Early and late effects of passive epicardial constraint on left ventricular geometry: ellipsoidal re-shaping confirmed by electron-beam computed tomography.

BACKGROUND: Previous studies have shown that passive epicardial constraint using a cardiac support device (CSD) reduces left ventricular (LV) size. However, specific data describing LV shape and the time course of changes in LV geometry are still incomplete. Thus, the aim of this study was-using 3-dimensional data sets obtained by computed tomography (CT)-to test the hypothesis that the CSD not only alters LV size but also LV shape, and that short-term post-operative changes in LV geometry are maintained during long-term follow-up. METHODS: Ten patients with non-ischemic dilated cardiomyopathy underwent electron-beam CT examination before and again at 2.6 +/- 0.5 and 32.4 +/- 8.7 months after CSD implantation. At end-diastole and end-systole LV volumes, the length-to-width diameter ratio and a sphericity index were determined and ejection fraction and end-systolic meridional and circumferential wall stress were calculated. RESULTS: Implantation of the CSD led to a significant reduction in LV size, a more ellipsoidal LV shape and a subsequent decrease of LV wall stress post-operatively (p < 0.05 for each), but no substantial changes were found between short- and long-term follow-up (p > 0.05 each). Mean pre-operative and early and late post-operative end-diastolic values were 310.4 +/- 87.8, 235.5 +/- 102.0 and 229.4 +/- 103.1 ml for volume; 1.27 +/- 0.20, 1.37 +/- 0.20 and 1.38 +/- 0.20 for diameter ratio; and 0.78 +/- 0.22, 0.67 +/- 0.26 and 0.65 +/- 0.23 for sphericity index. A similar pattern was observed for end-systolic values. Ejection fraction was 23.4 +/- 6.2%, 32.9 +/- 11.6% and 34.4 +/- 14.9%. End-systolic meridional and circumferential wall stress was 182.2 +/- 45.6, 128.2 +/- 52.6, 130.6 +/- 56.7 kdyn/cm(2) and 411.5 +/- 94.0, 297.4 +/- 108.4 and 302.8 +/- 117.5 kdyn/cm(2), respectively. CONCLUSIONS: Three-dimensional data obtained by CT demonstrate that passive cardiac constraint leads not only to a size reduction but also to an ellipsoidal re-shaping. Our data indicate that these effects are primarily a short-term consequence of the CSD implantation but are maintained during long-term follow-up.

Cardiomyopathy, Dilated↗

MRI morphology of the levator ani muscle, endopelvic fascia, and urethra in women with stress urinary incontinence.

OBJECTIVE: To evaluate pathomorphologic changes of the levator ani muscle, endopelvic fascia, and urethra in women with stress urinary incontinence (SUI) by MRI. STUDY DESIGN: Fifty-four women with SUI were examined by MRI (1.5T): body phased-array coil, axial and coronal proton-density-weighted sequences. RESULTS: The urethral sphincter muscle showed a reduced thickness of its posterior portion (37%), an omega shape (13%) or higher signal intensity (50%); its abnormal configuration was associated with an increased signal intensity in 70% (p=0.001). The levator ani muscle comprised an unilateral loss of substance in 30%, a higher signal intensity in 28%, and altered origin in 19%. Central defects of the endopelvic fascia were present in 39% (n=21), lateral defects in 46%. There was a significant association between loss of the symphyseal concavity of the anterior vaginal wall and lateral fascial defects (p=0.001) and levator ani changes (p=0.016). CONCLUSION: MRI yields findings supporting current theories on the pathogenesis of SUI.

Adult↗

Percutaneous discography: comparison of low-dose CT, fluoroscopy and MRI in the diagnosis of lumbar disc disruption.

