Search PubMedSearch

SEARCH · Search PubMed

Results for “mini screw‐assisted”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

300 recordsLinked to original sources

Double-Axis Maxillary Skeletal Expander Suggests Higher Expansion Efficiency in Early Activation: A Finite Element Analysis.

INTRODUCTION: Conventional single-axis maxillary skeletal expanders (MSE) have some drawbacks, such as limited control over maxillary expansion and possible asymmetric expansion between the anterior nasal spine (ANS) and posterior nasal spine (PNS). This report introduces a double-axis maxillary skeletal expander (DAMSE) concept to overcome these drawbacks and enhance the efficiency of maxillary skeletal expansion. MATERIALS AND METHODS: Five different DAMSE designs were compared with a conventional single-axis MSE. Finite element analysis was performed to analyse their expansion efficiency, stress magnitude and distribution occurring in a simplified bone model. RESULTS: DAMSE outperformed the single-axis MSE and provided better control over ANS and PNS expansion. During early activation, the highest expansion efficiency (31.7%) was achieved by DAMSE Model V, 13% more efficient than the single-axis MSE. This efficiency was increased to 100.8% by combining the DAMSE Model V with midpalatal suture surgery. However, with the simplified bone model, the current study could not demonstrate that DAMSE can resolve the issue of asymmetric expansion between ANS and PNS. CONCLUSIONS: An appropriately designed DAMSE can be a promising tool for maxillary expansion treatment. DAMSE offers more efficient treatment than the conventional single-axis MSE while maintaining similar levels of patient comfort and invasiveness.

Finite Element Analysis

Robot-assisted versus freehand cannulated-screw fixation for femoral neck fractures: a systematic review of technical, clinical and adoption outcomes.

Robot-assisted guidance may improve the technical precision of percutaneous cannulated-screw fixation for femoral neck fractures. Whether these procedural advantages translate into better clinical outcomes remains uncertain. We compared robot-assisted and conventional freehand fixation in adults with femoral neck fractures. MEDLINE, Embase and CINAHL were searched from inception to 15 July 2026 without language restrictions. Google Scholar was used only as a supplementary search source, together with forward and backward citation searching. Comparative studies of robot-assisted versus freehand fluoroscopy-guided cannulated-screw fixation were included. Risk of bias was assessed using RoB 2 and ROBINS-I, with the Newcastle-Ottawa Scale used as a complementary appraisal of non-randomised studies. Random-effects meta-analyses included prediction intervals and prespecified sensitivity analyses. The protocol was registered prospectively (PROSPERO CRD420261465038). Sixteen comparative studies involving 1,293 participants were included. Of these, 597 underwent robot-assisted fixation and 696 underwent freehand fixation. Two studies reporting random allocation and 14 non-randomised studies were included in the study. Robot-assisted fixation was associated with fewer guide-wire manipulations, greater screw-placement accuracy and 13.9 fewer fluoroscopic acquisitions per procedure (95% confidence interval [CI] -20.3 to -7.5). Earlier radiographic healing and modestly higher final Harris Hip Scores were also observed. Pooled estimates suggested lower risks of union failure, avascular necrosis and composite complications. Fluoroscopy duration, overall operative time and reoperation did not differ significantly. Heterogeneity was substantial for several continuous outcomes, with prediction intervals crossing the null for several estimates, indicating that the magnitude of benefit varied considerably between studies. Some clinical associations were also sensitive to eligibility-restricted analyses. Robot-assisted cannulated-screw fixation improves technical execution compared with freehand fixation. Patient-important clinical superiority and economic value have not been established, and evidence concerning learning curves, operator acceptability and system reliability remains insufficient. Current evidence does not support routine widespread adoption; adequately powered multicentre randomised trials incorporating economic and implementation evaluation are required.

Humans

Safety and Stability of a Combined C2 Screw Placement Strategy With Vertebral Artery Mobilization.

