Search PubMed⌕ Search

Biomedical subjects

C T Wittwer

Publications and source records attributed to C T Wittwer.

At least 37 records · Page 2Linked to original sources

Quantification of low-copy transcripts by continuous SYBR Green I monitoring during amplification.

Continuous fluorescence observation of amplifying DNA allows rapid and accurate quantification of initial transcript copy number. A simple and generic method for monitoring product synthesis with the double-stranded DNA dye, SYBR Green I provides initial template copy number estimation limited only by stochastic effects. To reach this degree of sensitivity, two methods were used. First, specific products generally have a higher melting temperature than nonspecific products, and therefore, specific product formation was monitored by fluorescence acquisition at temperatures at which only specific products are double-stranded. Second, anti-Taq antibodies were used to reduce nonspecific product generation. The log-linear portion of the fluorescence vs. cycle plot was extended to determine a fractional cycle number at which a threshold fluorescence was obtained. These fractional cycle numbers were plotted against the log of starting template copies to give linear standard curves from purified PCR products, allowing easy estimation of cDNA unknowns over a 10(6)-fold range. A single template molecule per reaction could be distinguished from the absence of template, although stochastic effects increased the variance of concentration estimates below 10 copies. Above 10 copies per reaction, typical replicate coefficients of variation were 6%-37%, with better precision at higher copy numbers.

Animals↗

Fully automated DNA reaction and analysis in a fluidic capillary instrument.

A simple, reliable, automated genetic analysis instrument has been designed and prototyped. The system uses novel fluidic technology, coupling thermal cycling, reaction purification, in-line loading, and capillary electrophoresis in a single instrument. Samples in the loop of an injection valve are amplified inside a rapid air thermal cycler. A liquid chromatographic separation eliminates contaminants and excess salt. The sample is loaded in an efficient, continuous, flow-through manner onto a polymer-filled separation capillary. Detection by laser-induced fluorescence produces signal-to-noise ratios of 1000:1 or greater. Refilling of the polymer-filled capillary is automatic; during the run, the system is reconditioned for injection of another sample. Since all components and connections are fluidic, automation is natural and simple. The instrument is reliable and fast, performing PCR reaction cycling, purification and analysis, all in 20 min. Reproducibility (CV) of retention times is 2% (n = 129) and of peak areas 9% (n = 34). Bubbles and particulates are eliminated by the chromatography column. Adaptation of the instrument prototype for separation of DNA-sequencing reactions is described; cycle sequencing and electrophoresis of a single lane are complete in 90 min. Implications and challenges for development of fully automated fluidic instruments for genomic sequencing are discussed.

Chromatography, High Pressure Liquid↗

Product differentiation by analysis of DNA melting curves during the polymerase chain reaction.

A microvolume fluorometer integrated with a thermal cycler was used to acquire DNA melting curves during polymerase chain reaction by fluorescence monitoring of the double-stranded DNA specific dye SYBR Green I. Plotting fluorescence as a function of temperature as the thermal cycler heats through the dissociation temperature of the product gives a DNA melting curve. The shape and position of this DNA melting curve are functions of the GC/AT ratio, length, and sequence and can be used to differentiate amplification products separated by less than 2 degrees C in melting temperature. Desired products can be distinguished from undesirable products, in many cases eliminating the need for gel electrophoresis. Analysis of melting curves can extend the dynamic range of initial template quantification when amplification is monitored with double-stranded DNA specific dyes. Complete amplification and analysis of products can be performed in less than 15 min.

Benzothiazoles↗

Detection of Epstein-Barr viral DNA in serum using rapid-cycle PCR.

Our study describes the comparison of a rapid nested PCR assay to standard serology techniques for the detection of Epstein-Barr virus (EBV) in serum. The sera of 81 patients with suspected EBV infection were analyzed; 54 were positive for one or more of the standard serology markers, i.e., IgM viral capsid antigen (VCA), IgG-VCA, Epstein-Barr nuclear antigen 1 (EBNA-1), and early antigen (EA), and 27 were negative for all serology markers. The sera from 15 normal healthy blood donors were also included. No EBV DNA was detected in any of the 15 blood donor samples or in any of the 27 samples with negative serology results. Eleven samples (20%) of the 54 with positive EBV serology results were positive for EBV DNA. Of these samples, 9 were EBV IgM-VCA positive and anti-EBNA negative, suggesting acute infection. One of the 11 samples had high titers of IgM-VCA, IgG-VCA, anti-EBNA, and anti-EA. The last of the 11 samples was from a patient with acute infectious mononucleosis without sufficient sample volume for EBV serology testing. Seventeen of the total 96 samples from the study were IgM-VCA positive and anti-EBNA negative and 9 of these 17 samples (53%) tested positive for EBV DNA. These data suggest that the detection of EBV DNA by PCR in serum may be a useful indicator of active infection rather than latent virus.

