Search PubMedSearch

SEARCH · Search PubMed

Results for “Reproducibility”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

58 recordsLinked to original sources

Mitigating pH-induced instability in deruxtecan-based ADCs: an onboard-mixing icIEF approach for robust charge heterogeneity characterization.

Accurate charge variant analysis of antibody-drug conjugates (ADCs) is essential for understanding product heterogeneity and ensuring quality control. However, Deruxtecan (DXd)-based ADCs present a unique analytical challenge due to the intrinsic instability of the payload, where the lactone ring readily undergoes hydrolysis under alkaline conditions, resulting in time-dependent shifts in charge distribution during imaged capillary isoelectric focusing (icIEF). In this study, we describe the development of an onboard-mixing icIEF method designed to minimize pH-induced degradation during sample preparation. By separating ADC samples from carrier ampholytes (CAs) prior to injection and enabling real-time mixing within the instrument, this approach effectively suppresses premature lactone ring opening and stabilizes charge variant profiles. Comparative studies between conventional premixing and onboard-mixing approach demonstrated that the latter significantly enhances reproducibility, particularly for acidic variants that are highly sensitive to structural conversion. Comprehensive method validation confirmed excellent precision, linearity, and sensitivity, with consistent performance across run-to-run and intra-day analyses. The results underscore the importance of controlling microenvironmental pH exposure in the analysis of chemically instable ADCs. The proposed onboard-mixing strategy provides a robust and efficient solution for icIEF-based characterization, reducing analytical artifacts while simplifying method development. This approach is broadly applicable to ADCs and other biotherapeutics containing pH-sensitive functional groups.

Hydrogen-Ion Concentration

A streamlined workflow for high throughput metaproteomic analysis of the rumen microbiome.

Metaproteomics can provide direct functional insights into complex microbial communities, yet its application in rumen research remains limited due to labor-intensive and low-throughput sample preparation workflows before the MS analysis. This work aimed to develop and characterize a streamlined, high throughput metaproteomic workflow optimized for rumen samples. Key steps, including microbial cell extraction, cell lysis, protein digestion, and LC-MS/MS acquisition, were systematically assessed and optimized to reduce hands-on time while maintaining deep proteome coverage. The optimized workflow integrates a minimized cell extraction protocol using 0.5 g starting material and in-solution tryptic digestion. Application of the final workflow to 72 samples from in vitro fermentation revealed that biological variability between inocula dominated technical variability, which remained moderate (median CV of 21-24% across batches). Overall, the optimized workflow supports robust taxonomic and functional characterization of the rumen microbiome with improved scalability. These advances provide a foundation for applying metaproteomics to larger experimental designs, including nutritional trials and cohort studies, thereby enabling broader functional interrogation of rumen microbial ecosystems. SIGNIFICANCE: This study addresses current limitations in the application of metaproteomics to rumen microbiome research by developing a streamlined and scalable sample preparation workflow. By optimizing key steps and reducing sample input while maintaining reproducibility and proteome coverage, this work enables more efficient processing of larger sample sets. These advances support the broader use of metaproteomics in rumen studies and facilitate functional investigations relevant to animal nutrition and sustainable livestock production.

Animals

Transcranial Photobiomodulation Variables Assessment Battery: Development and Validation.

Transcranial photobiomodulation (tPBM) response variability is partly driven by biophysical characteristics such as skin tone and hair properties that attenuate photon penetration, and by lifestyle factors including sleep quality, alcohol use, and nicotine consumption that disrupt the mitochondrial and vascular pathways on which tPBM acts. To date, no validated self-report tool exists to capture these moderators systematically. To address this gap, the tPBM Variables Assessment Battery was developed and psychometrically evaluated. It integrates adapted versions of established measures (Brief Pittsburgh Sleep Quality Index, E-cigarette Dependence Scale, Hair Scale Assessment PRO, Monk Skin Tone Scale, and Heaviness of Smoking Index), validated wellbeing evaluators (Ryff's Psychological Wellbeing), and custom measures (Hairstyle Classification, Hair Color Classification). Face and content validity met recommended expert thresholds, internal consistency was acceptable across adapted subscales, and criterion validity analyses confirmed meaningful associations between the lifestyle components and PROMIS-10 global health outcomes. The battery is low-burden, digitally deployable, and psychometrically defensible, offering a practical tool for characterizing the variables most likely to moderate tPBM response in home-use studies.

