Search PubMed⌕ Search

Biomedical subjects

Bernd Hamm

Publications and source records attributed to Bernd Hamm.

At least 55 records · Page 3Linked to original sources

[Noninvasive diagnosis of coronary artery disease].

BACKGROUND: Coronary artery disease (CAD) is one of the most common diseases that accounts for a considerable part of health care reimbursement. Thus, noninvasive diagnosis of CAD is likewise of pivotal importance for medical care today. NONINVASIVE DIAGNOSIS OF CAD: In this review, the authors present the entire spectrum of noninvasive diagnostic methods available for CAD starting with a Ergomedescription and discussion of the simplest and most important clinical approaches (patients' complaints, risk factors, electrocardiogram, and treadmill test). The established imaging modalities for diagnosing CAD (echocardiography, stress echocardiography, and scintigraphy including the SPECT and PET technique) are presented outlining their specific advantages and disadvantages. Finally, the authors discuss the most recent imaging modalities for the diagnosis of CAD (multislice computed tomography [MSCT] and magnetic resonance imaging [MRI]). MSCT allows for performing high-quality noninvasive coronary angiography, whereas MRI enables exact visualization of myocardial function, perfusion, and viability. CONCLUSION: The comprehensive assessment possible with MSCT and MRI and future developments will change the significance and importance of the conventional diagnostic methods for the diagnosis of CAD in the near future.

Adult↗

Assessment of myocardial infarction in pigs using a rapid clearance blood pool contrast medium.

Delayed enhancement MRI using extracellular contrast media allows reliable detection of myocardial infarction. If blood pool contrast media like P792 (Vistarem, Guerbet, France), in addition to improving coronary MR angiography, can be shown to also produce delayed enhancement in myocardial infarction they could improve the prerequisites for a comprehensive cardiac MR examination. In this study reperfused myocardial infarction in five minipigs was imaged with an inversion-recovery fast low-angle shot sequence using P792 (0.013 mmol Gd/kg) and the extracellular contrast medium Gd-DOTA (Dotarem, 0.1 mmol Gd/kg, Guerbet). The infarction size determined on MRI using P792 (7.55 +/- 2.31 cm(2)) highly correlated both with histomorphometry (7.81 +/- 2.18 cm(2), r = 0.991, P < 0.002) and with MRI using Gd-DOTA (7.85 +/- 2.35 cm(2), r = 0.978, P < 0.005). Bland-Altman analysis showed that the limit of agreement of MRI using P792 compared to histomorphometry was 3.3 +/- 7.6% of the infarction size. The contrast-to-noise ratio between infarcted and remote myocardium was not significantly different between Gd-DOTA (5.9 +/- 2.4) and P792 (4.4 +/- 1.1, P = 0.5). The blood pool contrast medium P792 allows reliable assessment of viability with good contrast and accuracy.

Animals↗

Changes in right ventricular dimensions and performance after passive cardiac containment.

BACKGROUND: Previous studies have shown that the cardiac support device (CSD) improves left ventricular structure and function in patients with heart failure by preventing further cardiac enlargement. The aim of this study was to identify effects on the right ventricle (RV). METHODS: Ten male patients with idiopathic dilated cardiomyopathy underwent electron-beam computed tomographic (CT) examination within 1 month before, and 6 to 9 months after CSD implantation. The RV end-diastolic and end-systolic volumes (EDV, ESV) and diameters (EDD, ESD), stroke volume (SV), ejection fraction (EF), total and forward RV output (RVO, fRVO), and tricuspid regurgitation fraction (TRF) were calculated. RESULTS: The EDV measurements decreased from 182.1 +/- 49.6 to 137.5 +/- 37.0 mL, ESV from 114.8 +/- 47.0 to 68.3 +/- 23.8 mL, EDD from 48.2 +/- 6.6 to 41.6 +/- 7.1 mm, and ESD from 39.6 +/- 6.9 to 32.7 +/- 6.5 mm (p < 0.05 for each). Ejection fraction increased from 38.5 +/- 8.9 to 52.0% +/- 7.7% and fRVO from 4.0 +/- 0.8 to 4.6 +/- 1.1 L/min (each with p < 0.05). TRF decreased from 18.2 +/- 14.1 to 10.4% +/- 13.5%, whereas SV and RVO remained nearly unchanged. Postoperatively, RV volumes, EF, and fRVO were not different from 15 age- and gender-matched normal control patients. CONCLUSIONS: Implantation of a CSD leads to a decrease in RV size and improved RV performance. These data together with the results of previous studies demonstrating improved left ventricular structure and function confirm the biventricular nature of recovery with the CSD.

