Apical tissue tracking echocardiography for characterization of regional left ventricular function: comparison with magnetic resonance imaging in patients after myocardial infarction.

OBJECTIVE: The purpose of this study was to characterize the normal pattern of apical tracking and to investigate whether tissue tracking imaging is more useful for evaluation of regional left-ventricular function than noncontrast harmonic echocardiography in patients after myocardial infarction. BACKGROUND: Left ventricular longitudinal shortening plays an important role in cardiac contraction, and can be evaluated online by a new Doppler tissue imaging method. METHODS: We included 40 healthy participants and 40 patients after myocardial infarction. They underwent tissue tracking imaging and noncontrast harmonic imaging by an experienced and an inexperienced observer. Diagnostic accuracy of semiquantitative evaluation of left ventricular function was compared using magnetic resonance imaging as reference method. RESULTS: Velocity-time integrals decreased from basal to apical segments in healthy participants. Tissue tracking imaging has a higher diagnostic sensitivity than noncontrast imaging for the diagnosis of regional wall-motion abnormalities (expert, 78% vs 97%, P <.01; beginner, 63% vs 91%, P <.001), whereas specificity remained unchanged (expert, 99% vs 97%, not significant; beginner, 91% vs 92%, not significant). CONCLUSIONS: Tissue tracking imaging is feasible and evaluates regional systolic myocardial function quantitatively with high diagnostic accuracy compared with magnetic resonance imaging in patients after myocardial infarction, and is more accurate than noncontrast harmonic echocardiography.

Aged↗

Disintegration and stepwise expulsion of a large uterine leiomyoma with restoration of the uterine architecture after successful uterine fibroid embolization: case report.

Uterine fibroid embolization (UFE) is a new minimally-invasive treatment option for leiomyomata of the uterus leading to symptomatic improvement and shrinkage of the fibroids. We present a case of restoration of the uterine architecture after disintegration and stepwise expulsion of infarcted leiomyoma tissue 7 months after UFE for leiomyoma-related menorrhagia.

Embolization, Therapeutic↗

A vascular stent as an active component for locally enhanced magnetic resonance imaging: initial in vivo imaging results after catheter-guided placement in rabbits.

RATIONALE AND OBJECTIVE: A vascular stent constructed as a high frequency resonator improves the local signal-to-noise ratio at magnetic resonance (MR) imaging. After catheter placement and intravascular expansion, the stent can be used as an inductively coupled coil for MRI. The imaging properties of this balloon-expandable active MRI stent (AMRIS) were evaluated after x-ray fluoroscopy guided placement in the abdominal aorta of five rabbits using MR angiography (MRA) and flow measurements. METHODS: The AMRIS was implanted in the abdominal aorta of five rabbits using a balloon catheter inserted through the common carotid artery. The rabbits were examined by MRA (3D fast low-angle shot) at 1.5 tesla before and after intravenous injection of an iron-oxide-based blood pool contrast medium (dose 50 micro mol Fe/kg) and flow measurements (ECG-triggered phase contrast cine gradient-echo sequence). Signal-to-noise ratios (SNR) were calculated and flow volume curves were generated. The in-stent increase in temperature was measured in vitro using a fiberoptic thermometry system. RESULTS: The SNR was 5.0 +/- 0.6 outside the stent and 23.2 +/- 14.1 within the stent ( < 0.0 5) in plain MRA, 19.5 +/- 5.0 outside and 30.7 +/- 8.2 within the stent ( < 0.05) in contrast enhanced MRA, and 5.8 +/- 1.6 and 13.9 +/- 5.9, respectively ( < 0.05) in the magnitude images of the flow measurements. Flow volume curves within and distal to the stent were comparable. CONCLUSIONS: The expandable active MRI stent produces local signal enhancement in MRA and MR flow measurements after catheter placement and thus may improve assessment of the stented vessel segment by MR imaging.

Animals↗

Gadobenate dimeglumine-enhanced magnetic resonance angiography of the pelvic arteries.

