Search PubMedSearch

SEARCH · Search PubMed

Results for “percutaneous left ventricular assist device”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

290 recordsLinked to original sources

Percutaneous left ventricular assist device in cardiogenic shock associated with and without acute myocardial infarction: a real-world retrospective cohort study.

BACKGROUND: Percutaneous left ventricular assist devices (pLVAD, such as Impella), are increasingly used for cardiogenic shock (CS). Outcomes may differ between acute myocardial infarction-related CS (AMI-CS) and non-AMI CS due to differing pathophysiology and trajectories. METHODS: Using the USA TriNetX Network (2016-2024), we identified adults with CS treated withpLVAD. AMI-CS was defined by MI within seven days of implantation; non-AMI CS included all patients with CS not attributable to acute MI, representing heterogeneous etiologies such as decompensated cardiomyopathy, myocarditis, valvular failure, pulmonary vascular causes, and arrhythmic shock. Patients with recent coronary artery bypass graft (CABG) were excluded. Propensity matching produced two balanced cohorts (n&#x2009;=&#x2009;2,026 each). RESULTS: Among 6,873 AMI-CS and 4,521 non-AMI CS patients, matched groups were similar (mean age 63&#x2009;years, 26% female). AMI-CS had higher mortality at 30&#x2009;days (hazard ratio [HR] 1.19, p&#x2009;=&#x2009;0.002), 90&#x2009;days (HR 1.13, p&#x2009;=&#x2009;0.02), and 180&#x2009;days (HR 1.14, p&#x2009;=&#x2009;0.007). Heart failure (HF) exacerbations (HR 1.21, p&#x2009;<&#x2009;0.001) and pulmonary edema (HR 1.23, p&#x2009;=&#x2009;0.005) were also more common in AMI-CS. Stroke, ventricular arrhythmias, cardiac arrest, acute kidney injury, major bleeding, vascular complications, and hemodialysis were comparable. CONCLUSION: AMI-CS patients supported with pLVAD experienced higher mortality and greater HF-related morbidity than non-AMI CS.

Humans

Prothrombin complex concentrate (PCC) vs. non-PCC strategies for warfarin reversal in left ventricular assist device recipients: A systematic review and meta-analysis.

BACKGROUND: Left ventricular assist devices (LVADs) prolong survival in end-stage heart failure, and warfarin thromboprophylaxis is recommended to prevent device thrombosis and thromboembolic complications. When bleeding occurs or emergency surgery is required, rapid anticoagulation reversal is critical. Prothrombin complex concentrate (PCC) provides rapid reversal; however, its risk-benefit profile in LVAD recipients remains unclear. We conducted a systematic review and meta-analysis comparing PCC with non-PCC strategies for warfarin reversal in LVAD recipients. METHODS: MEDLINE, Embase, and Scopus were searched through June 2025 for studies of PCC versus non-PCC strategies for warfarin reversal in LVAD recipients. Two reviewers independently extracted data. Random-effects models were used to pool arm-level estimates and to pool head-to-head comparisons using mean differences or risk ratios (RRs). RESULTS: Eighteen studies involving 779 patients were included. Arm-level pooled estimates for PCC versus non-PCC comparators were 24.0% versus 15.8% for mortality, 16.5% versus 12.1% for thrombotic events, and 3.1 versus 5.7 for FFP units. Arm-level time to INR correction was longer with PCC overall (16.5 versus 13.6&#xa0;h), driven by one elective cohort, but faster within the ICH subgroup (6.0 versus 13.7&#xa0;h). In head-to-head comparisons, PCC achieved faster INR correction than non-PCC comparators (mean difference&#xa0;-&#xa0;7.6&#xa0;h; p&#xa0;=&#xa0;0.001) and required fewer FFP units (-2.6&#xa0;units; p&#xa0;=&#xa0;0.019), with no significant difference in all-cause mortality (RR 1.14; p&#xa0;=&#xa0;0.490) or thrombotic events (RR 1.43; p&#xa0;=&#xa0;0.176). CONCLUSIONS: In head-to-head studies, PCC was associated with faster INR correction and lower FFP requirements than non-PCC strategies, whereas mortality and thrombotic events did not differ significantly. Given the observational evidence, wide confidence intervals, and heterogeneity, equivalent safety cannot be established, and prospective studies are needed to define the relative safety and effectiveness of the two approaches. IMPLICATIONS FOR CLINICAL PRACTICE: PCC-based strategies may be considered for urgent warfarin reversal in LVAD recipients, particularly when rapid INR reduction or avoidance of large-volume plasma transfusion is clinically important. Treatment decisions should account for the indication, bleeding severity, and underlying thrombotic risk. TRIAL REGISTRATION: CRD42024573925.

