found that the distribution of the tissue loading depends on the ratio of the forces acting on the carpal bones. For all load cases the higher SED values (on average: 0.02 +/- 0.08 (S.D.) N mm(-2)) are found in a 10 mm region adjacent to the articular surface which corresponds well with the region where Colles- or Chauffeur-fractures occur. We expect that, eventually, this new approach can lead to a better prediction of the fracture risk than methods based on bone density alone since it accounts for the bone microstructure as well as its loading conditions.

Carpal Bones↗

Calibration of trabecular bone structure measurements of in vivo three-dimensional peripheral quantitative computed tomography with 28-microm-resolution microcomputed tomography.

It has recently been shown that high-resolution computed tomography and magnetic resonance imaging have the potential to assess information about the microarchitecture of bone in a noninvasive way. However, due to the limited spatial resolution of the in vivo measurements, the individual trabeculae are not depicted with their true thickness. Nevertheless, the spacing of the structural elements allows the assessment of trabecular number. In a previous publication, the ridge number density (RND) was introduced as a measure for this structural index. It can be extracted from high-resolution three-dimensional (3D) images of patients and shows a reproducibility of 1.6%. In this work the Ridge extraction procedure is compared to and calibrated with microcomputed tomography (microCT) measurements. Three-dimensional measurements of 15 bone biopsies are made with a 28-microm-resolution microCT scanner as well as with a 165-microm-resolution peripheral quantitative computed tomography (pQCT) scanner. For the latter, the same settings are used as for patient examinations. The 15 pairs of measurements are analyzed and the resulting structural indices are compared. The results show that structural indices such as trabecular number, mean thickness, and mean separation can be determined from the 3D pQCT data with an r2 of between 0.81 and 0.96 if the microCT data are taken as the gold standard. The calibration equation found for the bone volume fraction has an intercept of 0.04 and a slope of 0.86 (r2 = 0.98), and trabecular number as the main additional structural index shows a nonsignificant intercept and a calibration slope of 0.91 with the microCT. The calibration procedure can be used directly for patient examinations. Applied to time-series measurements it may be of value for monitoring and quantifying microarchitectural changes due to therapy or aging.

Adult↗

The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone.

Bone mineral density (BMD) and bone microarchitecture are important determinants for the mechanical properties of cancellous bone. Although BMD alone is a good predictor of average mechanical properties of cancellous bone, there remains unexplained variation in mechanical properties that might be due to missing information regarding bone microarchitecture. Recent developments in three-dimensional (3D) structural analysis have provided possibilities for measuring a variety of structural indices to characterize bone microarchitecture. The objectives of this study were to calculate structural indices and elastic constants of human cancellous bone from different skeletal sites and to investigate the predictive value of different 3D structural indices for the elastic properties of bone. A total of 237 cancellous bone samples taken from the iliac crest, lumbar spine, femoral head, and calcaneus were imaged with a 3D microcomputed tomography (microCT) system. The segmented 3D images were used to calculate BV/TV, BS/TV, Tb.Th, Tb.Sp, Tb.N, and MII ratio and for microstructural finite-element (microFE) analysis to calculate Young's moduli, shear moduli, and Poisson's ratios. A subgroup of "critical" specimens within each site was selected to represent specimens that could not be identified as osteoporotic or normal on the basis of BMD measurement alone. For these "critical" specimens, structural indices and elastic constants were correlated by means of linear multivariate regression analysis. It was found that the elastic constants clearly correlated better when one of the 3D structural indices was included as independent variable than when BV/TV was the only independent variable. Each of the examined structural indices could improve the correlation: the R2 values were maximally increased from 53% (BV/TV alone) to 82% (BV/TV and MIL ratio). The most effective indices, however, were not the same for the different skeletal sites. Even better correlations were found when more than one of the 3D structural indices were included as independent variables: the R2 values were maximally increased from 53% (BV/TV alone) to 92% (BV/TV, Tb.Sp, and MIL ratio). The prediction of elastic constants for cancellous bone samples is clearly improved when BV/TV is supplemented with 3D structural indices. These results suggest that the determination of mechanical properties of bone and the diagnosis of osteoporosis can be improved if, in addition to BMD, the 3D bone microarchitecture is assessed in vivo.

Adult↗

Direct three-dimensional morphometric analysis of human cancellous bone: microstructural data from spine, femur, iliac crest, and calcaneus.

