Search PubMed⌕ Search

Biomedical subjects

P Rüegsegger

Publications and source records attributed to P Rüegsegger.

At least 19 recordsLinked to original sources

Image-based micro-finite-element modeling for improved distal radius strength diagnosis: moving from bench to bedside.

Although osteoporosis is characterized by quantitative (mass) and qualitative (structural) changes, standard clinical techniques (dual-energy X-ray absorptiometry, DXA) only measure the former. Three-dimensional micro-finite-element (micro-FE) models based on high-resolution images can account for structural aspects as well, and it has recently been shown that an improved prediction of distal radius strength is possible with micro-FE analysis. A clinical application of this technique, however, is limited by its high imaging and computational demands. The objective of this study is to investigate if an improved prediction of bone strength can be obtained as well when only a small part of the radius is used for micro-FE modeling. Images of a 1-cm region of the metaphysis of the distal radius of 54 cadaver arms (mean age: 82 +/- 9 SD) made with a three-dimensional peripheral quantitative computed tomography (pQCT) device at 165- micro m resolution formed the basis for micro-FE models that were used to predict the bone failure load. Following imaging, specimens were experimentally compressed to failure to produce a Colles'-type fracture. Failure loads predicted from micro-FE analyses agreed well with those measured experimentally (R2 = 0.66, p < 0.001). Lower correlations were observed with bone mass (R2 = 0.48, p < 0.001) and microstructural parameters (R2 = 0.47, p < 0.001). Hence, even when only a small region is modeled, micro-FE analysis provides an improved prediction of radius strength.

Absorptiometry, Photon↗

Mechanical consequences of different scenarios for simulated bone atrophy and recovery in the distal radius.

Metabolic bone diseases such as osteoporosis usually cause a decrease in bone mass and a deterioration of bone microarchitecture leading to a decline in bone strength. Methods to predict bone strength in patients are currently based on bone mass only. It has been suggested that an improved prediction of bone strength might be possible if structural changes are taken into account as well. In this study we evaluated which structural parameters (other than bone mass) are the best predictors for changes in bone mechanical properties of the human radius after different bone atrophy scenarios and whether the original strength of the affected bone can be recovered if bone loss is restored by thickening of the remaining structures. To answer these questions, a human radius was measured with a microcomputer tomography scanner to extract the full three-dimensional architecture of the distal radius at an isotropic resolution of 80 microm. Eight models with modified bone architecture were created and the mechanical variations due to these modifications were studied using microfinite element (micro-FE) simulations. In four models mass was lowered by 20%, either by reducing cortical thickness, trabecular thickness, or number of trabeculae or by overall thinning of structures. In the other four models bone mass was restored to the original value using a trabecular bone thickening procedure. The micro-FE analyses revealed that most load was carried by the cortical bone. For this reason, bone strength was affected most in the reduced cortical thickness model. For the same reason, the trabecular bone atrophy scenarios, all of which affected bone strength in a very similar way, resulted in less dramatic bone strength reduction. The restoration of bone mass did not recover the original bone strength. These findings demonstrate that the importance of different parameters for the prediction of bone strength also depends on the mechanical loading. This could explain why results of earlier studies on the importance of structural parameters can be inconsistent and site-dependent.

Adult↗

Trabecular bone tissue strains in the healthy and osteoporotic human femur.