Antibodies, Viral↗

Continuous fluorescence monitoring of rapid cycle DNA amplification.

Rapid cycle DNA amplification was continuously monitored by three different fluorescence techniques. Fluorescence was monitored by (i) the double-strand-specific dye SYBR Green I, (ii) a decrease in fluorescein quenching by rhodamine after exonuclease cleavage of a dual-labeled hydrolysis probe and (iii) resonance energy transfer of fluorescein to Cy5 by adjacent hybridization probes. Fluorescence data acquired once per cycle provides rapid absolute quantification of initial template copy number. The sensitivity of SYBR Green I detection is limited by nonspecific product formation. Use of a single exonuclease hydrolysis probe or two adjacent hybridization probes offers increasing levels of specificity. In contrast to fluorescence measurement once per cycle, continuous monitoring throughout each cycle monitors the temperature dependence of fluorescence. The cumulative, irreversible signal of hydrolysis probes can be distinguished easily from the temperature-dependent, reversible signal of hybridization probes. By using SYBR Green I, product denaturation, annealing and extension can be followed within each cycle. Substantial product-to-product annealing occurs during later amplification cycles, suggesting that product annealing is a major cause of the plateau effect. Continuous within-cycle monitoring allows rapid optimization of amplification conditions and should be particularly useful in developing new, standardized clinical assays.

Benzothiazoles↗

The LightCycler: a microvolume multisample fluorimeter with rapid temperature control.

Experimental and commercial microvolume fluorimeters with rapid temperature control are described. Fluorescence optics adopted from flow cytometry were used to interrogate 1-10-microL samples in glass capillaries. Homogeneous temperature control and rapid change of sample temperatures (10 degrees C/s) were obtained by a circulating air vortex. A prototype 2-color, 32-sample version was constructed with a xenon arc for excitation, separate excitation and emission paths, and photomultiplier tubes for detection. The commercial LightCycler, a 3-color, 24-sample instrument, uses a blue light-emitting diode for excitation, paraxial epi-illumination through the capillary tip and photodiodes for detection. Applications include analyte quantification and nucleic acid melting curves with fluorescent dyes, enzyme assays with fluorescent substrates and techniques that use fluorescence resonance energy transfer. Microvolume capability allows analysis of very small or expensive samples. As an example of one application, rapid cycle DNA amplification was continuously monitored by three different fluorescence techniques, Which included using the double-stranded DNA dye SYBR Green I, a dual-labeled 5'-exonuclease hydrolysis probe, and adjacent fluorescein and Cy5z-labeled hybridization probes. Complete amplification and analysis requires only 10-15 min.

Benzothiazoles↗

Real-time fluorescence genotyping of factor V Leiden during rapid-cycle PCR.

A single-step method for factor V Leiden genotyping is presented that uses rapid-cycle PCR and simultaneous fluorescence analysis with resonance energy transfer probes. A fragment of the factor V gene containing the mutation is amplified asymmetrically through use of a primer labeled with Cy5 in the presence of a 3'-fluorescein-labeled probe that covers the mutation site. When the fluorescein probe is annealed to the extension product of the Cy5-labeled primer, the fluorophores are brought into close enough contact for resonance energy transfer to occur. As the temperature increases, the probe melts from its target, decreasing the resonance energy transfer. When the probe is complementary to the product strand, it melts at 65 degrees C; if the single-base mutation is present, the probe melts at 57 degrees C. Concurrent amplification and analysis from genomic DNA takes 20-45 min and requires no sample manipulation after the fluorescence thermal cycler is loaded.

Base Sequence↗

Syngeneic bone marrow transplantation without conditioning in a patient with paroxysmal nocturnal hemoglobinuria: in vivo evidence that the mutant stem cells have a survival advantage.

