Cervical spine: three-dimensional MR imaging with magnetization transfer prepulsed turbo field echo techniques.

In 11 volunteers, magnetic resonance (MR) imaging of the cervical spine was performed with a magnetization transfer preparatory pulse (prepulsed), three-dimensional Fourier transform, turbo field echo sequence. The effects of flip angle, number of shots, phase-encoding profile order, and magnetization transfer prepulse offset frequency on cerebrospinal fluid-to-cord contrast were evaluated. The contrast was improved by lowering the flip angle, increasing the number of shots, and implementing a magnetization transfer prepulse and linear phase-encoding profile order. Maximum myelographic effect was achieved with the magnetization prepulse (500-Hz frequency offset), 3 degrees flip angle, six shots, and linear phase-encoding profile order.

Adult↗

MR imaging of the hippocampus: measurement of T2 with four dual-echo techniques.

PURPOSE: To assess the effect of cerebrospinal fluid (CSF) signal nulling and different magnetic resonance (MR) imaging read-out implementations on the precision of T2 measurements in the hippocampus. MATERIALS AND METHODS: Oblique coronal MR imaging was performed in 12 healthy volunteers by using four dual-echo MR sequences: conventional spin-echo (SE), fast SE, gradient-echo and SE (GRASE), and fast fluid-attenuated inversion-recovery (FLAIR) imaging. T2 measurements were obtained from T2 maps derived from regions of interest within the head of both hippocampi. T2 measurements obtained with the four MR sequences were compared, as were differences in T2 between right and left hippocampi. Interrater and test-retest consistency were determined. RESULTS: Fast FLAIR imaging provided the smallest normal range and SD of T2 measurements. Fast FLAIR and fast SE imaging provided the smallest coefficients of variation. GRASE imaging provided a lower coefficient of variation than that of conventional SE. The mean difference between left and right hippocampi was smallest at fast FLAIR imaging. CONCLUSION: Use of a CSF-nulling inversion prepulse, fast SE read-out, or GRASE read-out MR sequence helps improve the precision of the hippocampal T2 measurements in comparison with use of conventional SE imaging. T2 measurements obtained at dual-echo fast FLAIR imaging may help detect subtle hippocampal abnormalities.

Adult↗

MR imaging of hemorrhagic brain lesions: a comparison of dual-echo gradient- and spin-echo and fast spin-echo techniques.

OBJECTIVE: Our objective was to assess the usefulness of the dual-echo gradient- and spin-echo (GRASE) technique in revealing acute hemorrhagic brain lesions and compare GRASE and fast spin-echo techniques for revealing acute hemorrhagic lesions and image artifacts. MATERIALS AND METHODS: Thirty-two consecutive patients with acute intracranial hemorrhage underwent dual-echo GRASE (TEeff1/TEeff2, 35/85) and fast spin-echo (25/110) imaging. The techniques were matched for TR (3032 msec), spatial resolution, and acquisition time. Two neuroradiologists reviewed the images independently, documenting the number, size (<1, >1, or 1 cm in diameter), location, and signal characteristics (hypointense versus hyperintense compared with brain) of detectable lesions. These observers also compared matched T2- and proton density-weighted GRASE and fast spin-echo images for paramagnetic lesion conspicuity, diamagnetic susceptibility artifacts, chemical shift artifacts along the phase- and frequency-encoding directions, and artifactual CSF hyperintensity in the thin curvilinear cortical sulci and the Virchow-Robin spaces on only the proton density-weighted images. RESULTS: The average number and conspicuity of dark (paramagnetic) lesions were significantly greater on GRASE than on fast spin-echo images (p < .05 and p < .001, respectively). We found no significant difference in the average number of bright lesions revealed by either technique (p > .1). Chemical shift artifacts along the phase-encoding directions were more prominent on GRASE than on fast spin-echo imaging. Chemical shift artifacts along the frequency-encoding directions and artifactual CSF hyperintensity were more prominent on fast spin-echo than on GRASE imaging. No visually apparent difference was found in the degree of diamagnetic susceptibility artifacts seen with the two techniques. CONCLUSION: Dual-echo GRASE imaging can be helpful in the examination of patients with suspected acute brain hemorrhage.

Adult↗

Usefulness of optimized gadolinium-enhanced fast fluid-attenuated inversion recovery MR imaging in revealing lesions of the brain.