AIM: To compare the diagnostic accuracy of low-dose computed tomography (CT), magnetic resonance imaging (MRI) and fluoroscopy in percutaneous discography in patients scheduled for lumbar spondylodesis. MATERIAL AND METHODS: Within a prospective pilot study, 18 disc segments of 11 patients with radicular or pseudoradicular pain prior to anteroposterior spondylodesis were evaluated. After injection of a mixture of non-ionic iodine-containing contrast agent and gadolinium-based contrast medium into the disc spaces, all patients underwent conventional fluoroscopy, as well as low-dose CT and MRI. The occurrence of memory pain during contrast injection was recorded. CT, MRI and fluoroscopic images were analyzed independently by two readers blinded to the clinical findings. RESULTS: There was 100% agreement between CT and MRI discography in the detection, localization and grading of degenerative changes. In contrast, conventional fluoroscopy identified only 9 of the 12 abnormal segments. Memory pain following puncture was identified in 3 of the 12 affected segments. SUMMARY: Low-dose CT and MRI discography have a similar accuracy in the assessment of disc disruption and they are superior to fluoroscopic discography.

Adult↗

Magnetic resonance cholangiopancreatography using a free-breathing T2-weighted turbo spin-echo sequence with navigator-triggered prospective acquisition correction.

PURPOSE: The objective of this study was to evaluate the image quality of a respiratory-triggered T2-weighted (T2w) turbo spin-echo (TSE) sequence for magnetic resonance cholangiopancreatography (MRCP) using a new method for respiratory triggering by tracking the motion of the right diaphragm [prospective acquisition correction (PACE) technique]. MATERIALS AND METHODS: Fifty consecutive patients underwent MRCP imaging applying breath-hold half-Fourier single-shot TSE sequences and the respiratory-triggered T2w TSE sequence. Qualitative evaluation grading the depiction of eight segments of the pancreaticobiliary tree and the frequency of artifacts was performed. Quantitative evaluation included calculation of the relative contrast (RC) between fluid-filled ductal structures and organ parenchyma at four segments. RESULTS: A significantly higher (P<.01) RC was measured for the respiratory-triggered T2w TSE sequence [maximum intensity projection (MIP)] for all of the four investigated segments (one of four segments for the MIP) of the pancreaticobiliary tree, as well as a significant (P<.01) improvement of visualization of all ductal segments compared with the breath-hold sequences. The frequency of artifacts was significantly lower (P<.01) compared with the breath-hold sequences. CONCLUSION: Respiratory-triggered MRCP using a T2w TSE sequence with PACE significantly improves image quality and may be included into the routine MRCP sequence protocol.

Adult↗

Evaluation of a semiautomatic software tool for left ventricular function analysis with 16-slice computed tomography.

The purpose of the study was to evaluate a semiautomatic analysis tool for assessing global left ventricular myocardial function with multislice computed tomography (MSCT). We examined 33 patients with MSCT using 16x0.5 mm detector collimation and magnetic resonance imaging (MRI) on a 1.5-T scanner. MSCT data were analyzed using semiautomatic volumetric analysis software (ANET, CSCF-001A, Toshiba). This software tool automatically creates endo- and epicardial contours that can be manually corrected on all short-axis slices at all reconstructed time points within the cardiac cycle, based on a contour-detection and density-threshold algorithm. All global left ventricular function parameters assessed with the semiautomatic MSCT software were highly correlated with the results of MRI. Bland-Altman analysis showed minor systematic overestimation of end-diastolic (10.7 ml) and end-systolic volumes (5.6 ml) and underestimation of ejection fraction (2.1%) with MSCT as compared with MRI. The post-processing time was moderately but significantly longer with the MSCT software (15.9+/-2.8 min) than necessary for MRI (14.0+/-2.5 min, P<0.01), mainly as a result of the longer time required for uploading of the MSCT datasets, which were on average 54 times larger (1.3 GByte). In conclusion, it appears feasible to accurately assess global left ventricular function with MSCT in a reasonable post-processing time using a semiautomatic software tool.

Contrast Media↗

A novel ultrasonographic synovitis scoring system suitable for analyzing finger joint inflammation in rheumatoid arthritis.

