Search PubMed⌕ Search

Biomedical subjects

E R Melhem

Publications and source records attributed to E R Melhem.

69 records · Page 4Linked to original sources

Improved tissue characterization in adrenoleukodystrophy using magnetization transfer imaging.

OBJECTIVE: We performed this study to evaluate the usefulness of magnetization transfer (MT) imaging techniques and magnetization transfer ratio (MTR) measurements in assessing patients with adrenoleukodystrophy (ALD). SUBJECTS AND METHODS: Twelve patients who encompassed the range of ALD phenotypes were evaluated prospectively with MR and MT imaging (including digital subtraction images). The MT images and spin-echo MR images were compared by two staff neuroradiologists and a staff neurologist for extent of disease, different zones of involvement, and the presence of enhancement. MTR measurements were obtained from affected and unaffected regions of the brain. RESULTS: Eight of the 12 patients exhibited gadolinium enhancement. In seven of these patients, the MT subtraction images showed two zones of abnormal signal within the affected white matter. Their MTR measurements were classified as zone 1 (mean MTR, 35%; SD, 6%) and zone 2 (mean MTR, 20%; SD, 6%). Three of the other patients showed a single zone of involvement corresponding to the affected white matter on the standard spin-echo MR images. Their MTR measurements were similar to that of zone 1. The remaining two patients had no demonstrable signal abnormalities on any of the images. We noted no difference in any of the 12 subjects in the extent of white matter involvement on any of the imaging techniques. The MTR measurements in the unaffected white matter (mean MTR, 46%; SD, 5%) approximated established MTRs in white matter of normal volunteers. CONCLUSION: MT imaging and MTR measurements are helpful clinical techniques that may improve the evaluation of patients with ALD, particularly in the proposed ability of these techniques to divide the affected white matter into different zones that correspond to specific pathologic areas. These techniques can help the understanding of pathogenetic mechanisms and the evaluation of therapies.

Adolescent↗

Cervical spondylosis: three-dimensional gradient-echo MR with magnetization transfer.

PURPOSE: To compare a three-dimensional Fourier transform (3DFT) gradient-echo pulse sequence with magnetization transfer at a short echo time against standard 3DFT gradient-echo technique in the evaluation of cervical spondylosis, specifically addressing the effects of motion and susceptibility artifacts on the dimensions of the neural foramina and contrast at the cerebrospinal fluid (CSF)-spinal cord interface. METHODS: Ten patients with clinically suspected cervical spondylosis were examined with axial MR imaging using both our standard 3DFT gradient-echo sequence and a 3DFT gradient-echo sequence with a short echo time plus magnetization transfer. Two neuroradiologists measured the transverse dimensions of 22 diseased neural foramina and graded the contrast at the CSF-spinal cord interface. RESULTS: Sixteen of 22 affected neural foramina were larger in the transverse dimension when the magnetization transfer technique was used than when the standard 3DFT gradient-echo sequence was used. In 9 of 10 patients superior contrast was seen at the CSF-spinal cord interface on images obtained with the magnetization transfer technique. CONCLUSIONS: In the cervical spine, 3DFT gradient-echo imaging with magnetization transfer improves contrast and sharpness of the CSF-spinal cord interface at short echo times. This results in less exaggeration of the neural foraminal stenosis as compared with that seen with standard 3DFT gradient-echo techniques owing to the diminished effects of motion and susceptibility artifacts.

Cerebrospinal Fluid↗

Optimal CT evaluation for functional endoscopic sinus surgery.

PURPOSE: To evaluate the optimal parameters for the CT examination of patients who are having functional endoscopic sinus surgery. METHODS: CT scanning was performed on two fresh cadaveric heads in the direct coronal plane, varying the section thickness, intersection gap, scanner gantry angle, and amperage. The nasal cavity and paranasal sinuses were examined independently in a blinded fashion by four staff neuroradiologists and a staff otolaryngologist with special attention to 10 anatomic landmarks within the ostiomeatal unit that are considered important for preoperative planning. A score of 0 (nonvisualization/incomplete visualization) or 1 (clear/complete visualization) was assigned to each of these 10 landmarks. Analysis of variance was used in which reader, subject, and side were simultaneously controlled by "blocking." Multiple comparison methods (ie, Bonferroni) were used to compare the different protocols. RESULTS: We found a significant reduction in the delineation, and therefore the perception, of the ostiomeatal unit structures when the section thickness was greater than 5mm, any intersection gap was used, and the gantry angle was greater than 10 degrees from the plane perpendicular to the hard palate. However, a reduction in the radiation exposure from 200 mA to 80 mA did not affect the display of the anatomic landmarks. CONCLUSION: We found the optimal screening CT protocol for the paranasal sinuses to be a section thickness of 3 mm, no intersection gap, and a section angle within 10 degrees from the plane perpendicular to the palate. Also, owing to inherent contrast between air, soft tissue, and bone in the paranasal sinuses, a reduction in the radiation exposure parameter to 80 mA did not affect image quality.

Endoscopes↗

Multislice T1-weighted hybrid RARE in CNS imaging: assessment of magnetization transfer effects and artifacts.