Humans

A smartphone-integrated Pt@Cu-HCF nanozyme-based paper sensor for on-site determination of total antioxidant capacity in marine oils.

Total antioxidant capacity (TAC) serves as a key indicator for evaluating the nutritional quality of foods. In this study, we designed a platinum-embedded copper hexacyanoferrate (denoted as Pt@Cu-HCF) nanozyme that exhibits high oxidase-like activity, efficiently catalyzing the oxidation of chromogenic substrates to generate robust colorimetric signals. Antioxidants quench hydroxyl radicals (∙OH) produced during the catalytic process, leading to a concentration-dependent suppression of the color signal. Leveraging this mechanism, a smartphone-integrated, colorimetric paper sensor for on-site TAC quantification was developed, using vitamin E as the calibration standard. The sensor was applied to determine TAC in fish oil, algal oil, and krill oil, demonstrating a linear response range of 9.78-312.5 μM and a limit of detection (LOD) of 6.41 μM. Validation using real-world marine oil samples showed excellent agreement with a commercial assay kit, confirming the reliability and practical applicability of this portable sensor for TAC measurement in complex biological matrices.

Antioxidants

Performance comparison of rapid and native barcoding methods for Oxford Nanopore sequencing of Poliovirus Viral Protein 1 (VP1) amplicons.

Accurate and timely sequencing of poliovirus is critical for global eradication efforts, particularly for molecular epidemiology based on the typing region of the genome, viral protein 1 (VP1). While Oxford Nanopore Technologies (ONT) sequencing has expanded capabilities for poliovirus surveillance, the relative performance of different ONT library preparation methods, including ligation-based (Native Barcoding) and transposase-based (Rapid Barcoding) approaches, has not been systematically evaluated. In this study, we compared rapid barcoding and native barcoding workflows for sequencing VP1 amplicons from 17 type 2 poliovirus-positive samples, each processed in triplicate. Native barcoding generated significantly more sequencing output, producing approximately 2.3-fold greater total read yield than rapid barcoding, and demonstrated higher run-to-run reproducibility (R2 = 0.979-0.998 vs. 0.847-0.929, respectively; p&#x202f;<&#x202f;0.001). In addition, native barcoding generated 80% of the total yield achieved by rapid barcoding within approximately 7&#x202f;h, whereas rapid barcoding required approximately 40&#x202f;h to reach the same output. Despite these differences, both methods produced identical VP1 consensus sequences across all samples, with comparable read quality (median per-base Q-scores of approximately Q17-Q18). Rapid barcoding provided substantial practical advantages, reducing hands-on library preparation time (55 vs. 200&#x202f;min) and per-sample cost ($12.82 vs. $16.54), while simplifying workflow and reducing technical complexity. These findings indicate that sequencing yield may not be a determinant of downstream analytical outcomes for poliovirus VP1 ONT sequencing. Rapid barcoding therefore represents a cost-effective and efficient approach for routine poliovirus surveillance, whereas native barcoding remains advantageous in applications requiring rapid data generation or maximal sequencing depth.

Poliovirus

Simultaneous determination of imiquimod and terbinafine in skin permeation studies: Validation of a liquid chromatography method with fluorescence detection.