OBJECTIVE: To develop an ultrasonographic (US) synovitis scoring system suitable for evaluation of finger joint inflammation in patients with active rheumatoid arthritis (RA) and to compare semiquantitative US scoring with quantitative US measurements. METHODS: US was performed at the palmar and dorsal sides of the second through fifth metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints in 10 healthy subjects and in the clinically more affected hand in 46 RA patients. Ten patients additionally underwent magnetic resonance imaging (MRI). Synovitis was measured, standardized, and scored according to a semiquantitative method. The 2 methods (semiquantitative US scoring, quantitative US) were compared and statistical cutoffs were identified using receiver operating characteristic (ROC) curve analysis. MRI results were compared with semiquantitative US scoring and quantitative US results. The optimal US scoring method from 6 joint combinations was identified (ROC curve analysis). RESULTS: Synovitis was most frequently detected in the palmar proximal area (86% of affected joints). We found no significant differences between individual PIP joints or between individual MCP joints, indicating that all fingers within each of these joint groups should be treated equally for statistical calculations, although each joint group as a whole should be treated separately. The optimal cutoff point to distinguish between "health" and "pathology" was 0.6 mm both for MCP joints (sensitivity 94%, specificity 89%) and for PIP joints (sensitivity 90%, specificity 88%). There was no significant difference between semiquantitative US scores and quantitative US measurements. The best results for joint combinations were achieved using the "sum of 4 fingers" (second through fifth MCP and PIP joints) and "sum of 3 fingers" (second through fourth MCP and PIP joints) methods. Comparison of MRI results with semiquantitative US scores revealed high concordance. CONCLUSION: US evaluation of finger joint synovitis can be considerably simplified by focusing on the palmar side and by applying semiquantitative grading instead of quantitative measurements. For evaluation of treatment efficacy based on synovitis in RA patients, we recommend using the "sum of 3 fingers" method in longitudinal trials.

Adolescent↗

Contrast-enhanced magnetic resonance angiography of the lower extremities: standard-dose vs. high-dose gadodiamide injection.

PURPOSE: To compare the efficacy and safety of two different doses (0.1 and 0.3 mmol/kg of body weight [BW]) of gadodiamide for contrast-enhanced magnetic resonance angiography (ce-MRA) of the lower extremities with intraarterial digital subtraction angiography (IA-DSA). MATERIALS AND METHODS: A total of 30 patients with peripheral arterial occlusive disease underwent IA-DSA and ce-MRA from the aortic bifurcation down to the ankle. Patients were randomized to receive a total dose of 0.1 or 0.3 mmol/kg of BW gadodiamide (Omniscan, Amersham Buchler), administered intravenously as a series of three automatic bolus injections. Ce-MRA was performed with a 1.5-T system using a body phased-array coil, centered stepwise over the calf, thigh, and pelvic region. A fast T1-weighted, three-dimensional gradient-echo sequence was obtained before and after injection of the allocated dose. IA-DSA was performed using the Seldinger technique and a femoral approach. The vessels under investigation were divided into 31 segments, and ce-MRA and IA-DSA image sets were evaluated in a double-blind fashion for the presence of stenosis, presence of collateral vessels, vessel delineation, and overall image quality. Both dose groups were compared with regard to contrast index (CI) and signal- and contrast-to-noise ratios (SNR, CNR). The occurrence of adverse events or side effects was also documented. Sensitivity, specificity, and accuracy were calculated in relation to the results of stenosis grading. RESULTS: A total of 26 patients were entered in the efficacy evaluation, while all 30 patients were included in the safety assessment. The sensitivity, specificity, and accuracy for the 0.1 and 0.3 mmol/kg dose groups were 78.8%/93.0%/88.9% vs. 60.2.%/91.5%/83.2%, respectively. The detection of collaterals was similar to IA-DSA for the 0.3 mmol/kg dose group (30.2% vs. 27.4%), but was lower in the 0.1 mmol/kg dose group (27.3% vs. 12.3%). The high-dose gadodiamide injection proved to be superior to the 0.1 mmol/kg dose group with regard to vessel delineation and overall image quality (P = 0.007 and P = 0.002, respectively). The difference between the two dose groups regarding CI, SNR, and CNR was significant (P = 0.0001), in favor of the 0.3 mmol/kg dose group. No adverse events were observed in any of the patients. CONCLUSION: Ce-MRA with gadodiamide is safe and efficacious. Comparison of two different doses with IA-DSA as the standard of reference showed that the 0.3 mmol/kg dose is superior to the standard 0.1 mmol/kg dose with respect to contrast enhancement, vessel delineation, image quality, and detection of collaterals. However, the 0.1 mmol/kg dose was superior to the high dose in the grading of stenosis.