OBJECTIVE: The purpose of this study was to compare the contrast enhancement of lesions of the brain revealed by gadolinium-enhanced optimized fast fluid-attenuated inversion recovery (FLAIR) MR imaging with that of lesions on gadolinium-enhanced optimized T1-weighted spin-echo MR imaging. SUBJECTS AND METHODS: Using computer simulations, we optimized the fast FLAIR parameters (TR, TEeff, and inversion time) and the T1-weighted spin-echo parameters (TR and TE) to provide maximum difference in signal intensity between enhancing lesions of the brain and white matter. Seventy-six consecutive patients referred for single-dose gadolinium-enhanced MR imaging of the brain underwent both optimized techniques, which were matched for spatial resolution, bandwidth, and number of excitations. The gadolinium-enhanced fast FLAIR and T -weighted spin-echo MR images were evaluated independently by two observers for number and size of enhancing lesions and for the degree of gray-white matter differentiation. Contrast-to-noise ratios were measured for enhancing lesions 1.0 cm or larger in diameter using 8 x 8 pixel regions of interest in the enhancing lesions and normal white matter. RESULTS: The most revealing parameters for fast FLAIR MR imaging proved to be a TR of 1500 msec, an inversion time of 683 msec, and a TEeff of 16 msec. For T1-weighted spin-echo MR imaging, the optimized parameters were a TR of 550 msec and a TE of 16 msec. In 28 patients, we saw enhancing lesions of the brain with at least one MR imaging technique. More lesions were seen on the T1-weighted spin-echo sequence (n = 141) than on the fast FLAIR sequence (n = 94) (p < .03). Gray-white matter differentiation was significantly better on the fast FLAIR sequence (p < .001). Contrast-to-noise ratios of enhancing lesions were greater on the T1-weighted spin-echo sequence (p < .001). CONCLUSION: In this study, optimized gadolinium-enhanced conventional T1-weighted spin-echo MR imaging proved superior to gadolinium-enhanced fast FLAIR MR imaging in revealing lesions of the brain.

Adult↗

Telangiectatic osteosarcoma of the skull base.

We present a patient with a distinctive lesion of the skull base, which, at imaging, showed expansile destruction of the sphenoid bone, hemorrhage with fluid-fluid levels, and contrast enhancement of a solid portion. These features ordinarily suggest either giant cell tumor or aneurysmal bone cyst; however, pathologic examination confirmed instead a rare variant of osteosarcoma of the telangiectatic type. Although imaging findings can indicate any of these possibilities, biopsy is an essential step in arriving at the diagnosis.

Humans↗

SPECT imaging in cerebral vasospasm following subarachnoid hemorrhage.

UNLABELLED: Cerebral vasospasm is a frequent complication after subarachnoid hemorrhage and contributes to overall morbidity and mortality. Arteriography is the standard test for determining the presence of vasospasm. A retrospective review of 16 patients with cerebral aneurysm was undertaken to assess the sensitivity and specificity of SPECT for diagnosis of vasospasm. Fourteen patients were hospitalized after subarachnoid hemorrhage and 2 patients were hospitalized for elective aneurysmal clipping. The patients' condition on discharge was correlated to clinical and SPECT evidence of vasospasm. METHODS: Vasospasm was defined as the new onset of neurological signs and symptoms not explained by rebleed or hydrocephalus. A total of 20 SPECT studies were performed for 16 patients during their admission and 14 of 16 patients had a single angiographic study. RESULTS: Thirteen of 16 patients had 14 episodes of clinical evidence of vasospasm and 14 SPECT studies were performed in these 13 patients. The sensitivity and specificity of SPECT in this retrospective study were 89% (8/9) and 71% (5/7), respectively. Our small sample of arteriograms yielded in comparison a sensitivity of 67% (2/3) and specificity of 100% (9/9). The one false-negative SPECT study occurred in conjunction with the one false-negative arteriogram in the presence of clinical findings consistent with vasospasm. Three false-positive SPECT studies occurred in 2 patients who had perfusion abnormalities in areas of normal CT findings without clinical or arteriographic evidence of vasospasm. Five of 5 patients who died became unresponsive as a result of clinically presumed vasospasm and 4 of 5 of these patients had diffuse or hemispheric SPECT perfusion defects. Of the 11 patients who survived, none became unresponsive; 1 of 11 had positive diffuse or hemispheric perfusion defects. CONCLUSION: SPECT is a sensitive and fairly specific test for corroboration of clinical findings of vasospasm. A negative SPECT study may obviate the need for arteriography. Unresponsiveness is the best predictor of poor outcome; however, hemispheric SPECT perfusion deficits are also associated with poor outcome.

Cerebral Angiography↗

Spontaneous labyrinthine hemorrhage in sickle cell disease.

We report the clinical and MR imaging findings in two African-American patients with manifestations of sickle cell disease affecting the inner ear. Both suffered sudden-onset sensorineural hearing loss and vestibular symptoms, and both had high labyrinthine signal on T1-weighted MR images attributed to labyrinthine hemorrhage. Follow-up studies of the first patient revealed a decrease in abnormal vestibular signal. Careful attention to the labyrinth on T1-weighted MR images can reveal vestibulocochlear clinical findings in sickle cell patients, with important implications for management and prognosis.