BACKGROUND: Although C2 pedicle screws are considered the gold standard for atlantoaxial fixation, the optimal fixation strategy for patients with high-riding vertebral arteries (HRVA) or narrow C2 pedicles (NC2P) remains controversial because of the increased risk of vertebral artery injury and the limitations of alternative fixation techniques. OBJECTIVE: To evaluate the safety, stability, and clinical efficacy of an individualized C2 screw fixation strategy incorporating vertebral artery mobilization for complex upper cervical anatomy. METHODS: A retrospective study was conducted in 312 patients who underwent C2 fixation between 2017 and 2025. Patients were categorized according to fusion method, screw laterality, and VA transposition requirement. Bone fusion rates and screw accuracy (Gertzbein-Robbins grading) were compared across groups using &#x3c7;2, Fisher's exact, and multivariate logistic regression analyses to control confounders. RESULTS: All procedures were successfully completed without permanent neurovascular injury. At 6&#x2009;months, the fusion rate with an atlantoaxial fusion cage was significantly higher than with interlaminar bone grafting (92.3% vs. 51.0%, p&#x2009;<&#x2009;0.001). Unilateral C2 pedicle screw fixation combined with a contralateral alternative screw achieved comparable stability to bilateral fixation (p&#x2009;>&#x2009;0.05). Screw placement accuracy was 100% clinically acceptable in normal anatomy and 60% in cases requiring VA mobilization, with no VA injury or blood flow compromise. CONCLUSION: The proposed multi-strategy C2 screw placement protocol-integrating fusion cage support and VA mobilization-achieves superior fusion, reliable fixation, and high safety, even in anatomically challenging conditions. This approach provides a reproducible and versatile solution for C2 instrumentation in complex craniovertebral junction surgery.

Humans

Application of Three-Dimensionally Printed Surgical Guides in Precise Sacral Tumor Excision and Defect Reconstruction.

OBJECTIVE: Precise resection of sacral tumors remains technically demanding due to their deep anatomical location and close proximity to critical neurovascular structures. Conventional freehand techniques often result in suboptimal resection margins, excessive blood loss, and compromised lumbopelvic stability. This study evaluated whether patient-specific three-dimensional (3D)-printed guiding templates improve surgical accuracy and perioperative outcomes in sacral tumor resection and reconstruction. METHODS: Nineteen patients undergoing en bloc sacral tumor resection (S1-S3 involvement) with spinopelvic reconstruction (2006-2020) were retrospectively analyzed. Patients were divided into a 3D-printing group (n&#x2009;=&#x2009;10) and a conventional freehand group (n&#x2009;=&#x2009;9). In the 3D-printing group, computer-aided design and 3D-printed templates were used for osteotomy, screw placement, and defect reconstruction. Perioperative metrics, surgical accuracy, and complications were compared between groups using Welch's t-test and the Hodges-Lehmann method; oncologic events during follow-up were recorded descriptively. RESULTS: The 3D-printing group demonstrated significantly shorter operative time (456.5&#x2009;&#xb1;&#x2009;62.36 vs. 574.44&#x2009;&#xb1;&#x2009;114.58&#x2009;min, p&#x2009;=&#x2009;0.012), reduced blood loss (4081.40&#x2009;&#xb1;&#x2009;838.99 vs. 5090.0&#x2009;&#xb1;&#x2009;1059.67&#x2009;mL, p&#x2009;=&#x2009;0.034), and fewer fluoroscopic exposures (4.2&#x2009;&#xb1;&#x2009;0.79 vs. 10.0&#x2009;&#xb1;&#x2009;1.58, p&#x2009;<&#x2009;0.001) compared with the conventional group. Osteotomy accuracy was also superior in the 3D-printing group, with significantly lower angular deviation (3.33&#xb0;&#x2009;&#xb1;&#x2009;0.45&#xb0; vs. 6.79&#xb0;&#x2009;&#xb1;&#x2009;2.16&#xb0;, p&#x2009;=&#x2009;0.0012). Postoperative complication rates were comparable (30% vs. 44.4%, p&#x2009;=&#x2009;0.649), but hospital stay was significantly shorter in the 3D-printing group (10.7&#x2009;&#xb1;&#x2009;2.71 vs. 18.11&#x2009;&#xb1;&#x2009;4.01&#x2009;days, p&#x2009;<&#x2009;0.001). CONCLUSION: Patient-specific 3D-printed guiding templates enhance precision in sacral tumor excision and reconstruction, improving surgical efficiency and perioperative safety. This computer-assisted, template-guided approach represents a valuable advancement for complex sacral oncologic surgery.

Humans

Retrograde intrarenal surgery with flexible and navigable suction access sheaths vs mini-percutaneous nephrolithotomy for large upper urinary tract stones: a&#xa0;systematic review and meta-analysis.