Humans

Initial 4-Year Experience With Microaxial Flow Pumps Within a Tertiary Centre in Regional Australia.

BACKGROUND & AIM: The Microaxial Flow Pump (MFP) is a miniaturised rotary pump that aspirates blood from the left ventricle and expels it into the ascending aorta. It unloads the left ventricle and increases mean arterial pressure and cardiac output. MFP is most commonly utilised in cardiogenic shock, for protected percutaneous coronary intervention (PCI), and for ventricular offloading in veno-arterial extracorporeal membrane oxygenation (VA-ECMO). METHOD: We conducted a retrospective review of all patients who underwent MFP insertion at John Hunter Hospital, Australia. Categorical data are represented as counts and percentages, with continuous variables described as means with standard deviations. RESULTS: Twenty-three MFP devices were inserted between September 2020 and May 2024. Five (22%) were for protected PCI, three (13%) for venting with VA-ECMO (ECPELLA), and 15 (65%) for acute coronary syndrome (ACS) and cardiogenic shock. The median age for the overall cohort was 62 years, with a 74% male predominance. Eighty percent of the protected PCI cohort were elective outpatient procedures, and there were no deaths in this cohort. The mortality in the ECPELLA group was 67%. Thirteen (87%) of the patients with cardiogenic shock presented with an anterior infarct, and 53% had cardiac arrest on admission. The overall morality in the cardiogenic shock cohort was 40%. Complications in this cohort included limb ischaemia in four patients (17%) and site bleeding in seven patients (30%). Four patients (17%) required vascular surgery intervention. CONCLUSION: Our initial experience showed the use of MFP in a tertiary centre was safe and feasible, allowing progression from protected percutaneous intervention to acute cardiogenic shock.

Humans

Fundamentals of pacemakers ECG interpretation - part 2.

BACKGROUND: Modern pacemakers incorporate arrhythmia-response algorithms, ventricular pacing minimization protocols, and safety mechanisms that generate ECG patterns indistinguishable from pathological AV block, sensing malfunction, or device-mediated tachycardia. Failure to recognize these algorithm-driven signatures leads to unnecessary interventions, misdiagnosis, and inappropriate device reprogramming. This manuscript is the second in a two-part series on pacemaker ECG interpretation. METHODS: We conducted a narrative review of peer-reviewed literature and device-specific documentation on algorithm-driven ECG behavior, synthesizing evidence across arrhythmia recognition, upper rate physiology, ventricular pacing minimization, mode switching, safety mechanisms, and hysteresis algorithms. RESULTS: Pacemaker-mediated tachycardia produces regular paced wide-complex tachycardia locked at the upper tracking rate, initiated by any event with retrograde VA conduction. Ventricular tachycardia is identified by QRS morphology diverging from the known paced pattern, absent pacing spikes, and AV dissociation. Upper rate Wenckebach behavior mimics Mobitz type I AV block; 2:1 upper rate response mimics second-degree AV block. Ventricular pacing minimization algorithms produce isolated nonconducted P waves and prolonged AV intervals that simulate pathological conduction disease. Mode switching causes abrupt rate drops misidentified as output failure. Ventricular safety pacing generates a conspicuously short, fixed AV interval. Three discrete pacing artifacts reflect AV-sequential cardiac resynchronization therapy (CRT), ventricular safety pacing in CRT, or His-bundle pacing with backup RV output. Rate and AV hysteresis produce pauses and wandering AV intervals mimicking oversensing or Wenckebach periodicity. CONCLUSIONS: Recognizing algorithm-driven ECG patterns requires knowledge of device timing intervals and refractory periods, which lets clinicians distinguish programmed behavior from true malfunction or cardiac arrhythmia.

Humans

Left ventricular hypertrophy in hypertension: a systematic review and meta-analysis of echocardiographic studies published from 2011 to 2025.

