Search PubMedSearch

SEARCH · Search PubMed

Results for “stage-two implant surgery”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

802 recordsLinked to original sources

The use of diode laser and scalpel blade in stage-two dental implant surgery: a comparative study.

OBJECTIVE: The use of lasers in dental implant procedures raises questions regarding the preservation of keratinized tissues and implant outcomes. This study aimed to compare the clinical effects (pain and impression time) and soft tissue healing (keratinization, peri-implant probing, bleeding, and healing) of diode lasers and scalpels used during stage-two dental implant surgery. METHOD AND MATERIALS: A prospective randomized clinical trial with a 1:1 allocation ratio was conducted. The study included 30 patients, each with a single, fully osseointegrated implant. Patients were categorized into two groups. The study group underwent stage-two implant surgery using a 970-nm diode laser. In the control group, implants were exposed using a conventional surgical blade. A comparison between the diode laser and conventional scalpel groups was made based on clinical outcomes (pain and impression time) and soft tissue healing (keratinization, peri-implant probing, bleeding, and healing). Data were analyzed using a paired t test. RESULTS: Pain intensity significantly decreased from immediate postoperative to 7 days in both scalpel (49.87 ± 6.78, t = 28.48, df = 14, P .001) and diode laser (7.67 ± 7.58, t = 3.91, df = 14, P = .002) groups. Immediately after surgery, pain scores were significantly higher in the scalpel group compared with the diode laser group (94.53 ± 4.45 vs 46.93 ± 5.85, t = 25.076, df = 26.151, P .001). Although pain decreased in both groups by day 7, the scalpel group continued to exhibit significantly greater pain (44.67 ± 5.96 vs 39.27 ± 3.73, t = 2.974, df = 23.513, P = .007). Impression time (P = .231) and gingival keratinized tissue (P = .736) did not differ significantly between the scalpel and diode laser approaches. At week 6, the scalpel group exhibited a significantly higher mean peri-implant bleeding index (2.60 ± 0.507) compared with the laser group (0.07 ± 0.258, P .001). However, after 12 weeks, no significant difference was observed (1.58 ± 0.19 vs 1.55 ± 0.21, P = .748). Laser surgery produced significantly better early wound healing at all intervals (P .001), while intraoperative bleeding was more common with the scalpel technique than with the diode laser (100.0% vs 66.7%, P = .042). CONCLUSION: Compared with the scalpel method, the diode laser method resulted in a significant reduction in pain intensity, improved wound healing, and less peri-implant bleeding during the stage-two dental implant surgery.

Humans

Aortoesophageal Fistula: Mending the Lethal Connection-A Systematic Review and Meta-Analysis.

BACKGROUND: Aortoesophageal fistula (AEF) is a rare, life-threatening condition with limited high-quality evidence to guide management. METHODS: We conducted a systematic review and meta-analysis of PubMed and Scopus through December 2025, evaluating survival and complication outcomes according to treatment strategy and morphological severity. Patients were categorized into 5 groups: TEVAR alone, staged TEVAR followed by surgery, primary open or hybrid surgery, TEVAR with esophageal stenting, and supportive/palliative care. Outcomes were pooled as proportions with 95% confidence intervals (CIs). RESULTS: A total of 167 reports representing 528 patients were included. Overall 30-day mortality was 31.2% (95% CI 27.0% to 35.7%) and 1-year mortality 41.2% (95% CI 36.2% to 46.4%). Infection occurred in 32.6%, reintervention in 20.2%, and recurrence in 13.2%. Staged TEVAR followed by surgery showed favorable survival (30-day 12.7%, 1-year 26.1%) but high infection (66.7%) and reintervention (43.2%) rates. TEVAR with esophageal stenting had the lowest early mortality (5.0%) but frequent reintervention (54.5%) and 1-year mortality of 33.3%. TEVAR alone demonstrated the lowest 1-year mortality among definitive strategies (25.5%) but notable recurrence (26.9%). Primary open or hybrid surgery carried higher early and late mortality, while supportive/palliative care had the worst outcomes. Morphological severity correlated strongly with mortality, infection, reintervention, and recurrence, with type IV lesions showing particularly poor prognosis. CONCLUSION: Despite contemporary management, AEF carries high early and late mortality. Definitive strategies, particularly staged TEVAR followed by surgery, offer improved survival but increased complications. Morphology-guided, individualized management is recommended.