Adult↗

MR imaging of soft tissues adjacent to orthopaedic hardware: techniques to minimize susceptibility artefact.

This article demonstrates and compares imaging of orthopaedic hardware (fixation plates, screws, Kischner wire and prostheses) using gradient-echo, spin-echo and fast spin-echo sequences. It describes simple techniques which minimize susceptibility artefact induced by these components at magnetic resonance (MR) imaging, allowing visualization of adjacent soft tissues. The article emphasizes the importance of selecting the appropriate imaging plane in order to avoid hardware distortion of slice select gradients, emphasizes the importance of selecting frequency encoding gradient axes in order to orientate the long axis of the artefact away from the tissue of interest and, finally, compares the marked susceptibility artefact observed adjacent to hardware using gradient-echo with the artefact reduction achieved by using fast spin-echo sequences.

Artifacts↗

An approach to imaging the dizzy patient.

Disease of the vestibular system involves a lengthy differential diagnosis, from the relatively trivial to potentially life-threatening conditions. As a definitive specific diagnosis is often difficult to make, imaging may be used simply to "rule out" serious pathology. In this context, suboptimal imaging choices may be unnecessarily expensive and may fail to document the pathology. In contrast, an orderly investigation includes appropriate audiometric and vestibular tests, which when reviewed in the clinical context, indicate the most pertinent imaging modalities. This enables the clinician to plan a cost-effective, definitive imaging strategy. This review considers the role of imaging in an integrated approach to investigating the dizzy patient. A discussion of vestibular pathology is presented to assist in the review, and several cases are provided as examples.

Aged↗

Improved contrast of enhancing brain lesions using contrast-enhanced T1-weighted fast spin-echo MR imaging.

OBJECTIVE: The purpose of this study was to evaluate the ability of T1-weighted fast spin-echo MR sequences to provide improved contrast-to-noise ratios for contrast-enhanced lesions during acquisition times shorter than those used for conventional T1-weighted spin-echo MR sequences. SUBJECTS AND METHODS: We compared contrast-to-noise ratios of 32 enhancing brain lesions in 25 patients on T1-weighted spin-echo (546/10 [TR/TE]; two excitations; acquisition time, 4 min 12 sec) and on fast spin-echo (546/10 [TR/effective TE]; echo-train length, 4; echo spacing, 10 msec; two excitations; acquisition time, 1 min 45 sec) MR images obtained at 1.5 T after i.v. administration of 0.10 mmol/kg gadopentetate dimeglumine. RESULTS: The contrast-enhanced T1-weighted fast spin-echo MR images showed approximately a 12% reduction in the signal-to-noise ratios of the background white matter without an accompanying reduction in the signal-to-noise ratios of the enhancing lesions or CSF when compared with the contrast-enhanced T1-weighted spin-echo MR images. The contrast-enhanced T1-weighted fast spin-echo MR images provided a 23% improvement in the contrast-to-noise ratios of enhancing lesions over the contrast-enhanced T1-weighted spin-echo images (p < .001). CONCLUSION: Contrast-enhanced T1-weighted fast spin-echo MR imaging showed a statistically significant improvement in contrast-to-noise ratios at much shorter scan times than those used in conventional contrast-enhanced T1-weighted spin-echo MR imaging.

Adult↗

Fluid-attenuated inversion recovery MR imaging: identification of protein concentration thresholds for CSF hyperintensity.

OBJECTIVE: Using human volunteers and phantoms emulating CSF, we analyzed the effects of varying protein concentration on the signal intensity of saline solution. Also, for different fluid-attenuated inversion recovery (FLAIR) sequences, we compared protein concentration thresholds above which the signal from these solutions becomes hyperintense to that from brain parenchyma. SUBJECTS AND METHODS: Nine albumin solutions of varying concentrations (3.9 mg/dl to 2500 mg/dl) were imaged using fast FLAIR MR sequences (TR, 6000 msec: inversion time, 1730 msec: echo train length, 20) at different effective TEs (110, 150, 200, and 250 signal-to-noise ratios from the different albumin solutions versus albumin concentration were generated and correlated with average signal-to-noise ratios from brain parenchyma and CSF. RESULTS: We saw a gradual increase in signal-to-noise ratios from the albumin solutions as a function of albumin concentration. As the effective TE increased, the point of intersection between the plots and the average signal-to-noise ratio from brain parenchyma occurred at lower albumin concentrations. CONCLUSION: FLAIR MR imaging is potentially useful to evaluate pathologic conditions that increase CSF protein concentration. Using phantoms and healthy volunteers, we defined a protein concentration threshold above which the signal from saline solutions becomes hyperintense to that from brain parenchyma. This threshold depends on the effective TE used in the FLAIR sequence and is 250 mg/dl for an effective TE of 110 msec, 125 mg/dl for 150 msec. 110 mg/dl for 200 msec, and 95 mg/dl for 250 msec.

