Search PubMed⌕ Search

PubMed · 8770274

Optimal CT evaluation for functional endoscopic sinus surgery.

Abstract

PURPOSE: To evaluate the optimal parameters for the CT examination of patients who are having functional endoscopic sinus surgery. METHODS: CT scanning was performed on two fresh cadaveric heads in the direct coronal plane, varying the section thickness, intersection gap, scanner gantry angle, and amperage. The nasal cavity and paranasal sinuses were examined independently in a blinded fashion by four staff neuroradiologists and a staff otolaryngologist with special attention to 10 anatomic landmarks within the ostiomeatal unit that are considered important for preoperative planning. A score of 0 (nonvisualization/incomplete visualization) or 1 (clear/complete visualization) was assigned to each of these 10 landmarks. Analysis of variance was used in which reader, subject, and side were simultaneously controlled by "blocking." Multiple comparison methods (ie, Bonferroni) were used to compare the different protocols. RESULTS: We found a significant reduction in the delineation, and therefore the perception, of the ostiomeatal unit structures when the section thickness was greater than 5mm, any intersection gap was used, and the gantry angle was greater than 10 degrees from the plane perpendicular to the hard palate. However, a reduction in the radiation exposure from 200 mA to 80 mA did not affect the display of the anatomic landmarks. CONCLUSION: We found the optimal screening CT protocol for the paranasal sinuses to be a section thickness of 3 mm, no intersection gap, and a section angle within 10 degrees from the plane perpendicular to the palate. Also, owing to inherent contrast between air, soft tissue, and bone in the paranasal sinuses, a reduction in the radiation exposure parameter to 80 mA did not affect image quality.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E R Melhem, P J Oliverio, M L Benson, D A Leopold, S J Zinreich. 1996. Optimal CT evaluation for functional endoscopic sinus surgery.. https://pubmed.ncbi.nlm.nih.gov/8770274/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Endoscopic controlled intramedullary fracture reduction. A case report about closed fracture reduction under visual control.

Intramedullary bone endoscopy (IBE) was introduced as a new endoscopic technique in the year 2002 to achieve and manipulate the medullary canal of long bone under direct visual control. We report on a patient with a proximal femur fracture, where the new technique of IBE was used for intramedullary fracture reduction under visual control for the first time. Thus, the intraoperative use of an image intensifier was reduced.

Endoscopes↗

Removal of a pellet from the left orbital cavity by image-guided endoscopic navigation.

In the cranio-maxillofacial field, computer-aided surgery based on computed tomography data is becoming increasingly important. Complex surgical procedures can be performed utilizing preoperative imaging to provide real-time localization of surgical instruments in the surgical field. Image-data-based navigation plays an ever-increasing role in cases of minimal invasive surgery. The case is presented here of a 58-year-old male patient referred after a hunting accident with a pellet in the left orbit. After transferring the preoperatively acquired computed tomography data to a commercially available navigation system, the bullet was removed through the original wound canal using an intraoperatively calibrated high-resolution endoscope.

Endoscopes↗

[Manipulator assisted endoscope guidance in functional endoscopic sinus surgery: proof of concept].

BACKGROUND: Functional endoscopic sinus surgery (FESS) is characterized by single-handed preparation and guidance of the endoscope by the nondominant hand. This results in an additional extension of operation time by up to 15% and ergonomic deficits. The aim of this study is the conception of an automated assistance system for FESS in view of the following questions: (1) Which degree of surgical automation is suitable for FESS? (2) Which design is suitable? (3) What are the properties of the technical system (planning, time, accuracy, precision) of the selected system? (4) Does the system offer potential for a clinical application? METHODS: In all 49 FESS were analyzed for surgical workflows. Measurement of the maximum forces within FESS was performed with 40 trials on an anatomical model. Three different mechanical systems were used in ten FESS and evaluated using the ICCAS Human-Machine Evaluation Scale. For realization of automated endoscope guidance an engine-driven and -braked manipulator (PA10-6c, Mitsubishi, Japan) was used. The technical parameters determined were expenditure of time for the preoperative planning of workspace, surgical accuracy and precision of the intraoperative endoscope positioning, maximal forces, and time. RESULTS: Concept-conditioned instrument changes amount to an average of 41.1 and 18.9% (5.21 min) time requirement for each FESS side. Maximum forces on the mucous membrane during a conventional FESS were measured at 9.8 N (5.9-9.8). Usability of the mechanical endoscope holder was estimated in 18 of 20 cases to be inferior to the standard procedure. The time needed for segmenting the intranasal workspace was 15.2 min (10.0-23.0). The maximum deviation of the automatically driven endoscope from a planned position amounted to 0.85 mm (manually 4.64 mm). The maximum force was measured with 1.1 N in the z direction (manually 9.8 N). Automated guidance of the endoscope to an intranasal position needed 7.25 s (6.4-7.9); manually 12.64 s (5.9-43.0). CONCLUSION: Guidance of the endoscope for FESS by an automated motor-driven system is possible. The conception which is based on workflow analysis favors a system with automatic definition of the workspace and a manual movement of the endoscope. The examined system offers a potential for clinical application. Definition of the automation level and development of a man-machine interface is more important than selection or reconstruction of a special manipulator for endoscope guidance in FESS from a surgical point of view.

Endoscopes↗