Cardiomyopathy, Dilated↗

Isotropic half-millimeter angiography of coronary artery bypass grafts with 16-slice computed tomography.

BACKGROUND: Computed tomography (CT) with four detector rows and magnetic resonance imaging (MRI) are still of limited value for the assessment of coronary artery bypass grafts (CABG). We investigated the abilities of 16-slice CT in these patients. METHODS: A retrospective analysis of all noninvasive coronary angiographies with multislice computed tomography (MSCT; Aquilion, Toshiba) on patients with CABG referred to our institution between October 2002 and April 2003 was conducted. MSCT angiography was performed using a standard protocol (0.5-seconds rotation time, 16 x 0.5 mm detector collimation, 120 kV, 250 to 300 mA, and 0.25 pitch). None of the patients received beta-blockers to reduce the heart rate. Seventy-five CABGs (20 arterial grafts and 55 venous grafts) in 27 patients were evaluated for patency and adequate diagnostic quality by two radiologists in consensus. RESULTS: All arterial and venous grafts were depicted with adequate diagnostic quality and were eligible for evaluation. Fifteen occlusions and five significant stenoses (at least 50%) could be identified. All of the proximal and 99% of the distal anastomoses were eligible. One distal anastomosis of an arterial graft was not assessable due to surgical clip artifacts. The length of the acquisition window was 174 +/- 46 ms (range 71 to 234 ms). The majority of the patients (70%) had a heart rate above 65 beats/min. However, due to the improved temporal and spatial resolution none of the examinations had an insufficient image quality. CONCLUSIONS: MSCT angiography with 16 detector rows and an isotropic high resolution reliably depicts CABG with adequate diagnostic quality.

Coronary Angiography↗

Passive external cardiac constraint improves segmental left ventricular wall motion and reduces akinetic area in patients with non-ischemic dilated cardiomyopathy.

OBJECTIVE: To verify changes in left ventricular (LV) volumes and regional myocardial wall motion after implantation of a textile cardiac support device (CSD) for passive external constraint in non-ischemic dilated cardiomyopathy. METHODS: In nine male patients participating in a non-randomized clinical trial LV volumes were determined and the segmental LV wall motion was studied by contrast-enhanced electron-beam CT in a sectionwise manner at three ventricular levels (base, middle and apex of ventricle) before and 32+/-6 months after CSD implantation. In 16 myocardial segments ejection fraction and wall thickening were measured semiautomatically after drawing the myocardial contours. The wall motion score index was calculated based on semiquantitative visual grading in each segment. RESULTS: The global LV volumes decreased significantly from 304.3 +/- 90.9 to 231.5 +/- 103.9 ml at end-diastole and from 239.7 +/- 83.7 to 164.0 +/- 97.7 at end-systole (P<0.05). Overall ejection fraction increased from 14.8 +/- 8.2 to 25.7 +/- 17.1% (P<0.05). A segment-by-segment analysis demonstrated a significant increase of regional ejection fraction in the basal myocardium as well as in the mid-inferior, mid-inferolateral, and mid-anterolateral myocardium. Overall wall thickening increased from 16.4 +/- 13.3 to 24.2 +/- 18.1% (P<0.05), but without significant differences in a segment-by-segment comparison. The mean wall motion score index improved from 2.70 +/- 0.26 to 2.20 +/- 0.71 (P<0.05), with an increased wall motion in eight (89%) patients. A section-by-section analysis demonstrated significantly improved wall motion in the inferior and lateral segments at each ventricular level. Postoperatively, the number of akinetic and markedly hypokinetic segments decreased significantly (P<0.05) from 56 (39%) to 26 (18%) and from 76 (53%) to 56 (37%), respectively. CONCLUSION: CSD implantation improves segmental wall motion, predominantly in the inferior and lateral myocardium, and reduces the number of akinetic and hypokinetic segments.