Aged↗

Magnetic resonance imaging of the upper abdomen using a free-breathing T2-weighted turbo spin echo sequence with navigator triggered prospective acquisition correction.

PURPOSE: To evaluate a free-breathing navigator triggered T2-weighted turbo spin-echo sequence with prospective acquisition correction (T2w-PACE-TSE) for MRI of the upper abdomen in comparison to a conventional T2-weighted TSE (T2w-CTSE), a single-shot TSE (T2w-HASTE), and a T1-weighted gradient-echo sequence (T1w-FLASH). MATERIALS AND METHODS: A total of 40 consecutive patients were examined at 1.5 T using free-breathing T2w-PACE-TSE, free-breathing T2w-CTSE, and breath-hold T2w-HASTE and T1w-FLASH acquisition. Images were evaluated qualitatively by three radiologists regarding motion artifacts, liver-spleen contrast, depiction of intrahepatic vessels, the pancreas and the adrenal glands, and overall image quality on a four-point scale. Quantitative analysis of the liver-spleen contrast was performed. RESULTS: Depiction and sharpness of intrahepatic vessels were rated significantly better (P < 0.01) using T2w-PACE-TSE compared to T2w-CTSE and T2w-HASTE sequences. Significantly higher contrast values were measured for T2w-PACE-TSE images compared to T2w-CTSE, T2w-HASTE, and T1w-FLASH images (P < 0.01). Mean examination time of the T2w-PACE-TSE was 7.91 minutes, acquisition time of the T2w-CTSE sequence was 4.52 minutes. CONCLUSION: Prospective acquisition correction is an efficient method for reducing respiratory movement artifacts in T2w-TSE imaging of the upper abdomen. Compared to T2w-CTSE and T2w-HASTE sequences recognition of anatomical details and contrast can be significantly improved.

Abdomen↗

Computer-assisted diagnosis of focal liver lesions on CT images evaluation of the Perceptron algorithm.

RATIONALE AND OBJECTIVE: The purpose of the study was to investigate a modified version of a so-called Perceptron algorithm in detecting focal liver lesions on CT scans. MATERIALS AND METHODS: The modified Perceptron algorithm is based on simulated annealing with a logarithmic cooling schedule and was implemented on a standard workstation. The algorithm was trained with 400 normal and 400 pathologic CT scans of the liver. An additional 100 normal and 100 pathologic scans were then used to test the detection of pathology by the algorithm. The total of 1000 scans used in the study were selected from the portal venous phase of upper abdominal CT examinations performed in patients with normal findings or hypovascularized liver lesions. The pathologic scans contained 1 to 4 focal liver lesions. For the preliminary version of the algorithm used in this study, it was necessary to define regions of interest that were converted to a matrix of 119 x 119. RESULTS: Training of the algorithm with 400 examples each of normal and abnormal findings took about 75 hours. Subsequently, the testing took several seconds for processing each scan. The diagnostic accuracy in discriminating scans with and without focal liver lesions achieved for the 200 test scans was approximately 99%. The error rate for pathologic and normal scans was comparable to results reported in the literature, which, however, were obtained for much smaller test sets. CONCLUSION: The modified Perceptron algorithm has an accuracy of close to 99% in detecting pathology on CT scans of the liver showing either normal findings or hypovascularized focal liver lesions.