OBJECTIVE: To conduct a meta-analysis comparing the efficacy and perioperative outcomes of contemporary flexible and navigable suction access sheath-assisted retrograde intrarenal surgery (FANS-RIRS) against percutaneous nephrolithotomy (PCNL) for the management of large upper urinary tract stones, as despite technological advances in RIRS such as high-powered lasers and FANS that have substantially enhanced its performance, current guidelines continue to recommend&#x2009;PCNL as first-line treatment for renal stones >2cm. METHODS: MEDLINE, Embase, and the Cochrane Library were searched for studies performing direct comparisons of FANS-RIRS against PCNL in adult patients until September 2025. Primary outcomes included stone-free rates (SFRs) and need for ancillary procedures. Secondary outcomes included operative time, length of postoperative hospitalisation, and postoperative complications. RESULTS: A total of 10 studies (three randomised control trials, seven retrospective cohort studies) comprising 2347 patients were included; preoperative stone sizes were predominantly 2-3&#x2009;cm. All PCNL procedures in the studies included were performed as mini-PCNL. The SFRs for FANS-RIRS were comparable with mini-PCNL across all stone sizes (odds ratio [OR] 0.90, 95% confidence interval [CI] 0.70-1.17) and stones &#x2265;2&#x2009;cm (OR 0.80, 95% CI 0.60-1.08), with low heterogeneity. Ancillary procedures rates were similar (OR 1.22, 95% CI 0.61-2.44). FANS-RIRS was associated with significantly fewer overall complications, specifically smaller haemoglobin decline, need for transfusion, and shorter hospital stay. However, mini-PCNL demonstrated shorter operative times for stones &#x2265;2&#x2009;cm. Urosepsis rates were low and similar between both groups. Limitations include predominance of Asian studies, variability of practice, and inclusion of non-randomised studies. CONCLUSIONS: Contemporary FANS-RIRS achieves SFRs comparable to mini-PCNL even for 2-3&#x2009;cm stones, while offering superior safety profiles and shorter hospitalisation; this supports FANS-RIRS as a viable primary treatment in selected patients.

Humans

K-wire versus screw fixation in Scarf-Akin osteotomy for hallux valgus: A retrospective cohort study.

BACKGROUND: Retention of metal implants after Scarf-Akin osteotomy (SAO) may cause irritation and psychological discomfort, often necessitating a hardware removal procedure. This study aimed to introduce K-wire fixation, allowing for outpatient removal, and to compare it with screw fixation. METHODS: This retrospective study included 64 patients with hallux valgus, comprising 32 in the K-wire fixation group and 32 in the screw fixation group. Clinical outcomes were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) score, visual analogue scale (VAS), and patient satisfaction. Radiographic parameters included hallux valgus angle(HVA), intermetatarsal angle(IMA), and distal metatarsal articular angle(DMAA). RESULTS: Both groups showed significant clinical and radiographic improvement (P&#x202f;<&#x202f;0.01). No significant between-group differences were observed in the other clinical or radiographic outcomes (P&#x202f;>&#x202f;0.05). Treatment costs were significantly lower in the K-wire group (P&#x202f;<&#x202f;0.001). CONCLUSIONS: K-wire fixation provides clinical and radiographic outcomes comparable to screw fixation, while avoiding the need for an additional procedure to remove the implant. LEVEL OF EVIDENCE: Level III.

Humans

Comparative efficacy of percutaneous vertebroplasty combined with minimally invasive pedicle screw fixation versus percutaneous vertebroplasty alone in the treatment of elderly osteoporotic vertebral compression fractures.

The study aimed to assess the comparative efficacy of percutaneous vertebroplasty (PVP) combined with minimally invasive pedicle screw fixation versus PVP alone in elderly patients with osteoporotic vertebral compression fractures (OVCF). Ninety-four elderly patients with OVCF were randomly classified into the control (47 patients) and combined (47 patients) groups. The control group received PVP, while the combined group received PVP combined with minimally invasive pedicle screw fixation. Perioperative indicators such as intraoperative blood lose, operative time, and hospitalization time were recorded. Pain was assessed using the VAS before and at baseline and 1, 3, and 7 days postoperatively. At 1 and 3 days postoperatively, Serum CRP levels, WBC, and neutrophil counts were measured postoperatively. Radiographic outcomes (vertebral height ratio and Cobb angle), ADL scores, JOA scores, and ODI were evaluated preoperatively and at 3 months post-operation. Postoperative complications were documented. Baseline characteristics were comparable. The combined group showed superior pain relief, vertebral height restoration, Cobb angle correction, functional recovery, and reduced inflammatory markers (CRP, WBC, neutrophils) postoperatively (all P&#x2009;<&#x2009;0.05). Blood loss and hospital stay were shorter in the combined group, though operative time was longer (P&#x2009;<&#x2009;0.05). Complication rates did not differ significantly (P&#x2009;>&#x2009;0.05). PVP combined with minimally invasive pedicle screw fixation yields better outcomes in elderly OVCF patients by enhancing pain control, vertebral height, and functional recovery without increasing perioperative risk.