A 10-year-old girl with paroxysmal nocturnal hemoglobinuria (PNH) received an infusion of syngeneic bone marrow without preparative marrow ablation or immunosuppression. Following transplant, the patient became asymptomatic in concordance with an increase in the percentage of peripheral blood cells with normal expression of glycosyl phosphatidylinositol-anchored proteins (GPI-AP). However, molecular analysis suggested engraftment of a relatively small number of donor stem cells and persistence of an abnormal stem cell with mutant PIG-A. During 17 months of observation, the percentage of cells with normal GPI-AP expression gradually decreased, while intravascular hemolysis progressively increased. Approximately 16.5 months post-transplant, the patient once again became symptomatic. Together, these results indicate that syngeneic marrow infusion provided a clinical benefit by increasing the proportion of erythrocytes with normal expression of GPI-anchored complement regulatory proteins without supplanting the abnormal stem cells. However, evidence of insidious disease progression following the marrow infusion implies that the abnormal stem cells have a survival advantage relative to the transplanted stem cells. Thus, these studies contribute in vivo data in support of the hypothesis that PNH arises as a consequence of a pathological process that selects for hematopoietic stem cells that are GPI-AP-deficient.

Bone Marrow Transplantation↗

Aprosencephaly and cerebellar dysgenesis in sibs.

Aprosencephaly is a rare, lethal malformation sequence of the central nervous system that has been attributed to a postneuralation encephaloclastic process. We describe autopsy findings consistent with aprosencephaly in 2 fetuses conceived from a consanguineous mating (first cousins). Both showed anencephalic manifestations; however, the crania were intact, with fused sutures. The neuropathologic findings were essentially identical. Each fetus had complete absence of the telecephalon and pyramidal tracts, rudimentary diencephalic and mesencephalic structures, primitive cerebellar hemispheres, posterolateral clusters of primitive neural cells in the medullas suggesting an abnormality of neural migration, a normally-formed spinal cord, and retinal dysplasia within normally-formed globes. In addition, both fetuses manifested a peculiar perivascular mesenchymal proliferation seen only within the central nervous system. The similarity of these cases, coupled with parental consanguinity, suggests a primary malformation in brain development due to the homozygous representation of a mutant allele. We hypothesize that these patients may represent a defect in a gene important in brain development, the nature of which has yet to be elucidated.

Abnormalities, Multiple↗

Polymerase chain reaction detection of Lyme disease: correlation with clinical manifestations and serologic responses.

The authors have developed a simple, nested polymerase chain reaction (PCR) assay for amplification of an outer surface protein A (OspA) gene fragment of Borrelia burgdorferi using rapid temperature cycling and ethidium bromide detection on agarose gels, and applied it to the diagnosis of Lyme disease in humans. With denaturing and annealing temperature spikes instead of holds, cycle times were less than 20 minutes for a 30-cycle amplification. Using this rapid cycle PCR technique, as few as 5 spirochetes per mL of phosphate buffered saline were detected. In addition, B burgdorferi DNA was detected from spirochetes that had been spiked into one of several types of human body fluids including serum, synovial fluid, and cerebrospinal fluid (CSF). A number of clinical samples, which had been tested for Lyme immunoglobulin M (IgM) and immunoglobulin G (IgG) antibody were also examined. In 29 serologic positive samples (14 IgG and IgM positive, 9 IgM alone and 6 IgG alone), B burgdorferi DNA was not detected. In contrast, nine serum samples and one synovial fluid from patients with definite clinical features of Lyme disease were found to be negative by EIA and Western blot analysis for IgG and IgM antibody, but contained B burgdorferi DNA, as detected by PCR. Polymerase chain reaction analysis of serum and synovial fluid may be of significant diagnostic value in Lyme disease, especially in the absence of a serologic response in early, partially treated and seronegative chronic disease. This is the first study to report an association between PCR positivity and the absence of a serologic response to Lyme borreliosis.

Base Sequence↗

Detection of bcl-1 gene rearrangement and B-cell clonality in mantle cell lymphoma using formalin-fixed, paraffin-embedded tissues.