RATIONALE AND OBJECTIVES: To evaluate 4 doses of gadobenate dimeglumine (Gd-BOPTA) for contrast-enhanced magnetic resonance angiography (CE-MRA) of the pelvic arteries and to compare CE-MRA with unenhanced time-of-flight MRA (2D-TOF-MRA). METHODS: A multicenter Phase II dose-finding study was performed in 136 patients with Gd-BOPTA doses of 0.025, 0.05, 0.1, and 0.2 mmol/kg bodyweight. Evaluation of CE-MRA images and comparison with 2D-TOF-MRA images was performed onsite and by 2 blinded offsite reviewers in terms of subjective image quality, number of lesions detected, and confidence in lesion characterization. RESULTS: Significant (P < 0.05) improvements over unenhanced findings were observed for CE-MRA at all dose levels. For reviewer 1 and the onsite investigators, the overall image quality increased up to a dose of 0.1 mmol/kg and then plateaued. For reviewer 2, increased image quality was noted up to a dose of 0.2 mmol/kg. Significant (P < 0.005) increases in diagnostic confidence on CE-MRA versus unenhanced MRA was observed for all dose groups by reviewer 1 and the onsite investigators and for the 0.1 and 0.2 mmol/kg dose groups by reviewer 2. No serious adverse events were recorded that were attributable to the study drug and no trends in laboratory parameters, vital signs, or electrocardiogram recordings were observed. CONCLUSIONS: Gadobenate dimeglumine-enhanced MRA is safe and significantly more effective than unenhanced 2D-TOF-MRA for imaging the pelvic arteries. A dose of 0.1 mmol/kg appears the most appropriate dose for subsequent Phase III clinical evaluation.

Adolescent↗

New contrast media designed for x-ray energy subtraction imaging in digital mammography.

RATIONALE AND OBJECTIVES: In contrast-enhanced dual-energy subtraction imaging 2 images acquired postcontrast media administration at different energies are subtracted to highlight structures hidden in the absence of contrast media. X-ray spectra of the newly developed digital full-field mammography units (GE Senographe 2000 D) are dominated by the emission lines of the Mo or Rh anodes. The K-edge of Zirconium (Zr) is flanked by these 2 emission lines. Thus, the attenuation of Zr should experience a pronounced change of attenuation in parallel with a change of anodes. Under clinically relevant conditions, the contrasting behavior of Zr should be compared with that of other elements having K-edge energies outside the window spanned by the 2 anode emission lines. METHODS: Solutions containing the contrasting elements Br, Y, Zr, I, and Gd were investigated for dual-energy subtraction in digital mammography with the 2 anode/filter settings (Mo/Mo and Rh/Rh). These solutions were investigated in phantom studies in the energy range conventionally used in mammography. Additionally, the contrasting behavior of Zr and I was compared in an in vivo study in rats. RESULTS: The sweeping over the K-edge by alternating between the Mo and Rh anodes increases the detection of Zr in energy subtraction imaging at constant high voltage. This procedure does not lead to sufficient contrast enhancement for iodine-based contrast media which become detectable by increasing the high voltage to 40-49 kV. CONCLUSION: The instrumental and physical data outlined predestine Zr as contrasting element with a high potential for energy subtraction imaging in digital mammography in the energy range conventionally applied.

Animals↗

Gadobenate dimeglumine-enhanced MRI of the breast: analysis of dose response and comparison with gadopentetate dimeglumine.