Using a T1-weighted hybrid rapid acquisition with relaxation enhancement (RARE) MR sequence that implements an echo-to-view mapping scheme termed "low-high profile order," we evaluated signal intensity changes in different brain tissues as a function of number of slices, interslice gap, and echo train length (ETL). We also measured phase-encode and frequency-encode noise as well as blurring artifacts along the phase-encode direction as a function of ETL. Off-resonance magnetization transfer effects were demonstrated to be responsible for signal intensities changes in white matter and gray matter when using multislice techniques. These effects are amplified by increasing the number of slices and ETL. Due to the nature of the implemented echo-to-view mapping scheme, no on-resonance magnetization transfer effects were observed from the intraslice echo train. Selective background (white matter and gray matter) suppression in multislice T1-weighted hybrid RARE, secondary to off-resonance magnetization transfer effects, may provide better contrast resolution of enhancing central nervous system (CNS) lesions at much shorter scan time as compared to conventional spin-echo T1-weighted sequences. This improvement in contrast resolution as a function of ETL may be limited by worsening phase-encode noise and blurring artifacts.

Artifacts↗

Black-blood MR angiography with GRASE: measurement of flow-induced signal attenuation.

We investigated the feasibility of performing black-blood MR angiography (MRA) with the gradient and spin-echo (GRASE) pulse sequence. Phantom experiments and human testing were conducted, and the results were compared with those of turbo spin-echo (TSE). We demonstrated that both techniques are able to produce signal suppression of flowing fluid to background level. With fewer radiofrequency (RF)-refocusing pulses, GRASE pulse sequences could serve as an alternative black-blood technique of reduced RF power exposure and shorter scan time. These relative advantages of GRASE may become useful when high-resolution images are taken.

Blood Flow Velocity↗

Contrast-enhanced MR angiography: the effects of k-space truncation on luminal representation in a carotid artery phantom model.

Using carotid bifurcation phantom models with different degrees of stenoses, we evaluated the accuracy of vessel lumen representation on MR images obtained from the inverse Fourier transform of different k-space percentages. Our results show that the lower thresholds of truncated k-space sampling are dictated by the severity of luminal narrowing. The defined thresholds may help improve efficiency of 3D MR imaging of the carotid arteries while maintaining adequate luminal representation.

Carotid Arteries↗

A heterotopic cerebellum presenting as a suprasellar mass with associated nasopharyngeal teratoma.

We present a case of nasopharyngeal teratoma that was discovered in association with a suprasellar heterotopic cerebellum in a newborn. Well-differentiated, heterotopic, cerebellar masses have been reported in the orbits, spine, and frontal encephalocele but not, to our knowledge, in the suprasellar region. In this report, we describe the imaging findings and discuss the possible origins of the two masses discovered in this case.

Adult↗

Diffusion tensor MR imaging of the brain: effect of diffusion weighting on trace and anisotropy measurements.

BACKGROUND AND PURPOSE: In human brain, the relationship between MR signal and b value is complicated by cerebral perfusion, restricted diffusion, anisotropy, cellular membrane permeability, and active cellular transport of water molecules. Our purpose was to evaluate the effect of the number and strength of diffusion-sensitizing gradients on measured isotropic apparent diffusion coefficients (ADCi), fractional anisotropy (FA), and their respective SD in different anatomic locations of the brain. METHODS: Quantitative apparent diffusion coefficients and diffusion anisotropy brain maps were obtained from 10 healthy volunteers by using six different levels of diffusion weighting (b0 = 0, bl = 160, b2 = 320, b3 = 480, b4 = 640, and b5 = 800 s/mm2), applied sequentially in six different directions (Gxx, Gyy, Gzz, Gxy, Gxz, Gyz) and coupled to a single-shot spin-echo echo-planar (2,045/115 [TR/TE]) MR imaging technique. ADCi, FA, eigenvalues (lambda1, lambda2, lamdba3)1 of the principal eigenvectors, and their respective SD were measured from seven different anatomic locations in the brain. Repeated measures analysis of variance was used to evaluate for the existence of significant differences in the average and SD of the calculated ADCi and FA as a function of the number and strength of b values. When a difference existed, the Bonferroni t method was used for paired comparisons of the groups. RESULTS: The measured ADCi was affected by the number and strength of b values (P < .05). The SD of the ADCi was affected by the strength (P < .05) but not the number of b values (P > .05). The measured FA was unaffected by the number and strength of b values (P > .05). The SD was affected by the number and strength of b values (P < .05). CONCLUSION: The number and strength of b values do influence measures of diffusion and anisotropy. Attention to the choice of diffusion sensitization parameters is important in decisions regarding clinical feasibility (acquisition time) and normative measures.

Adult↗

Intramedullary spinal cord tuberculoma in a patient with AIDS.

Intramedullary spinal cord tuberculoma in a young, homosexual man with AIDS was detected with the use of MR and confirmed pathologically. MR findings were similar to those seen in other intramedullary lesions, eg, astrocytoma, ependymoma, hemangioblastoma, metastasis, lymphoma, and opportunistic infections. Delineation of the lesion improved with administration of Gd-DTPA; enhancement of the lesion, however, does not always correlate with true tumor margins at pathologic examination.