Chromoblastomycosis is a chronic, neglected subcutaneous mycosis posing significant therapeutic challenges. A topical strategy combining terbinafine (TBF), an antifungal, with imiquimod (IMQ), a TLR-7/8 agonist immunomodulator, has emerged a promising alternative. However, no validated analytical method is currently available to simultaneously quantify both drugs in skin, which is crucial for novel formulation development. This study reports the development and validation of a simple HPLC method with fluorescence detection (excitation 236&#xa0;nm, emission 340&#xa0;nm) for the simultaneous determination of TBF and IMQ extracted from porcine skin. Separation was achieved on a C8 reversed-phase column (125&#xa0;&#xd7;&#xa0;4.0&#xa0;mm, 5&#xa0;&#x3bc;m) using a mobile phase of methanol and water (60,40, v/v), both containing 0.1% formic acid at a flow rate of 0.8&#xa0;mL/min. The method showed excellent linearity (r&#xa0;>&#xa0;0.999) over 0.01-1.0&#xa0;&#x3bc;g/mL for IMQ and 0.1-2.0&#xa0;&#x3bc;g/mL for TBF. Intra- and inter-day precision demonstrated coefficients of variation below 5%, and recovery rates from skin (79-105%) confirmed accuracy. Limits of detection were 0.001&#xa0;&#x3bc;g/mL for IMQ and 0.004&#xa0;&#x3bc;g/mL for TBF, with quantification limits of 0.02&#xa0;&#x3bc;g/mL and 0.16&#xa0;&#x3bc;g/mL, respectively. This selective, sensitive, and reproducible method represents a valuable analytical tool for supporting the development and quality control of topical formulations for chromoblastomycosis and other fungal skin diseases.

Animals

A STORM-based protocol for nanoscale imaging and quantitative analysis of protein-associated and phospholipid-associated structures in natural rubber.

Stochastic Optical Reconstruction Microscopy (STORM) enables nanoscale mapping of molecular components beyond the diffraction limit; however, its reproducible implementation in hydrophobic polymer matrices remains challenging because fluorescence-labeling specificity, fluorophore photoswitching, three-dimensional localization, chromatic registration, and quantitative image analysis must be carefully controlled. This protocol presents a standardized experimental workflow for dual-color labeling, astigmatism-based three-dimensional STORM acquisition, and quantitative analysis of protein-associated and phospholipid-associated structures in natural rubber (NR). The workflow covers sample pretreatment, Cy5 NHS ester labeling of protein-associated primary amines, DiI labeling of phospholipid-rich domains, STORM imaging-buffer preparation, three-dimensional single-molecule localization, dual-channel registration, generation of standardized xy projections, aggregate-size analysis, and projected lateral spatial correlation assessment. Reproducibility is supported by defined acquisition and localization criteria, three independent sample preparations with at least five fields of view analyzed per condition, and unlabeled, single-color, dye-only matrix, and processing-associated Cy5 controls. Mean lateral localization precisions of 11.8&#x202f;&#xb1;&#x202f;2.3&#x202f;nm for Cy5 and 13.5&#x202f;&#xb1;&#x202f;2.9&#x202f;nm for DiI were obtained, while two-dimensional Fourier ring correlation analysis of the xy projections yielded effective lateral image resolutions of approximately 25 and 28&#x202f;nm, respectively. Image-based particle segmentation and localization-coordinate-based density-based spatial clustering of applications with noise (DBSCAN) were applied to standardized xy projections as complementary quantitative approaches. Application of the protocol to untreated, centrifuged, and protease-treated NR samples demonstrated treatment-associated changes in the detected abundance and projected size distributions of protein- and phospholipid-associated aggregates, together with a non-monotonic change in their projected lateral spatial correlation. These observations describe alterations in nanoscale organization but do not, by themselves, establish stable protein-phospholipid complex formation. Unlike previous studies that primarily demonstrated the feasibility of STORM imaging in rubber materials, the principal contribution of this work is an end-to-end, step-by-step protocol incorporating defined controls, three-dimensional localization, image-quality metrics, chromatic-registration procedures, and complementary quantitative-analysis pipelines for non-expert users. The workflow may be adaptable to other hydrophobic polymers and soft-material systems after appropriate optimization and validation.

Rubber

Development and validation of a novel LC-MS/MS method for simultaneous quantification of fidaxomicin and metabolite (OP-1118) from feces for gut pharmacobiome studies.

Fidaxomicin is a first-line antibiotic for treating Clostridioides difficile infection. While it has low systemic absorption and reaches high colonic concentrations, it is hydrolyzed to a less active metabolite, OP-1118. Few studies have completely described critical experimental details of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for quantifying fecal fidaxomicin and OP-1118. This study developed and validated a simple, fast, and sensitive LC-MS/MS method to quantify fidaxomicin and OP-1118 in human and mouse feces. This method simplified fecal sample preparation without the use of solid phase extraction and optimized LC-MS/MS parameters. A broad working range (0.3-1000&#xa0;ng/ml) in both diluted human and murine fecal matrices was achieved with good intra- and inter-day accuracy (93-107%), precision (1-7%), and recovery (70-105%) as well as little IS-normalized matrix effects. This method was utilized to quantify fidaxomicin and OP-1118 in human and murine fecal samples. This novel method was simple, fast, sensitive, and accurate in analyzing fecal fidaxomicin and OP-1118 and could be deployed to facilitate gut pharmacobiome research.