AIM: An updated meta-analysis targeting the prevalence of left ventricular hypertrophy (LVH), a cardinal marker of hypertensive heart disease (HHD), over the last 15&#x200a;years is lacking. Thus, we analyzed the literature in order to provide a comprehensive information on LVH prevalence, as assessed by echocardiography, in the hypertensive setting. METHODS: The PubMed, OVID-MEDLINE, and Cochrane Library databases were analyzed to search English-language articles published from 1 January 2011 up to 31 December 2025. Studies were identified by using MeSH terms and crossing the following search items: 'left ventricular hypertrophy', 'left ventricular mass', 'hypertensive heart disease', 'echocardiography', 'hypertension', and 'subclinical cardiac damage'. RESULTS: A total of 51 studies including 74&#x200a;632 hypertensive patients were considered. Overall, the prevalence of LVH in the pooled cohort, defined according to criteria recommended by echocardiographic guidelines, was 36.6% (95% CI: 33.4-40%). Data provided by 18 studies ( n &#x200a;=&#x200a;40&#x200a;108 patients) showed that the probability of having LVH was lower in men than in women (OR&#x200a;=&#x200a;0.62, CI: 0.48-0.80, P &#x200a;<&#x200a;0.0001). Among patients with LVH (17 studies), the risk of concentric LVH was almost twice as high as eccentric (OR&#x200a;=&#x200a;1.94, CI: 1.52-2.49, P &#x200a;<&#x200a;0.0001). CONCLUSION: Our meta-analysis suggests that the high contemporary prevalence of LVH reflects the failure of therapeutic strategies worldwide in the prevention and treatment of HHD. From a clinical perspective, these data imply the need for a more aggressive treatment of hypertension and related cardiovascular risk factors leading to LVH, especially in women.

Humans

Recurrence of peripartum cardiomyopathy in subsequent pregnancy stratified by left ventricular function: a systematic review and meta-analysis.

AIMS: Subsequent pregnancy in women with prior peripartum cardiomyopathy (PPCM) carries a risk of relapse and adverse maternal outcomes. This meta-analysis aimed to determine the recurrence of PPCM relapse and associated maternal and foetal outcomes during subsequent pregnancy, stratified by baseline (pre-subsequent pregnancy) left ventricular ejection fraction (LVEF). METHODS: A systematic review and meta-analysis was conducted in accordance with PRISMA guidelines. Nine databases were searched through June 2025 for cohort studies reporting subsequent pregnancy outcomes in women with prior PPCM, stratified as recovered (LVEF &#x2265;50%) or non-recovered (LVEF <50%) groups. Outcomes included PPCM relapse, maternal mortality, LVEF during and after pregnancy, LV recovery, symptom worsening, and obstetric/neonatal events. Risk of bias was assessed with ROBINS-E, and random-effects models were used. RESULTS: Six cohort studies comprising 266 women were included (174 in recovered group and 92 in non-recovered group). Relapse occurred in both groups with no significant difference [rate ratio (RR) 0.77, 95% CI 0.50-1.19; I2 = 3%]. Maternal mortality was significantly lower in the recovered group (1.7% vs 10.9%; RR 0.27, 95% CI 0.09-0.87; I2 = 0%). Recovered group had higher mean LVEF during subsequent pregnancy (mean difference [MD] 17.0; P < .001), higher postpartum LVEF (MD 11.69; P = .005; I2 = 84%), and greater likelihood of LV recovery (RR 2.07; P = .005; I2 = 0%). No significant differences were observed in symptom worsening or obstetric/neonatal outcomes. CONCLUSION: Recovered LVEF prior to subsequent pregnancy is associated with improved maternal outcomes, yet relapse remains common. Left ventricular ejection fraction alone is insufficient for risk stratification, and individualized multidisciplinary care is essential for all women with prior PPCM.

Female

Cine-derived mitral annular relaxation velocity for detection of preclinical left ventricular diastolic dysfunction.

OBJECTIVES: Imaging diastolic dysfunction in pre-clinical heart failure (HF) is challenging. We evaluated a novel cardiac MRI (CMR) biomarker, CMR e-prime (CMR-MARV), in patients at risk of HF. METHODS: In this substudy of the PARABLE trial (NCT04687111), 236 patients (71.6&#xa0;&#xb1;&#xa0;7.7&#xa0;years, 61.6% male) fulfilling trial-defined ALVDD citeria underwent CMR with measurement of mitral annular relaxation velocity (CMR-MARV) at four mitral annular anchor points. Diastolic strain rates from FT were also assessed. Twenty-five age- and sex-matched controls were included (73.8&#xa0;&#xb1;&#xa0;3.1&#xa0;years, 52% male). Group differences were tested with t-tests, diagnostic accuracy with ROC analysis, and predictors of diastolic dysfunction with adjusted logistic regression. RESULTS: Compared with controls, patients had significantly higher indexed maximal left atrial volume (LAVimax), LV end-diastolic and end-systolic volumes, and LV mass (all p&#xa0;<&#xa0;0.001). Of FT variables, only peak diastolic longitudinal velocity differed between groups (p&#xa0;<&#xa0;0.001). In multivariate models, CMR-MARV correlated with radial, circumferential, and longitudinal diastolic strain rates, radial and longitudinal diastolic velocities (all p&#xa0;<&#xa0;0.001), echocardiographic e' (r&#xa0;=&#xa0;0.20, p&#xa0;=&#xa0;0.007), LV mass (r&#xa0;=&#xa0;-0.18, p&#xa0;=&#xa0;0.008), LAVimax (r&#xa0;=&#xa0;-0.18, p&#xa0;=&#xa0;0.008), and NT-proBNP (r&#xa0;=&#xa0;-0.30, p&#xa0;<&#xa0;0.0001). LAVimax and CMR-MARV were strongly independently associated with ALVDD (AUC 0.89 and 0.76, respectively; p&#xa0;<&#xa0;0.0001). A combined model (LAVimax + CMR-MARV) achieved excellent discrimination (AUC 0.91, 95% CI 0.86-0.97, p&#xa0;<&#xa0;0.0001). Independent predictors included LAVimax, CMR-MARV, and peak diastolic longitudinal velocity (all p&#xa0;<&#xa0;0.001). CONCLUSION: CMR-MARV provides a simple cine-derived measure of longitudinal relaxation that correlates with established structural and biochemical markers of diastolic burden. Within an at-risk population, it offers incremental functional information beyond conventional parameters and may support multiparametric CMR phenotyping of preclinical diastolic dysfunction.