Adult

Bioabsorbable vs. titanium screws in first metatarsophalangeal joint arthrodesis: a pilot randomized controlled trial with 2-year follow-up.

INTRODUCTION: To assess the feasibility and preliminary clinical outcomes of bioabsorbable screw fixation in first metatarsophalangeal joint arthrodesis compared to conventional titanium screw fixation. METHODS: In this prospective pilot randomized controlled trial, 30 patients were allocated 1:1 to bioabsorbable or titanium cannulated lag screw fixation. Arthrodesis was performed using a cup-and-cone technique at two Finnish hospitals. Full weight-bearing in an orthopaedic shoe was allowed after six weeks. Outcomes included AOFAS and VA-FAS FA-VAS scores, union rates, and complications assessed at 3, 6, 12, and 24 months. RESULTS: Both groups showed significant functional improvement with no between-group differences. At 24 months, mean AOFAS scores were 89.1 (SD 2.7) in the titanium group and 90.0 (SD 0.0) in the bioabsorbable group (p = 0.23). Mean FA-VAS total scores (sum of pain, function, and complaints subscales) were 1948 (SE 59.4) in the titanium group and 1914 (SE 61.4) in the bioabsorbable group (p = 0.655). Union rate was 90% overall; nonunion occurred in one titanium and two bioabsorbable patients, all requiring revision. No implant-related complications or hardware removal surgeries were recorded. Degradation of bioabsorbable screws caused no adverse clinical or radiographic reactions. CONCLUSIONS: Bioabsorbable screws appear safe and feasible in first metatarsophalangeal joint arthrodesis, with preliminary outcomes comparable to titanium fixation. These findings support the conduct of a larger confirmatory trial. TRIAL REGISTRATION: ClinicalTrials.gov, NCT03133039, registered 28 April 2017. https://clinicaltrials.gov/ct2/show/NCT03133039.

Humans

Evaluation of intravenous sedation in dental implant surgeries: A prospective cohort study.

PURPOSE: This study aimed to evaluate the impact of intravenous sedation on patient-centered outcomes during implant and bone augmentation surgeries. METHOD: A prospective observational cohort study included 40 patients undergoing placement of &#x2265;3 implants, with or without bone augmentation. Patients underwent surgery under either intravenous sedation (n = 20) or local anesthesia alone (n = 20), according to routine clinical decision-making and patient preference. The sedation group received intravenous sedation with a multimodal regimen comprising remimazolam, dexmedetomidine, alfentanil, and low-dose esketamine, whereas the control group received local anesthesia only. Patient-reported outcome measures, hemodynamic parameters (SBP, DBP, HR, SpO2), postoperative pain (0-10 scale), and OHRQoL (OHIP-14) were recorded from baseline through 7 days post-surgery. RESULTS: Intravenous sedation was associated with significantly lower intraoperative pain (0.5 [IQR: 0&#x223c;2.75] vs. 3.25 &#xb1; 2.40, p = 0.003), anxiety (1 [IQR: 0&#x223c;2.75] vs. 4 [IQR: 3&#x223c;6], p = 0.001), and experienced discomfort (2 [IQR: 1&#x223c;3.75] vs. 4.15 &#xb1; 2.16, p = 0.016), and shortened perceived treatment duration (2.90 &#xb1; 2.34 vs. 5 [IQR: 4&#x223c;5], p = 0.020). Early postoperative pain was lower in the sedation group from Days 1-4 (p = 0.003-0.010). Hemodynamic parameters were more stable under sedation, with lower SBP (116.42 &#xb1; 13.32 vs. 144.11 &#xb1; 17.42 mmHg, p < 0.001), DBP (73.21 &#xb1; 10.28 vs. 82.37 &#xb1; 11.03 mmHg, p = 0.012), and HR (71.00 [IQR: 62.50&#x223c;79.25] vs. 85.00 &#xb1; 10.72 bpm, p = 0.021). OHRQoL scores favored the sedation group in swallowing, diet, malaise, and daily activities, particularly during the first three postoperative days (p=0.006-0.040). CONCLUSION: Intravenous sedation may enhance the patient experience during implant and/or bone augmentation procedures by reducing intraoperative pain and anxiety, improving hemodynamic stability, and promoting better early-postoperative recovery and OHRQoL. These findings suggest that intravenous sedation provides a safe and effective alternative for implant dentistry surgery, particularly for anxious or pain-sensitive individuals.

