The quality of trabecular bone evaluated with micro-computed tomography, FEA and mechanical testing.

Most standard methods to predict bone quality are merely based on apparent density measurements. However, apparent density alone does neither explain all variation of the mechanical properties nor does it account for the structural anisotropy of trabecular bone. Thus, apparent density alone might not be sufficient to accurately predict the quality of bone. This study investigates if a new approach based on microstructural computer models can provide additional and relevant information on bone quality. 58 human trabecular bone samples from the femoral head were measured with a 3-D micro-Computed Tomography (micro-CT) system providing a voxel representation of the bone microarchitecture with a resolution of 28 microns. Based on such representations, the orthotropic stiffness matrices and the principal directions were computed for 5 mm cubes with microstructural Finite Element Analysis (FEA). For a subset of six samples the moduli were then validated with tri-axial mechanical compression tests. The results show that on average 15% of the variation of the elastic properties are not explained by bone volume fraction. Differences of elastic properties between samples with the same bone volume fraction range up to 53%. The variation of the degree of anisotropy is unrelated to that of the bone volume fraction. Finally, the direction-dependent stiffness of the trabecular bone differs by a factor of four, indicating that one single (isotropic) modulus as predicted from apparent density measurements might not be adequat. It is concluded that micro-CT-based FEA provides new and additional information about anisotropy and mechanical properties in a direct and non-destructive way, and thus will be important in the future for advanced failure risk prediction. An extension to patient examinations using high-resolution CT or MRI techniques is envisaged.

Biomechanical Phenomena↗

In vivo reproducibility of three-dimensional structural properties of noninvasive bone biopsies using 3D-pQCT.

Trabecular bone architecture is one of the main factors influencing the mechanical behavior of cancellous bone. To assess the three-dimensional trabecular microstructure of intact bones, we introduced the concept of noninvasive bone biopsy, a method to assess and analyze cancellous bone based upon three-dimensional peripheral quantitative computed tomography in vivo (3D-pQCT). The aim of this work was to demonstrate the potential of noninvasive bone biopsies as a basis for structural and mechanical analysis of trabecular bone in the process of rapid bone loss. A group of six healthy young male volunteers was measured to provide data on the reproducibility of structural parameters. Baseline and 1-month follow-up measurements were performed to provide data on short-term precision of the procedure, and three of the controls were reanalyzed within 3-6 months to estimate long-term precision. Prior to structural evaluation, the baseline and follow-up measurements were repositioned three-dimensionally to ensure matching volumes of interest (VOI). Trabecular bone density (TBD) as well as structural indices were analyzed for all measurements. The VOIs were analyzed morphometrically by evaluating bone volume (BV/TV) and trabecular number (Tb.N) based on a direct three-dimensional approach. Trabecular thickness (Tb.Th) and trabecular separation (Tb.Sp) were derived from these two indices. The data of the measurements at 1 month to determine the short-term precision was in excellent agreement with the baseline measurements. The results showed that structural parameters can be reproduced in vivo with a coefficient of variation of less than 0.5%. With a typical spread of 4% for the structural indices within the group of healthy volunteers, an intraclass correlation of better than 0.98 was reached. We conclude that high-resolution 3D-pQCT has the potential to detect structural changes in trabecular bone during therapeutic and diagnostic trials.

Adult↗

A microtomographic system for the nondestructive evaluation of bone architecture.

Microtomography (micro-computed-tomography, mu-CT) is a method to image and quantify trabecular bone. It has the capability to address the role of trabecular architecture on the mechanical properties of bone and to study trabecular bone remodeling. The system described in this work is based on a compact fan-beam type tomograph that can work in spiral scanning or multislice mode. An X-ray tube with a microfocus is used as a source, a CCD-array as a detector. Samples with diameters from a few millimeters to a maximum of 14 mm can be measured, typically, bone biopsies with a diameter of 8 mm and a length of approximately 10 mm are measured. Spatial resolution is 28 microns. Usually the volume of interest contains 4 x 4 x 4 mm3 and is represented in 14 x 14 x 14 microns3 voxels. 3D stereological indices are extracted according to the standard definitions used in histomorphometry. Triangular surface representation is effected with an extended marching cube algorithm and forms a convenient basis for finite element analysis. Microtomographic measurements may be employed to "calibrate" lower-dose, lower-resolution images in vivo as well as to nondestructively assess unprocessed surgical bone biopsy specimens. These specimens remain intact for mechanical or histological testing.