OBJECTIVE: The purpose of this study was to evaluate the clinical efficacy and dose response relationship of three doses of gadobenate dimeglumine for MRI of the breast and to compare the results with those obtained after a dose of 0.1 mmol/kg of body weight of gadopentetate dimeglumine. SUBJECTS AND METHODS. Gadobenate dimeglumine at 0.05, 0.1, or 0.2 mmol/kg of body weight or gadopentetate dimeglumine at 0.1 mmol/kg of body weight was administered by IV bolus injection to 189 patients with known or suspected breast cancer. Coronal three-dimensional T1-weighted gradient-echo images were acquired before and at 0, 2, 4, 6, and 8 min after the administration of the dose. Images were evaluated for lesion presence, location, size, morphology, enhancement pattern, conspicuity, and type. Lesion signal intensity-time curves were acquired, and lesion matching with on-site final diagnosis was performed. A determination of global lesion detection from unenhanced to contrast-enhanced and combined images was performed, and evaluations were made of the diagnostic accuracy for lesion detection and characterization. A full safety evaluation was conducted. RESULTS: Significant dose-related increases in global lesion detection were noted for patients who received gadobenate dimeglumine (p < 0.04, all evaluations). The sensitivity for detection was comparable for 0.1 and 0.2 mmol/kg of gadobenate dimeglumine, and specificity was highest with the 0.1 mmol/kg dose. Higher detection scores and higher sensitivity values for lesion characterization were found for 0.1 mmol/kg of gadobenate dimeglumine compared with 0.1 mmol/kg of gadopentetate dimeglumine, although more variable specificity values were obtained. No differences in safety were observed, and no serious adverse events were reported. CONCLUSION: Gadobenate dimeglumine is a capable diagnostic agent for MRI of the breast. Although preliminary, our results suggest that 0.1 mmol/kg of gadobenate dimeglumine may offer advantages over doses of 0.05 and 0.2 mmol/kg of gadobenate dimeglumine and 0.1 mmol/kg of gadopentetate dimeglumine for breast lesion detection and characterization.

Adult↗

Effect of partial left ventriculectomy on left and right ventricular volumes and function as assessed with electron beam tomography: preliminary results.

Our objective was to determine if left ventricular reduction surgery affects left and right ventricular volumes and function. Twenty-three patients with end-stage heart failure underwent contrast-enhanced electron beam tomographic function studies before and twice after partial left ventriculectomy (PLV). The PLV was combined with other cardiosurgical procedures in 20 of 23 patients. Left and right ventricular enddiastolic volume (LVEDV, RVEDV), stroke volume (LVSV, RVSV), ejection fraction (LVEF, RVEF), and enddiastolic diameter (LVEDD, RVEDD) were determined by manual tracing of endo- and epicardial borders at enddiastole and endsystole. Patients were scanned 31 days (+/-34) before and 18 days (+/-13) and 8 months (+/-4) after PLV. Mean pre- and early and late postoperative values for LVEDV, LVSV, LVEF, and LVEDD were 387.9 ml (+/-125.5 ml), 255.6 ml (+/-79.3 ml; p<0.01), and 253.7 ml (+/-97.8 ml; p<0.05), 79.7 ml (+/-25.2 ml), 74.8 ml (+/-17.9; n.s.), and 79.1 ml (+/-26.5 ml; n.s.), 21.6% (+/-7.3%), 31.9% (+/-13.4%; p<0.05), and 34.1% (+/-14.1%; p<0.05), and 72.0 mm (+/-10.6 mm), 64.3 mm (+/-8.5 mm; p<0.05), and 63.5 mm (+/-9.4 mm; p<0.05), respectively. Mean pre- and postoperative values for RVEDV, RVSV, RVEF, and RVEDD were 177.7 ml (+/-72.8 ml), 172.4 ml (+/-59.2 ml; n.s.), and 178.9 ml (+/-60.8 ml; n.s.), 60.3 ml (+/-21.6 ml), 68.8 ml (+/-19.9 ml; n.s.), and 78.3 ml (+/-25.3 ml; n.s.), 38.1% (+/-15.4%), 43.7% (+/-16.3%; p<0.05), and 45.1% (+/-11.2%; n.s.), and 50.4 mm (+/-10.9 mm), 48.1 mm (+/-8.7 mm; n.s.), and 48.5 mm (+/-9.8 mm; n.s.), respectively. The PLV may induce a significant early reduction of left ventricular volumes and improvement of biventricular function; however, our results must be judged carefully as the majority of patients in this study underwent additional cardiosurgical procedures, the contributory effect of which on the overall outcome remains unclear.

Aged↗

Low-dose CT of the paranasal sinuses with eye lens protection: effect on image quality and radiation dose.