Mantle cell lymphoma (MCL) has recently emerged as a distinct clinicopathologic entity with characteristic molecular genetic features. Specifically, MCL are clonal B-cell neoplasms and often harbor bcl-1 gene rearrangements. Although this genetic profile is well documented, scant or no data are available on the molecular assessment of MCL using formalin-fixed, paraffin-embedded tissue as a sample source. The polymerase chain reaction (PCR) was employed to study bcl-1 and immunoglobulin heavy chain (IgH) gene rearrangements (B-cell clonality) using formalin-fixed tissue from 12 cases of MCL. In addition, 12 cases of low grade B-cell lymphoma and 5 cases of reactive lymphocytic hyperplasia were studied as comparison controls. A hemi-nested PCR assay was developed to identify major translocation cluster (MTC) bcl-1 gene rearrangements, whereas IgH gene rearrangements were evaluated by both a single-step and hemi-nested approach. Bcl-1 gene rearrangements were amplified in 4 of 12 (33%) MCL, but in none of the controls. With the hemi-nested approach, B-cell monoclonality was demonstrated in 11 of 12 (92%) MCL; 6 of 6 (100%) small lymphocytic lymphomas; 1 of 2 marginal zone lymphomas; 1 of 4 follicular lymphomas; and 0 of 5 reactive lymphocytic hyperplasias. When one-step PCR was used for B-cell clonality assessment, the overall detection rate was lower, specifically: 8 of 12 (67%) MCL; 4 of 6 (67%) small lymphocytic lymphomas; 1 of 2 marginal zone lymphomas; 0 of 4 follicular lymphomas; and 0 of 5 reactive lymphocytic hyperplasias were identified as monoclonal. We have demonstrated that MTC bcl-1 gene rearrangements can be amplified from formalin-fixed tissue. In addition, monoclonal B-cell populations from MCL are better amplified with a hemi-nested approach rather than a single-step PCR assay. With specialized nucleic acid isolation techniques and appropriate PCR protocol design, formalin-fixed, paraffin-embedded tissue is an adequate source of DNA for assessing MTC bcl-1 and IgH gene rearrangements.

B-Lymphocytes↗

Antigen expression and polymerase chain reaction amplification of mantle cell lymphomas.

Flow immunophenotyping, DNA content analysis, and polymerase chain reaction (PCR) amplification for t(11;14) and t(14;18) were performed on 11 cases of typical mantle cell lymphoma (MCL), 5 cases of apparent MCL with proliferation centers (MCL-PC), and 5 cases of small lymphocytic lymphoma (SLL). Immunophenotyping showed IgM (P < .001), Ig light (P < .001), and CD20 (P < .001) expression to be more intense in MCL than in SLL. In MCL-PC, the mean intensity of IgM, Ig light chain, and CD20 expression was intermediate to the intensities observed in MCL and SLL. Furthermore, in contrast to SLL, all MCL and 4 of 5 MCL-PC cases exhibited stronger CD20 than CD19 expression. CD10 expression was not observed in any case and CD5 expression was present in all SLL and MCL-PC cases and in 9 of 11 MCL cases. DNA content analysis showed an S-phase fraction of less than 3% in all cases studied and, except for 1 MCL case, all lymphomas were DNA diploid. The t(11;14) breakpoint junctions involving the bcl-1 major translocation cluster were amplified by PCR in 4 of 11 (36%) MCL cases and in none of the MCL-PC or SLL cases. The t(14;18) involving the bcl-2 major breakpoint region was not identified by PCR in any case. We conclude that the level of expression of surface antigens and the rapid detection of t(11;14) by PCR are potentially useful for distinguishing MCL and SLL in the clinical setting. Further investigations as to the biologic relationship between MCL, MCL-PC, and SLL, and the utility of t(11;14) PCR in these lymphomas are warranted.

Aged↗

Improved DNA content histograms from formalin-fixed, paraffin-embedded liver tissue by proteinase K digestion.

An improved method for the enzymatic digestion of formalin-fixed, paraffin-embedded liver tissue for DNA content analysis by flow cytometry is presented. Forty samples of histologically normal liver were alternately digested by the traditional pepsin method or a new method utilizing proteinase K and heat. Sixteen (40%) of the pepsin-digested samples had apparent DNA aneuploid peaks by flow cytometry. False DNA aneuploid peaks were not present in any of the histograms obtained after proteinase K digestion. Microscopy showed that the pepsin-digested samples had residual cytoplasmic remnants which contained fluorescent material. Samples digested with proteinase K had few cytoplasmic remnants. The average G0/G1 coefficient of variation after proteinase K treatment was lower (41%) and the fluorescent intensity higher (128%) than the pepsin-treated samples. The apparent mean S-phase (a combination of S-phase cells and underlying debris) after proteinase K digestion was 35% of the pepsin-treated samples. Primary and secondary tumors of the liver that were DNA aneuploid after pepsin treatment were also DNA aneuploid after proteinase K treatment. A modified digestion protocol utilizing proteinase K and heat can provide superior results for DNA content analysis of formalin-fixed, paraffin-embedded liver tissue.