Humans

Risk Factors and Predictive Model for Postoperative High Myopia in Children Undergoing Congenital Cataract Surgery With Intraocular Lens Implantation.

PURPOSE: To identify risk factors associated with the development of high myopia following congenital cataract surgery and to establish a robust predictive model. DESIGN: Retrospective clinical cohort study. SUBJECTS: This retrospective study included 106 pediatric patients who underwent congenital cataract surgery with primary IOL implantation (mean follow-up 8.19 years). The model was externally validated in an independent cohort of 72 patients with a mean follow-up of 7.83 years. METHODS: Preoperative and postoperative ocular biometric parameters were collected. Risk factors for postoperative high myopia were analyzed using Cox proportional hazards regression, which served as the basis for model construction. The predictive performance of the model was rigorously evaluated for discrimination and calibration. Discriminative ability was quantified using Harrell's C-index and the area under the receiver operating characteristic curve (AUC). Model calibration was assessed via calibration plots by comparing predicted probabilities with actual observed outcomes. Internal validation was performed using a bootstrapping method (500 iterations) to ensure model stability and adjust for potential overfitting. RESULTS: An initial postoperative refraction of <+0.75D, and a higher IOL Power to Axial length Ratio (IOL/AL ratio) were identified as significant risk factors for the development of postoperative high myopia. Shorter preoperative axial length was associated with a greater magnitude of postoperative myopic shift. The predictive model demonstrated robust performance, achieving a C-index of 0.711 (internal validation C-index: 0.713). The area under the receiver operating characteristic curve (AUC) values for predicting high myopia at 5 and 10 years were 0.858 and 0.745, respectively. Furthermore, calibration curves demonstrated excellent agreement between the predicted and observed outcomes throughout the follow-up period. In external validation, the model achieved a C-index of 0.825, 5-year AUC of 0.833, and 10-year AUC of 0.713. CONCLUSIONS: Our analysis established that initial postoperative refraction <+0.75D, and an elevated IOL/AL ratio are key determinants of high myopia risk following surgery. Shorter preoperative axial length was associated with a greater magnitude of postoperative myopic shift. This predictive framework provides clinicians with a practical tool to optimize preoperative IOL selection and identify high-risk infants who require vigilant myopia prevention and balanced amblyopia management.

Humans

Assessment of Surgical Salvage Outcomes for Exposed Cranial Neuromodulating Devices.

OBJECTIVES: Implanted neuromodulating devices (NMDs) such as cochlear implants (CIs) and deep brain stimulators (DBSs) are commonly used in modern medicine. Rarely, complications arise post-operatively, including hardware exposure. Traditional teaching suggests that these devices require removal if exposed; however, surgical salvage is a high risk, high reward alternative. We review our single institution experience managing NMD exposure with surgical salvage. METHODS: Retrospective chart review was performed on individuals who had a NMD implanted and underwent an attempt at surgical salvage for exposure during the study period (January 01, 2021 through December 31, 2023). Study outcome success was defined as maintaining a functional NMD 1&#x2009;year after salvage was attempted. Surgical techniques associated with successful salvage were compared. RESULTS: Nine of 729 patients (1.2%) implanted with NMDs experienced hardware exposure during this 2-year study period. Nine subjects were referred for NMD salvage; however, only 6 of 9 subjects (66.7%, CI&#x2009;=&#x2009;3; DBS&#x2009;=&#x2009;3) underwent NMD salvage attempts. Four of the subjects had successful salvage demonstrated successful salvage with a functioning NMD and without wound healing concerns 1&#x2009;year after their salvage procedure. CONCLUSIONS: Classic teaching states that exposed NMDs require explantation. However, this approach necessarily imposes time without benefit from the NMD between explantation and reimplantation. Our experience demonstrates that surgical salvage can be a successful alternative for the majority (66.7%) of individuals.

Humans

Intravenous Tranexamic Acid Reduces Perioperative Blood Loss in Reduction Mammoplasty With Immediate Implant-Based Reconstruction: A Randomized, Triple-Blinded, Placebo-Controlled Trial.