Bone and Bones↗

Analysis of mechanical properties of cancellous bone under conditions of simulated bone atrophy.

The mechanical properties of cancellous bone have been shown to depend on bone density and on the anisotropy of the trabecular bone structure. By means of high-resolution quantitative computed tomography (QCT), providing a nominal resolution of 0.17 mm, it became possible to assess both apparent density and trabecular microstructure of intact bones. In order to study the influence of age- and disease-related bone loss on the mechanical properties of cancellous bone, a more phenomenological approach was used to develop a novel bone resorption algorithm, called simulated bone atrophy. The algorithm, which is principally based on constrained Gauss filtration of segmented data volumes, was applied to create derived microstructural models. The mechanical behavior of the cancellous bone can be expressed as a function of the anisotropic bone properties of the microstructural model on the continuum level. To study the influence of bone atrophy on bone strength we compared three models: the originally noninvasively measured bone biopsy and two derived models simulating moderate and pronounced atrophy. For the comparison of the three models, the apparent Young's moduli in the three orthogonal directions were predicted for each model with the help of three-dimensional finite-element analysis. Realistic results for the apparent Young's moduli were found for the tissue moduli chosen. The results suggest that the prediction of anisotropic material properties of cancellous bone based on noninvasive measurements of trabecular microstructures and the application of simulated bone atrophy may be helpful to understand the influence of age- and disease-related bone loss on bone strength.

Atrophy↗

Morphometric analysis of noninvasively assessed bone biopsies: comparison of high-resolution computed tomography and histologic sections.

This article describes a new method to analyze the structural behavior of trabecular bone structure by means of noninvasive measurements of the three-dimensional cancellous bone architecture. For the noninvasive data acquisition, a high-resolution quantitative computed tomography system for peripheral measuring sites (pQCT) was used. With this system and the help of a multiple thin-slice measuring technique, it became possible to examine three-dimensional bone structure with a resolution of 0.25 mm. Using a special three-dimensional segmentation algorithm, mineralized bone was separated from bone marrow and muscle tissue within the three-dimensional stack of CT slices. These segmented data sets can then be processed nondestructively and, even more important, repetitively in either two or three dimensions. In order to validate this noninvasive procedure, a two-dimensional comparative morphometric study was performed including CT slices and corresponding histologic sections prepared after CT measurement. Three representative sections from the three-dimensional stack of CT slices were selected and the morphometric indices of the segmented CT slices were compared with the indices stemming from the corresponding histologic sections prepared after CT measurement. Although the presented approach can only give an example of the method, the results from the morphometric analysis support the assumption that cancellous bone structures based on noninvasive high-resolution CT measurements are representative for trabecular microstructures assessed from histologic bone sections. The study demonstrates the potential of high-resolution CT imaging for in vivo applications of quantitative bone morphometry. This is especially true for repetitive follow-up measurements, which cannot be performed using histologic sections. Additionally, the method offers an easy access to the three-dimensional structure of trabecular bone, which is mandatory for the analyses of the anisotropic mechanical behavior of cancellous bone.

Algorithms↗

Automated finite element analysis of excised human femora based on precision -QCT.

The creation of 3-D finite element (FE) models of bone and implant-bone systems is a labor-intensive task due to the need to model different cases and variations, to perform patch tests and to account for the nonhomogeneous material properties with an acceptable amount of work. In this study, we developed an interface between a precision QCT and a FE system and applied it to a specimen bone. With the new method, the time necessary for model generation was reduced substantially. Furthermore, the elastic properties for each element were automatically derived from the corresponding CT-values. In order to demonstrate the importance of taking into account inhomogeneity, a comparison between the nonhomogeneous model and a homogeneous, "averaged" model was performed.

Biomechanical Phenomena↗

Resolution dependency of microstructural properties of cancellous bone based on three-dimensional mu-tomography.