Algorithms↗

Multislice computed tomography for preoperative evaluation of right ventricular volumes and function: comparison with magnetic resonance imaging.

BACKGROUND: This study was performed to validate preoperative right ventricular measurements obtained from multislice spiral computed tomography data sets in comparison with magnetic resonance imaging. METHODS: Before cardiac surgery, 25 patients (among them 12 patients with compromised right ventricular function) underwent contrast-enhanced retrospectively electrocardiogram-gated multislice spiral computed tomography and cine magnetic resonance imaging in a standardized fashion. Right ventricular end-diastolic, end-systolic and stroke volume, ejection fraction, and myocardial mass were calculated according to the slice summation method. Measurements obtained with both modalities were compared using Pearson's correlation coefficient (r), Student's t test for paired samples, and Bland-Altman analysis. RESULTS: The right ventricle was completely visualized with invariably adequate image quality on all multislice spiral computed tomography and magnetic resonance images. For all measurements a close correlation between multislice spiral computed tomography and magnetic resonance imaging was found (end-diastolic volume, r = 0.93; end-systolic volume, r = 0.95; stroke volume, r = 0.91; ejection fraction, r = 0.96; mass, r = 0.94). Mean values of all measurements did not differ significantly between both modalities, and limits of agreement were in an acceptable range. CONCLUSIONS: When compared with magnetic resonance imaging as a reference method, multislice spiral computed tomography seems to be an accurate and reliable noninvasive technique for evaluating right ventricular measurements.

Adult↗

Uterine arterial embolization with tris-acryl gelatin microspheres: a histopathologic evaluation.

Uterine artery embolization (UAE) as an alternative to surgery for the treatment of uterine fibroids and adenomyosis uteri became increasingly popular. While the clinical success of this new treatment strategy is without doubt, there is still considerable uncertainty with respect to the morphologic changes induced by UAE. In this study, a total of 173 women were treated with UAE using tris-acryl gelatin microspheres (TGMS), a new particulate spherical embolic agent, for either symptomatic adenomyosis or leiomyoma. Surgical specimens of 8 women who underwent subsequent myomectomy or hysterectomy were evaluated by conventional histology and immunohistochemistry. TGMS were readily apparent in both macroscopy and routine histology. In patients with fibroids, TGMS accumulated in medium-sized vessels in the direct tumor vicinity, a minor fraction of particles was detected in the outer half of the myometrium and within leiomyomata. In patients with adenomyosis, a random distribution of TGMS was noted throughout the outer half of the myometrium. Freshly infused particles occluded the respective arteries without a significant tissue reaction. In the course of time, a granulomatous foreign body reaction in the vicinity of particles occurred, eventually followed by complete vessel destruction. Leiomyoma treated with UAE showed either hyaline necrosis, coagulative necrosis, or no change at all. Foci of adenomyosis remained unaltered. In conclusion, after UAE with TGMS, particles were identified predominately but not exclusively at the periphery of fibroids. Pathologists must be aware of the morphologic changes induced by UAE in leiomyoma to avoid misinterpretation of induced tissue alterations as signs of malignant tumor growth.

Adult↗

Digital mammography using iodine-based contrast media: initial clinical experience with dynamic contrast medium enhancement.