BACKGROUND: Postoperative hematoma and oozing can compromise outcomes after reduction mammoplasty with immediate reconstruction. Intravenous (IV) tranexamic acid (TXA) is antifibrinolytic, but prospective evidence in this setting is limited. OBJECTIVES: The aim of this study was to determine whether a single pre-incision dose of IV TXA reduces perioperative blood loss and fibrinolytic activation vs placebo. METHODS: In this randomized, triple-blinded, placebo-controlled trial, 60 women (American Society of Anesthesiologists I/II, 18-75 years) undergoing bilateral reduction mammoplasty with immediate implant-based reconstruction received TXA 10&#x2005;mg/kg in 100&#x2005;mL saline or placebo 10&#x2005;min before incision. The primary outcome was total blood loss within 24&#x2005;h (intraoperative suction + swab plus drain output). Secondary outcomes were perioperative changes in hemoglobin, D-dimer and fibrinogen, and complications within 30 days. Intention-to-treat analyses were performed. RESULTS: All patients completed follow-up. Total blood loss was lower with TXA than with placebo (mean &#xb1; standard deviation: 221.1 &#xb1; 72.4 vs 298.1 &#xb1; 90.6&#x2005;mL; mean difference -77.0&#x2005;mL; 95% CI, -122.4 to -31.6; P = .001). Intraoperative loss and 24&#x2005;h drain output were also reduced. Postoperative D-dimer rise was attenuated with TXA (0.31 &#xb1; 0.15 vs 0.49 &#xb1; 0.22&#x2005;&#xb5;g/mL; P = .002); hemoglobin decline was smaller. No thromboembolic, neurologic, or allergic events occurred; no skin-flap necrosis was observed. CONCLUSIONS: Pre-incisional IV TXA safely reduces perioperative bleeding and fibrinolytic activity after reduction mammoplasty. These findings support incorporation of IV TXA into perioperative protocols. LEVEL OF EVIDENCE: 2 (THERAPEUTIC): For image description, please refer to the figure legend and surrounding text.

Humans

Glaucoma filtering surgery combined with phacoemulsification in the era of new aqueous humor filtration devices: A systematic review.

We evaluate the efficacy and safety of filtering glaucoma surgeries combined with phacoemulsification (PCE)-including new aqueous humor drainage devices-compared to standalone procedures. We performed a systematic search up to March 23, 2025, including all comparative studies assessing trabeculectomy (TRAB), non-penetrating deep sclerectomy (NPDS), Xen&#xae; Gel Stent (XEN), or Preserflo&#xae; MicroShunt (PMS) combined with PCE, versus the same surgery alone. Key exclusion criteria include inadequate follow-up (less than 12-month), absence of a defined success criterion, more than 50% of loss to follow-up at 12-month, and lens extraction performed without PCE. Main outcome was surgical success at &#x2265;&#x202f;12 months. Secondary outcomes included intraocular pressure (IOP) reduction, decrease in hypotensive medications, and rates of complications. A total of 27 studies were included for analysis. Among studies comparing TRAB/PCE with standalone TRAB, half reported similar success rates, while others favored standalone TRAB, particularly using strict IOP thresholds. Safety profiles were comparable. For NPDS/PCE, data mostly showed equivalent outcomes versus standalone NPDS, with comparable safety. In studies on XEN/PCE and PMS/PCE, results suggested similar rates of surgical success, efficacy in IOP and medication reduction, and safety compared to their stand-alone procedures. Small differences occasionally favored standalone procedures under stricter success definitions. Current evidence suggests that combined filtering glaucoma surgery provides long-term efficacy and safety comparable to standalone, though some subgroups and outcome thresholds may slightly favor standalone approaches. The limited availability of high-quality prospective trials underscores the need for further large-scale robust studies.

Humans

Efficacy and Safety of Autologous Versus Prosthetic Grafts in the Repair of Popliteal Artery Aneurysms: A Systematic Review and Meta-Analysis.