Aneuploidy↗

Rapid cycle allele-specific amplification: studies with the cystic fibrosis delta F508 locus.

Rapid cycle DNA amplification is a polymerase chain reaction technique with improved product specificity and cycle times of 20-60 s, allowing complete 30-cycle reactions in 10-30 min. The presence or absence of the delta F508 deletion and wild-type allele was determined in 104 cystic fibrosis patients by rapid cycle DNA amplification. In separate allele-specific assays, sequences on both sides of the delta F508 locus were amplified with the 3' end of a discriminating primer at the delta F508 locus, with either a 3-bp or a 1-bp mismatch. With rapid cycling (35-s cycles), single-base discrimination was achieved over a broad range of annealing temperatures (50 degrees C or lower); with conventional cycling and "hot starts" (160-s cycles), only annealing temperatures of 61-62 degrees C sufficiently discriminated between alleles. With rapid cycling, genotype could still be assessed with annealing temperatures as low as 25 degrees C. We conclude that faster temperature cycling can improve the results of allele-specific amplification.

Base Sequence↗

Cytomegalovirus infection, fetal liver disease, and neonatal hemochromatosis.

Neonatal hemochromatosis is an uncommon disorder, clinicopathologically defined by severe and generally fatal liver disease of intrauterine onset associated with extrahepatic siderosis that spares reticuloendothelial elements (hemochromatotic siderosis). The agent or agents of liver disease in neonatal hemochromatosis are not known. It also is not known if intrauterine liver disease of defined infective etiology can lead to hemochromatotic siderosis. We present two patients with fetal liver disease and hemochromatotic siderosis whose cases help address these points. In the first patient rare hepatobiliary and numerous renal tubular cytomegalovirus (CMV) inclusions were found; CMV infection was confirmed by the polymerase chain reaction. Studies of the mother of the second patient 1, 5, and 9 weeks post-partum showed recent seroconversion against CMV; seroconversion against other infectious agents (toxoplasma, rubella, herpes, parvovirus B19, hepatitis A/B/C) was not present. Histologic, immunohistochemical, in situ hybridization, or polymerase chain reaction evidence of CMV infection was not present in infant tissues, even though peripartum maternal seroconversion against CMV was observed. We conclude that hemochromatotic siderosis may accompany chronic fetal liver disease of defined infective etiology (patient no. 1) and that recent maternal seroconversion against CMV in the presence of severe fetal liver disease does not necessarily mean that transplacentally acquired CMV infection caused the fetal liver disease (patient no. 2). Polymerase chain reaction documentation of infective-agent genomic sequences in fetal or infant tissues permits more accurate interpretation of maternal serologic data.

Adolescent↗

Digoxigenin-labeled probes amplified from genomic DNA detect T-cell gene rearrangements.

The detection of clonal rearrangements of the human T-cell receptor by Southern hybridization is a useful tool to diagnose morphologically difficult lymphoid proliferations. Widespread application of this method has been facilitated by the advent of sensitive nonradiolabeled probes. Although a limited number of nonradiolabeled DNA probes are commercially available, other probes must be obtained through a time-consuming and technically difficult procedure of amplification, isolation, and labeling of plasmid-cloned DNA sequences. A simple and time-saving procedure to simultaneously amplify and nonradioactively label DNA probes for use in gene rearrangement studies is described. Specifically, a method using the polymerase chain reaction to amplify and label with digoxigenin large quantities of probe to the constant region of the T-cell receptor directly from genomic DNA is described. The resultant probes are specific for the T-cell receptor-constant region, detect the appropriate germline configuration in placental DNA, and identify rearranged clonal T-cell proliferations. The polymerase chain reaction digoxigenin-labeled probes are suitable for detection by conventional colorimetric methods or by chemiluminescent detection schemes.

Amino Acid Sequence↗