Micro-computed tomography (microCT) is an emerging technique for the non-destructive assessment and analysis of the three-dimensional cancellous bone architecture. However, the procedures the procedures and applications used to quantify bone structures are not yet standardized. The aim of this study was to provide more insight in the resolution-dependency of microstructural properties of three-dimensional trabecular bone. Ten iliac crest bone biopsies were measured using a newly devised microCT system providing a nominal isotropic resolution of 14 microns. To study the resolution dependency the measured data were reconstructed on reduced image arrays with reduction factors ranging from 2 to 20. To assess the structural properties, morphometric parameters were computed based on a truly three-dimensional approach. The results showed a strong resolution dependency of the structural properties and that, if very precise results are needed, only the highest resolution will predict the correct values. Nevertheless, since the properties either decrease or increase monotonously up to a nominal resolution of about 175 microns, the values appear to be restorable using a suitable calibration procedure.

Bone Matrix↗

Comparison of the treatment effects of ossein-hydroxyapatite compound and calcium carbonate in osteoporotic females.

The aim of the study was to evaluate whether ossein-hydroxyapatite (OHC) is more effective than calcium carbonate (CC) in preventing further bone loss in postmenopausal osteoporosis. Forty osteoporotic patients were monitored for 20 months. The patients were randomly assigned to one of two groups and treated in a double-masked manner with 1400 mg calcium per day, in the form of either OHC or CC. OHC consists of hydroxyapatite, collagens and non-collagenous proteins/peptides containing insulin-like growth factor I (IGF-I; 1341 ng), insulin-like growth factor II (IGF-II; 670 ng), transforming growth factor beta (TGF-beta; 166 ng) and osteocalcin (47 micrograms). The bone densities were evaluated at intervals of 4 months with high-precision peripheral quantitative computed tomography. After 20 months of treatment the loss of trabecular bone was 0.8 +/- 0.5% in the OHC group and 1.8 +/- 0.7% in the CC group. The difference between the OHC and CC groups was statistically significant. This study shows that OHC is more effective than CC in slowing peripheral trabecular bone loss in patients with manifest osteoporosis.

Aged↗

European semi-anthropomorphic spine phantom for the calibration of bone densitometers: assessment of precision, stability and accuracy. The European Quantitation of Osteoporosis Study Group.

Up to now it has not been possible to reliably cross-calibrate dual-energy X-ray absorptiometry (DXA) densitometry equipment made by different manufacturers so that a measurement made on an individual subject can be expressed in the units used with a different type of machine. Manufacturers have adopted various procedures for edge detection and calibration, producing various normal ranges which are specific to each individual manufacturer's brand of machine. In this study we have used the recently described European Spine Phantom (ESP, prototype version), which contains three semi-anthropomorphic "vertebrae" of different densities made of stimulated cortical and trabecular bone, to calibrate a range of DXA densitometers and quantitative computed tomography (QCT) equipment used in the measurement of trabecular bone density of the lumbar vertebrae. Three brands of QCT equipment and three brands of DXA equipment were assessed. Repeat measurements were made to assess machine stability. With the large majority of machines which proved stable, mean values were obtained for the measured low, medium and high density vertebrae respectively. In the case of the QCT equipment these means were for the trabecular bone density, and in the case of the DXA equipment for vertebral body bone density in the posteroanterior projection. All DXA machines overestimated the projected area of the vertebral bodies by incorporating variable amounts of transverse process. In general, the QCT equipment gave measured values which were close to the specified values for trabecular density, but there were substantial differences from the specified values in the results provided by the three DXA brands. For the QCT and Norland DXA machines (posteroanterior view), the relationships between specified densities and observed densities were found to be linear, whereas for the other DXA equipment (posteroanterior view), slightly curvilinear, exponential fits were found to be necessary to fit the plots of observed versus specified densities. From these plots, individual calibration equations were derived for each machine studied. For optimal cross-calibration, it was found to be necessary to use an individual calibration equation for each machine. This study has shown that it is possible to cross-calibrate DXA as well as QCT equipment for the measurement of axial bone density. This will be of considerable benefit for large-scale epidemiological studies as well as for multi-site clinical studies depending on bone densitometry.

Absorptiometry, Photon↗

Three-dimensional finite element modelling of non-invasively assessed trabecular bone structures.