UNLABELLED: Quantitative information about bone tissue-level loading is essential for understanding bone mechanical behavior. We made microfinite element models of a healthy and osteoporotic human femur and found that tissue-level strains in the osteoporotic femoral head were 70% higher on average and less uniformly distributed than those in the healthy one. INTRODUCTION: Bone tissue stresses and strains in healthy load-adapted trabecular architectures should be distributed rather evenly, because no bone tissue is expected to be overloaded or unused. In this study, we evaluate this paradigm with the use of microfinite element (microFE) analyses to calculate tissue-level stresses and strains for the human femur. Our objectives were to quantify the strain distribution in the healthy femur, to investigate to what extent this distribution is affected by osteoporosis, to determine if osteoporotic bone is simply bone adapted to lower load levels, and to determine the "safety factor" for trabecular bone. MATERIALS AND METHODS: microFE models of a healthy and osteoporotic proximal femur were made from microcomputed tomography images. The models consisted of over 96 and 71 million elements for the healthy and osteoporotic femur, respectively, and represented their internal and external morphology in detail. Stresses and strains were calculated for each element and their distributions were calculated for a volume of interest (VOI) of trabecular bone in the femoral head. RESULTS: The average tissue-level principal strain magnitude in the healthy VOI was 304 +/- 185 microstrains and that in the osteoporotic VOI was 520 +/- 355 microstrains. Calculated safety factors were 8.6 for the healthy and 4.9 for the osteoporotic femurs. After reducing the force applied to the osteoporotic model to 59%, the average strain compared with that of the healthy femur, but the SD was larger (208 microstrains). CONCLUSIONS: Strain magnitudes in the osteoporotic bone were much higher and less uniformly distributed than those in the healthy one. After simulated joint-load reduction, strain magnitudes in the osteoporotic femur were very similar to those in the healthy one, but their distribution is still wider and thus less favorable.

Aged↗

Estimation of distal radius failure load with micro-finite element analysis models based on three-dimensional peripheral quantitative computed tomography images.

There is increasing evidence that, in addition to bone mass, bone microarchitecture and its mechanical load distribution are important factors for the determination of bone strength. Recently, it has been shown that new high-resolution imaging techniques in combination with new modeling algorithms based on the finite element (FE) method can account for these additional factors. Such models thus could provide more relevant information for the estimation of bone failure load. The purpose of the present study was to determine whether results of whole-bone micro-FE (microFE) analyses with models based on three-dimensional peripheral quantitative computer tomography (3D-pQCT) images (isotropic voxel resolution of 165 microm) could predict the failure load of the human radius more accurately than results with dual-energy X-ray absorptiometry (DXA) or bone morphology measurements. For this purpose, microFE models were created using 54 embalmed cadaver arms. It was assumed that bone failure would be initiated if a certain percentage of the bone tissue (varied from 1% to 7%) would be strained beyond the tissue yield strain. The external force that produced this tissue strain was calculated from the FE analyses. These predictions were correlated with results of real compression testing on the same cadaver arms. The results of these compression tests were also correlated with results of DXA and structural measurements of these arms. The compression tests produced Colles-type fractures in the distal 4 cm of the radius. The predicted failure loads calculated from the FE analysis agreed well with those measured in the experiments (R(2) = 0.75 p < 0.001). Lower correlations were found with bone mass (R(2) = 0.48, p < 0.001) and bone structural parameters (R(2) = 0.57 p < 0.001). We conclude that application of the techniques investigated here can lead to a better prediction of the bone failure load for bone in vivo than is possible from DXA measurements, structural parameters, or a combination thereof.

Aged↗

Dietary essential amino acid supplements increase bone strength by influencing bone mass and bone microarchitecture in ovariectomized adult rats fed an isocaloric low-protein diet.

This study was designed to investigate whether the administration of dietary essential amino acid supplements in adult rats made osteoporotic by estrogen deficiency and reduced protein intake could reverse the deleterious effects caused by these maneuvers. This animal model was selected to mimic the situation observed in elderly women in whom estrogen deficiency and/or low-protein intake (but also calcium and vitamin D deficiency) are known to contribute to the pathogenesis of osteoporosis. Six-month-old rats were ovariectomized (OVX) and fed an isocaloric 2.5% casein diet for 10 weeks or sham-operated (SHAM) and fed an isocaloric 15% casein diet. The animals fed the 2.5% casein diet were given isocaloric supplements of essential amino acids in similar relative proportion to that of casein at doses of 2.5% or 5% of total diet for an additional 16 weeks. Vertebrae, femur, and tibia bone mineral density (BMD); ultimate strength; and microtomographic histomorphometry were evaluated before and after dietary essential amino acid supplements. Essential amino acid supplements increased vertebrae, femur, and tibia bone strength in OVX rats fed a low-protein diet. The mechanical changes induced by this dietary isocaloric supplement were associated with the prevention of a further BMD decrease or even with some increases and changes in microarchitecture such as from a rod to a plate trabecular spacial configuration and increased cortical thickness. Higher insulin-like growth factor (IGF) I levels, as well as greater bone formation and reduced bone resorption as assessed by biochemical markers of bone remodeling, were found in rats receiving essential amino acid supplements. In conclusion, dietary essential amino acid supplements increased bone strength through modifications of BMD, trabecular architecture, and cortical thickness possibly by an IGF-I-mediated process.

