Search PubMed⌕ Search

Biomedical subjects

A Caprihan

Publications and source records attributed to A Caprihan.

28 records · Page 2Linked to original sources

A new method for flow velocity measurement: frequency encoded NMR.

We demonstrate a new rapid NMR method to measure the average velocity and the velocity distribution of a flowing fluid. We use a truncated Carr-Purcel-Meiboom-Gill pulse sequence, pi/2-T-pi-2T-pi-T-echo, in the presence of a static magnetic field gradient. The pi/2 pulse is selective and tags a narrow slice of nuclei. The second echo from the tagged nuclei is Fourier transformed after the nuclei have evolved for a time 4T to give the velocity distribution modified by the initial slice selection profile. In this way, average velocities up to 54 cm/s were measured for water flowing in a plastic tube with either a plug or a developed velocity distribution. Each measurement required about 20 ms but this could be reduced with larger field gradients. Thus, this method is fast enough to apply to such problems as measuring pulsatile flow in arteries.

Animals↗

Beat-by-beat stroke volume assessment by pulsed Doppler in upright and supine exercise.

A 3.0 MHz pulsed Doppler echocardiography was used to estimate instantaneous stroke volume (SV) and cardiac output (Q) in eight men during steady-state supine (S) and upright (U) exercise at 300 kpm/min. The mean transients in heart rate (HR), SV, and Q for the first 20 s of exercise in each posture were then determined. Center-line blood velocities were obtained in the ascending aorta with the transducer positioned manually in the suprasternal notch. Mean supine values for SV and Q at rest and exercise were 111 ml and 6.4 1/min and 112 ml and 9.71/min, respectively. The corresponding results for U were 76 ml and 5.61/min and 92 ml and 8.41/min, respectively. These values compare favorably with previous studies utilizing invasive procedures. The transient response of Q following the onset of exercise in U was about twice as fast as in S because of the rapid and almost immediate upsurge in SV. In S, only HR served to augment Q, as SV initially fell. The faster rise in aortic flow in U with exercise represented an additional volume (184 ml) of blood passing through the aorta compared with S in the first 20s. This must be related to the rapid mobilization of pooled venous blood from the leg veins during U.

Adult↗

Characterization of partially sintered ceramic powder compacts using fluorinated gas NMR imaging.

We use nuclear magnetic resonance (NMR) imaging of C2F6 gas to characterize porosity, mean pore size, and permeability of partially sintered ceramic (Y-TZP Yttria-stabilized tetragonal-zirconia polycrystal) samples. Conventional measurements of these parameters gave porosity values from 0.18 to 0.4, mean pore sizes from 10 nm to 40 nm, and permeability from 4 nm(2) to 25 nm(2). The NMR methods are based on relaxation time measurements (T(1)) and the time dependent diffusion coefficient D(Delta). The relaxation time of C2F6 gas is longer in pores than in bulk gas and it increases as the pore sizes decrease. NMR yielded accurate porosity values after correcting for surface adsorption effects. A model for T(1) dependence on pore size that accounts for collisions between gas molecules and walls as well as surface adsorption effects is proposed. The model fits the experimental data well. Finally, the long time limit of D(Delta)/D(o), where D(o) is the bulk gas diffusion coefficient is useful for measuring tortuosity, while the short time limit was not achieved experimentally and could not be used for calculating surface-area to volume (S/V) ratios.

Ceramics↗