Aged

Ultra-high-frequency ECG quantifies residual electrical dyssynchrony during left bundle branch area pacing in patients with wide QRS: a paired within-patient study.

BACKGROUND: Left bundle branch area pacing (LBBAP) may restore a more physiological pattern of ventricular activation in patients with conduction delay; however, QRS narrowing alone may incompletely characterize electrical resynchronization. Ultra-high-frequency ECG (UHF-ECG) provides quantitative markers of ventricular activation timing and dyssynchrony. OBJECTIVE: To quantify paired OFF-to-ON changes in conventional ECG and UHF-ECG metrics during LBBAP in patients with baseline wide QRS and to assess the relationship between paced R-wave peak time (RWPT) and residual UHF-ECG dyssynchrony. METHODS: In this prospective single-center paired study, 21 patients with bradycardia and baseline wide QRS underwent standard ECG and UHF-ECG assessment during intrinsic rhythm (pacing OFF) and during LBBAP (pacing ON). Endpoints included QRS duration, signed VED16, absolute VED16 (|VED16|), mean ventricular delay (meanVD), and a clinically interpretable distance-to-normal metric defined as dist&#xa0;=&#xa0;max(|VED16|-20, 0). Paired changes were summarized as medians with bootstrap 95% confidence intervals and tested using the Wilcoxon signed-rank test. Associations between paced RWPT and residual dyssynchrony during pacing were evaluated using Pearson and Spearman correlation coefficients. RESULTS: LBBAP significantly narrowed QRS duration from 136.8 [130.2-153.6] ms during intrinsic rhythm to 116.0 [107.8-125.6] ms during pacing (median &#x394; -21.0&#xa0;ms; 95% CI -33.9 to -18.6; p&#xa0;<&#xa0;0.001). Signed VED16 did not change significantly (median &#x394; 0.4&#xa0;ms; p&#xa0;=&#xa0;1.000), consistent with the mixed conduction-phenotype composition of the cohort. In contrast, severity-oriented UHF-ECG endpoints improved: |VED16| decreased numerically (median &#x394; -5.2&#xa0;ms; p&#xa0;=&#xa0;0.070), whereas dist decreased significantly (median &#x394; -0.7&#xa0;ms; 95% CI -14.4 to 0.0; p&#xa0;=&#xa0;0.015). The proportion of patients within the normal dyssynchrony band (|VED16|&#xa0;&#x2264;&#xa0;20&#xa0;ms) increased from 7/21 (33.3%) to 12/21 (57.1%). Median paced RWPT was 66.6 [58.6-74.6] ms, and shorter RWPT correlated with lower residual |VED16| during pacing (Pearson r&#xa0;=&#xa0;-0.45, p&#xa0;=&#xa0;0.038). CONCLUSIONS: In patients with baseline wide QRS, LBBAP produces marked QRS narrowing, whereas UHF-ECG provides complementary quantification of residual electrical dyssynchrony. Severity-oriented UHF-ECG endpoints, particularly a distance-to-normal metric, may offer an interpretable mechanistic framework beyond conventional ECG alone. Shorter paced RWPT was associated with lower residual dyssynchrony during pacing, supporting physiological coherence between procedural and high-resolution electrocardiographic markers.