Humans

Bioabsorbable vs. titanium screws in first metatarsophalangeal joint arthrodesis: a pilot randomized controlled trial with 2-year follow-up.

INTRODUCTION: To assess the feasibility and preliminary clinical outcomes of bioabsorbable screw fixation in first metatarsophalangeal joint arthrodesis compared to conventional titanium screw fixation. METHODS: In this prospective pilot randomized controlled trial, 30 patients were allocated 1:1 to bioabsorbable or titanium cannulated lag screw fixation. Arthrodesis was performed using a cup-and-cone technique at two Finnish hospitals. Full weight-bearing in an orthopaedic shoe was allowed after six weeks. Outcomes included AOFAS and VA-FAS FA-VAS scores, union rates, and complications assessed at 3, 6, 12, and 24 months. RESULTS: Both groups showed significant functional improvement with no between-group differences. At 24 months, mean AOFAS scores were 89.1 (SD 2.7) in the titanium group and 90.0 (SD 0.0) in the bioabsorbable group (p = 0.23). Mean FA-VAS total scores (sum of pain, function, and complaints subscales) were 1948 (SE 59.4) in the titanium group and 1914 (SE 61.4) in the bioabsorbable group (p = 0.655). Union rate was 90% overall; nonunion occurred in one titanium and two bioabsorbable patients, all requiring revision. No implant-related complications or hardware removal surgeries were recorded. Degradation of bioabsorbable screws caused no adverse clinical or radiographic reactions. CONCLUSIONS: Bioabsorbable screws appear safe and feasible in first metatarsophalangeal joint arthrodesis, with preliminary outcomes comparable to titanium fixation. These findings support the conduct of a larger confirmatory trial. TRIAL REGISTRATION: ClinicalTrials.gov, NCT03133039, registered 28 April 2017. https://clinicaltrials.gov/ct2/show/NCT03133039.

Humans

Vaginal Hysterectomy Versus Vaginal Assisted Natural Orifice Transluminal Endoscopic Surgery Hysterectomy; Results of a Randomised Controlled Trial.

OBJECTIVE: To compare Vaginal Hysterectomy (VH) with Vaginal Assisted Natural Orifice Transluminal Endoscopic Surgery (NOTES) hysterectomy (VANH) as a day-care procedure. DESIGN: Single-blind, multicentre randomised controlled trial. SETTING: Two Dutch non-academic teaching hospitals. POPULATION: Women aged &#x2265;&#x2009;18&#x2009;years undergoing hysterectomy for benign indications. METHODS: Women were randomised 1:2 (VH or VANH). Primary outcome was SDD. Secondary outcomes included operative time, rate of elective salpingectomies, intraoperative blood loss, complications (Clavien-Dindo), pain scores (NRS) and analgesic use, post-operative recovery (RI-10), and quality of life (EQ-5D-5L). Analyses were performed on an intention-to-treat basis. RESULTS: A total of 113 patients were included in the analyses (n&#x2009;=&#x2009;42 VH, and n&#x2009;=&#x2009;71 VANH). SDD occurred significantly more frequently in the VANH group (87.3%) than VH group (71.4%; OR 2.76, 95% CI 1.04-7.25; p&#x2009;=&#x2009;0.04). VANH was associated with a significantly shorter operative time (median 55&#x2009;min versus 65&#x2009;min; p&#x2009;=&#x2009;0.005), less blood loss (median 50&#x2009;mL vs. 150&#x2009;mL; p&#x2009;<&#x2009;0.001) and more often elective opportunistic salpingectomy compared to VH (100% vs. 77.4%; p&#x2009;=&#x2009;0.008). NRS were significantly lower in the VANH group the first hour post-operative (3 vs. 1, p&#x2009;<&#x2009;0.001). Post-operative complications (VH 9.5% vs. VANH 15.5%; p&#x2009;=&#x2009;0.34), readmission (VH 4.8% vs. VANH 8.5%; p&#x2009;=&#x2009;0.47), analgesic use, recovery, and quality of life were not statistically significant. CONCLUSIONS: VANH is a safe and effective alternative to VH, offering a higher likelihood of SDD, shorter operative time, reduced blood loss, and more often an elective salpingectomy, without increased complications or differences in pain, recovery, or quality of life.