BACKGROUND: Popliteal artery aneurysms (PAAs) present a severe risk of progression to acute limb ischemia. Open surgery (OS) is the gold standard treatment; however, prosthetic grafts are acceptable in highly selected cases, especially when the great saphenous vein is not available. METHODS: We performed a systematic review and meta-analysis of studies comparing autologous versus prosthetic grafts for patency and limb preservation outcomes in patients with PAAs. MEDLINE, Embase, and Cochrane Central were systematically searched from inception through October 2024. Outcomes were pooled using a frequentist random-effects model as odds ratios, mean differences, and hazard ratios (HRs) with 95% confidence intervals (CIs) on RStudio (Version 4.5.0). Risk-of-bias assessments were performed using ROBINS-I and MINORS. RESULTS: Twenty-two observational studies were pooled comprising 9,145 PAAs in 8,370 patients, of whom 6,434 (74.51%) were treated with autologous grafts and 2,200 (25.49%) with prosthetic grafts. Follow-up ranged from 12 to 86 months. Repair with autologous conduits significantly improved long-term primary patency (HR 3.93; P < 0.001), secondary patency (HR 6.02; P < 0.001), and long-term limb salvage (HR 2.69; P = 0.044) compared with prosthetic conduits. There were no significant differences in in-hospital amputation (P = 0.36), myocardial infarction (P = 0.61), mortality (P = 0.50), 2-year primary patency (P = 0.25), 5-year secondary patency (P = 0.06), or length of hospital stay (P = 0.95). Risk of bias was classified as moderate-to-high, reflecting confounding factors inherent to observational studies and moderate methodological quality by MINORS. Despite these limitations, treatment effects consistently favored autologous grafts in both short- and long-term analyses; however, caution is warranted given the limited number of available studies. CONCLUSION: The use of autologous conduits significantly favors both short-term and long-term efficacy and safety in the OS repair of PAAs. Given the limitations of the existing evidence, further comparative studies are needed.

Humans

Physician-Modified Fenestrated Stent-Grafts Planned Using Three-Dimensional Techniques for Complex Aortic Pathology: A Systematic Review and Meta-Analysis.

BACKGROUND: Complex aortic pathology involving the visceral arteries remains a significant therapeutic challenge. Open repair is associated with considerable perioperative risk, particularly in patients with multiple comorbidities, while standard endovascular aneurysm repair (EVAR) is often not feasible because of inadequate proximal sealing zones. Fenestrated and branched endovascular repair (F/BEVAR) represents an established treatment strategy; however, the use of custom-made devices is limited by manufacturing time and availability. Physician-modified stent grafts (PMSGs) have therefore emerged as a pragmatic alternative. Three-dimensional planning techniques have been increasingly used to facilitate accurate graft modification. The aim of this systematic review and meta-analysis was to evaluate the effectiveness and safety of PMSG procedures planned with three-dimensional techniques. Technical success, target vessel patency, early mortality, endoleak occurrence, and reintervention rates were analyzed. METHODS: A systematic search was conducted in the PubMed/MEDLINE and Embase databases. Studies describing the use of physician-modified fenestrated stent grafts planned with three-dimensional tools were included. Meta-analyses were performed using a random-effects model with restricted maximum likelihood estimation. A logit transformation was used for the analysis of proportions. RESULTS: The analysis included five studies involving 172 patients. The estimated weighted mean follow-up duration was 14.9 months. The overall technical success rate was 92.9% (95% confidence interval [CI]: 84.5-96.9%), with low-to-moderate heterogeneity. Target vessel patency was 96.9% (95% CI: 93.6-98.5%). Early mortality was 5.5% (95% CI: 2.1-13.3%). The incidence of endoleaks was 13.3% (95% CI: 5.8-27.4%), with significant heterogeneity among studies. Reinterventions were reported in 6.6% of patients (95% CI: 2.3-17.5%). CONCLUSION: The results indicate that PMSG procedures planned with three-dimensional techniques are associated with a high rate of technical success and preserved patency of target vessels in patients with complex aortic pathology. The observed variability in endoleak and reintervention rates likely reflects differences in anatomical complexity and patient selection among studies. Further prospective studies are needed to confirm long-term outcomes.

Humans

Total ankle replacement versus nonoperative management for end-stage ankle osteoarthritis: A comparative analysis.

BACKGROUND: The optimal management of end-stage ankle osteoarthritis remains debated. This study compared short-term outcomes between non-operative treatment, total ankle replacement (TAR), and cases in which indicated surgery was delayed. METHODS: In this secondary analysis of prospectively collected data, treatment survival, Foot and Ankle Outcome Score (FAOS), and patient satisfaction were assessed at baseline and at 1- and 2-year follow-up. RESULTS: In a total of 316 patients one-year treatment survival was highest for TAR (99.3%), followed by NOM (94.4%) and delayed surgery (80.9%). TAR demonstrated significantly superior FAOS pain and quality-of-life scores compared with NOM and delayed surgery. Delayed surgery was associated with significantly worse pain and quality-of-life outcomes. Patient satisfaction was highest in the TAR group and lowest in the delayed surgery group. CONCLUSIONS: TAR provides superior pain relief, quality of life, and satisfaction compared with non-operative management in end-stage ankle OA. While NOM remains a valid option for selected patients, delaying indicated surgery results in inferior outcomes, underscoring the importance of timely, shared decision-making.