Humans

Conduction System Pacing Versus Right Ventricular Pacing in Patients With Atrioventricular Block and Anticipated High Pacing Burden.

Right ventricular pacing (RVP) in patients with atrioventricular (AV) block and high anticipated pacing burden is associated with pacing-induced cardiomyopathy (PICM) in approximately 12% to 20% of patients, whereas conduction system pacing (CSP) preserves more physiologic ventricular activation and may mitigate these consequences; the totality of contemporary randomized evidence has not been systematically pooled. We conducted a systematic review and meta-analysis of randomized controlled trials (RCTs) comparing CSP with RVP in patients with AV block or anticipated high ventricular pacing burden and a minimum 6-month follow-up, with co-primary outcomes of PICM incidence and change in left ventricular ejection fraction (&#x394;LVEF) and secondary outcomes of heart failure hospitalization (HFH), all-cause mortality, composite clinical endpoint, and paced QRS duration (PROSPERO CRD420261400227); random-effects meta-analysis used DerSimonian-Laird estimation. Five RCTs (LBBP-FAVOUR, CSPACE, Prague CSP, PACE-HF, STAY; N = 806) met inclusion criteria. CSP significantly reduced PICM (hazard ratio [HR] 0.30, 95% confidence interval [CI] 0.18 to 0.48; p <0.001; I&#xb2; = 0%; k = 4), was associated with greater LVEF preservation (pooled mean difference [MD] +4.41%, 95% CI +1.82 to +6.99; p = 0.001; I&#xb2; = 87%; k = 5), and reduced HFH (HR 0.24, 95% CI 0.12 to 0.48; p <0.001; I&#xb2; = 0%; k = 5). CSP shortened paced QRS duration (MD -27.5 ms, 95% CI -32.6 to -22.5; p <0.001; k = 5). All-cause mortality was numerically lower with CSP but did not reach significance (HR 0.57, 95% CI 0.29 to 1.12; p = 0.10; k = 4). In a prespecified sensitivity analysis restricting to multicenter trials with N &#x2265; 150, all findings were concordant with the primary analysis. In conclusion, CSP substantially reduces PICM, preserves LVEF, and reduces HFH compared with RVP in patients with AV block and anticipated high pacing burden, supporting its consideration as the preferred pacing strategy in appropriately selected patients.

Humans

Robot-assisted versus manual percutaneous vascular interventions across vascular territories: a systematic review and meta-analysis.

Robot-assisted percutaneous vascular intervention (R-PVI) has expanded beyond coronary procedures, but previous reviews were largely coronary-focused and observational. Recent randomized controlled trials (RCTs) warrant broader reassessment of R-PVI versus manual percutaneous vascular intervention (M-PVI) across vascular territories. PubMed, Embase, Web of Science, and the Cochrane Central Register of Controlled Trials were searched from database inception to January 31, 2026, following PRISMA guidelines. RCTs and observational studies including &#x2265;10 adult patients in total were eligible. Comparative studies informed primary analyses, while single-arm studies provided supportive evidence. Primary outcomes were clinical success rate and major adverse cardiovascular/cerebrovascular events (MACE) rate. Secondary outcomes included mortality rate, technical success rate, procedural time metrics, contrast volume, and radiation exposure. Random-effects models were used. Forty studies were included: 3 RCTs, 10 comparative observational studies, and 27 single-arm observational studies, comprising 3,870 patients undergoing R-PVI and 1,142 undergoing M-PVI. Comparative analyses showed similar clinical success rates (RR 1.00, P = 0.46), MACE rates (RR 0.72, P = 0.43), and mortality. Single-arm pooled estimates for clinical and technical success were 98.76% and 96.09%, respectively. R-PVI prolonged total procedure time overall (MD 15.92&#xa0;min, P = 0.01), with consistent increases in the neurovascular, RCT, and non-RCT subgroups. Fluoroscopy time was also longer (MD 1.91&#xa0;min, P = 0.04), mainly in the RCT subgroup (MD 2.83&#xa0;min, P = 0.001). In contrast, intravascular intervention time was unchanged overall and in RCTs, but was prolonged in non-RCTs (MD 8.72&#xa0;min, P = 0.006). Operator radiation exposure was markedly reduced (MD -33.97 &#x3bc;Sv, P < 0.001), whereas patient radiation exposure and contrast volume were similar. R-PVI appears feasible and safe across selected vascular procedures. Its clearest benefit is reduced operator radiation exposure, whereas lower whole-procedure efficiency remains its main limitation.

Humans

Robotic Needle Insertion for CT-guided Percutaneous Biopsy of Thoracoabdominal Lesions: A Prospective Multicenter Randomized Trial.