Humans

Oblique Lateral Interbody Fusion With Lateral Vertebral Screw Fixation Versus Transforaminal Lumbar Interbody Fusion for Severe Lumbar Stenosis: Results of a Multicenter Randomized Controlled Trial.

BACKGROUND AND OBJECTIVES: The benefits of oblique lateral interbody fusion (OLIF) vs transforaminal lumbar interbody fusion (TLIF) in severe lumbar stenosis (Schizas C/D) remain uncertain. This randomized trial compared clinical, radiographic, and safety outcomes of OLIF and TLIF. METHODS: From November 2018 to December 2021, a prospective, multicenter, randomized controlled trial enrolled 260 adults with single-level severe stenosis and instability. In total, 224 patients were randomized to OLIF or TLIF. Prespecified outcomes followed consolidated standards of reporting trials. Primary outcomes were visual analog scale back/leg pain and Oswestry Disability Index (ODI), with minimal clinically important difference thresholds of ODI &#x2265;12-13 points or &#x2265;30% improvement, and visual analog scale &#x2265;1.5-2.0 points. Radiographic measures included disc height, lumbar and segmental lordosis, and canal cross-sectional area (CSA). Complications were recorded. Ethics approval was obtained from the institutional review board, the trial was registered with ISRCTN.com , and all patients provided written informed consent. RESULTS: In total, 224 patients were randomized, 5 were lost to follow-up (TLIF n = 2, OLIF n = 3). Baseline features were comparable. OLIF was associated with shorter operative time, less blood loss, earlier ambulation, and shorter hospital stay (all P < .05). Both groups achieved significant, clinically meaningful improvements. OLIF showed greater back pain reduction at 3-6 months and 2 years ( P < .05) and superior ODI improvement at 3 and 6 months ( P < .001), although long-term ODI scores were similar. Radiographically, OLIF provided greater restoration of disc height and segmental lordosis (all P < .001) and demonstrated progressive CSA increase (dynamic decompression), whereas TLIF achieved immediate, sustained CSA enlargement. Fusion rates were comparable at 1-2 years. Complication rates were low and similar (7.3% TLIF vs 5.5% OLIF), with most OLIF-specific events transient. CONCLUSION: Both OLIF and TLIF yield improvements in severe lumbar stenosis. OLIF offers perioperative advantages, earlier functional recovery, radiographic restoration, and dynamic canal remodeling, supporting its role as an equivalent alternative for lumbar spinal stenosis with some secondary advantages.

Humans

Efficacy and Safety of Mechanical Insufflation-Exsufflation in Invasively Ventilated Critically Ill Adults: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.

BACKGROUND: Mechanical insufflation-exsufflation (MI-E) is increasingly used in invasively ventilated adults in the intensive care unit (ICU), yet its therapeutic efficacy and safety remain uncertain due to inconsistent evidence. AIM: To synthesize evidence on the clinical efficacy and safety of MI-E in this population and to examine methodological and clinical heterogeneity underlying reported outcomes. STUDY DESIGN: A systematic review and meta-analysis of randomized studies (including RCTs and randomized crossover trials), conducted following PRISMA guidelines, with risk of bias assessed using the Cochrane risk-of-bias tool. RESULTS: Five randomized controlled trials involving 310 patients were included. Meta-analysis showed that mechanical insufflation-exsufflation (MI-E) significantly increased sputum clearance (SMD&#x2009;=&#x2009;0.63, 95% CI, 0.32-0.93; p&#x2009;<&#x2009;0.00011; I2&#x2009;=&#x2009;38%) without affecting oxygenation (MD&#x2009;=&#x2009;0.28, 95% CI, -0.53 to 1.09; p&#x2009;=&#x2009;0.50; I2&#x2009;=&#x2009;9%). Data on respiratory mechanics, ventilation duration and ICU stay could not be pooled. No serious adverse events were reported. CONCLUSIONS: MI-E significantly improves sputum clearance in invasively ventilated critically ill adults, with no severe adverse events reported in the included studies. Its effects on other outcomes remain inconclusive due to limited data and heterogeneity. Standardized protocols and larger trials are needed. RELEVANCE TO CLINICAL PRACTICE: Clinicians may consider MI-E as an adjunct for respiratory secretion management. Application should be guided by structured patient assessment and individualized parameter adjustment. Future research should standardize interventions and target well-defined patient subgroups to inform clear practice guidelines. TRIAL REGISTRATION: The review protocol was registered in the International Prospective Register of Systematic Reviews, with registration number CRD42023403299.