PURPOSE: We sought to evaluate the potential of dynamic contrast enhancement after the intravenous administration of an iodine-based contrast medium in full-field digital mammography. MATERIAL AND METHODS: A protocol for image acquisition was established for contrast-enhanced mammography and the mammography unit (Senographe 2000D, GE Healthcare, Buc, France) changed as required. The effect of the protocol parameters on imaging was investigated. Subsequently, 21 patients with 25 suspicious lesions of the breast (10 benign, 1 borderline, and 14 malignant) underwent mammography with administration of an iodine-based contrast medium (Ultravist 370, Schering AG, Berlin, Germany), after approval of ethical committee as well as permission of German federal office for Radiation protection, and informed consent from each patient was obtained. Three sequential digital mammographic images of the respective breast were acquired after administration of the contrast medium at a dose of 1 mL/kg body weight and a flow of 4 mL/s. The postcontrast images were acquired 60, 120, and 180 seconds after administration. Subsequently, the precontrast image was logarithmically subtracted from the postcontrast images. Enhancement of the lesions was measured in absolute terms as well as relative to the enhancement of the glandular tissue. The subtracted images were evaluated for lesion depiction and dynamic contrast enhancement. Lesion-enhancement kinetics were compared with the histologic findings. RESULTS: All malignant lesions were identified on the contrast-enhanced images of digital mammography. Three of the tumors (2 malignant, 1 benign) were detected only by contrast-enhanced mammography and not by standard mammography. Dynamic enhancement curves of benign and malignant tumors in contrast-enhanced mammography look similar to the curves known from gadolinium-enhanced magnetic resonance imaging. Nevertheless differentiation between malignant and benign tumors based on the enhancement patterns cannot be directly taken over from magnetic resonance imaging, as suggested by our initial results. The results are somewhat better when tumor enhancement relative to surrounding glandular tissue is used instead of absolute enhancement. CONCLUSION: The results of this preliminary study suggest that contrast-enhanced digital mammography is a potentially useful tool for the detection and the differentiation of benign and malignant breast lesions.

Animals↗

Dynamic computed tomography of the neonatal lung: volume calculations and validation in an animal model.

PURPOSE: The purpose of this study was to evaluate and validate dynamic volume calculation by respiratory-gated multislice computed tomography (CT) in small neonatal animals. MATERIALS AND METHODS: Six mechanically ventilated newborn piglets were imaged in a multislice CT with 0.5-mm slice thickness (4:16 pitch, 0.5-second rotation time, 120 kV). The respirator was connected to the CT unit for recording the respiratory signal. Simultaneously, tidal volume was measured by the respirator and functional residual capacity (FRC) using a multiple-breath washin-washout technique (MBW) with heptafluoropropane (HFP) as tracer gas. Complete volume datasets were reconstructed throughout the respiratory cycle in increments of 10% using retrospective half-scan gating. All animals were scanned in 3 different ventilator settings. Dynamic lung volumes (tidal volumes) were calculated by means of segmentation of the lung parenchyma during the respiratory cycle using work-in-progress software. RESULTS: The mean (+/-standard deviation) FRC determined by CT was 24.7+/-8.6 mL versus 24.8+/-7.3 mL for the MBW technique. There was no statistically significant difference (P=0.555). Pearson's correlation coefficient showed a strong correlation between the data obtained with CT and that obtained with the MBW technique (r=0.886). After exclusion of one outlier, tidal volumes showed a similar correlation (r=0.837) without significant differences in the mean values (CT: 8.9+/-2.4 mL and respirator: 8.7+/-2.4 mL, P=0.566). CONCLUSION: Dynamic multislice CT with respiratory gating allows for calculation of lung volumes and may be useful for future CT applications in human neonatal lung imaging.

Algorithms↗

Spasmolysis at CT colonography: butyl scopolamine versus glucagon.