Purpose To compare safety and feasibility between a novel CT-guided robotic system and the conventional freehand technique for puncture biopsy of thoracoabdominal lesions. Materials and Methods In this prospective multicenter randomized trial, individuals with suspected lesions were enrolled between July 2023 and April 2024 across three university teaching hospitals and randomized to the robot-assisted group (n = 82) or the freehand group (n = 83). Procedure outcomes included the technical success rate, targeting error, number of CT scans and needle adjustments, puncture time, and complications. Descriptive and inferential statistics were calculated. Results A total of 165 participants (mean age, 60 years &#xb1; 10 [SD]; 83 male) were included. Compared with the freehand group, the robot-assisted group demonstrated a higher technical success rate (97.56% [80 of 82] vs 62.65% [52 of 83], P < .001), lower targeting error (mean Euclidean deviation: 1.7 mm &#xb1; 1.1 vs 4.5 mm &#xb1; 3.9, P < .001), and fewer CT scans (mean, 4.3 &#xb1; 1.9 vs 5.2 &#xb1; 2.3; P = .002) and needle adjustments (mean, 0.7 &#xb1; 0.7 vs 1.6 &#xb1; 1.6; P = .003). Despite differences in geometric precision, both groups achieved 100% (82 of 82 and 83 of 83) diagnostic yield. The median puncture time was comparable between groups (5.5 minutes &#xb1; 4.3 vs 4.8 minutes &#xb1; 7.0, P = .50). During lung biopsies, the robot-assisted approach yielded fewer complications compared with the freehand approach (4.88% [four of 82] vs 16.87% [14 of 83], P = .014). Conclusion Compared with the freehand approach, robot-assisted biopsy yielded greater precision and reduced adjustments and complications while demonstrating noninferior diagnostic efficacy and comparable duration. Keywords: Robotic Needle Insertion, Biopsy, Thoracoabdominal Lesions, Robot-assisted Biopsy, CT-guided Intervention, Percutaneous Needle Biopsy, Randomized Controlled Trial, Algorithm Development, CT, Clinical Testing, Interventional-Body, Biopsy/Needle Aspiration, Percutaneous, Thorax, Abdomen/GI, Liver, Lung, Kidney &#xa9;RSNA, 2026.

Humans

Efficacy and safety of rib-guided percutaneous thoracic sympathetic radiofrequency thermocoagulation at two different targets for primary palmar hyperhidrosis: a randomized controlled trial.

OBJECTIVES: To compare the efficacy and safety of computed tomography-guided percutaneous thoracic sympathetic radiofrequency thermocoagulation (RFT) targeting the upper versus lateral margin of the fourth rib head for severe primary palmar hyperhidrosis (PPH). METHODS: Patients with severe PPH were randomly divided into Group U (upper margin target) and Group L (lateral margin target). Outcome measures included 1-year recurrence rate, Hyperhidrosis Disease Severity Scale (HDSS), Dermatology Life Quality Index (DLQI), palm skin temperature, finger perfusion index (PI), compensatory hyperhidrosis and patient satisfaction. RESULTS: Both groups (n&#x2009;=&#x2009;55 each, 110 sides) successfully underwent RFT. No preprocedural PI differences were found (p&#x2009;>&#x2009;0.05). Immediately post-RFT, PI in Group L was significantly higher than in Group U (left p&#x2009;=&#x2009;0.025, right p&#x2009;=&#x2009;0.013). No significant differences in HDSS grades were observed between groups before and at 1&#x2009;day, 2&#x2009;weeks, 1&#x2009;month and 3&#x2009;months post-procedure. However, at 6 and 12&#x2009;months, Group L showed significantly lower HDSS grades (left p&#x2009;=&#x2009;0.033 and 0.016; right p&#x2009;=&#x2009;0.039 and 0.025) and lower DLQI scores (p&#x2009;=&#x2009;0.037 and 0.024) than Group U. Patient satisfaction did not differ within 6&#x2009;months, but Group L had significantly higher satisfaction at 12&#x2009;months (p&#x2009;=&#x2009;0.036). CONCLUSIONS: Targeting the lateral margin of the fourth rib head for RFT achieved greater efficacy, better quality of life and higher patient satisfaction compared to the upper margin target.

Humans

Comparative effectiveness of percutaneous coronary intervention strategies for coronary small-vessel disease: a network meta-analysis of randomized trials.