Humans

K-wire versus screw fixation in Scarf-Akin osteotomy for hallux valgus: A retrospective cohort study.

BACKGROUND: Retention of metal implants after Scarf-Akin osteotomy (SAO) may cause irritation and psychological discomfort, often necessitating a hardware removal procedure. This study aimed to introduce K-wire fixation, allowing for outpatient removal, and to compare it with screw fixation. METHODS: This retrospective study included 64 patients with hallux valgus, comprising 32 in the K-wire fixation group and 32 in the screw fixation group. Clinical outcomes were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) score, visual analogue scale (VAS), and patient satisfaction. Radiographic parameters included hallux valgus angle(HVA), intermetatarsal angle(IMA), and distal metatarsal articular angle(DMAA). RESULTS: Both groups showed significant clinical and radiographic improvement (P&#x202f;<&#x202f;0.01). No significant between-group differences were observed in the other clinical or radiographic outcomes (P&#x202f;>&#x202f;0.05). Treatment costs were significantly lower in the K-wire group (P&#x202f;<&#x202f;0.001). CONCLUSIONS: K-wire fixation provides clinical and radiographic outcomes comparable to screw fixation, while avoiding the need for an additional procedure to remove the implant. LEVEL OF EVIDENCE: Level III.

Humans

Surgical management of esophageal atresia with tracheoesophageal fistula in extremely low birth weight neonates: A systematic review.

BACKGROUND: Surgical management of esophageal atresia/tracheoesophageal fistula (EA/TEF) in extremely low birth weight (ELBW) neonates remains challenging and controversial. This study systematically reviews surgical strategies and outcomes in this population. METHODS: Following PRISMA guidelines, Cochrane, Embase, MEDLINE, Scopus, and Web of Science (2004-2024) were searched in February 2025 for studies on surgical management of ELBW neonates with EA/TEF (PROSPERO CRD42025636228). Fatal chromosomal abnormalities were excluded. Demographics, comorbidities, surgical techniques, and complications were analyzed descriptively. Risk of bias was assessed. RESULTS: Eleven publications (five case reports and six case series) comprising 30 patients (Gross type B/C = 1/29) met the eligibility criteria. Mean gestational age was 28.1 (23-34) weeks, and mean birth weight was 760.4 (422-995) g. Twelve primary repairs (PR) and 18 delayed primary repairs (DPR) were performed, including staged repair (n = 11), lower esophageal banding (n = 4), and other techniques (n = 3). Postoperatively, four anastomotic leaks were managed conservatively, six strictures and one recurrent TEF required endoscopic intervention, three fundoplications and two aortopexies were reported (follow-up: 1-198 months, n = 19). Overall mortality was 30% (PR: 8.3%; DPR: 44.4%). Mortality was 60% among neonates with major congenital heart defects (CHD) and 40% among those with VACTERL association. EA/TEF-related complications contributed to 33.3% of deaths. CONCLUSIONS: Mortality in this cohort remains high, particularly with major CHD, and is largely unrelated to EA/TEF-specific complications. In selected cases, PR appears feasible as an alternative to DPR, although conclusions are limited by the small sample size and heterogeneous studies.

Humans

Comparison of short-term clinical outcomes and patient satisfaction between intraoral scanning and conventional impressions for complete-arch implant prostheses: a pilot RCT.