Amino Acids, Essential↗

Introduction and evaluation of a gray-value voxel conversion technique.

In micro finite element analyses (microFEA) of cancellous bone, the 3D-imaging data that the FEA-models are based on, contain a range of gray-values. In the construction of the eventual FEA-model, these gray-values are commonly thresholded. Although thresholding is successful at small voxel sizes, at larger voxel sizes there is substantial loss of trabecular connectivity. We propose a new method: the gray-value method, where the microFEA-models use the information within the 3D-imaging data directly, without prior thresholding. Our question was twofold. First, how does the gray-value method compare to both plain and mass-compensated thresholding? Second, what is the effect of element size on the results obtained with the gray-value method? We used nine microCT-scans of human vertebral cancellous bone. These were degraded to represent different resolutions, and converted into microFEA-models using plain thresholding, mass-compensated thresholding, and the gray-value method. The apparent elastic moduli of the specimens were determined using microFEA. The different methods were compared on the basis of the apparent elastic moduli, compared to those calculated for a 28 microm reference model. The results showed that the gray-value method greatly improves the results relative to other methods. The gray-value method gives accurate predictions of the apparent elastic moduli, for voxel sizes up to one trabecular thickness (Tb.Th.). For voxel sizes greater than one Tb.Th. the accuracy, although still better than for both thresholding methods, becomes increasingly worse.

Biomechanical Phenomena↗

Monte Carlo simulation of a dynamic MLC: implementation and applications.

PURPOSE: Study of behavior and influence of a multileaf collimator (MLC) on dose calculation, verification, and portal energy spectra in the case of intensity-modulated fields obtained with a step-and-shoot or a dynamic technique. METHODS: The 80-leaf MLC for the Varian Clinac 2300 C/D was implemented in a previously developed Monte Carlo (MC) based multiple source model (MSM) for a 6 MV photon beam. Using this model and the MC program GEANT, dose distributions, energy fluence maps and energy spectra at different portal planes were calculated for three different MLC applications. RESULTS: The comparison of MC-calculated dose distributions in the phantom and portal plane, with those measured with films showed an agreement within 3% and 1.5 mm for all cases studied. The deviations mainly occur in the extremes of the intensity modulation. The MC method allows to investigate, among other aspects, dose components, energy fluence maps, tongue-and-groove effects and energy spectra at portal planes. CONCLUSION: The MSM together with the implementation of the MLC is appropriate for a number of investigations in intensity-modulated radiation therapy (IMRT).

Computer Simulation↗

Monte Carlo simulation of a dynamic MLC based on a multiple source model.