Feces

Vortex-assisted liquid-liquid microextraction based on natural deep eutectic solvents for the determination of pyrethroid pesticides in urine.

A novel, facile, and environmentally friendly analytical method was developed based on vortex-assisted liquid-liquid microextraction and high-performance liquid chromatography with diode-array detection for detecting pyrethroid pesticides (PPs) in urine. Natural deep eutectic solvents (NADESs) were prepared using plant essential oil-derived monoterpenoids (thymol, carvacrol, and menthol) combined with aromatic primary alcohols (benzyl alcohol, phenethyl alcohol, and phenylpropyl alcohol) as hydrogen bond donors and acceptors. These solvents served as environmentally benign extraction media, thereby avoiding the use of conventional volatile, toxic organic solvents. NADESs are naturally derived, easy to prepare, biodegradable, and environmentally friendly solvents. Hydrophobic and &#x3c0;-&#x3c0; interactions between the NADESs and PPs may contribute to enhancing the affinity of PPs toward the NADESs phase. Vortex technology, accelerating mass transfer between the sample and extractant phases, enables fast extraction of PPs. Under optimized conditions, the method achieved a low detection limit (0.002&#xa0;mg&#xa0;L-1), satisfactory precision with relative standard deviations (0.3%-2.4%), and acceptable recovery (80.7%-86.2%). The method demonstrated excellent performance in urine analysis and was feasible as a facile and green strategy for monitoring the content of PPs in biological matrices and assessing exposure risk.

Liquid Phase Microextraction

Direct background subtraction LC-MS/MS assay for human plasma progesterone: Full validation and comparative application.

OBJECTIVE: To develop and validate a liquid chromatography-tandem mass spectrometry method based on direct background subtraction for the quantification of endogenous progesterone in human plasma. METHODS: Protein precipitation was used for sample preparation with deuterated progesterone as the internal standard. Chromatographic separation was performed on an ACQUITY C18 column using gradient elution with 0.1% formic acid in water and acetonitrile at a flow rate of 0.3&#xa0;mL/min. Mass spectrometry was operated in positive electrospray ionization mode with multiple reaction monitoring. Instead of using analyte-stripped matrix or surrogate matrix, authentic plasma was directly used for all validation experiments. Quantitation was achieved by subtracting the background signal, and results were compared with those from the classical method using stripped matrix. RESULTS: Excellent linearity was achieved over 0.1-100&#xa0;ng/mL (R2&#xa0;&#x2265;&#xa0;0.99). Precision, accuracy, recovery, matrix effect, and stability all met FDA and ICH M10 acceptance criteria. Compared with the classical method, the bias in Cmax and AUC0-t was within &#xb1;15%, indicating no significant difference between the two methods. CONCLUSION: The direct background subtraction method avoids laborious preparation of blank matrix, eliminates matrix effect discrepancies, and is simple, efficient, and low-cost. It can serve as a general strategy for endogenous substance determination.

Humans

Artificial neural network data fusion-mediated dual-mode sensor based on Fe3O4@PdIr for Salmonellatyphimurium detection in food.

Salmonella Typhimurium (S. typhimurium) is a major foodborne pathogen that poses a serious threat to public health. In this study, a colorimetric/electrochemical dual-mode biosensor assisted by artificial neural network (ANN) was developed for the sensitive detection of S. typhimurium. Fe3O4@PdIr nanocomposites with enhanced peroxidase-like activity and electrochemical performance were prepared and conjugated with an aptamer specific to S. typhimurium to obtain Fe3O4@PdIr-Apt. Through the sandwich binding of Fe3O4@PdIr-Apt and Apt to the target, the nanocomposites were attached to microplates or Au electrodes, thereby generating colorimetric and electrochemical signals. The ANN model deeply resolved the complex nonlinear relationship between the dual signals, enabling mutual correction and ultimately performing data fusion to output a single detection result, which significantly reduced the mean square error while improving detection sensitivity and reliability. This sensor exhibited a wide linear range of 2.7-2.7&#xa0;&#xd7;&#xa0;108&#xa0;CFU/mL and a low detection limit of 1.66&#xa0;CFU/mL. Additionally, this method was successfully applied to the detection of S. typhimurium in pork and milk, with a recovery rate of 95.19%&#xa0;&#x223c;&#xa0;104.07%. It indicated that the constructed sensor holds great practical potential for S. typhimurium detection.