OBJECTIVE: To compare framework passive fit, subjective evaluations, and short-term clinical outcomes between conventional impressions (CI) and intraoral scanning (IOS) for complete-arch implant-supported fixed dental prostheses (CIFDPs). METHODS: In this randomized controlled trial, 22 patients were allocated to the CI or IOS groups. All participants received a definitive one-piece CIFDP. The primary outcome was framework passive fit, assessed using the Vision and Tactile Score (V&T score), which included framework lift-off, the single-screw test, the full-screw test, smoothness of screw insertion, and radiographic gap assessment. Secondary outcomes included operator evaluation, patient satisfaction using a visual analog scale (VAS), early implant survival, marginal bone loss (MBL), modified Plaque Index (mPII), and complications at the 6-month follow-up. RESULTS: Twenty-two patients were enrolled (CI: n = 11; IOS: n = 11), and one patient in the CI group was lost to follow-up. No statistically significant difference in the V&T score was observed between the CI and IOS groups (4.66 &#xb1; 0.17 vs. 4.65 &#xb1; 0.28; P = 0.93). The operator reported greater nervousness during the CI procedure than during IOS (21.82 &#xb1; 15.69 vs. 8.64 &#xb1; 7.47; P < 0.05). Patients in the CI group reported significantly greater discomfort, including nausea and anxiety, than those in the IOS group (P < 0.05). At the 6-month follow-up, the early implant survival rate was 100% in both groups. No significant differences were found between the groups in MBL (0.09 &#xb1; 0.09 vs. 0.06 &#xb1; 0.10 mm; P = 0.43) or mPII (0.10 &#xb1; 0.12 vs. 0.10 &#xb1; 0.28; P = 0.99). CONCLUSION: IOS and CI achieved comparable short-term clinical outcomes in patients who met the predefined inclusion criteria, including controlled implant number, spacing, and angulation. IOS provided a more favorable experience for both operators and patients. CLINICAL SIGNIFICANCE: In complete-arch implant restorations, intraoral scanning may provide clinical outcomes comparable to those of conventional impressions while improving patient comfort.

Humans

A framework for delivering real-time, instrument-relative navigation in transoral robotic surgery.

Transoral robotic surgery (TORS) is a minimally invasive, inside-out technique that, compared with traditional open approaches, provides fewer post-operative complications, shorter hospital stays, and improved survival for early-stage head and neck cancer. However, TORS is limited by its steep learning curve and poor visualization of deep tumor margins. This randomized crossover study evaluated a surgical navigation system's potential to enhance accuracy and user experience with real-time, instrument-relative feedback. Seven Teflon beads (d&#x2009;=&#x2009;2.381&#xa0;mm) were embedded at the tongue base of a porcine pharynx-and-larynx model. Tongue blade compression and retraction were applied to the model to mimic intraoperative tissue deformation, reproducing the anatomical shifts that occur relative to preoperative imaging. Eight participants used the da Vinci Surgical system to localize the beads by placing pins under two conditions: (a) preoperative computed tomography with no navigation; (b) model-based visual navigation with quantitative instrument-to-target metrics. Surgical accuracy was determined by calculating the target localization error (TLE, pin-to-bead Euclidean distance) and the angular error (AE, pin axis trajectory to bead). Accounting for training level and bead depth, surgical navigation reduced TLE by 5.44&#xa0;mm (95% CI, 4.02-6.86&#xa0;mm; p&#x2009;=&#x2009;2.00e-11) and AE by 8.47 degrees (95% CI, 6.21-10.72 degrees; p&#x2009;=&#x2009;5.17e-11). Impressions of the system were generally favorable using a 5-point Likert survey and task duration (p&#x2009;=&#x2009;0.26) or cognitive workload via the NASA-Task Load Index (p&#x2009;=&#x2009;0.22) were not significantly affected. The navigation system demonstrated translational promise, offering improved target localization accuracy and more consistent performance across experience levels, two critical determinants of surgical quality in TORS.

Robotic Surgical Procedures

Indications, Techniques and Complications Associated With Pterygoid Implants: A Systematic Review and Meta-Analysis.

BACKGROUND AND OBJECTIVES: Pterygoid implants represent a graftless option for rehabilitation of patients with posterior maxillary atrophy, engaging the dense cortical bone of the pterygomaxillary complex. Despite clinical growth, a comprehensive synthesis of indications, surgical techniques, and complications is lacking. This review evaluated the prevalence of complications, implant survival rates, and marginal bone loss (MBL) associated with pterygoid implant placement. METHODS: The reporting of this review follows PRISMA 2020 guidelines. Six electronic databases (PubMed, Ovid, Scopus, WoS, CENTRAL, and Dentistry & Oral Sciences Source) were searched from 1 January 2020 to 31 December 2025. Included criteria comprised randomized and non-randomized clinical studies reporting outcomes of pterygoid implants (&#x2265;&#x2009;13&#x2009;mm) in adult patients with posterior maxillary atrophy (minimum 10 implants). Risk of bias was assessed using JBI critical appraisal checklists. Proportions were pooled using the Freeman-Tukey double arcsine transformation under a random-effects model. Certainty of evidence was assessed using GRADE. RESULTS: Seventeen studies reporting 846 patients and 1915 pterygoid implants were included. The pooled survival rate was 97.9% (95% CI: 97.1%-98.6%; I2&#x2009;=&#x2009;0%; 14 studies) and the overall failure rate was 2.1% (95% CI: 1.4%-3.0%). Early failure rate was 0.9% (95% CI: 0.0%-3.0%; I2&#x2009;=&#x2009;59.5%). Late failure and MBL were summarized narratively. Certainty of evidence was low to very low. CONCLUSIONS: Pterygoid implants demonstrate excellent survival (97.9%) and low failure rates (2.1%), primarily early, supporting their reliability as a graftless solution for posterior maxillary atrophy. Complications appear infrequent though heterogeneously reported. Low evidence certainty necessitates prospective studies with standardized outcome reporting.