Detailed knowledge of the characteristics of the radiation field shaped by a multileaf collimator (MLC) is essential in intensity modulated radiotherapy (IMRT). A previously developed multiple source model (MSM) for a 6 MV beam was extended to a 15 MV beam and supplemented with an accurate model of an 80-leaf dynamic MLC. Using the supplemented MSM and the MC code GEANT, lateral dose distributions were calculated in a water phantom and a portal water phantom. A field which is normally used for the validation of the step and shoot technique and a field from a realistic IMRT treatment plan delivered with dynamic MLC are investigated. To assess possible spectral changes caused by the modulation of beam intensity by an MLC, the energy spectra in five portal planes were calculated for moving slits of different widths. The extension of the MSM to 15 MV was validated by analysing energy fluences, depth doses and dose profiles. In addition, the MC-calculated primary energy spectrum was verified with an energy spectrum which was reconstructed from transmission measurements. MC-calculated dose profiles using the MSM for the step and shoot case and for the dynamic MLC case are in very good agreement with the measured data from film dosimetry. The investigation of a 13 cm wide field shows an increase in mean photon energy of up to 16% for the 0.25 cm slit compared to the open beam for 6 MV and of up to 6% for 15 MV, respectively. In conclusion, the MSM supplemented with the dynamic MLC has proven to be a powerful tool for investigational and benchmarking purposes or even for dose calculations in IMRT.

Computer Simulation↗

A multiple source model for 6 MV photon beam dose calculations using Monte Carlo.

A multiple source model (MSM) for the 6 MV beam of a Varian Clinac 2300 C/D was developed by simulating radiation transport through the accelerator head for a set of square fields using the GEANT Monte Carlo (MC) code. The corresponding phase space (PS) data enabled the characterization of 12 sources representing the main components of the beam defining system. By parametrizing the source characteristics and by evaluating the dependence of the parameters on field size, it was possible to extend the validity of the model to arbitrary rectangular fields which include the central 3 x 3 cm2 field without additional precalculated PS data. Finally, a sampling procedure was developed in order to reproduce the PS data. To validate the MSM, the fluence, energy fluence and mean energy distributions determined from the original and the reproduced PS data were compared and showed very good agreement. In addition, the MC calculated primary energy spectrum was verified by an energy spectrum derived from transmission measurements. Comparisons of MC calculated depth dose curves and profiles, using original and PS data reproduced by the MSM, agree within 1% and 1 mm. Deviations from measured dose distributions are within 1.5% and 1 mm. However, the real beam leads to some larger deviations outside the geometrical beam area for large fields. Calculated output factors in 10 cm water depth agree within 1.5% with experimentally determined data. In conclusion, the MSM produces accurate PS data for MC photon dose calculations for the rectangular fields specified.

Algorithms↗

High-resolution three-dimensional-pQCT images can be an adequate basis for in-vivo microFE analysis of bone.

Micro-finite element (microFE) models based on high-resolution images have enabled the calculation of elastic properties of trabecular bone in vitro. Recently, techniques have been developed to image trabecular bone structure in vivo, albeit at a lesser resolution. The present work studies the usefulness of such in-vivo images for microFE analyses, by comparing their microFE results to those of models based on high-resolution micro-CT (microCT) images. Fifteen specimens obtained from human femoral heads were imaged first with a 3D-pQCT scanner at 165 microns resolution and a second time with a microCT scanner at 56 microns resolution. A third set of images with a resolution of 165 microns was created by downscaling the microCT measurements. The microFE models were created directly from these images. Orthotropic elastic properties and the average tissue von Mises stress of the specimens were calculated from six FE-analyses per specimen. The results of the 165 microns models were compared to those of the 56 microns model, which was taken as the reference model. The results calculated from the pQCT-based models, correlated excellent with those calculated from the reference model for both moduli (R2 > 0.95) and for the average tissue von Mises stress (R2 > 0.83). Results calculated from the downscaled micro-CT models correlated even better with those of the reference models (R2 > 0.99 for the moduli and R2 > 0.96 for the average von Mises stress). In the case of the 3D-pQCT based models, however, the slopes of the regression lines were less than one and had to be corrected. The prediction of the Poisson's ratios was less accurate (R2 > 0.45 and R2 > 0.67) for the models based on 3D-pQCT and downscaled microCT images respectively). The fact that the results from the downscaled and original microCT images were nearly identical indicates that the need for a correction in the case of the 3D-pQCT measurements was not due to the voxel size of the images but due to a higher noise level and a lower contrast in these images, in combination with the application of a filtering procedure at 165 micron images. In summary: the results of microFE models based on in-vivo images of the 3D-pQCT can closely resemble those obtained from microFE models based on higher resolution microCT system.