Neural Networks, Computer

Validated UPLC-MS/MS quantification and intracellular PK-PD Modeling of periplocin-related cardiac glycosides in H/R-injured H9c2 cells.

Reliable intracellular quantification is essential for characterizing the target-site disposition and exposure-response relationships of bioactive natural products. In this study, an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous determination of periplocin and four related cardiac glycoside metabolites in H9c2 cell lysates. Acceptable linearity, precision, recovery, and stability were achieved for intracellular quantification. Cells were treated with each compound at 50&#xa0;&#x3bc;M, and intracellular concentrations and cell viability were monitored over 48&#xa0;h. In hypoxia/reoxygenation (H/R) -injured cells, the time to maximum intracellular concentration was shortened for all five compounds, indicating altered cellular disposition under injury conditions. Cell viability was improved by all compounds during the observation period. Pharmacokinetic-pharmacodynamic (PK-PD) integration was performed using a sigmoid Emax model, and acceptable model fits were obtained, with Akaike information criterion (AIC) values ranging from 79.22 to 130.46. Low apparent EC50 values were estimated under this single-dose design, whereas the estimated Ke0 values suggested delayed equilibration with the effect compartment. These findings indicate that sustained cytoprotective responses can be produced by periplocin and related metabolic markers in injured cardiomyocytes. This intracellular bioanalytical strategy provides a quantitative approach for linking cellular exposure to pharmacodynamic response and may support further evaluation of periplocin-related cardiac glycosides.

Tandem Mass Spectrometry

Specific Instruments for Caregiving Competence Among Family Caregivers of Cancer Patients: A COSMIN Systematic Review of Psychometric Properties.

OBJECTIVE: To evaluate and summarize the psychometric properties of specific instruments for caregiving competence among family caregivers of cancer patients. METHODS: Systematically searched eight databases for studies published up to November 2025. The methodological quality and psychometric properties of the instruments were evaluated using COSMIN 2.0. Evidence grades were rated using the modified GRADE system (four grades: "High," "Moderate," "Low," and "Very Low"), and recommendations were formulated (Category A: recommended, Category B: potential with further validation, and Category C: not recommended). RESULTS: Seven studies were included, comprising three specific instruments: the Care Competency Scale for Family Caregivers in Home Palliative Care (CCSHPC) (n = 1), the Caregiver Caregiving Self-Efficacy Scale-Oral Cancer (CSES-OC) (n = 1), and the Caring Ability of Family Caregivers of Patients with Cancer Scale (CAFCPCS) (n = 5). Both the CCSHPC and CAFCPCS received Category B recommendations, demonstrating "adequate" content validity with evidence grades rated "very low" and "low," respectively. The CAFCPCS also shows good structural validity ("moderate") and internal consistency ("low") in some cultural contexts. The CSES-OC is a Category C recommendation, with high-quality evidence indicating "inadequate" criterion validity. CONCLUSION: Few specific instruments exist, and most did not strictly follow COSMIN guidelines. The CAFCPCS is provisionally recommended based on relative evidence superiority rather than complete psychometric validation. Further cross-cultural and localized instrument development is warranted. IMPLICATIONS FOR NURSING PRACTICE: Use well-validated specific instruments to identify strengths and weaknesses in the caregiving competencies of family caregivers of cancer patients, enabling them to deliver high-quality home-based cancer care.

Female

Quantifying the aromatic amino acid metabolome: UPLC-MS/MS analysis of aromatic amino acids and their host and co-metabolites in plasma.