Adult↗

A comparison of whole-body turboSTIR MR imaging and planar 99mTc-methylene diphosphonate scintigraphy in the examination of patients with suspected skeletal metastases.

OBJECTIVE: This study was undertaken to compare whole-body turbo short inversion time inversion recovery MR imaging and 99mTc-methylene diphosphonate planar scintigraphy in the examination of patients with suspected skeletal metastases. SUBJECTS AND METHODS: Twenty-five patients with known or suspected skeletal metastatic disease underwent both whole-body turbo short inversion time inversion recovery MR imaging and whole-body 99mTc-methylene diphosphonate scintigraphy. RESULTS: MR imaging revealed metastases at 57 of 175 possible sites (sensitivity, 96.5%, specificity, 100%; positive predictive value, 100%). Scintigraphy revealed metastases at 43 of 175 possible sites (sensitivity, 72%; specificity, 98%; positive predictive value, 95%) (McNemar test, 0.01; p = .016). Discrepancies in skeletal evaluation by whole-body MR imaging and scintigraphy were observed in six (24%) of 25 patients. Soft-tissue abnormalities were identified in 13 (52%) of 25 patients with MR imaging alone. CONCLUSION: Preliminary results suggest that whole-body MR imaging is an effective method of examining patients with suspected skeletal metastases, with better sensitivity than conventional planar 99mTc-methylene diphosphonate scintigraphy.

Adult↗

MR of the spine with a fast T1-weighted fluid-attenuated inversion recovery sequence.

PURPOSE: To optimize a T1-weighted fast fluid-attenuated inversion recovery (FLAIR) sequence using computer-simulated data and to study its clinical utility for imaging the spine. METHODS: Relative signal intensities and contrast of relevant normal and pathologic tissues in the spine were computed using an inversion recovery equation modified to account for a hybrid RARE (rapid acquisition with relaxation enhancement) readout. A range of inversion time (TI) and repetition time (TR) pairs that null the signal from CSF was generated. A contrast-optimized heavily T1-weighted fast FLAIR sequence, based on the generated data, was qualitatively compared with conventional T1-weighted spin-echo sequences for imaging various spinal abnormalities. RESULTS: A T1/TR pair of approximately 862/2000 was extracted from the computer-generated data to produce effective nulling of CSF signal, to achieve heavy T1 weighting, and to optimize contrast between abnormal tissues and cord/bone marrow. Clinical implementation of the optimized T1-weighted fast FLAIR sequence revealed superior contrast at the CSF-cord interface, better conspicuity of lesions of the spinal cord and bone marrow, and reduced hardware-related artifacts as compared with conventional T1-weighted spin-echo sequences. CONCLUSION: The optimized T1-weighted fast FLAIR technique has definite advantages over spin-echo sequences for imaging the spine. Comparable acquisition times render the FLAIR sequence the method of choice for T1-weighted imaging of the spine.

Adult↗

Fast inversion-recovery MR: the effect of hybrid RARE readout on the null points of fat and cerebrospinal fluid.

PURPOSE: To evaluate the effect of the hybrid RARE (rapid acquisition with relaxation enhancement) readout, commonly coupled to inversion-recovery pulse sequences, on the null inversiton time (TI) of fluid and fat using both phantoms and human volunteers. METHODS: Two phantoms, simulating fat (phantom A) and cerebrospinal fluid (phantom B), respectively, were imaged using a fast inversion-recovery sequence that coupled an inversion-recovery preparation pulse to a hybrid RARE readout. At repetition times (TRs) ranging from 700 to 20,000, the TI necessary to null the signal from each phantom (null TI) was determined for an echo train length of 4, 6, 8, 10, 12, 14, 16, 18, and 20, respectively. Plots of null TI versus echo train length at different TRs were generated for both phantoms. Fast inversion-recovery MR imaging of the cervical spine and brain was performed in healthy volunteers. At a fixed TR and TI, the adequacy of signal suppression from bone marrow and cerebrospinal fluid was assessed as a function of echo train length. RESULTS: There was a gradual decrease of null TI for both phantoms with echo train length. This decrease persisted at longer TRs for phantom B (T1 = 3175 +/- 70 milliseconds) than for phantom A (T1 = 218 +/- 5 milliseconds). In the human volunteers, there was a gradual loss of suppression of signal from bone marrow and cerebrospinal fluid, with changes in the hybrid RARE readout. CONCLUSION: To optimize specific tissue suppression, radiologists implementing fast inversion-recovery MR imaging should be aware of the effects of the hybrid RARE readout on null TI.

Adipose Tissue↗