Adult↗

Effects of passive cardiac containment on left ventricular structure and function: verification by volume and flow measurements.

BACKGROUND: The cardiac support device (CSD, Acorn) is a compliant, textile-mesh graft placed around the ventricles to prevent further dilatation and to improve function in congestive heart failure. The aim of this study was to verify post-operative changes in left ventricular volumes, ejection fraction, blood flow, and myocardial mass. METHODS: Fourteen patients underwent contrast-enhanced, electrocardiography-triggered electron-beam computerized tomography before and 6 to 9 months after CSD implantation. We measured volume and flow using the slice-summation method and the indicator-dilution technique. RESULTS: We found significant changes for the following parameters: end-diastolic volume decreased from 382.9 +/- 140.2 ml to 311.3 +/- 138.7 ml, end-systolic volume from 310.4 +/- 132.4 ml to 237.4 +/- 133.8 ml, end-diastolic diameter from 75.3 +/- 7.8 mm to 70.7 +/- 11.6 mm, end-systolic diameter from 65.8 +/- 7.8 mm to 60.0 +/- 14.0 mm, and myocardial mass from 298.6 +/- 79.6 g to 263.1 +/- 76.8 g. Ejection fraction increased from 20.3% +/- 6.4% to 27.8% +/- 13.1%. We found no significant differences for stroke volume (from 72.5 +/- 24.6 ml to 73.8 +/- 23.6 ml), heart rate (from 80.5 +/- 11.0 beats per minute to 76.5 +/- 6.8 beats per minute), and total cardiac output (from 5.8 +/- 1.9 liter/min to 5.6 +/- 1.8 liter/min). Mitral regurgitation fraction decreased from 30.5% +/- 15.5% to 15.6% +/- 12.8%, increasing antegrade cardiac output from 3.8 +/- 0.9 liter/min to 4.7+/-1.5 liter/min. For most parameters, pre- and post-operative values in these patients differed significantly from those in an age- and gender-matched control group. In each patient, we observed a small hyperdense stripe along the pericardium after surgery, but we observed no local complications. CONCLUSION: Three-dimensional structural and functional data obtained by computerized tomography volume and flow measurements confirm the safety and efficacy of CSD implantation.

Adult↗

Quantification of functional mitral valve regurgitation in patients with congestive heart failure: comparison of electron-beam computed tomography with cardiac catheterization.

OBJECTIVES: We sought to determine the agreement between electron-beam computed tomography (CT) and cardiac catheterization for the quantification of mitral regurgitation and to evaluate their association with echocardiographic assessment. MATERIAL AND METHODS: Fifty patients with congestive heart failure were examined both by electron-beam CT and catheterization to calculate mitral regurgitation volume and fraction based on the difference between the left ventricular stroke and aortic flow volume. The severity of regurgitation was also compared with visual assessment by echocardiography (grade, 0-4+). RESULTS: The mean values for the mitral regurgitation volume and fraction did not differ significantly between electron-beam CT and catheterization (mean differences: 0.2 mL/m2 and -0.9%, P > 0.05 each, limits of agreement: -14.0 to 14.4 mL/m2 and -26.3 to 24.5%, respectively) and showed a good correlation (r = 0.79 and r = 0.76, respectively; P < 0.05 each). Good levels of correlation were observed between echocardiographic severity grading and quantitative measurements of regurgitation volume and fraction, which were somewhat better between echocardiography and electron-beam CT (rS = 0.78 and rS = 0.84, respectively; P < 0.05 each) than between echocardiography and catheterization (rS = 0.72 and rS = 0.81, respectively; P < 0.05 each). CONCLUSION: Our results suggest that electron-beam CT allows for quantification of mitral valve regurgitation with similar accuracy as cardiac catheterization. Measurements with both modalities correlated well with the results of echocardiographic assessment.

Adult↗

Multisegment and halfscan reconstruction of 16-slice computed tomography for detection of coronary artery stenoses.