The appearance of cancellous bone architecture is different for various skeletal sites and various disease states. During aging and disease, plates are perforated and connecting rods are dissolved. There is a continuous shift from one structural type to the other. So traditional histomorphometric procedures, which are based on a fixed model type, will lead to questionable results. The introduction of three-dimensional (3D) measuring techniques in bone research makes it possible to capture the actual architecture of cancellous bone without assumptions of the structure type. This requires, however, new methods that make direct use of the 3D information. Within the framework of a BIOMED I project of the European Union, we analyzed a total of 260 human bone biopsies taken from five different skeletal sites (femoral head, vertebral bodies L2 and L4, iliac crest, and calcaneus) from 52 donors. The samples were measured three-dimensionally with a microcomputed tomography scanner and subsequently evaluated with both traditional indirect histomorphometric methods and newly developed direct ones. The results show significant differences between the methods and in their relation to the bone volume fraction. Based on the direct 3D analysis of human bone biopsies, it appears that samples with a lower bone mass are primarily characterized by a smaller plate-to-rod ratio, and to a lesser extent by thinner trabecular elements.

Adult↗

Finite element analysis of trabecular bone structure: a comparison of image-based meshing techniques.

In this study, we investigate if finite element (FE) analyses of human trabecular bone architecture based on 168 microm images can provide relevant information about the bone mechanical characteristics. Three human trabecular bone samples, one taken from the femoral head, one from the iliac crest, and one from the lumbar spine, were imaged with micro-computed tomography (micro-CT) using a 28 microm resolution. After reconstruction the resolution was coarsened to 168 microm. First, all reconstructions were thresholded and directly converted to FE-models built of hexahedral elements. For the coarser resolutions of two samples, this resulted in a loss of trabecular connections and a subsequent loss of stiffness. To reduce this effect, a tetrahedral element meshing based on the marching cubes algorithm, as well as a modified hexahedron meshing, which thresholds the image such that load carrying bone mass is preserved, were employed. For each sample elastic moduli and tissue Von Mises stresses of the three different 168 microm models were compared to those from the hexahedron 28 microm model. For one sample the hexahedron meshing at 168 microm produced excellent results. For the other two samples the results obtained from the hexahedral models at 168 microm resolution were poor. Considerably better results were attained for these samples when using the mass-compensated or tetrahedron meshing techniques. We conclude that the accuracy of the FE-models at 168 microm strongly depends on the bone morphology, in particular its trabecular thickness. A substantial loss of trabecular connections during the hexahedron meshing process indicates that poor FE results will be obtained. In this case the tetrahedron or mass-compensated hexahedron meshing techniques can reduce the loss of connections and produce better results than the plain hexahedron meshing techniques.

Algorithms↗

Effect of mechanical set point of bone cells on mechanical control of trabecular bone architecture.

The architecture of trabecular bone is thought to be controlled by mechanosensitive bone cells, where hormones provide a background for their responses to mechanical signals. It has been suggested that, in osteoporosis, this response is hampered by changed hormonal levels, thereby increasing the mechanical set point of the cells, which would lead to bone loss. We have investigated if a temporary increase of the mechanical set point causes deterioration of trabecular bone architecture, such as seen in osteoporosis. Furthermore, the effects of a changed loading pattern were investigated for the same reason. For this purpose, we used a computer simulation model, which was based on the regulation of bone architecture by mechanosensitive osteocytes. It was found that a temporary shift of the mechanical set point causes no lasting changes in architecture. Although an increase of the mechanical set point induces bone loss, the mechanism of bone loss (trabecular thinning) differs from what is observed in osteoporosis (loss of whole trabeculae). Hence, a change of the mechanical set point alone cannot explain bone loss as seen in osteoporosis. On the other hand, the removal of load components in a particular direction resulted in irreversible loss of whole trabeculae. These results indicate that such temporary changes in loading patterns could be important risk factors for osteoporosis.

Adult↗

Morphometric analysis of human bone biopsies: a quantitative structural comparison of histological sections and micro-computed tomography.

As a part of the European Union BIOMED I study "Assessment of Bone Quality in Osteoporosis," the trabecular structure of transiliac bone biopsies was assessed by conventional histomorphometry and by three-dimensional microcomputed tomography (microCT). Sixty-three cylindrical human transiliac bone specimens were obtained post mortem from 27 women and 36 men (age 23-92 years) and evaluated morphometrically in this study. For the conventional histomorphometric analysis, a pair of four undecalcified sections were prepared from two regions in the mediolateral plane of the bone cores. The sections were stained with the von Kossa technique to obtain high-contrast two-dimensional images. Prior to the histologic sectioning the samples were measured with a desktop microCT, providing a 14 microm nominal resolution. The morphometric parameters computed by both methods in two or three dimensions, respectively, were bone volume density (BV/TV), bone surface density (BS/TV), trabecular thickness (Tb.Th), and trabecular separation (Tb.Sp). Results showed highly significant (p < 0.0001) correlations between conventional histology and microCT for BV/TV (r = 0.93), BS/TV (r = 0.91), Tb.Th (r = 0.84), and Tb.Sp (r = 0.91). The mean percentage differences between histology and microCT ranged from 2.5% (BV/TV) to 6.1% (Tb.Th). The high correlations and the low differences in terms of absolute numbers between conventional histomorphometric and microtomographic analysis are very promising for the use of micro-tomographic imaging. MicroCT is a nondestructive, fast, and very precise procedure that allows the measurement of cancellous and compact bone in unprocessed biopsies or small bones, as well as a fully automatic determination of three-dimensional morphometric indices.