BACKGROUND: Coronary small-vessel disease (SVD) remains challenging for percutaneous coronary intervention (PCI) because small lumens magnify restenosis and ischemic risk. Multiple devices are available, yet their comparative performance is uncertain. This study evaluated and ranked PCI strategies for SVD. METHODS: A systematic review and network meta-analysis was conducted in accordance with PRISMA. PubMed, Embase, the Cochrane Central Register of Controlled Trials, Web of Science, and Google Scholar were searched from inception to 15 August 2025. Eligible studies were English-language randomized controlled trials enrolling adults with angiographic SVD defined as reference vessel diameter &#x2264;3.0&#x2009;mm, comparing PCI strategies, and reporting target lesion revascularization (TLR), binary restenosis (BR), or myocardial infarction (MI). A frequentist random-effects network meta-analysis generated odds ratios (ORs) with 95% confidence intervals (CIs) and treatment rankings using the surface under the cumulative ranking curve (SUCRA). RESULTS: Thirty-nine trials including 14,503 patients met the criteria. For TLR (37 studies; 11,980 patients), the highest SUCRA values were observed with sirolimus-eluting stents (SES 90.1%), zotarolimus-eluting stents (ZES 83.9%), and everolimus-eluting stents (EES 82.2%). For BR (32; 6,468), SES, ZES, and paclitaxel-coated balloons (DCB-PTX) ranked highest (95.0%, 80.0%, and 78.3%). For MI (37; 11,602), SES, DCB-PTX, and ZES ranked highest (79.0%, 78.7%, and 68.5%). Representative effects showed SES reduced TLR versus bare-metal stents (BMS) (OR, 0.25; 95% CI, 0.15-0.43) and MI versus BMS (OR, 0.41; 95% CI, 0.21-0.79). Conventional approaches such as BMS, plain old balloon angioplasty (POBA), and gold-plated balloon angioplasty (GPBA) ranked lowest across outcomes. CONCLUSION: SES provides the most consistent clinical benefit for coronary SVD. ZES, EES, and DCB-PTX are effective alternatives in selected settings, whereas BMS, POBA, and GPBA are less effective. These findings offer comparative evidence to guide device selection in SVD.

Humans

Comparison of three tracking methods to assess usage of two pediatric powered mobility devices for young children with cerebral palsy.

Powered mobility devices are underutilized for promoting self-initiated mobility in young children with cerebral palsy due to prioritization of walking, caregiver effort, device characteristics, and environmental factors. Understanding device usage patterns is important to assess the impact of powered mobility interventions on child outcomes. As part of clinical trial (NCT04684576), three objective tracking methods including integrated loggers, Global Positioning System trackers (GPST), and caregiver reported activity logs (CRAL) were compared to provide insights into device usage patterns. Metrics included play session frequency, session duration, total usage minutes, and unique usage days for two powered mobility devices: Modified Ride-on Cars (MROC) and the Permobil Explorer Mini (EM). Twelve children with cerebral palsy used each device for eight consecutive weeks in home and community settings (16&#x2009;weeks total), with device ordered randomized. Results showed no significant differences among tracking methods for the MROC. For the EM, only session duration differed between GPST and CRAL. Correlation analysis revealed variable relationships amongst tracking methods for both devices. The EM was used more frequently than the MROC, with significantly greater total usage minutes and session duration via CRAL, not GPST. The findings highlight the need for reliable tracking technologies that can be used across powered mobility devices.

Child, Preschool

Effectiveness and usability of artificial intelligence-powered assistive technologies in Supporting daily activities of children with cerebral palsy: a systematic review.

BACKGROUND: Cerebral Palsy (CP) is the main cause of motor disabilities in childhood, necessitating innovative approaches to rehabilitation and assistive technology (AT). Simultaneously, artificial intelligence (AI) is increasingly being integrated into devices to create more adaptive, personalized, and effective AT. This systematic review aimed to evaluate the effectiveness and usability of AI-powered assistive technologies designed to support daily activities and rehabilitation in children with CP. MATERIALS AND METHODS: Five databases, including Scopus, Web of Science, PubMed, Embase, and IEEE Xplore, were systematically searched, and 23 articles were included in the final analysis. Articles were identified, selected, and categorized into emerging thematic areas based on the primary function and application of the technology. RESULTS: Five key thematic topics were identified: 1) AI-driven motor rehabilitation and gait training for functional mobility; 2) intelligent assessment and monitoring systems for clinical decision support; 3) AI-supported communication, social interaction, and intention recognition tools; 4) gamified and virtual reality-based interventions to enhance engagement and usability; and 5) smart assistive systems supporting daily living and independent mobility. The findings demonstrate a strong trend toward the application of AI technologies in personalized, engaging, and data-driven interventions for children with CP. However, the field is predominantly in the proof-of-concept stage, with limitations including small sample sizes, lack of long-term clinical validation, challenges in user-centered design, and usability for children with CP. CONCLUSION: AI-powered assistive technologies hold significant potential for transforming the care of children with CP by enabling highly personalized and engaging interventions. To actualize this potential, future work must realize that practical application remains challenging owing to limited clinical validation, technological integration, and usability barriers for children with CP. Future research must prioritize user-centered design and multidisciplinary collaboration to ensure that AI and robotic advancements improve the usability and quality of life for children with CP.