RATIONALE AND OBJECTIVES: To compare the diagnostic accuracy and image quality of 2 reconstruction algorithms (multisegment and halfscan) for computed tomography (CT) coronary angiography in patients without beta-blocker medication. MATERIALS AND METHODS: Thirty-four patients with 42 significant coronary stenoses in 136 main coronary branches were examined using a 16-slice CT scanner (Aquilion, Toshiba, Otawara, Japan). Twenty-seven patients (79%) had heart rates above 65 beats/min. RESULTS: Without exclusion of branches the sensitivity, specificity, accuracy, and rate of nonassessable segments with multisegment versus halfscan reconstruction were 88 versus 74%, 91 versus 71%, 90 versus 72%, and 2 versus 21% (P < 0.01), respectively. Multisegment reconstruction improved the average vessel length free of motion artifacts by 56% compared with halfscan reconstruction (P < 0.01). Image quality in terms of vessel continuity and visibility of side branches (P < 0.005) was significantly better using multisegment reconstruction. CONCLUSIONS: Multisegment reconstruction has superior diagnostic accuracy and image quality compared with halfscan reconstruction in patients with normal heart rates.

Adult↗

Image quality of noninvasive coronary angiography using multislice spiral computed tomography and electron-beam computed tomography: intraindividual comparison in an animal model.

OBJECTIVE: Comparison of coronary artery visualization by multislice spiral CT (MSCT) and electron-beam CT (EBCT). MATERIALS AND METHODS: Six minipigs underwent MSCT (collimation 4 x 1 mm, gantry rotation time 500 milliseconds, acquisition time per cardiac cycle 126 +/- 30 milliseconds) and EBCT (slice thickness 1.5 mm, acquisition time per scan 100 milliseconds). Visualized vessel length and contour sharpness was measured, contrast-to-noise ratios were calculated, and the frequency of motion artifacts were evaluated. RESULTS: MSCT depicted significantly longer segments of the coronary tree than EBCT (length: 248.8 vs. 222.8 mm; P < 0.05), delineated the vessel contours more sharply (slope of density curves: 219.2 vs. 160.2 DeltaHU/mm; P < 0.05), and had a higher contrast-to-noise ratio (13.4 vs. 7.3; P < 0.05). The frequency of motion artifacts did not differ between both modalities (94.7% vs. 95.7% of visualized vessel length; P > 0.05). CONCLUSIONS: Because its higher spatial resolution and lower image noise, MSCT seems to be superior to EBCT in the visualization of the coronary arteries. Despite different temporal resolutions motion artifacts seem to be similar with both modalities.

Animals↗

Magnetic resonance imaging of myocardial perfusion and viability using a blood pool contrast agent.

RATIONALE AND OBJECTIVES: A comprehensive cardiac magnetic resonance (MR) examination should comprise imaging of myocardial perfusion, viability, and the coronary arteries. Blood pool contrast agents (BPCAs) improve coronary MR angiography, whereas their potential for imaging of perfusion and viability is unknown. The abilities to noninvasively image myocardial perfusion and viability using the BPCA P792 (Guerbet, France) were tested in a closed-chest model of nonreperfused myocardial infarction in 5 pigs. MATERIALS AND METHODS: Two to 3 days after instrumentation, myocardial perfusion imaging with a saturation-recovery steady-state free precession technique and viability imaging with an inversion-recovery fast low-angle shot sequence were conducted on a 1.5-T MR scanner using the extracellular contrast agents (ECCA) Gd-DOTA (0.1 mmol Gd/kg) and blood pool contrast agent (BPCA) P792 (0.013 mmol Gd/kg). RESULTS: Perfusion defects were visualized in all pigs with good correlation between the ECCA and the BPCA (1.77 +/- 1.16 cm2 vs. 1.80 +/- 1.19 cm2, r = 0.959, P < 0.01). Reduced myocardial perfusion was detected using the ECCA up to 80 seconds after injection. In contrast, BPCA administration enabled visualization of perfusion defects on equilibrium perfusion imaging in all cases for 10 minutes. The size of myocardial infarction detected with viability MR imaging correlated well between the standard method (ECCA) and delayed-enhancement imaging with the BPCA (5.40 +/- 3.16 versus 5.52 +/- 3.13 cm3, r = 0.994, P < 0.002). CONCLUSIONS: The BPCA investigated in this study allows both reliable detection of perfusion defects on first pass and equilibrium perfusion imaging and characterization of viability after myocardial infarction. Thus, this contrast agent is suitable for a comprehensive cardiac MR examination.