Aromatic amino acids (AAAs), tryptophan, phenylalanine, and tyrosine along with their pathway metabolites have been implicated in the pathogenesis of diseases ranging from cardiovascular, neurological, inflammatory, and cancer diseases, among others. As such, the measurement of the primary AAAs, their host pathway metabolites, and microbiome derived co-metabolites in blood can provide a sensitive reflection of systemic health. The aim of the study was to develop a method for the quantification of 17 metabolites, the three AAAs and various of their metabolites in plasma using a high-throughput ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method. The method demonstrated a dynamic range (1 to 16,700&#xa0;ng/mL), with detection limits (LOD) as low as 0.05&#xa0;ng/mL. Quantification limits ranged from 3 to 5019&#xa0;ng/mL (LLOQ) and up to 16,700&#xa0;ng/mL (ULOQ). Recovery at LQC, MQC, and HQC was satisfactory and consistent across most metabolites, with significant matrix effects observed only for 4-ethylphenol sulfate. Furthermore, intra and inter-day accuracy and precision met all acceptance criteria at all quality control concentrations for most of the metabolites. Measurement of NIST SRM 1950 showcased the method's accuracy for most of the metabolites. Finally, the method was applied on the analysis of plasma samples from 55 individuals (13 males and 42 females) providing information on AAAs and their pathway metabolites relevant concentrations in human plasma.

Amino Acids, Aromatic

Improved comprehensive profiling of fecal bile acids through chemical derivatization combined with HPLC-MS/MS analysis.

Bile acids (BAs) facilitate the digestion and absorption of fats and influence lipid and glucose homeostasis, making them potential therapeutic targets for obesity and related metabolic disorders. The liver and intestinal microbiota modify BAs structurally, generating diverse chemical forms and isomers. Comprehensive profiling of the BA pool is critical for understanding their key biological functions and as a therapeutic approach for related diseases. High-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) is usually chosen as the preferred method for BA detection due to the complex chemical structures, the wide range of actual concentrations and the complexity of fecal sample matrices. However, free BAs are difficult to ionize, resulting in low detection signals and a lack of characteristic structural fragments to assist in structural identification. In this method, the labeling reagent (2-aminoethyl) trimethylammonium (AETMA) is employed to label the carboxyl group of BAs. Compared with underivatized BAs, the detection sensitivity of unconjugated BAs was enhanced by 25-180 fold, while that of conjugated BAs increased by 6-160 fold. It also generates unique fragment ions and enhances MS response, facilitating the discovery of potential BAs. Methodological parameters were validated using 38 BAs as representatives. Through methodological validation, it was verified that the precision, recovery, matrix effect and stability parameters of the method met acceptable criteria. We also identified 61 confirmed BAs and 55 additional candidate BAs in human pooled fecal samples. It has been successfully applied to fecal BA analysis in obese populations, providing valuable insights into potential therapeutic strategies for obesity.

Tandem Mass Spectrometry

Axial Length Adjustment and AL/R Ratio Optimization of IOL Power Calculation in Extremely Long Eyes.

PURPOSE: To evaluate the accuracy of modern intraocular lens (IOL) power calculation formulas and axial length (AL) adjustment methods in eyes with AL &#x2265; 30.0 mm. DESIGN: Retrospective consecutive cross-sectional study. PARTICIPANTS AND CONTROLS: A total of 308 eyes (308 patients) with AL &#x2265; 30.00 mm were included. METHODS: Accuracy of modern online formulas, alone or with established AL adjustments methods, was analyzed. Subgroup analyses were performed based on AL, keratometry (K), anterior chamber depth (ACD), lens thickness (LT), and AL-to-corneal radius (AL/R) ratio. MAIN OUTCOME MEASURES: Predictive accuracy was evaluated using the formula performance index (FPI), root mean square absolute prediction error (RMSAE), standard deviation (SD) of prediction error (PE), and percentage of eyes within &#xb1;0.25 and &#xb1;0.50 diopters (D). RESULTS: Overall, Holladay 1 combined with the nonlinear polynomial Wang-Koch axial length adjustment (H1-PWK) demonstrated the best overall performance, achieving the lowest SD (0.40), RMSAE (0.40), and highest FPI (0.494). A tendency toward hyperopic error was observed in eyes with AL &#x2265; 32.0 mm, K &#x2265; 46.0 D. The AL/R ratio showed a significant positive correlation with PE in the Ladas Super formula, Barrett Universal II, EVO, PEARL-DGS, and Hoffer QST formulas. Spline-based regression analysis indicated that the transition point of AL/R from myopic to hyperopic PE varied across different formulas. CONCLUSIONS: H1-PWK provides robust refractive accuracy in extremely long eyes. The AL/R ratio may provide a useful composite biometric stratification parameter compared to AL alone.