Adult↗

Do quantitative ultrasound measurements reflect structure independently of density in human vertebral cancellous bone?

Ultrasonic measurements were made in three orthogonal directions on 70 vertebral bone cubes. Apparent density (rho) was determined, and microcomputed tomography was used to derive a range of microstructural parameters. Qualitatively different ultrasonic behavior was observed in the craniocaudal (CC) axis, in which two distinct waves propagated. In this direction, only attenuation correlated strongly with rho (r2 = 80%), whereas, in the anteroposterior (AP) and mediolateral (ML) axes, there were significant correlations between all ultrasonic parameters and rho (r2 = 57%-79%). Microstructural parameters were, in general, correlated with ultrasonic properties, but when adjusted for rho, few significant relationships remained and the additional variance explained by individual microstructural parameters was relatively small (< 25% for CC axis, < 3% for AP, 0% for ML). In stepwise regression analysis including rho and all of the microstructural parameters, rho remained the primary determinant of ultrasonic properties in the transverse axes: Combinations of structural parameters explained, at most, an additional of 6% of the variability in ultrasonic properties in the AP axis, but failed to contribute significantly in the ML axis. In the CC axis, structural parameters played a greater role, but the pattern of associations was complex and the predictive power of the models was generally much less than that for the transverse axes. These data indicate that the ability of ultrasound to reflect aspects of trabecular structure is strongly dependent on the direction in which ultrasonic measurements are made, and provide only qualified support for the hypothesis that ultrasound reflects cancellous bone structure independently of bone density.

Absorptiometry, Photon↗

Calibration of a portal imaging device for high-precision dosimetry: a Monte Carlo study.

Today electronic portal imaging devices (EPID's) are used primarily to verify patient positioning. They have, however, also the potential as 2D-dosimeters and could be used as such for transit dosimetry or dose reconstruction. It has been proven that such devices, especially liquid filled ionization chambers, have a stable dose response relationship which can be described in terms of the physical properties of the EPID and the pulsed linac radiation. For absolute dosimetry however, an accurate method of calibration to an absolute dose is needed. In this work, we concentrate on calibration against dose in a homogeneous water phantom. Using a Monte Carlo model of the detector we calculated dose spread kernels in units of absolute dose per incident energy fluence and compared them to calculated dose spread kernels in water at different depths. The energy of the incident pencil beams varied between 0.5 and 18 MeV. At the depth of dose maximum in water for a 6 MV beam (1.5 cm) and for a 18 MV beam (3.0 cm) we observed large absolute differences between water and detector dose above an incident energy of 4 MeV but only small relative differences in the most frequent energy range of the beam energy spectra. It is shown that for a 6 MV beam the absolute reference dose measured at 1.5 cm water depth differs from the absolute detector dose by 3.8%. At depth 1.2 cm in water, however, the relative dose differences are almost constant between 2 and 6 MeV. The effects of changes in the energy spectrum of the beam on the dose responses in water and in the detector are also investigated. We show that differences larger than 2% can occur for different beam qualities of the incident photon beam behind water slabs of different thicknesses. It is therefore concluded that for high-precision dosimetry such effects have to be taken into account. Nevertheless, the precise information about the dose response of the detector provided in this Monte Carlo study forms the basis of extracting directly the basic radiometric quantities photon fluence and photon energy fluence from the detector's signal using a deconvolution algorithm. The results are therefore promising for future application in absolute transit dosimetry and absolute dose reconstruction.

Biophysical Phenomena↗

In vivo high resolution 3D-QCT of the human forearm.