Humans

A translational framework for early-phase inner-ear gene therapy: clinical trial design, regulatory strategy, and ethical considerations.

PURPOSE OF REVIEW: Hereditary hearing loss has historically been approached as a diagnostic category rather than a therapeutically modifiable disease. Recent advances in molecular genetics, cochlear gene delivery, and first-in-human clinical trials are changing that. This review summarizes contemporary progress in the genetics of hearing loss, with emphasis on emerging gene-based therapies, clinical trial design, regulatory and ethical considerations, and practical implications for otolaryngologists as biologic treatment enters clinical practice. RECENT FINDINGS: Early clinical trials targeting OTOF -related DFNB9 deafness have demonstrated satisfactory safety profiles and meaningful auditory recovery, establishing the first proof-of-concept for cochlear gene therapy in humans, culminating in the April 2026 FDA approval of Otarmeni. Genetic diagnoses are increasingly informing prognosis, cochlear implant counseling, and therapeutic candidacy. Preclinical research continues to expand toward recessive, dominant, and syndromic hearing loss using gene replacement, antisense, RNA interference, and genome-editing strategies. Substantial challenges remain, including heterogeneous outcome measures, uncertain long-term efficacy, regulatory complexity, and inequitable global access. SUMMARY: The genetics of hearing loss is transitioning from a diagnostic modality to an interventional one. Widespread clinical impact will require advances in vector engineering, equitable implementation, multidisciplinary counseling, and integration with established rehabilitation pathways. For otolaryngologists, genetic literacy is becoming essential to contemporary hearing care.

Humans

Clinical accuracy and short-term outcomes of intraoral photogrammetry for complete-arch implant rehabilitation: A retrospective multicentre study on 35 patients.

OBJECTIVES: To evaluate the clinical accuracy and short-term outcomes of complete-arch implant-supported fixed dental prostheses (ISFDPs) fabricated using an intraoral photogrammetry (IPG) based digital workflow in completely edentulous patients. METHODS: This multicenter retrospective clinical study included 35 patients rehabilitated with 52 complete-arch ISFDPs (10 FP1, 18 FP2 and 24 FP3 restorations) supported by 221 implants. All definitive prostheses were designed and fabricated using a fully digital workflow initiated by IPG acquisition with the Aoralscan Elite IPG&#xae; (SHINING 3D). The primary outcome was clinical accuracy, assessed at definitive prosthesis delivery through evaluation of passive fit using the Sheffield test and radiographic verification. Secondary outcomes included biologic and prosthetic complications, as well as implant and prosthesis survival rates during the follow-up. RESULTS: Passive fit was achieved in all definitive restorations (100%). Radiographic evaluation confirmed accurate marginal adaptation at the implant-prosthesis interface in all cases. No statistically significant differences in clinical accuracy were observed according to treated arch, number of supporting implants, or prosthetic design (P > .05). During a mean follow-up period of 12.1 &#xb1; 3.5 months, biologic and prosthetic complications were limited and generally minor. Implant survival was 99.5%, and prosthesis survival was 100%. CONCLUSIONS: Within the limitations of this retrospective clinical study, the IPG based workflow demonstrated high clinical accuracy and predictable short-term outcomes for complete-arch implant rehabilitation, consistently enabling passive fit and favorable prosthetic performance. CLINICAL RELEVANCE: IPG may represent a clinically reliable and predictable approach for complete-arch digital implant impression acquisition. The high rates of passive fit, together with the low incidence of biologic and prosthetic complications observed in this multicenter clinical study, support the use of IPG based workflows for the fabrication of complete-arch ISFDPs.

Humans