The purpose of the study was to assess the effect of lens protection on image quality and radiation dose to the eye lenses in CT of the paranasal sinuses. In 127 patients referred to rule out sinusitis, an axial spiral CT with a lens protection placed on the patients eyes was obtained (1.5/2/1, 50 mAs, 120 kV). Coronal views were reconstructed at 5-mm interval. To quantify a subjective impression of image quality, three regions of interest within the eyeball were plotted along a line perpendicular to the protection at 2, 5, and 9 mm beneath skin level on the axial images. Additionally, dose reduction of a bismuth-containing latex shield was measured using a film-dosimetry technique. The average eyeball density was 17.97 HU (SD 3.7 HU). The relative increase in CT density was 180.6 (17.7), 103.3 (11.7), and 53.6 HU (9.2), respectively. There was no diagnostic information loss on axial and coronal views observed. Artifacts were practically invisible on images viewed in a bone window/level setting. The use of the shield reduced skin radiation from 7.5 to 4.5 mGy. The utilization of a radioprotection to the eye lenses in paranasal CT is a suitable and effective means of reducing skin radiation by 40%.

Artifacts↗

Monomer-coated very small superparamagnetic iron oxide particles as contrast medium for magnetic resonance imaging: preclinical in vivo characterization.

RATIONALE AND OBJECTIVES: Preclinical in-vivo characterization of a newly developed MR contrast medium consisting of very small superparamagnetic iron oxide particles (VSOP) coated with citrate (VSOP-C184). METHODS: VSOP-C184 (core diameter: 4 nm; total diameter: 8.6 nm; relaxivities in water at 0.94 T (T1) 20.1 and (T2) 37.1 l/[mmol*sec]) was investigated to determine its pharmacokinetics, efficacy, acute single dose toxicity, repeated dose toxicity, and genotoxicity. RESULTS: The plasma elimination half-life at 0.045 mmol Fe/kg was 21.3 +/- 5.5 minutes in rats and 36.1 +/- 4.2 minutes in pigs, resulting in a T1-relaxation time of plasma of < 100 milliseconds for 30 minutes in pigs. The particles are mainly cleared via the phagocytosing system of the liver. MR angiography at a dose of 0.045 mmol Fe/kg shows an excellent depiction of the thoracic and abdominal vasculature in rats and of the coronary arteries in pigs. The LD50 in mice is > 17.9 mmol Fe/kg. A good tolerance and safety profile was found. CONCLUSIONS: The experiments indicate, that VSOP-C184 may be a well tolerated and safe contrast medium for MR imaging that can be effectively used for MR angiography including visualization of the coronary arteries.

Animals↗

Coronary MR angiography: experimental results with a monomer-stabilized blood pool contrast medium.

PURPOSE: To evaluate the signal-enhancing characteristics of monomer-coated very small superparamagnetic iron oxide (SPIO) particles used as a blood pool contrast medium for magnetic resonance (MR) angiography in the coronary arteries. MATERIALS AND METHODS: The particles used in this study were coated with citrate as the monomer (VSOP-C91). The particles have a total diameter of 7 nm and show the following relaxivities at 0.47 T: T1, 19 L/mmol. sec(-1); T2, 29 L/mmol. sec(-1). Fifteen cardiac MR examinations were performed at 1.5 T in five pigs. Images were acquired from immediately to 35 minutes (equilibrium phase) after intravenous injection of gadopentetate dimeglumine, gadobenate dimeglumine, and the very small SPIO particles (n = 5 for each substance). RESULTS: Immediately after administration of gadopentetate dimeglumine, gadobenate dimeglumine, and the very small SPIO particles, respectively, increases in the signal-to-noise ratio in blood were 94%, 103%, and 102% and in myocardium were 83%, 83%, and 29% (P <.05, very small SPIO particles versus the low-molecular-weight gadolinium-based compounds). Differences in the blood-to-myocardium contrast-to-noise ratio and visualization of the coronary arteries and their branches were also significant. CONCLUSION: VSOP-C91 significantly improves visualization of the coronary arteries at MR angiography from immediately to 35 minutes after injection.

Analysis of Variance↗

Patients with a history of elevated prostate-specific antigen levels and negative transrectal US-guided quadrant or sextant biopsy results: value of MR imaging.