Humans

Comparison of three tracking methods to assess usage of two pediatric powered mobility devices for young children with cerebral palsy.

Powered mobility devices are underutilized for promoting self-initiated mobility in young children with cerebral palsy due to prioritization of walking, caregiver effort, device characteristics, and environmental factors. Understanding device usage patterns is important to assess the impact of powered mobility interventions on child outcomes. As part of clinical trial (NCT04684576), three objective tracking methods including integrated loggers, Global Positioning System trackers (GPST), and caregiver reported activity logs (CRAL) were compared to provide insights into device usage patterns. Metrics included play session frequency, session duration, total usage minutes, and unique usage days for two powered mobility devices: Modified Ride-on Cars (MROC) and the Permobil Explorer Mini (EM). Twelve children with cerebral palsy used each device for eight consecutive weeks in home and community settings (16&#x2009;weeks total), with device ordered randomized. Results showed no significant differences among tracking methods for the MROC. For the EM, only session duration differed between GPST and CRAL. Correlation analysis revealed variable relationships amongst tracking methods for both devices. The EM was used more frequently than the MROC, with significantly greater total usage minutes and session duration via CRAL, not GPST. The findings highlight the need for reliable tracking technologies that can be used across powered mobility devices.

Child, Preschool

Hip Arthroscopy-Assisted Management of Pipkin Types I and II Femoral Head Fracture-Dislocations: Mid-Term Clinical and Radiographic Outcomes.

OBJECTIVES: Hip arthroscopy-assisted surgery has been proposed as a minimally invasive option for femoral head fractures; however, evidence with mid-term follow-up remains limited. This study aimed to evaluate the clinical and radiographic outcomes of arthroscopy-assisted management for Pipkin Types I and II femoral head fracture-dislocations with a minimum follow-up of 5&#x2009;years. METHODS: This retrospective study included 23 consecutive adults (19 Pipkin I and 4 Pipkin II) treated with hip arthroscopy-assisted fragment excision or internal fixation between March 2013 and January 2020. Preoperative computed tomography was used for surgical planning, and fixation was placed with arthroscopic headless screws. Clinical outcomes were assessed using the Harris Hip Score (HHS) and Thompson-Epstein (T-E) criteria. Radiographic evaluation included avascular necrosis (AVN), heterotopic ossification (HO; Brooker), osteoarthritis (OA; T&#xf6;nnis), and fracture reduction quality (Matta's criteria). Group comparisons were evaluated using independent samples t-tests, Mann-Whitney U tests, and Fisher's exact test. The mean follow-up was 86.2&#x2009;&#xb1;&#x2009;21.2&#x2009;months. RESULTS: The cohort consisted of 19 males and 4 females with a mean age of 28.7&#x2009;&#xb1;&#x2009;9.9&#x2009;years. Fifteen patients underwent fixation and eight underwent excision. The final mean HHS was 98.3&#x2009;&#xb1;&#x2009;1.9, with 21 patients (91%) achieving excellent and 2 (9%) good T-E criteria. There were no significant differences between the fixation and excision groups in demographic characteristics, operative time, or functional outcomes (all p&#x2009;>&#x2009;0.05); however, hospital stay was significantly shorter in the excision group (2.9&#x2009;&#xb1;&#x2009;0.6 vs. 5.5&#x2009;&#xb1;&#x2009;4.6&#x2009;days, p&#x2009;=&#x2009;0.028). In the fixation group, mean maximal displacement improved from 7.6&#x2009;mm preoperatively to 2.6&#x2009;mm postoperatively, with anatomic reduction achieved in 6 cases (40%), imperfect in 6 (40%), and poor in 3 (20%). Patients with Pipkin Type I fractures had significantly higher HHS than those with Type II fractures (98.7&#x2009;&#xb1;&#x2009;1.7 vs. 96.0&#x2009;&#xb1;&#x2009;0.8, p&#x2009;=&#x2009;0.018). Complications were rare, with one case of Brooker Grade I HO and one case of mild OA. No AVN or total hip arthroplasty occurred during the follow-up. CONCLUSIONS: Hip arthroscopy-assisted management of selected Pipkin Type I and II femoral head fractures yields excellent mid-term clinical outcomes with acceptable radiographic reduction and a low complication rate. This minimally invasive technique represents a viable alternative in appropriately selected patients when fragment characteristics and surgical expertise permit.

