Search PubMedSearch

SEARCH · Search PubMed

Results for “Pediatric radiology”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

199 recordsLinked to original sources

Comparison of Iodinated Contrast Doses Based on Total Body Weight and Lean Body Weight in Pediatric Patients: Impact on Image Quality and Contrast Exposure.

INTRODUCTION: Iodinated contrast dosing in pediatric computed tomography (CT) traditionally relies on total body weight (TBW), which may result in excessive contrast administration, particularly in patients with higher adiposity. Lean body weight (LBW)-based protocols have shown promise in adults but remain underexplored in children. Therefore, the aim of this study was to compare contrast volume requirements and hepatic enhancement quality among three dosing protocols: LBW-based, TBW-based, and the Control Group (CG), based on the institutional standard for pediatric abdominal CT. METHODS: This prospective study enrolled 66 patients (age 0-16 years) undergoing contrast-enhanced abdominal CT between September 2023 and August 2024. Patients were randomly assigned to receive iodinated contrast (iobitridol 350mg I/mL) dosed by: (1) LBW (0.63 g iodine/kg x LBW, calculated using Peters formula; n = 23), (2) TBW (0.46 g iodine/kg x TBW; n = 20), or (3) institutional control protocol (2 mL/kg x TBW, equivalent to 0.7 g iodine/kg; n = 23). Kruskal-Wallis, ANOVA, Two-way ANOVA, ANCOVA, Scheirer-Ray-Hare, and Cohen's Kappa tests with Likert scale were used. RESULTS: The LBW group received lower median contrast volumes (27 mL; IQR, 10-80 mL) compared to the TBW group (34.5 mL; IQR, 18-78 mL) and the CG group (40 mL; IQR, 13-80 mL), although the differences did not reach statistical significance (P > 0.05). Notably, this reduction did not compromise hepatic enhancement, which remained comparable to the CG (552 ± 139 HU; P = 0.107). CONCLUSION: Lean body weight may be a useful parameter for estimating contrast dose in pediatric abdominal CT, potentially reducing administered volumes without compromising diagnostic image quality. IMPLICATIONS FOR PRACTICE: These results provide early evidence that LBW-based dosing may support more individualized contrast administration in pediatric CT, potentially reducing exposure-related risks.

Humans

Factors associated with additional intervention requirement following ESWL in pediatric patients with urolithiasis.

OBJECTIVE: To identify predictors of additional intervention following extracorporeal shock wave lithotripsy (ESWL) in pediatric patients and to develop a clinically applicable predictive model. MATERIALS AND METHODS: This retrospective cohort study included 647 pediatric patients who underwent ESWL between 2015 and 2025. Demographic, clinical, and radiological variables were analyzed. Univariable and multivariable logistic regression analyses were performed to identify independent predictors of additional intervention. Model performance was evaluated using receiver operating characteristic curve analysis. RESULTS: Additional intervention was required in 65 patients (10.0%). On multivariable analysis, stone size 10-20 mm (OR: 3.04, p = 0.003), moderate (OR: 2.16, p = 0.049) and severe hydronephrosis (OR: 6.05, p < 0.001), and multiple stones (OR: 3.52, p = 0.030) were identified as independent risk factors. Increasing age (OR: 0.84, p = 0.026), history of urolithiasis (OR: 0.41, p = 0.006), and lower calyx location (OR: 0.14, p = 0.034) were associated with a reduced risk. The model demonstrated good discriminative performance (AUC: 0.794), with a sensitivity of 72% and specificity of 75%. Internal validation using bootstrap resampling demonstrated stable model performance, yielding a corrected AUC of 0.732. CONCLUSION: Stone burden, hydronephrosis severity, and stone multiplicity are key determinants of additional intervention after ESWL in pediatric patients. The proposed model shows good predictive performance and may support individualized risk stratification and clinical decision-making.

Humans

Ketamine Plus Midazolam versus Fentanyl Plus Midazolam for Sedation and Analgesia during Image-guided Procedures in Interventional Radiology: Randomized Clinical Trial.