Animals↗

Phase I clinical evaluation of citrate-coated monocrystalline very small superparamagnetic iron oxide particles as a new contrast medium for magnetic resonance imaging.

RATIONALE AND OBJECTIVES: To evaluate the safety and pharmacokinetics of a newly developed MR contrast medium consisting of very small superparamagnetic iron oxide particles (VSOP) coated with citrate (VSOP-C184) in a clinical phase I trial. METHODS: A total of 18 healthy subjects received either VSOP-C184 (core diameter: 4 nm; total diameter: 7 +/- 0.15 nm; relaxivities in water at 0.47 T (T1) 18.7 and (T2) 30 L/(mmol*seconds)) at doses of 0.015, 0.045, or 0.075 mmol Fe/kg (n = 5 per dose) or placebo (n = 1 per dose) as intravenous injections. Physical status and vital parameters were recorded, blood samples were collected for clinical chemistry and relaxometry (0.94 T), and urinalyses were performed before and for up to 2 weeks after administration. RESULTS: No serious adverse events occurred. The most pronounced adverse events occurred in 2 subjects of the highest dose group 45-50 minutes after injection. These were a drop in blood pressure and a drop in oxygen saturation, which were considered to be possibly drug-related and rapidly resolved without medication. Otherwise, no relevant changes in vital and laboratory parameters were observed. The parameters of iron metabolism exhibited short-term, dose-related changes. The injection of VSOP-C184 decreased T1 relaxation time of blood below 100 milliseconds for 18 minutes after a dose of 0.045 mmol [corrected] Fe/kg and for 60 minutes after 0.075 mmol [corrected] Fe/kg. CONCLUSIONS: The favorable data on the safety, tolerability, and efficacy of VSOP-C184 justify further clinical phase II and III trials as a contrast medium for MRI.

Adult↗

Comparison of the iron oxide-based blood-pool contrast medium VSOP-C184 with gadopentetate dimeglumine for first-pass magnetic resonance angiography of the aorta and renal arteries in pigs.

RATIONALE AND OBJECTIVES: VSOP-C184 at a dose of 0.045 mmol Fe/kg has been shown to be an efficient blood pool contrast medium for equilibrium magnetic resonance angiography (MRA) that can be administered as a bolus. The present study was performed to determine whether VSOP-C184 is also suitable for first-pass MRA. MATERIALS AND METHODS: Fifteen MRA examinations at 1.5 T were performed in minipigs using a fast 3D fast low-angle shot (FLASH) sequence (repetition time = 4.5 ms, echo time = 1.7 ms, excitation angle = 25 degrees, matrix 256, body phased-array coil). The citrate-stabilized iron oxide preparation VSOP-C184 was investigated (total particle diameter: 7.0 +/- 0.15 nm; core size: 4 nm) and compared with gadopentetate dimeglumine (Gd-DTPA). The following doses were tested: VSOP-C184: 0.015, 0.025, and 0.035 mmol Fe/kg; Gd-DTPA: 0.1 and 0.2 mmol Gd/kg; n = 3 examinations/dose. Data were analyzed quantitatively (signal enhancement (ENH) and vessel edge definition (VED)) and qualitatively. RESULTS: First-pass MRA using the 3 doses of VSOP-C184 yielded the following ENH: aorta: 9.4 +/- 2.6; 12.31 +/- 1.2; 16.53 +/- 1.7; renal arteries: 7.6 +/- 2.2; 9.9 +/- 1.0; 13.2 +/- 0.5. The values for the 2 doses of Gd-DTPA were aorta: 12.9 +/- 1.0; 16.8 +/- 2.2; renal arteries: 11.2 +/- 1.23; 11.3 +/- 1.7. VED for the 3 doses of VSOP-C184 was aorta: 106.3 +/- 31.0; 135.3 +/- 58.8; 141.3 +/- 71.0; renal arteries: 102.2 +/- 24.3; 146.8 +/- 63.0; 126.9 +/- 37.6 and for the 2 doses of Gd-DTPA, aorta: 157.2 +/- 47.8; 164.2 +/- 36.8; renal arteries: 165.9 +/- 30.4; 170.3 +/- 38.2 respectively. The differences between VSOP-C184 and Gd-DTPA are clinically not relevant and statistically not significant (p > or = .05). Qualitative evaluation of image quality, contrast, and delineation of vessels showed the results obtained with VSOP-C184 at doses of 0.025 and 0.035 mmol Fe/kg to be similar to those of Gd-DTPA at 0.1 and 0.2 mmol Gd/kg. CONCLUSION: VSOP-C184 is suitable for first-pass MRA at doses of 0.025 and 0.035 mmol Fe/kg and thus, in addition to its blood pool characteristics, allows for selective visualization of the arteries without interfering venous signal.