Acquired Immunodeficiency Syndrome↗

Diffusion tensor imaging in amyotrophic lateral sclerosis: volumetric analysis of the corticospinal tract.

BACKGROUND AND PURPOSE: Diffusion tensor imaging (DTI) allows direct visualization and volumetric analysis of the corticospinal tract (CST). The purpose of this study was to determine whether color maps and fiber tracking derived from DTI data are valuable in detecting and quantifying CST degeneration in patients with amyotrophic lateral sclerosis (ALS). METHODS: Sixteen patients with ALS with clinical signs of upper motor neuron (UMN) involvement and 17 healthy subjects were studied with the use of DTI. Disease severity was determined by means of the ALS Functional Rating Scale-Revised (ALSFRS-R) and an UMN involvement score. DTI was acquired with a 12-direction, single-shot, spin-echo echo-planar sequence. The CST from the lower pons to the corona radiata at the level of the corpus callosum on 4 contiguous coronal sections was manually segmented by using color maps generated from the DTI data. The left and right CST volumes were measured separately and normalized to the total intracranial volume. Normalized CST volumes were compared between patients with ALS and healthy subjects. RESULTS: The CST volumes of patients with ALS were significantly reduced (P < .01, unpaired t test) compared with healthy subjects, in both affected and nonaffected hemispheres. No significant correlation was found between CST volumes and any of the clinical parameters, including disease duration, ALSFRS-R, or UMN involvement score. CONCLUSION: This study shows that volumetric analysis by using DTI-based color maps is valuable in detecting and monitoring structural degeneration of the CST. This will lead to objective and quantitative assessment of axonal degeneration in ALS.

Adult↗

GRASE (gradient- and spin-echo) MR of the brain.

PURPOSE: To assess the clinical utility of GRASE (gradient- and spin-echo) MR imaging of the brain by comparing it with the T2-weighted turbo spin-echo technique. METHODS: Fifty-three consecutive patients referred for MR imaging of the brain were studied with T2-weighted turbo spin-echo and GRASE techniques, matched for effective echo time (110 milliseconds), echo train length (eight), and spatial resolution. The examinations were evaluated independently by two neuroradiologists for lesion detection (high- and low-signal-intensity lesions) and lesion conspicuity, and for susceptibility, motion, and chemical-shift artifacts. RESULTS: The GRASE technique provided greater detection of both high- and low-signal-intensity lesions and of low-signal-intensity lesions with paramagnetic susceptibility characteristics (ie, calcium and hemorrhage). Chemical-shift artifacts in the frequency-encoding direction were more prominent with the turbo spin-echo technique, whereas chemical-shift artifacts in the phase-encoding direction were more prominent with the GRASE technique. There was no significant difference in the degree of diamagnetic susceptibility artifacts at the base of the skull, or in motion artifacts. CONCLUSION: T2-weighted GRASE is a fast imaging technique with a potential for replacing turbo spin-echo in routine MR imaging of the brain. GRASE maintains the contrast resolution of turbo spin-echo imaging and is better at depicting lesions with paramagnetic susceptibility characteristics.

Aged↗

Inner ear volumetric measurements using high-resolution 3D T2-weighted fast spin-echo MR imaging: initial experience in healthy subjects.

BACKGROUND AND PURPOSE: Adult size is achieved in the inner ear labyrinth by approximately 25 weeks' gestation, and minimal variability in age, sex, side, and race is found after birth. In this study, we opted to determine the reproducibility of inner ear volumetric measurements generated from high-resolution heavily T2-weighted 3D fast spin-echo MR images. METHODS: The temporal bones of 23 volunteers were imaged using a heavily T2-weighted 3D fast spin-echo MR imaging technique. The images were assessed by a neuroradiologist for the presence of inner ear configurational anomalies and, most important, for complete coverage of the inner ear labyrinth. Subsequently, the volume of the fluid in the inner ear was determined by two observers using a semiautomated segmentation algorithm. The mean, SD, range, and coefficient of variation of fluid volume in the inner ear were calculated. Age-, sex-, and side-related differences in the inner ear volumetric measurements were evaluated using analysis of variance. Interrater consistency in the inner ear volumetric measurements was evaluated by comparing the calculated coefficients of reliability. RESULTS: Volumetric measurements were available from 46 inner ears in 23 volunteers. The mean volume was 227.8 mm3 (SD, 24.4 mm3), and the coefficient of variation was 10.7%. No age-, sex-, or side-related differences in the inner ear volumetric measurements were found (F ratios were 4.33, 5.04, and 0.26, respectively). Interrater consistency, as assessed by the coefficient of reliability, was 5.3%. CONCLUSION: Reproducible volumetric measurements of the inner ear labyrinth can be obtained by applying a semiautomated segmentation algorithm to a heavily T2-weighted 3D fast spin-echo MR imaging data set. These volumetric measurements may help identify patients with congenital sensorineural hearing loss and normal inner ear configuration.

Adult↗