Adult↗

Computer algebra for x-ray spectral reconstruction between 6 and 25 MV.

A previously presented algorithm for the reconstruction of bremsstrahlung spectra from transmission data has been implemented into MATHEMATICA. Spectra vectorial algebra has been used to solve the matrix system A * F = T. The new implementation has been tested by reconstructing photon spectra from transmission data acquired in narrow beam conditions, for nominal energies of 6, 15, and 25 MV. The results were in excellent agreement with the original calculations. Our implementation has the advantage to be based on a well-tested mathematical kernel. Furthermore it offers a comfortable user interface.

Models, Theoretical↗

Quantitative ultrasound and trabecular architecture in the human calcaneus.

Relationships between quantitative ultrasound (QUS), density (bone volume density [BV/TV]), and trabecular architecture were investigated in 69 calcaneal cancellous bone cubes. Ultrasound signal velocity, phase velocity, attenuation, and broadband ultrasonic attenuation (BUA) measurements were made along the mediolateral axis. Density and architectural parameters were measured using microcomputed tomography (microCT). Density yielded the best correlations with QUS (r2 = 73-77%). Of the individual architectural parameters, correlations with QUS were highest for the Structure Model Index (SMI), a parameter quantifying the relative proportion of rods and plates (r2 = 57-63%). After adjustment for density, significant associations with QUS remained for SMI, trabecular spacing (Tb.Sp), and trabecular number (Tb.N), although the variance in QUS attributable uniquely to individual architectural parameters was at best 4%. In multivariate regression models, combinations of density and architectural parameters explained 76-82% of the variance in QUS, representing an r2 increase of, at most, 8% compared with using density alone. However, multivariate models using combinations of architectural parameters alone (i.e., density excluded) also had a good predictive ability for QUS (r2 = 73-81%). Thus, although these data show modest but significant density-independent relationships between QUS and trabecular architecture in the human calcaneus for the first time, the causal relationships behind the variation in acoustic properties remain obscure. Given the relative weakness and complexity of the emerging associations between QUS and architecture, it is prudent to regard QUS measurements in calcaneal bone primarily as an indicator of bone density.

Adult↗

Theoretical considerations to the verification of dynamic multileaf collimated fields with a SLIC-type portal image detector.

The verification possibilities of dynamically collimated treatment beams with a scanning liquid ionization chamber electronic portal image device (SLIC-EPID) are investigated. The ion concentration in the liquid of a SLIC-EPID and therefore the read-out signal is determined by two parameters of a differential equation describing the creation and recombination of the ions. Due to the form of this equation, the portal image detector describes a nonlinear dynamic system with memory. In this work, the parameters of the differential equation were experimentally determined for the particular chamber in use and for an incident open 6 MV photon beam. The mathematical description of the ion concentration was then used to predict portal images of intensity-modulated photon beams produced by a dynamic delivery technique, the sliding window approach. Due to the nature of the differential equation, a mathematical condition for 'reliable leaf motion verification' in the sliding window technique can be formulated. It is shown that the time constants for both formation and decay of the equilibrium concentration in the chamber is in the order of seconds. In order to guarantee reliable leaf motion verification, these time constants impose a constraint on the rapidity of the image-read out for a given maximum leaf speed. For a leaf speed of 2 cm s(-1), a minimum image acquisition frequency of about 2 Hz is required. Current SLIC-EPID systems are usually too slow since they need about a second to acquire a portal image. However, if the condition is fulfilled, the memory property of the system can be used to reconstruct the leaf motion. It is shown that a simple edge detecting algorithm can be employed to determine the leaf positions. The method is also very robust against image noise.

Computer Simulation↗

Simple beam models for Monte Carlo photon beam dose calculations in radiotherapy.