Humans

Chalcone-indole hybrid scaffolds as promising anticancer drug candidates: a mini-review.

Cancer treatment is hampered by severe systemic side effects, poor tumor selectivity, and multidrug resistance (MDR). Molecular hybridization integrates chalcone and indole, two privileged antitumor pharmacophores, into one scaffold to generate chalcone-indole hybrids that synergistically enhance antitumor potency, improve tumor targeting, and reverse MDR. This mini-review analyzes literature from 2020 to 2026 on chalcone-indole anticancer hybrids. Based on structural modification patterns, the reported hybrids are categorized into four subgroups: simple substituted, &#x3b1;/&#x3b2;-position modified, N-1 fatty acid-substituted, and multi-pharmacophore fused hybrids. For each category, we summarize structure-activity relationships (SARs), antiproliferative activity, selective toxicity, molecular mechanisms, and in vivo xenograft performance. Most lead compounds exert tumor-suppressive effects via tubulin polymerization inhibition, G2/M cell cycle arrest, ROS overaccumulation, and mitochondrial-dependent apoptosis. Representative hybrids 10a, 12a, 21a, and 25a exhibit remarkable efficacy against drug-resistant colorectal, lung, and breast tumors with favorable in vivo safety. We highlight the application potential of different subtypes for specific malignancies, including &#x3b1;/&#x3b2;-modified analogues for resistant colorectal cancer, N-1 fatty acid-platinum conjugates for platinum-resistant lung cancer, NLRP3 inhibitor 7a for oral cancer, and multi-pharmacophore fused derivatives for broad-spectrum activity. Current bottlenecks limiting clinical transformation are discussed. This review provides structural design rules for developing novel chalcone-indole targeted anticancer agents.

Humans

New World screwworm: a re-emerging parasitic threat.

PURPOSE OF REVIEW: New World screwworm (NWS) is an emerging parasitic threat in Central America and Mexico, which is spreading northward into the southern United States. Here we highlight the changing epidemiology, lifecycle of the NWS fly, clinical presentation, identification, treatment, and potential complications of NWS myiasis. RECENT FINDINGS: Despite decades of successfully containing NWS flies south of the Darien Gap in southern Panama, NWS flies reemerged in the Central America region in 2023 and have continued to spread northward ever since. On 3 June 2026, United States Department of Agriculture (USDA) confirmed the identification of an NWS infestation in a young calf in southern Texas. In addition to describing the current epidemiology of the NWS outbreak, we present information about clinical presentation and management of NWS myiasis in patients and include representative cases of patients who experienced NWS myiasis. SUMMARY: This review provides important epidemiologic and clinical updates to an emerging parasitic threat so clinicians can understand the risks and clinical management for patients with suspected NWS myiasis.

Animals

F-URS with FANS versus mPCNL for 2-3&#x2009;cm UUTS: a RCT with a subgroup analysis of 2-2.5&#x2009;cm stones.