PURPOSE: To determine the role of magnetic resonance (MR) imaging performed with a combined endorectal body phased-array coil for patients with elevated prostate-specific antigen (PSA) levels or suspicious free-to-total PSA ratios in whom prior transrectal ultrasonographically (US) guided biopsy findings were negative for prostate cancer. MATERIALS AND METHODS: Forty-four patients with PSA levels greater than 4 ng/mL or free-to-total PSA ratios lower than 15% but negative biopsy findings were examined with T1- and T2-weighted MR imaging at 1.5 T with a combined endorectal body phased-array coil. All patients underwent digital rectal examination (DRE) and transrectal US. Thirty-eight patients underwent repeat biopsy after MR imaging. The accuracy of MR imaging for detection of prostate cancer was assessed prospectively. Retrospectively, MR imaging findings were correlated with individual biopsy site findings. MR imaging and biopsy results were correlated by using a cross table to calculate sensitivity, specificity, and positive predictive value (PPV). Retrospective analysis results were evaluated with receiver operating characteristic analysis. A P value of less than.05 indicated significance (chi(2) test according to Pearson). RESULTS: At prospective analysis, MR imaging had a sensitivity of 83% and a PPV of 50% for detection of prostate cancer; these values were 33% and 67%, respectively, for DRE and 33% and 57%, respectively, for transrectal US. At retrospective site-by-site analysis, MR imaging results did not correlate significantly with individual biopsy site findings (P =.126); sensitivity was 65% and PPV was 12%. CONCLUSION: In this patient population, MR imaging has higher sensitivity for detection of prostate cancer than DRE or transrectal US.

Aged↗

Gadobenate dimeglumine-enhanced MR angiography of the abdominal aorta and renal arteries.

OBJECTIVE: This study was conducted to determine the efficacy and safety of four different doses of gadobenate dimeglumine for contrast-enhanced three-dimensional MR angiography of the abdominal aorta and renal arteries. SUBJECTS AND METHODS: Ninety-four patients with suspected abnormality of the abdominal aorta or renal arteries underwent unenhanced three-dimensional gradient-recalled echo time-of-flight MR angiography and contrast-enhanced MR angiography after the IV injection of one of four doses of gadobenate dimeglumine (0.025, 0.05, 0.1, and 0.2 mmol/kg of body weight). Efficacy was assessed on-site and by two blinded off-site reviewers in terms of change in total diagnostic quality score and diagnostic quality score per vessel segment from baseline unenhanced time-of-flight MR angiography to contrast-enhanced MR angiography. Secondary efficacy end points included lesion count and level of confidence in lesion characterization. Safety assessments comprised adverse event monitoring, physical evaluation, vital signs, ECG, and laboratory investigations. RESULTS: A significant change in the total diagnostic quality score from unenhanced to contrast-enhanced MR angiography was observed at all doses. The change increased with increased dose, plateauing at the 0.1 mmol/kg dose level. More patients with lesions detected and increased reviewer confidence for lesion characterization were noted on contrast-enhanced MR angiography compared with unenhanced MR angiography, although no dose-related trends were observed. All doses were well tolerated, and no significant changes in safety parameters were observed. CONCLUSION: Gadobenate dimeglumine is an effective and safe agent for contrast-enhanced MR angiography of the abdominal aorta and renal arteries. A dose of 0.1 mmol/kg of body weight appears to be the most suitable.

Adult↗

Behaviour of implantable coronary stents during magnetic resonance imaging.

BACKGROUND: Magnetic resonance imaging (MRI) becomes more and more a routine diagnostic tool in clinical cardiology. In patients undergoing MRI, metallic implants may be harmful by motion or heating under certain circumstances. Many cardiac patients have implanted intracoronary stents. However, the safety of these metallic implants and especially their temperature behaviour during MRI has not been sufficiently tested. METHODS: This study investigated motion and temperature changes of 14 different stents for intracoronary application in two clinical scanners at field strengths of 1.0 and 1.5 T. At 1.5 T these studies were repeated after implantation of the stents into the coronary arteries of excised porcine hearts. Furthermore, the clinical status of 33 patients was assessed after a cardiac MR study and compared with a group of 33 patients matched for age, sex and risk factors for restenosis. RESULTS: No visible motion of the stents was observed. Furthermore, using a highly sensitive infrared camera any significant heating of the stents during MRI could be excluded. The rate of clinical events was not different in patients after MRI as compared with the control group. CONCLUSION: It is concluded that MRI is safe in patients with the currently available intracoronary stents.