In vivo examinations of bone microarchitecture have become available recently through high resolution computed tomography (3D-QCT) and magnetic resonance imaging. The spatial resolution of the resulting images, however, is not sufficient to depict individual trabeculae in their true shape. Nevertheless, structural indices such as relative bone volume, trabecular number, mean thickness and mean separation can be extracted with the help of a ridge detection algorithm. Precision of the procedure is of the order of 1%, accuracy is ascertained using a micro-CT based calibration. In this work we report first results of time serial examinations. Eighteen healthy postmenopausal women (no HRT) were measured at months 0, 6, and 12, and the temporal changes were analyzed. Examination site was the distal radius. The above mentioned structural indices, the average densities and the thickness of the cortical shell were determined. Of the 18 women 6 showed no significant bone loss of any kind, 5 lost primarily cancellous bone, 4 lost primarily cortical bone, and 3 had a substantial loss of cortical as well as cancellous bone. We conclude that even in a homogenous group such as postmenopausal women, there are considerable differences in the reason why bone is weakened and that high resolution 3D-QCT allows to differentiate between various types of bone loss.

Bone Density↗

Micro-CT examinations of trabecular bone samples at different resolutions: 14, 7 and 2 micron level.

Tomographic techniques are attractive for the investigation of trabecular bone architecture. Using either conventional X-ray sources or synchrotron sources currently allows the acquisition of 3D images in a wide range of spatial resolution that may be as small as a few micrometers. Since it is technically possible to examine trabecular architecture at different scales, a question is to know what type of information it is possible to get at each scale. For this purpose, a series of ten vertebrae samples from healthy females of different ages (33 to 90) was imaged at various resolutions on three different micro-CT systems (cubic voxel size respectively 14, 6.7 and 1.4 microm). The comparison of morphometric parameters extracted from the different images is in agreement with simulation results on the influence of spatial resolution on structure parameters. The conclusion is that a 14 microm voxel size gives a reasonably good parameterisation of trabecular architecture. Besides the synchrotron radiation 2 microm level images reveal interesting features on the irregularities and rupture of trabecular surface, and on remodeling zones.

Adult↗

Assessment of cancellous bone mechanical properties from micro-FE models based on micro-CT, pQCT and MR images.

Recently, new micro-finite element (micro-FE) techniques have been introduced to calculate cancellous bone mechanical properties directly from high-resolution images of its internal architecture. Also recently, new peripheral quantitative computed tomography (pQCT) and magnetic resonance (MR) imaging techniques have been developed that can create images of whole bones in vivo with enough detail to visualize the internal cancellous bone architecture. In this study we aim to investigate if the calculation of cancellous bone mechanical properties from micro-FE models based on such new pQCT and MR images is feasible. Three bone specimens were imaged with the pQCT scanning system and the MR-imaging system. The specimens were scanned a second time using a micro-CT scanner with a much higher resolution. Digitized reconstructions were made based on each set of images and converted to micro-FE models from which the bone elastic properties were calculated. It was found that the results of both the pQCT and the MR-based FE-models compared well to those of the more accurate micro-CT based models in a qualitative sense, but correction factors will be needed to get accurate values.

Bone and Bones↗

Mechanical analysis of bone and its microarchitecture based on in vivo voxel images.

Prevention of osteoporotic fractures requires accurate methods to detect the increase in bone fragility at an early disease stage as well as effective therapies to reduce the risk of bone fractures. Presently the prediction of the patient-specific bone fracture risk is primarily based on bone density, since this is the only parameter which can routinely be measured in vivo. However, these predictions might not always be precise because the fracture risk is also determined by the bone microarchitecture and the bone's loading conditions. The aim of this paper is to introduce and evaluate new methods which could contribute to a better quantification of bone fracture risk. Recently, a new approach, combining computational engineering methods (finite element (FE) method) and 3D high-resolution imaging techniques, has been introduced which can account not only for bone density but also for microarchitecture and loading conditions. High-resolution imaging techniques allow acquisition of 3D images of the bone microarchitecture, whereas FE methods applied to these images allow very precise calculation of the mechanical properties of bone. However, such a detailed FE analysis was not feasible for bone in vivo mainly because the resolution was not sufficient to measure the bone microarchitecture. It is shown here, from preliminary results, that the FE approach based on high-resolution images from a new CT scanner now allows prediction of the mechanical behavior of peripheral bones in vivo. It is expected that, eventually, the FE approach will lead to a better patient-specific fracture risk prediction than earlier methods based on bone density alone. Hence, with this new approach, it might be possible to detect the increase in bone fragility at an early stage of osteoporosis and it might also be possible to evaluate treatments more accurately.

Biomechanical Phenomena↗

Prevalence of trabecular microcallus formation in the vertebral body and the femoral neck.