Humans

Feasibility and efficacy of left bundle branch area pacing guided by modified chest lead 1.

BACKGROUND: Left bundle branch area pacing (LBBAP) typically requires 12&#x2011;lead electrocardiogram (ECG) measurements using an electrophysiology (EP) recording system. However, a simplified approach using modified chest lead 1 (MCL1) is potentially feasible. This study aimed to compare the success rate and pacing outcomes of LBBAP guided by MCL1 with those guided by the 12&#x2011;lead ECG using an EP recording system. METHODS: This retrospective, single-center study included patients with preserved left ventricular ejection fraction who underwent LBBAP for bradyarrhythmia. LBBAP was either guided by 12&#x2011;lead ECG using an EP recording system or by MCL1. In the MCL1 group, a follow-up examination with a 12&#x2011;lead ECG using an EP recording system was conducted within one week postoperatively. RESULTS: A total of 65 patients underwent LBBAP (EP recording system group: n&#xa0;=&#xa0;35; MCL1 group: n&#xa0;=&#xa0;30). The overall success rate of LBBAP was 84.6%, with no significant difference between groups (88.5% vs. 80.0%, p&#xa0;=&#xa0;0.49). No significant differences were observed in the paced QRS duration (140.4&#xa0;&#xb1;&#xa0;8.0 vs. 141.9&#xa0;&#xb1;&#xa0;13.1&#xa0;ms, p&#xa0;=&#xa0;0.54), V6-V1 interpeak interval (39.7&#xa0;&#xb1;&#xa0;16.5 vs. 38.3&#xa0;&#xb1;&#xa0;15.6&#xa0;ms, p&#xa0;=&#xa0;0.79), or V6 R-wave peak time (69.8&#xa0;&#xb1;&#xa0;12.3 vs. 71.5&#xa0;&#xb1;&#xa0;12.1&#xa0;ms, p&#xa0;=&#xa0;0.68). CONCLUSIONS: MCL1-guided LBBAP was feasible and achieved a high success rate, with outcomes comparable to those of conventional EP recording system-guided implantation. This simplified approach may reduce procedural complexity and may allow LBBAP implantation without the routine use of an EP recording system.

Humans

Prognostic value of early changes in the frontal QRS-T angle in patients with heart failure and left bundle branch block undergoing cardiac resynchronization therapy.

BACKGROUND: Cardiac resynchronization therapy (CRT) reduces morbidity and mortality in selected patients with heart failure (HF). The frontal QRS-T angle (FQTA), reflecting ventricular depolarization-repolarization heterogeneity, has been associated with major adverse cardiovascular events (MACE). We aimed to assess the prognostic value of changes in the FQTA after CRT in predicting long-term MACE. METHODS: A total of 223 consecutive HF patients with left bundle branch block who underwent CRT between 2018 and 2022 were retrospectively analyzed. The FQTA was measured before and after CRT, and the change (&#x394;FQTA) was calculated. Receiver operating characteristic (ROC) analysis was performed to determine the optimal cutoff value for predicting the primary outcome, MACE. Patients were subsequently stratified according to this cutoff value. Independent predictors were identified using multivariable Cox proportional hazards regression analysis. RESULTS: ROC analysis identified 22.5&#xb0; as the optimal cutoff value for predicting MACE (AUC: 0.711; 95% CI: 0.642-0.781; p&#xa0;<&#xa0;0.001). During a mean follow-up of 34.6&#xa0;&#xb1;&#xa0;17.6&#xa0;months, patients with &#x394;FQTA <22.5&#xb0; had a significantly higher incidence of MACE compared with those with greater angle reduction (44.7% vs. 11.9%; p&#xa0;<&#xa0;0.001). In multivariable Cox regression analysis, chronic kidney disease (HR: 2.517; p&#xa0;=&#xa0;0.002) and &#x394;FQTA <22.5&#xb0; (HR: 4.56; p&#xa0;<&#xa0;0.001) were independently associated with MACE. CONCLUSION: A greater reduction in FQTA after CRT is associated with improved long-term outcomes and may serve as a practical electrocardiographic marker for risk stratification.

Humans