OBJECTIVE: To evaluate the safety and efficacy of flexible ureteroscopy (f-URS) with a flexible and navigable suction ureteral access sheath (FANS) compared with mini-percutaneous nephrolithotomy (mPCNL) in the treatment of 2-3&#x2009;cm upper urinary tract stones (UUTS), with a prespecified subgroup analysis for stones &#x2265;2 to <2.5&#x2009;cm. METHODS: This randomized controlled trial enrolled 326 patients with 2-3&#x2009;cm UUTS between June 2023 and December 2025. Patients were randomly assigned in a 1:1 ratio to undergo either f-URS with FANS or mPCNL. A prespecified subgroup analysis was conducted for stones measuring &#x2265;2 to <2.5&#x2009;cm. The primary outcomes were the immediate and 1-month stone-free rate (SFR). Secondary outcomes included the operative duration, decrease in haemoglobin, hospital stay, and complication rate. RESULTS: The baseline characteristics were comparable between the two groups. In the overall 2-3&#x2009;cm cohort, the FANS group achieved immediate and 1-month SFRs comparable to those of the mPCNL group. Although the operative time was longer in the FANS group, it was associated with significantly less haemoglobin loss and a shorter hospital stay, with no significant difference in infection-related complications. Notably, in the subgroup of stones &#x2265;2 to <2.5&#x2009;cm, the FANS group demonstrated a non-inferior SFR at both time points, and the operative time was not significantly longer than that of the mPCNL group. CONCLUSION: For 2-3&#x2009;cm UUTS, f-URS with FANS offers a SFR comparable to that of mPCNL, along with the advantages of reduced blood loss and shorter hospitalization. In the &#x2265;2 to <2.5&#x2009;cm subgroup, FANS shows comprehensive benefits over mPCNL. These findings support FANS as an effective alternative to mPCNL for 2-3&#x2009;cm stones and a potentially preferred option for stones measuring 2-2.5&#x2009;cm.

Humans

Unraveling a Diagnostic Enigma: A TECPR2 Case Solved Through Multi-Omic Genomics.

TECPR2 is a key regulator of autophagy, encoded by the TECPR2 gene. Pathogenic variants in this gene have been linked to a rare hereditary sensory and autonomic neuropathy with intellectual disability (HSAN9). We report a teenage female with a syndromic intellectual disability disorder associated with neuromuscular abnormalities. Multi-omics analysis including genomics, transcriptomics, and proteomics, together with muscle biopsy from the affected individual, were used in this clinical case. Through trio exome sequencing we identified two heterozygous variants in the TECPR2 gene, NM_014844.4: c.480G>A; p.(Gln160=) and c.2846C>A; p.(Ala949Glu). Both were classified as variants of uncertain significance due to the lack of supporting evidence for pathogenicity. Subsequent long-read sequencing phased the variants and confirmed they were in trans. Additional functional studies using RNAseq and proteomics analyses verified the pathogenicity of the variants. This case study demonstrated the value of a multi-omics assisted analysis, which complemented the traditional phenotype-first approach in reaching a definitive clinical diagnosis.

Humans

Comparison of short-term clinical outcomes and patient satisfaction between intraoral scanning and conventional impressions for complete-arch implant prostheses: a pilot RCT.

OBJECTIVE: To compare framework passive fit, subjective evaluations, and short-term clinical outcomes between conventional impressions (CI) and intraoral scanning (IOS) for complete-arch implant-supported fixed dental prostheses (CIFDPs). METHODS: In this randomized controlled trial, 22 patients were allocated to the CI or IOS groups. All participants received a definitive one-piece CIFDP. The primary outcome was framework passive fit, assessed using the Vision and Tactile Score (V&T score), which included framework lift-off, the single-screw test, the full-screw test, smoothness of screw insertion, and radiographic gap assessment. Secondary outcomes included operator evaluation, patient satisfaction using a visual analog scale (VAS), early implant survival, marginal bone loss (MBL), modified Plaque Index (mPII), and complications at the 6-month follow-up. RESULTS: Twenty-two patients were enrolled (CI: n = 11; IOS: n = 11), and one patient in the CI group was lost to follow-up. No statistically significant difference in the V&T score was observed between the CI and IOS groups (4.66 &#xb1; 0.17 vs. 4.65 &#xb1; 0.28; P = 0.93). The operator reported greater nervousness during the CI procedure than during IOS (21.82 &#xb1; 15.69 vs. 8.64 &#xb1; 7.47; P < 0.05). Patients in the CI group reported significantly greater discomfort, including nausea and anxiety, than those in the IOS group (P < 0.05). At the 6-month follow-up, the early implant survival rate was 100% in both groups. No significant differences were found between the groups in MBL (0.09 &#xb1; 0.09 vs. 0.06 &#xb1; 0.10 mm; P = 0.43) or mPII (0.10 &#xb1; 0.12 vs. 0.10 &#xb1; 0.28; P = 0.99). CONCLUSION: IOS and CI achieved comparable short-term clinical outcomes in patients who met the predefined inclusion criteria, including controlled implant number, spacing, and angulation. IOS provided a more favorable experience for both operators and patients. CLINICAL SIGNIFICANCE: In complete-arch implant restorations, intraoral scanning may provide clinical outcomes comparable to those of conventional impressions while improving patient comfort.

Humans