Humans

A versatile reversed-phase liquid chromatography charged aerosol detection method for streamlined monitoring of QS-21 content and stability in liposomal adjuvant formulations.

Identifying and quantifying an active adjuvant along with its degradants in drug formulations is essential for ensuring the safety and efficacy of the drug product. QS-21 is a potent adjuvant that is being evaluated in several clinical trials and is currently formulated in licensed vaccines that protect against shingles, malaria, and RSV. In aqueous environments, QS-21 is subject to hydrolytic degradation that is influenced by pH and temperature, resulting in the formation of a degradant known as QS-21 Hydrolyzed Product, QS-21 HP, which can occur during manufacturing and/or prolonged storage. The intact QS-21 and QS-21 HP induce distinct immune response profiles, making it critical to monitor the degradation of QS-21 in vaccine adjuvant formulations. To date, there has been a paucity of reliable assays for QS-21, its isomers, and degradant QS-21 HP in liposomal adjuvant formulations available that can be transferred seamlessly in quality control (QC) environments. Herein, we introduce a simple and QC-friendly liquid chromatography coupled to a charged aerosol detector (LC-CAD) enabled by stationary phase screening combined with in silico method development optimization. The method exploits 2.7&#xa0;&#x3bc;m fused-core phenyl hexyl particles, ensuring its versatility in standard and ultra-high pressure LC systems. This approach demonstrates a high correlation between predicted retention time (RT) and experimental outcomes with overall &#x2206;RT&#xa0;<&#xa0;4%. In addition, this assay shows great linearity, precision, specificity, and accuracy to advance process development characterization of new vaccine formulations.

Liposomes

Quantitative susceptibility mapping in neurodegenerative diseases: An umbrella review of iron-related biomarkers and mechanisms.

Pathological iron accumulation is a common pathophysiological hallmark across multiple neurodegenerative diseases (NDDs), motivating the need for accurate, non-invasive quantification methods. Quantitative susceptibility mapping (QSM) is an advanced magnetic resonance imaging (MRI) technique that enables in vivo measurement of tissue magnetic susceptibility (&#x3c7;), providing a sensitive proxy for iron content. This umbrella review systematically evaluates the diagnostic accuracy, clinical correlations, and distinct iron distribution patterns of QSM in major NDDs, such as Parkinson's disease (PD), Alzheimer's disease (AD), amyotrophic lateral sclerosis (ALS), and atypical Parkinsonism. We included 15 (13/15 were rated Low or Critically Low on AMSTAR 2) systematic reviews and meta-analyses (through July 15, 2026); however, the findings should be interpreted cautiously because of heterogeneity and the low methodological quality. A Corrected Covered Area (CCA) analysis demonstrated only slight overlap of primary studies across the included reviews (CCA&#xa0;=&#xa0;5.42%). Collectively, the evidence indicates that QSM provides comparable or higher diagnostic sensitivity and reliability than conventional R2* and SWI techniques, particularly for deep gray matter structures. The findings support significant iron overload in the substantia nigra, particularly in the pars compacta, as a robust biomarker for PD that correlates with motor severity and disease duration. Furthermore, regional iron profiling in the basal ganglia is critical for differential diagnosis; specifically, elevated &#x3c7; in the putamen and globus pallidus effectively distinguishes multiple system atrophy and progressive supranuclear palsy from idiopathic PD. Distinctively, AD and ALS exhibit specific &#x3c7; alterations in the thalamus, motor cortex, and hippocampus, reflecting divergent iron-related pathophysiological mechanisms, which correlate with cognitive impairment and upper motor neuron signs. Overall, QSM shows diagnostic promise and offers mechanistic insights into iron-related neurodegenerative processes.

Humans