The three-dimensional microstructure of cancellous bone seems to be one of the key factors in the prediction of mechanical bone properties like bone strength or bone stiffness. In this paper trabecular bone structure was assessed nondestructively by means of high-resolution computed tomography (CT) with a spatial resolution of 250 microns. Mineralized bone was separated from bone marrow and muscle tissue with the help of a three-dimensional segmentation algorithm based on the analysis of directional derivatives. From the three-dimensional stack of CT slices a subvolume comparable in size (3.6 x 3.4 x 3.4 mm3) to standard histologic bone sections was selected. We refer to this subvolume as non-invasive bone biopsy. A new automated mesh generator was developed to create a three-dimensional finite element model of the non-invasive bone biopsy. Four-noded tetrahedron solid elements were used to guarantee a smooth surface representation. The aim of the presented work was to demonstrate the potential of high-resolution CT imaging in the prediction of the anisotropic material properties of cancellous bone. Preliminary results of the 3D finite element stress analysis are very promising. The predicted value of the apparent Young's modulus (564 MPa) is within the range reported for uniaxial compression testings of cancellous bone specimens.

Algorithms↗

Cancellous bone graft for skeletal reconstruction. Muscular versus periosteal bed--preliminary report.

The purpose of this project was to verify the value of perfused periosteum as a possibly ideal bed for autogenous cancellous bone graft. The model consisted of a 7 cm defect in the sheep tibia, stabilized with a locked intramedullary nail. The defect was filled with conventional cortico-cancellous bone graft covered either with a muscle or a perfused osteoperiosteal flap. The incorporation of the graft was analysed by a series of radiological and mechanical examinations. The graft embedded in perfused osteo-periosteum was rapidly remodelled to a strong, circular bone. Mechanical testing revealed even better values than for normal bone. The graft embedded in muscle showed an important resorptive phase before scanty, incomplete, reconstitution of bone appeared. Mechanical properties were poor. The study supports the hypothesis that perfused osteo-periosteum is an ideal bed for cancellous bone graft and that perfused muscle is not the ideal environment for incorporation of the graft.

Animals↗

Non-invasive bone biopsy: a new method to analyse and display the three-dimensional structure of trabecular bone.

Three-dimensional structure is one of the main factors influencing the mechanical behaviour of cancellous bone. To analyse the trabecular bone structure non-destructively we used a peripheral QCT system and applied a special thin-slice technique to create high-resolution volumetric data sets serving as a basis for something we would like to call non-invasive bone biopsy. In order to obtain binary data sets, the mineralized bone in the CT volume was separated from bone marrow and muscle tissue with the help of a sophisticated three-dimensional segmentation algorithm based on the analysis of directional derivatives, which are computed from a locally approximated fit function of the original CT volume. Binary volumes including either a solid representation of trabecular plates and rods or a topological representation of the cancellous bone architecture were acquired. Such volumes can be processed non-destructively and, even more important, repetitively. By using a surface reconstruction algorithm based on interpolating triangulation it was possible to visualize the three-dimensional surface of the trabecular bone structure. The results showed that surface representation and visualization in combination with a multiple thin-slice measuring technique are valuable tools in studying three-dimensional bone architecture. In the future, the non-invasive bone biopsies will be evaluated by means of three-dimensional mechanical analysis incorporating finite element modelling and direct morphological investigations of the cancellous bone architecture for a better prediction of bone strength as an index for fracture risk or osteoporosis.

Biopsy↗

[Bone density measurements and their indications].

Today the following two methods of measuring the bone mineral density (BMD) are widely used: dual-photon absorptiometry with X-rays (DEXA) and quantitative computed tomography (qCT). DEXA measures the BMD of the vertebral column, the femur and the whole skeleton, qCT the vertebral column and the radius and tibia. The qCT method permits a distinction to be made between trabecular and cortical bone, which offers an advantage in terms of the choice of treatment because cortical and trabecular bone do not change in parallel. For example, fluorides are contraindicated when cortical bone is diminished. There are important differences among the methods of densitometry concerning reproducibility. The highly sensitive method of peripheral qCT (Densiscan) has an overall reproducibility of 0.3% (mixed population), allowing a change in BMD of less than 1% to be detected. This enables us to adapt quickly the treatment according to the stage and progression of the disease. In the perimenopausal patient, bone mineral densitometry is indicated to detect high-risk patients; in the postmenopause patient, densitometry should be performed in order to "tailor" the treatment of osteoporosis. Patients with a "slow loser" osteoporosis are preferably treated with bone-simulating substances (e.g., fluorides, ossein-hydroxyapatite compound), patients with a "fast loser" osteoporosis (trabecular bone loss, measured at the distal radius, of more than 3.5% per year) with anti-resorption agents such as estrogens, bisphosphonates, calcitonin and anabolic steroids. This tailored treatment reduces not only the number of non-responders, but improves patient compliance because it allows the choice, duration or change of the treatment to be substantiated by means of hard data.(ABSTRACT TRUNCATED AT 250 WORDS)

Absorptiometry, Photon↗

[Loss of bone mass in patients with anorexia on tube feeding and its prevention with biphosphonates].