PURPOSE: To retrospectively determine if the use of butyl scopolamine or glucagon in the supine patient improves colonic distention and reduces the number of collapsed intestinal segments at computed tomographic (CT) colonography. MATERIALS AND METHODS: This study had institutional review board approval; subject informed consent was not required. CT colonography was performed without the administration of an intravenous spasmolytic in 80 asymptomatic subjects (group 1; 45 women, 35 men; age range, 48-77 years; mean, 61.9 years). These subjects were matched with two groups of 80 subjects who were similar in age but were premedicated with glucagon (group 2; 41 women, 39 men; age range, 43-76 years; mean, 63.1 years) or butyl scopolamine (group 3; 43 women, 37 men; age range, 34-77 years; mean, 63.4 years). All 240 subjects were examined in the supine position with multisection CT and a section thickness of 1 mm after intravenous contrast agent administration and rectal carbon dioxide insufflation. The colon was divided into seven segments, and the colon length, total volume, radial distensibility, and number of non-distended segments were calculated for each subject and compared among the three groups. Statistical analysis was performed with analysis of variance and chi2 testing. RESULTS: Mean bowel length was not significantly different among the groups. Mean colon volumes and radial distensibilities, respectively, were 1.84 L and 3.69 cm in group 1, 2.14 L and 3.98 cm in group 2, and 2.35 L and 4.23 cm in group 3; differences in colon volume and radial distensibility were significant only between group 1 and group 3 (P < .001). At CT colonography, 29 segments in 20 group 1 subjects were collapsed, 23 segments in 12 group 2 subjects were collapsed, and 11 segments in six group 3 subjects were collapsed (P = .016). CONCLUSION: Premedication with butyl scopolamine or, less effectively, glucagon improves colonic distention in the supine subject.

Aged↗

Assessment of mitral valve regurgitation at electron-beam CT: comparison with Doppler echocardiography.

PURPOSE: To prospectively compare mitral valve regurgitation fractions calculated at electron-beam computed tomography (CT) (Doppler echocardiography as reference standard) and to evaluate accuracy of electron-beam CT volume and flow measurements compared with magnetic resonance (MR) imaging results. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. Volume and flow measurements were performed at electron-beam CT in 219 patients (197 men, 22 women; mean age, 61.5 years +/- 10.4 [standard deviation]), of whom 157 had known isolated mitral valve regurgitation. Regurgitation volume was calculated as the difference between left ventricular total and forward stroke volumes. Regurgitation fractions were compared with corresponding echocardiographic grades (grades 0-IV) by using Spearman rank correlation and a weighted kappa test. In 22 patients, CT volume and flow measurements were compared with MR results by using intraclass correlation. RESULTS: Regurgitation fractions at CT correlated well with echocardiographic grading (rank correlation coefficient, r(S) = 0.82; P < .05). Mean regurgitation fractions for echocardiographic grades 0, I, II, III, and IV were 3.1% +/- 6.2, 12.7% +/- 9.9, 25.3% +/- 12.3, 40.4% +/- 11.5, and 55.9% +/- 13.7, respectively. The most suitable thresholds for differentiating echocardiographic grades were calculated regurgitation fractions of 6%, 20%, 30%, and 44%; with these thresholds, individual echocardiographic grades were differentiated (grades 0 vs I-IV, 0-I vs II-IV, 0-II vs III-IV, and 0-III vs IV, respectively) with sensitivities of 89%, 87%, 86%, and 93% and specificities of 81%, 87%, 92%, and 91%, respectively. There was perfect agreement in classification of mitral valve insufficiency between electron-beam CT and echocardiography in 134 (61%) patients and a mismatch by one grade in 72 (33%) and by two grades in 13 (6%) (kappa = 0.84). Intraclass correlation coefficients between CT and MR imaging for total and forward stroke volumes and regurgitation volume and fraction were 0.88, 0.79, 0.93, and 0.89, respectively. CONCLUSION: Electron-beam CT provides quantitative information on severity of mitral valve regurgitation, but semiquantitative classification of regurgitation showed mismatch between electron-beam CT and Doppler echocardiography by at least one grade in more than one-third of all patients.

Adult↗

Value of dual-phase multislice CT prior to minimally invasive therapy of iatrogenic renal injuries.