Monte Carlo (code GEANT) produced 6 and 15 MV phase space (PS) data were used to define several simple photon beam models. For creating the PS data the energy of starting electrons hitting the target was tuned to get correct depth dose data compared to measurements. The modeling process used the full PS information within the geometrical boundaries of the beam including all scattered radiation of the accelerator head. Scattered radiation outside the boundaries was neglected. Photons and electrons were assumed to be radiated from point sources. Four different models were investigated which involved different ways to determine the energies and locations of beam particles in the output plane. Depth dose curves, profiles, and relative output factors were calculated with these models for six field sizes from 5x5 to 40x40cm2 and compared to measurements. Model 1 uses a photon energy spectrum independent of location in the PS plane and a constant photon fluence in this plane. Model 2 takes into account the spatial particle fluence distribution in the PS plane. A constant fluence is used again in model 3, but the photon energy spectrum depends upon the off axis position. Model 4, finally uses the spatial particle fluence distribution and off axis dependent photon energy spectra in the PS plane. Depth dose curves and profiles for field sizes up to 10x10cm2 were not model sensitive. Good agreement between measured and calculated depth dose curves and profiles for all field sizes was reached for model 4. However, increasing deviations were found for increasing field sizes for models 1-3. Large deviations resulted for the profiles of models 2 and 3. This is due to the fact that these models overestimate and underestimate the energy fluence at large off axis distances. Relative output factors consistent with measurements resulted only for model 4.

Electrons↗

Effect of one year treatment with inhaled fluticasone propionate or beclomethasone dipropionate on bone density and bone metabolism: a randomised parallel group study in adult asthmatic subjects.

BACKGROUND: There is some concern that prolonged treatment with high doses of inhaled corticosteroids may have a detrimental effect on bone mass. The aim of this one year study was to investigate the effects of low and high doses of fluticasone propionate (FP) (400 microg/day and 750 microg/day) and beclomethasone dipropionate (BDP) (800 microg/day and 1500 microg/day) on bone mass and metabolism. METHODS: This was a multicentre, double blind, parallel group study involving 69 mild to moderate asthmatic subjects who were randomised to treatment as follows: 22 to FP400, 21 to BDP800, 13 to FP750, and 13 to BDP1500. Their mean age was 39 years, 67% were men, and all the women were premenopausal. RESULTS: The results of peripheral quantitative computed tomographic (pQCT) measurements (primary variable) showed that, compared with baseline values, there was no loss of trabecular or integral (cortical and trabecular) bone in the distal radius or tibia in any of the patients over the 12 month study period. No consistent pattern emerged from the analysis of changes from baseline in markers of bone formation and resorption after six and 12 months of treatment. CONCLUSION: The results of this study provide reassuring prospective one year data showing that inhaled corticosteroids, in the range of doses used, had no adverse effects on bone mass and metabolism in this group of asthmatic patients.

Administration, Inhalation↗

Three-dimensional analysis of root canal geometry by high-resolution computed tomography.

A detailed understanding of the complexity of root canal systems is imperative to ensure successful root canal preparation. The aim of this study was to evaluate the potential and accuracy of a three-dimensional, non-destructive technique for detailing root canal geometry by means of high-resolution tomography. The anatomy of root canals in 12 extracted human maxillary molars was analyzed by means of a micro-computed tomography scanner (microCT, cubic resolution 34 microm). A special mounting device facilitated repeated precise repositioning of the teeth in the microCT. Surface areas and volumes of each canal were calculated by triangulation, and means were determined. Model-independent methods were used to evaluate the canals' diameters and configuration. The calculated and measured volumes and the areas of artificial root canals, produced by the drilling of precision holes into dentin disks, were well-correlated. Semi-automated repositioning of specimens resulted in near-perfect matching (< 1 voxel) when outer canal contours were assessed. Root canal geometry was accurately assessed by this innovative technique; therefore, variables and indices presented may serve as a basis for further analyses of root canal anatomy in experimental endodontology.

Algorithms↗