Background Opioid-benzodiazepine regimens remain common for radiologist-administered procedural sedation despite respiratory and analgesic effectiveness concerns. Purpose To compare intraprocedural pain and patient-reported experience between ketamine/midazolam and fentanyl/midazolam during image-guided procedural sedation. Materials and Methods This randomized clinical trial was conducted at a single academic center between June 2025 and February 2026. Adults undergoing image-guided lung or bone biopsy or abscess drainage were randomized to fentanyl/midazolam or ketamine/midazolam administered by interventional radiologists. Procedures were performed using US, CT, CT fluoroscopy, or combined CT and US guidance. The primary outcome was maximum intraprocedural pain (0-10 on the Numeric Rating Scale). Secondary outcomes included sedation depth, physiologic parameters, oxygen desaturation, patient-reported experience assessed using a modified Heidelberg questionnaire, and complications. Results Among 264 randomized procedures (132 procedures per group) in 260 participants (median age, 68 years [IQR, 61-75 years]; 135 [52%] female), ketamine/midazolam resulted in lower maximum intraprocedural pain than fentanyl/midazolam (mean difference, -1.4 points [95% CI: -2.0, -0.8]; P < .001). Pain scores greater than 4 occurred less frequently with ketamine/midazolam (2.3% vs 17%; absolute difference, 14 percentage points [95% CI: 8, 21]; P < .001). Ketamine/midazolam was associated with higher nadir oxygen saturation (mean difference, +1.4% [95% CI: 0.6, 2.2]; P = .001) and fewer oxygen desaturation events below 90% (three [2.3%] vs 13 [9.8%]; absolute difference, 7.6 percentage points [95% CI: 1.9, 13.3]; P = .02). Ketamine/midazolam produced deeper sedation and higher intraprocedural systolic blood pressure. Hallucinations occurred more frequently with ketamine/midazolam (15 [11.4%] vs five [3.8%]; absolute difference, 7.6 percentage points [95% CI: 1.3, 13.9]; P = .03), though overall procedural comfort, reduced recall, and perceived adequacy of sedation were improved. Procedure-related and sedation-related complications did not differ between groups. Conclusion Radiologist-administered ketamine/midazolam during image-guided procedural sedation improved analgesia and patient-reported experience with fewer hypoxemic events and no increase in complications compared with fentanyl/midazolam. Clinical trial registration no. NCT07040163

Aged

Gelified ethanol for percutaneous sclerotherapy of bone lesions: a systematic review of clinical applications and outcomes.

PURPOSE: To systematically review the available evidence on the feasibility, safety, and clinical effectiveness of percutaneous sclerotherapy using radiopaque gelified ethanol (RGE, Discogel&#xae;) for bone lesions. METHODS: A systematic search of MEDLINE, Embase, Web of Science, and Cochrane CENTRAL was performed. Primary studies reporting clinical, technical, and safety outcomes following RGE sclerotherapy for bone lesions were included. Data on patient characteristics, lesion type, procedural details, and outcomes were extracted and synthesized descriptively. RESULTS: Six retrospective studies involving 55 patients (mean age 22.2&#x2009;&#xb1;&#x2009;20.4&#xa0;years; range 3-65; 26 females) with 56 lesions and 119 procedures were included (mean 2.16 procedures per patient). Aneurysmal bone cysts (80%) and aggressive vertebral hemangiomas (18%) were the main indications. Technical success was reported in 100% of procedures. Pain outcomes were available for 28 patients, with complete resolution in 64.3% (18/28), partial reduction in 32.1% (9/28), and persistence in 3.6% (1/28). Radiological follow-up (50 lesions) demonstrated complete response in 96% and partial response in 4%. No major adverse events were reported according to CIRSE (&#x2265;&#x2009;4) or CTCAE (&#x2265;&#x2009;4) criteria. One SIR grade 3 vertebral fracture occurred without confirmed causal association to RGE. Subsequent surgery was required in 3.6% of lesions. CONCLUSION: Although limited to small retrospective series, current evidence suggests that RGE sclerotherapy is a safe and effective minimally invasive option for selected benign bone lesions. Prospective comparative studies with longer follow-up are warranted.

Humans

Differences in Radiological Risk Perceptions Following Online and In-Person Workshops.