Trabecular microcallus formation (TMF) has been described previously in the human vertebra and femur, but the difference in TMF prevalence at these two sites has not been studied and the role of TMF remains controversial. In this study, the 4th lumbar vertebra (L4) and right proximal femur were removed from 27 male and 23 female cadavers. A 2 cm cube cut from the center of L4 and a 1 cm-thick slice cut from the femoral neck were cleaned, defatted, and dried. The apparent density of the L4 cubes was determined as dry weight/bulk bone volume. Using a dissecting microscope at low magnification (4-60x), TMF were identified and counted in both the vertebral and femoral samples. A 8 mm diameter core was then cut from the center of the L4 cubes in the vertical direction, and selected histomorphometric parameters of the core were evaluated with an X-ray microcomputed tomography system (micro-CT). There was a significantly greater prevalence of TMF in vertebral cubes (82%) than in the femoral slices (11%) (P < 0.001). TMF prevalence did not differ significantly between males and females, but the mean number of TMF in the vertebra was significantly (P < 0.05) greater in females (15.0/vertebra) than in males (7.7/vertebra). In the vertebra, the majority of the observed TMF were in vertical trabeculae. Subjects over 60 years old had a higher TMF prevalence than those under 60 years old (P < 0.01). TMF numbers increased with decreasing apparent density (P < 0.05), whereas no significant correlations were found between TMF and bone volume (BV/TV), trabecular number (Tb.N), or trabecular thickness (Tb.Th) as assessed by micro-CT. In two fractured vertebra, very few TMFs (2 and 4, respectively) were observed. These results demonstrated that the occurrence of TMF is strongly related to the anatomical site, probably due to differences in the applied loads and the trabecular structure between sites. The results were consistent with the hypothesis that TMF is a mechanism acting to maintain bone strength, but further studies are needed to clarify this important issue.

Adult↗

Ridge number density: a new parameter for in vivo bone structure analysis.

An advanced analysis of the mechanical properties of bone should include information about the microarchitecture of cancellous bone in addition to its density. It has recently been shown that high-resolution quantitative computed tomography and magnetic resonance imaging have the potential to assess such information in a noninvasive way in patients. Both techniques, however, lack sufficient spatial resolution to image the individual trabeculae with true precision. In this work, a new parameter, Ridge number density (RND), is introduced. RND is a measure for the trabecular number, which can be extracted directly from high-resolution three-dimensional (3D) images of patients. We applied the RND technique to a test group of nine healthy, postmenopausal women measured repetitively with a high-resolution 3D peripheral quantitative computed tomography (3D-pQCT) system with 165 x 165 x 165 microm3 voxel size. Simultaneously with the RND determination, the trabecular bone density (TBD) was also assessed in the same volume of interest. The examination site was the distal radius. The intersubject variability of the measured test group was 10.5% for RND and 26.3% for TBD. The root mean square error between first and second examinations (midterm reproducibility) was 1.6% and 1.1%, respectively. RND is determined independently from TBD and pertains to the structure of the cancellous bone. As such, it might add crucial information in cases where bone mass or bone density measurements alone give ambiguous results.

Bone Density↗

Micro-tomographic imaging for the nondestructive evaluation of trabecular bone architecture.

The structural properties of trabecular bone have been shown to vary significantly with age, anatomic location, and metabolic condition. Micro-computed tomography (microCT) is an emerging technique for the nondestructive assessment and analysis of the three-dimensional trabecular bone architecture. Within the framework of the European Union BIOMED I project "Assessment of Bone Quality in Osteoporosis," a total of 350 bone biopsies from five different anatomical locations were harvested post mortem from 70 donors (aged 23 to 92 years). These biopsies were measured using a newly devised compact micro-tomographic system, also referred to as desk-top microCT. Samples with a diameter from a few millimeters to a maximum of 18 mm and a length of up to 55 mm can be measured. For this study fresh, untreated bone biopsies with a diameter of 8 mm were measured micro-tomographically with a nominal isotropic resolution of 14 microns. For all samples, the volumes of interest (4 x 4 x 4 mm3) were binarized using a uniform threshold. Subsequently, standard structural indices such as bone volume density (BV/TV), bone surface density (BS/BV), trabecular plate number (Tb.N), trabecular thickness (Tb.Th), trabecular separation (Tb.Sp) and the degree of anisotropy (DA) were computed for all specimens incorporating mean intercept length (MIL) measurements. Regression analysis was used to estimate the correlations of single structural parameters with age or with a second parameter and also among different measurement sites. The nondestructive microCT measurements allowed not only to perform quantitative bone morphometry but also to assess other important microstructural features in the determination of the mechanical integrity of trabecular bone such as the incidence and prevalence of microcallus formations. The findings from the BIOMED I study are expected to improve our understanding of the relative importance of bone architecture, damage accumulation, and bone mineralization in the characterization of bone quality in the progress of age- and disease-related bone loss.

Adult↗