PURPOSE: To evaluate the diagnostic impact of multislice computed tomography (MSCT) in treatment planning prior to transarterial coil embolization of iatrogenic renal injuries. METHODS: Nine patients (median age 54 years, range 36-66) with iatrogenic renal vascular injury were treated with superselective coil embolization. Prior to therapy, a dual-phase (40 and 120 seconds) contrast-enhanced MSCT was applied in 6 patients. Seven patients underwent renal ultrasonography. Multiplanar reconstructions of the MSCT scans were used to affirm ongoing bleeding and to localize the bleeding site at the level of the segmental or interlobar artery. MSCT and angiographic findings were compared to evaluate the accuracy of MSCT in the detection of the bleeding source prior to therapy. RESULTS: Multiplanar reconstructions of early-phase MSCT scans allowed precise identification of the bleeding interlobar or segmental artery in all 6 cases prior to angiography. In one case, MSCT was even able to detect a source of bleeding that was not revealed by selective renal angiography. CONCLUSIONS: Multiplanar reconstructions of MSCT data demonstrate not only the presence of hematoma but also confirm ongoing bleeding and the location of the feeder artery prior to minimally invasive therapy.

Adult↗

MRI of prostate cancer at 1.5 and 3.0 T: comparison of image quality in tumor detection and staging.

OBJECTIVE: This prospective study was performed to compare the image quality, tumor delineation, and depiction of staging criteria on MRI of prostate cancer at 1.5 and 3.0 T. SUBJECTS AND METHODS: Twenty-four patients with prostate cancer underwent MRI at 1.5 T using the combined endorectal-body phased-array coil and at 3.0 T using the torso phased-array coil, among them 22 before undergoing radical prostatectomy. The prostate was imaged with T2-weighted sequences in axial and coronal orientations at both field strengths and, in addition, with an axial T1-weighted sequence at 1.5 T. Preoperative analysis of all MR images taken together was compared with the histologic findings to determine the accuracy of MRI for the local staging of prostate cancer. In a retroanalysis, the image quality, tumor delineation, and conspicuity of staging criteria were determined separately for both field strengths and compared. Statistical analysis was performed using Wilcoxon's and the McNemar tests. RESULTS: In the preoperative analysis, MRI (at both 1.5 and 3.0 T) had an accuracy of 73% for the local staging of prostate cancer. The retroanalysis yielded significantly better results for 1.5-T MRI with the endorectal-body phased-array coil in terms of image quality (p < 0.001) and tumor delineation (p = 0.012) than for 3.0-T MRI with the torso phased-array coil. Analysis of the individual staging criteria for extracapsular disease did not reveal a superiority of either of the two field strengths in the depiction of any of the criteria. CONCLUSION: Intraindividual comparison shows that image quality and delineation of prostate cancer at 1.5 T with the use of an endorectal coil in a pelvic phased-array is superior to the higher field strength of 3.0 T with a torso phased-array coil alone. As long as no endorectal coil is available for 3-T imaging, imaging at 1.5 T using the combined endorectal-body phased-array coil will continue to be the gold standard for prostate imaging.

Aged↗

MR imaging-guided prostate biopsy with a closed MR unit at 1.5 T: initial results.

The authors evaluated a magnetic resonance (MR) imaging-compatible biopsy device comprising a needle guide that can be visualized with MR imaging and manipulated mechanically from outside the MR unit. With approval from the local ethics committee and patient consent, this device was tested in 12 patients by using a closed 1.5-T MR unit and a body phased-array coil. Patients had elevated prostate-specific antigen levels (6-60 ng/mL) and one or more areas in the prostate that were suspicious for carcinoma at prebiopsy MR imaging. Biopsy was performed with transrectal access and with the patient prone. A 16-gauge MR imaging-compatible needle was successfully positioned with the device, and between six and nine tissue cores were obtained in each patient. In one patient, two suspicious basal areas could not be reached with the device. Histologic analysis showed prostate cancer in five patients and prostatitis in six. No complications were observed. The device enabled MR imaging-guided core-needle biopsy of prostate areas suspicious for cancer on MR images.

Aged↗