Women with long-lasting anorexia nervosa often display osteopenia. Furthermore, we have observed additional marked loss of bone mass under tube feeding in underweight anorexia patients. Such loss of bone substances can lead to spontaneous fractures. Therefore, we investigated in this study whether this undesirable effect of tube-feeding might be prevented by administration of bisphosphonates (Didronel), a substance that inhibits the activity of osteoclasts. Bone density was assessed by a high-precision, low dose, quantitative computed tomography of the distal radius and the distal tibia. A group of 6 anorexia patients (tube feeding with an initial underweight of 74.9 +/- 10.3% of ideal weight, mean +/- SD) treated with bisphosphonates showed only slight loss of trabecular bone (0.8 +/- 0.2%, mean +/- SEM) after 2 months of observation, whereas in 2 control groups a marked diminution of trabecular bone was observed (4.4 +/- 0.7% and 7.6 +/- 1.1% respectively, p less than 0.001 for each comparison). Cortical bone was unchanged throughout. Treatment with bisphosphonates provides effective prevention of bone loss observed in tube-feeding.

Adult↗

Bone loss in patients with rheumatoid arthritis--effect of steroids measured by low dose quantitative computed tomography.

For 2 years bone density changes in patients with rheumatoid arthritis were monitored to determine the effect of low dose corticosteroid treatment. Sixteen perimenopausal females were studied. Of these nine were treated with 5 to 20 mg prednisone per day and seven had no steroids. The differential effects on trabecular bone density and on cortical bone in the radius and the tibia were examined with high precision peripheral quantitative computed tomography (QCT). Steroid therapy did not influence cortical bone loss and had only a minor influence on trabecular bone density. Of greater importance was the influence of estrogen depletion. Corticosteroids and estrogen depletion, however, cannot explain fully the yearly loss of 5.7% in the trabecular and 4% in the cortical bone of the radius.

Adult↗

Localization of regional forearm bone loss from high resolution computed tomographic images.

The precise site of bone loss was evaluated in early postmenopausal women using high resolution computed tomographic (CT) images of forearm measurements. A procedure was devised to quantitate trabecular and subcortical bone density of the distal radius, cortical bone density of the diaphyseal radius, and cortical wall thickness at both measuring sites. Twenty women (mean age 52 years, time since menopause 1 to 4 years) were examined twice at one-year intervals to determine the yearly change of the above mentioned bone parameters. Trabecular bone and subcortical bone showed the same density reduction of 7 mg/cm3 per year. Cortical bone density remains unchanged and no increase in porosity can be seen. For early postmenopausal women the reduction of bone mass (BMC) in the diaphysis of the radius is, therefore, due to a thinning of the cortical wall. This is in accordance with the observed average loss of wall thickness of 0.04 mm per year. The non-invasive determination of the precise localization of bone changes in individual patients should be of value in the assessment of the severity of osteoporosis. Furthermore it has potential in the evaluation of the efficacy of therapeutic procedures in the various disease states.

Absorptiometry, Photon↗

Differential effects of aging and disease on trabecular and compact bone density of the radius.

We constructed a special purpose CT system to get a spatial resolution of 0.2 mm and developed a procedure for the precise determination of trabecular and compact bone density (TBD and CBD) in the radius. Seven groups of healthy females and patients were measured to explore differential effects on compact and trabecular bone. In healthy females CBD remains constant within 0.2% from age 20 to 70. TBD measured in the same individuals is reduced by 50%. The scatter of the individual CBD values is 1.5% only, that of TBD 20%. Longitudinal examinations of corticosteroid treated asthmatics during one year showed a loss of TBD of 4.8%. During the same period CBD remained completely stable. In other diseases such as hyperparathyroidism CBD is reduced as well. This study showed the feasibility of a noninvasive determination of the density of compact bone and demonstrated that density loss of compact and trabecular bone is considerably different.

Adrenal Cortex Hormones↗