Search PubMed⌕ Search

Biomedical subjects

J C Hsu

Publications and source records attributed to J C Hsu.

At least 109 records · Page 6Linked to original sources

Aerobic and anaerobic microorganisms in tubercles of the Columbus, Ohio, water distribution system.

Aerobic and anaerobic microorganisms were enumerated in tubercles collected from sections of the water distribution pipeline in the Columbus, Ohio, metropolitan area. Coliform bacteria were not detected in the tubercles examined. Sulfate-reducing bacteria were detected in 80% of the samples. Nitrate-reducing heterotrophs were present in all samples. The results, including plate counts of aerobic heterotrophs, indicated variation in bacterial densities depending on the tubercle sample and fraction examined. The associations among the viable counts obtained by the different culture methods were analyzed statistically, using three methods (Pearson, Spearman, and Kendall).

Aerobiosis↗

Isolation of ioxynil degraders from soil-enrichment cultures.

A soil enrichment technique was used to isolate microorganisms which could degrade ioxynil (3,5-diiodo-4-hydroxybenzonitrile). Many isolates obtained were able to degrade ioxynil to various products. However, only a fungal isolate (Fusarium solani) and a Gram-negative bacterium (Klebsiella ozaenae) released 14CO2 from ring-labeled ioxynil. No appreciable degradation was detected in pure cultures without the addition of exogenous nutrients. Results indicated that the degradation of ioxynil to CO2 proceeded more slowly in pure culture. Ioxynil was degraded in pure culture at a faster rate by F. solani than by K. ozaenae. Analyses of radioactivity distribution in the cultures indicated that a sizable fraction of radioactivity was in the form of polar products. Several degradation products were detected in the ethyl acetate extracts by thin-layer chromatography and subsequent radioautography. Screening of pure cultures of ioxynil degraders revealed that most isolates degraded ioxynil to the same products which were extractable with ethyl acetate.

Biodegradation, Environmental↗

Degradation of ioxynil and bromoxynil as measured by a modified spectrophotometric method.

A modified spectrophotometric method was developed to estimate ioxynil and bromoxynil residues. The method when compared with a 14C-tracer method was less sensitive but allowed rapid and accurate estimation of the herbicides. A clay loam soil with high organic matter content, which degraded ioxynil completely to CO2, also degraded bromoxynil completely. Bromoxynil degradation proceeded at a faster rate than that of ioxynil. The half-life of degradation was estimated to be 7 days for bromoxynil and 9-10 days for ioxynil. However, soil microorganisms which degraded ioxynil either completely to CO2 or partially did not seem to completely degrade bromoxynil. Degradation products from bromoxynil were detected on thin-layer chromatograms of extracts from pure cultures containing an exogenous carbon source. Complete degradation of bromoxynil and ioxynil in soil could be due to the action of different microorganisms.

Bacteria↗

Studies of the Involvement of an Endogenous Rhythm in the Photoperiodic Response of Hyoscyamus niger.

An attempt was made to determine the involvement of an endogenous circadian rhythm in the flowering response of the long-day plant Hyoscyamus niger L. grown in a modified White's medium. Both variable-cycle-length and light interruption experiments were employed in this attempt. In the variable-cycle experiments, plants were subjected to light periods of 6, 12, or 18 hours followed by varying lengths of darkness. The total lengths of the cycles varied from 12 to 72 hours. In experiments utilizing a 6-hour photoperiod, a high level of flowering occurred in cycle lengths of 12, 36, and 60 hours. Flowering was suppressed in the 24-, 48-, and 72-hour cycles. When a 12-hour photoperiod was used the flowering response was low between 24 and 36 hours and flowering did not indicate a rhythmic response. When an 18-hour photoperiod was used, the flowering response was suppressed in the 36- and 60-hour cycles.Light-break experiments were conducted to study further the flowering response in Hyoscyamus. These experiments consisted of a 6-hour main photoperiod followed by varying lengths of darkness to make cycles of 24, 48, and 72 hours. At given intervals the dark period was interrupted by 2-hour light breaks. In a 24-hour cycle, flowering was promoted when a light break was given at either the twelfth or eighteenth hour of the cycle. In a 48-hour cycle, flowering was strongly promoted by light breaks given near the beginning or at the end of the dark period. In a 72-hour cycle, light breaks given at the eighteenth, forty-second, and sixty-sixth hour of the cycle stimulated flowering as compared with light breaks given at the thirtieth and fifty-fourth hour. These results are indicative of the involvement of an endogenous rhythm in the flowering response of Hyoscyamus niger.

Journal Article↗

Can cardiac catheterization accurately assess the severity of aortic stenosis? An in vitro pulsatile flow study.

An accurate hemodynamic assessment of aortic stenosis has important clinical implications. In clinical practice, cardiac catheterization is often used to assess the severity of aortic stenosis. However, in conducting catheterization, the precise position of the catheter tip is often not known or controlled. From the standpoint of hydrodynamics, the position of the catheter tip may affect pressure measurement due to the complicated flow fields distal to the valve. This fact is particularly true when the diagnosed valve is stenotic. The study was aimed to investigate how the position of the catheter tip in catheterizing aortic stenosis affects pressure measurement. The experiments were conducted in an in vitro pulse duplicator system. Laser flow visualization was used to examine the flow fields in the vicinity of varying degrees of aortic stenosis, and a pressure transducer with a side-hole catheter was used to measure pressures. Minimal variation in transvalvular pressure drop measured along the radial direction was observed for varying degrees of valvular aortic stenosis. This implies that, in catheterization, the placement of the catheter tip along the radial direction does not seem to affect pressure measurement. However, along the axial direction, pressure recovery was observed for all the cases studied. Therefore, within the region of pressure recovery, the position of the catheter tip may affect the pressure drop measurement. This may cause inaccuracy in assessing the severity of aortic stenosis. However, this concern may be overcome by pulling the catheter slightly further downstream, so that the position of the catheter tip is outside of the pressure recovery region.

Adult↗

CT and MRI findings in a child with constrictive pericarditis.

Constrictive pericarditis is rare in children. We report computed tomography (CT) and magnetic resonance imaging (MRI) findings in a 3-year-old girl. She had a swollen abdomen that increased in two months. CT and MRI showed a thickened pericardium (5.2 mm) without calcification. Both atria were enlarged and ventricles were relatively small. The engorged inferior vena cava had 2.8x the diameter of the descending aorta at the same level. Symptoms were dramatically improved after pericardiectomy. The histopathological features confirmed chronic pericarditis.

Child, Preschool↗

The evaluation of false negative mammography from malignant and benign breast lesions.

Preoperative mammograms from 395 breast cancers and 132 benign breast lesions were enrolled for this study. The false-negative (FN) rate for breast cancers from preoperative reading was 9.6% with 38 breast cancers missed on mammograms. The statistically significant differences occurred between true-positive (TP) and FN cancers for younger age (P<.025), smaller lesion size (P<.001), denser breast (P<.05), deep retroglandular location (P<.001). None of the FN cancers exhibited calcifications. The FN rate for mammography for benign breast lesions from preoperative reading was 18.9% with 25 lesions misdiagnosed. The statistically significant difference between benign TP and FN lesions occurred for central and subareolar location (P<.025). Exploration of possible factors and imaging features in FN mammograms can help reduce the FN rate for mammography.

Adult↗