Animals↗

Coronary artery disease: new insights and their implications for radiology.

Coronary artery disease (CAD) diminishes local, regional, or global blood supply to the heart and is most commonly caused by coronary atherosclerosis. New insights into the etiology of atherosclerosis suggest that CAD is an inflammatory disorder that responds well to modulation rather than an unchangeable chronic process. Since 75% of all acute coronary syndromes result from rupture of atherosclerotic plaques, factors causing rupture have a crucial role. Magnetic resonance imaging and CT have the potential to visualize the composition of coronary artery plaques and thus to identify plaques at risk. Considering the new insights into stunning and hibernation, myocardial late enhancement on MRI might provide pivotal information for therapeutic decision making among lysis therapy, catheter intervention, and bypass surgery. Exercise electrocardiography without or with right precordial leads, stress echocardiography, and stress scintigraphy are simple clinical procedures to identify CAD with high sensitivities of 67, 92, 76, and 88%, respectively. The MRI and CT have to be compared with these good results. Nevertheless, we are expecting that MRI and CT will replace the conventional diagnostic modalities, gain a central role in diagnosing patients with suspected CAD, and prove to be cost-effective in this regard.

Coronary Disease↗

Serum levels of carboxy-terminal telopeptide of type-I collagen are elevated in patients with multiple myeloma showing skeletal manifestations in magnetic resonance imaging but lacking lytic bone lesions in conventional radiography.

PURPOSE: Skeletal involvement is a hallmark of multiple myeloma. Increased bone resorption can even be present in patients lacking osteolyses in conventional radiography. Magnetic resonance imaging (MRI) of the spine was established as a more sensitive technique to depict bone abnormalities. Type-I collagen degradation product carboxyterminal telopeptide of type-I collagen (ICTP) was introduced as a novel biochemical parameter reflecting the bone resorption activity in myeloma. The aim of this study was to evaluate whether increased ICTP serum levels predict abnormal MRI patterns in myeloma patients. EXPERIMENTAL DESIGN: MRI of the spine was performed in 32 untreated patients with multiple myeloma, who had no skeletal abnormalities in conventional radiographies. Simultaneously, ICTP was measured in serum by a competitive radioimmunoassay at corresponding time points. RESULTS: Serum ICTP was significantly (P = 0.002) elevated in patients with abnormal bone MRI compared with those patients with normal MRI findings. The sensitivity of ICTP for depiction of MRI abnormalities was 79%; the positive and negative predictive values were 85 and 84%, respectively. Compared with ICTP, the parameters of disease activity, beta2-microglobulin and C-reactive protein, had a much lower sensitivity for abnormal MRI (29 and 64%, respectively). CONCLUSIONS: In myeloma patients without osteolytic lesions in conventional radiography, abnormal skeletal MRI is accompanied by an increase in serum levels of ICTP. Our data show that ICTP can be used as an inexpensive parameter to identify myeloma patients with normal skeletal survey who have a high probability of skeletal involvement and deserve more accurate diagnostic evaluation using MRI.

Aged↗

Rheumatoid arthritis of the shoulder joint: comparison of conventional radiography, ultrasound, and dynamic contrast-enhanced magnetic resonance imaging.