Journal Article↗

Use of the 4F Rösch inferior mesenteric catheter in embolization procedures in the pelvis: a review of 300 cases.

The aim of this study is to evaluate the use of a 4F Rösch inferior mesenteric (RIM) catheter for pelvic embolization procedures. Between October 2000 and January 2006, 364 patients (357 female, 7 male; age: 23-67 years) underwent embolization of various pathologies [uterine fibroids (n = 324), pure adenomyosis of the uterus (n = 19), postpartum hemorrhage (n =1), traumatic or postoperative hemorrhage (n = 9), bleeding related to cervical cancer (n =7), AV malformation of the uterus (n = 2) and high-flow priapism (n = 2)] at a single institution. In all cases, bilateral catheterization was primarily attempted with the use of a 4F hook-shaped braided endhole catheter (Rösch-Inferior-Mesenteric, RIM-Catheter, Cordis, Miami, FL). Frequency of initial failure to catheterize the vascular territory of interest and carry out the embolization were recorded and the types of difficulty encountered were noted. Catheterization of the main stem of the vessel territory of interest with the use of a unilateral femoral approach and the 4F RIM catheter was successful in 334/364 (91.8%) the embolization cases. Bilateral catheterization of the internal iliac arteries using a single common femoral artery access and the 4F RIM catheter was achieved in 322/364 (88.5%) patients. In 12/364 (3.3%) patients, a contralateral puncture was performed and the same 4F catheter was used. In 28/364 (7.7%) cases the 4F RIM catheter was exchanged for a catheter with a cobra-shaped or sidewinder configuration. The 4F RIM catheter is a simple and valuable alternative to catheters and techniques commonly employed for pelvic artery embolization.

Adult↗

Electron beam tomography of interpulmonary saddle embolism: extent and vascular distribution.

PURPOSE: The purpose of this work was to assess morphology and secondary signs of interpulmonary emboli extending across the bifurcation of the main pulmonary artery (PA). METHOD: Retrospective evaluation of 780 electron beam tomographic studies of the chest yielded 17 cases of interpulmonary saddle embolism. Length, diameter, vascular distribution of the emboli, and secondary findings were prospectively assessed by two blinded reviewers. Follow-up studies were carried out in 12 of 17 patients (71%). RESULT: Mean total length of the emboli was 46.6 cm (range 20.9-81.5 cm). The mean diameter of the saddle embolus was significantly smaller at the level of the bifurcation than in the left or right PA (4.5, 7.7, and 7.4 mm, respectively; p < 0.01). Dilatation of the right heart was found in 10 of 17 cases (59%). At follow-up, the saddle state was no longer present in 8 of 12 patients (67%). CONCLUSION: Interpulmonary saddle emboli appear to be a transient form of acute pulmonary embolism, the site of predilection for rupture of the embolus being the level of the bifurcation. Their frequency may therefore be underestimated.

Acute Disease↗

Quantification of mitral valve regurgitation by left ventricular volume and flow measurements using electron beam computed tomography: comparison with magnetic resonance imaging.

PURPOSE: This study was designed to evaluate electron beam computed tomography (CT) for quantifying mitral regurgitation in comparison with magnetic resonance (MR) imaging as a reference method. METHOD: Forty-three patients, among them 33 with known mitral regurgitation, underwent electron beam CT and MR imaging. Total left ventricular stroke volume (TSV), antegrade stroke volume (ASV), and mitral regurgitation volume (MRV) and fraction (MRF) were determined and compared between the two modalities. Additionally electron beam CT measurements were compared with the corresponding echocardiographic findings. RESULTS: Significant differences between electron beam CT and MR imaging were found for measurements of TSV and MSV but not for ASV and MRF. There was a close linear correlation between both modalities for all parameters. Furthermore, there was good agreement between electron beam CT and echocardiography, although electron beam CT shows a tendency to overestimate mitral regurgitation slightly. CONCLUSION: The results indicate that electron beam CT offers an additional procedure for quantifying mitral regurgitation and that it may be used as an alternative to MR imaging.

Echocardiography, Doppler, Color↗