OBJECTIVE: To determine the role of ultrasound and magnetic resonance imaging (MRI) compared with conventional radiography in the detection of chronic and acute inflammatory manifestations of rheumatoid arthritis (RA) of the shoulder joint. METHODS: Forty-three consecutive patients with known RA prospectively underwent clinical examination, radiography, ultrasound, and MRI of the shoulder joints. Each patient was assigned a clinical/laboratory score consisting of 7 parameters, including measurements of shoulder mobility, the erythrocyte sedimentation rate, and C-reactive protein level. Conventional radiography was standardized and performed in 2 planes. Ultrasound was performed in 10 predefined planes using a 7.5-MHz linear transducer. MRI at 1.5T comprised transverse and oblique coronal T1- and T2*-weighted fast spin-echo, gradient-echo (GRE), and inversion-recovery sequences with a matrix size of up to 512 pixels. A dynamic T1-weighted GRE sequence was acquired with intravenous administration of contrast medium. Erosions were assessed using all 3 imaging techniques on a 4-point scale. Soft-tissue involvement was evaluated according to the presence of synovitis, tenosynovitis, and bursitis on ultrasound and MRI. The results in the study group were compared with those obtained in a control group of 10 patients with shoulder pain. RESULTS: In the study group, erosions of the humeroscapular joint were detected by conventional radiography in 26 patients, by ultrasound in 30 patients, and by MRI in 39 patients; the differences were statistically significant for the comparisons of conventional radiography with MRI and for ultrasound versus MRI (P < 0.0001). Conventional radiography detected 12 erosions of the scapula and MRI detected 15. Synovitis was demonstrated in 12 patients by ultrasound and in 27 patients by MRI (P = 0.0003). Tenosynovitis was observed in 15 patients by ultrasound and in 28 patients by MRI (P = 0.0064). Bursitis was detected in 13 patients by ultrasound and in 18 patients by MRI. The findings on dynamic contrast-enhanced MRI correlated significantly with the detection of synovitis by ultrasound and erosions by static MRI (P < 0.05). CONCLUSION: Ultrasound and MRI supplement conventional radiography in assessing the shoulder joint. Although conventional radiography can be used as the sole method of following up known joint destruction in RA, ultrasound and, preferably, MRI are recommended as additional techniques in the initial diagnostic evaluation when radiography yields negative results.

Adult↗

Diameter changes of occluded venous coronary artery bypass grafts in electron beam tomography: preliminary findings.

OBJECTIVE: To differentiate acute from chronic graft occlusions through diameter measurements by means of electron beam tomography (EBT). METHODS: Contrast enhanced EBT volume studies were carried out in 37 patients with one or more occluded venous coronary bypass grafts. Seventeen of 37 patients did not meet the inclusion criteria and were excluded from the assessment. The remaining 20 patients had a total of 39 bypasses (16 patent, 23 occluded) and were assigned to one of three groups: group A consisted of patent grafts only (patent grafts, 13 patients). Group B comprised 11 of 23 occluded grafts diagnosed within 10 days after bypass surgery (acutely occluded grafts, ten patients). Group C contained 12 of 23 bypass occlusions that were at least 6 months old as documented by coronary angiography (chronically occluded grafts, ten patients). The mean graft diameter was determined by repetitive measurements on a workstation through blinded readers. The Mann-Whitney-U-test for unpaired samples was used for statistical evaluation. RESULTS: Mean graft diameter for groups A-C (patent, acutely, and chronically occluded bypasses, respectively) was 3.9 mm (+/-0.6; n=16), 5.4 mm (+/-1.9; n=11), and 0.3 mm (+/-.9; n=12), respectively (P<0.01 each). Sensitivity and specificity for the detection of acute and chronic occlusions were 87 and 92% (cut-off 4.5 mm), respectively, and 92 and 96% (cut-off 1 mm), respectively. CONCLUSIONS: EBT may allow for non-invasive differentiation between acute and chronic venous coronary bypass occlusions. This could help prevent unnecessary invasive recanalization procedures. Body veins may conserve their ability to increase in diameter in acute thrombosis when transplanted as coronary bypasses.

Acute Disease↗