Nuclear energy is widely regarded as a critical part of the pathway toward a secure, low-carbon electricity grid, yet long-term management of used nuclear fuel remains a persistent challenge. Although technically viable options for interim and consolidated storage exist, public concern and community opposition - rooted in historical distrust and risk perception - continue to complicate siting decisions. In response, recent federal efforts have emphasized collaboration-based approaches and community engagement, though empirical evidence on the effectiveness of different engagement strategies remains limited. This study examines how the structure and delivery of community engagement influence changes in public attitudes toward hosting interim used nuclear fuel storage facilities. Using survey data from 13 educational workshops around the United States, we evaluate: (1) the inclusion of trust-building content prior to technical content, and (2) engagement format, comparing online and in-person workshops. Analyses focus on participant changes in perceptions of safety, risk, and support for hosting, using the Wilcoxon rank-sum test and other non-parametric hypothesis tests on surveys conducted before and after workshops. Results indicate that workshop participation is associated with some measurable attitude changes, with significant (p < 0.05) differences in response variability for some questions across workshop formats. In particular, when comparing nuclear energy to other clean energy sources, in-person workshop participants are substantially more likely to gain a more favorable opinion of nuclear energy than online participants. These findings contribute empirical evidence on how trust-building and delivery mode shape outcomes in public engagement on complex and contested energy policy issues such as storage of used nuclear fuel.

nuclear fuel cycle

Shielding performance and clinical applicability of lead-free materials in computed tomography.

Owing to the high radiation exposure associated with computed tomography (CT) examinations and the image quality degradation caused by conventional radiation shielding materials, this study evaluated the dose reduction performance and image quality maintenance potential of a newly developed lead-free composite shielding material. This material was composed of bismuth, tungsten, tungsten carbide, aluminium, and polyurethane. Phantom-based dose measurements demonstrated that the shielding material achieved dose reduction rates ranging from 17.6% to 37.6%, depending on tube voltage. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and changes in tube current-time product (mAs) under a scout-based automatic exposure control (AEC) protocol were analysed according to the presence or absence of the shielding material across regions. For the clinical evaluation, CT scans were performed on four patients. Furthermore, the images were reviewed to evaluate whether this material affected image quality. The shielding material exhibited radiation reduction levels comparable to those reported in previous studies. SNR and CNR analyses showed minor statistical variations in certain regions; however, most differences were not statistically significant, and even significant differences remained within a range that did not compromise diagnostic image quality. Under the scout-based AEC protocol, the use of the shielding material resulted in less than 1% variation in mAs values. No visually perceptible artefacts or clinically significant image quality degradation were observed. The proposed composite shielding material demonstrated the potential to mitigate some limitations of conventional shielding materials and showed preliminary clinical feasibility as an adjunctive strategy for radiation dose reduction in CT examinations.

Radiation Protection

A reanalysis of the Hitachi cohort study evaluating the effectiveness of low-dose CT screening for lung cancer.

The effectiveness of low-dose thoracic computed tomography (CT) screening for lung cancer for non-smokers or light smokers has been unclear. The results of the Hitachi cohort study performed by the conventional multivariable analysis suggested the reduction of lung cancer mortality by thoracic CT screening, but also revealed the lower all-cause mortality in the CT group, which indicated the existence of self-selection bias. Because the background of the subjects in the CT screening group and that in the X-ray screening group were very different, it is critical to adjust appropriately the confounding factors. In this brief report, we describe a re-evaluation of the results of the Hitachi Cohort Study performed by using more flexible methods, propensity score matching and inverse probability weighting.

epidemiology/public health

Effectiveness of kinesiologic tape in the management of postoperative trismus, discomfort, and edema in mandibular fractures: a randomized controlled trial.

OBJECTIVE: This study compared kinesiologic taping (KT) with conventional elastic adhesive bandaging in managing postoperative morbidity following open reduction and internal fixation. STUDY DESIGN: In this prospective, randomized controlled trial conducted at KLE Dr Prabhakar Kore Hospital, 26 patients with unilateral mandibular fractures were allocated into two groups: Group 1 received an elastic adhesive bandage (n = 13) and Group 2 used KT (n = 13). Pain (Visual Analog Scale), facial swelling (standardized linear measurements), and maximum interincisal distance were recorded at baseline and on postoperative Days 2 and 5. Data were analyzed using repeated measures ANOVA and independent t tests (p < .05). RESULTS: The KT group showed significantly lower pain scores and reduced facial edema at Days 2 and 5 compared with controls (P < .05). Trismus improved in both groups without significant intergroup differences. No adverse effects were observed. CONCLUSIONS: KT is a safe and effective adjunct for reducing early postoperative pain and edema after mandibular fracture fixation.

Humans

Impact of Commercial Artificial Intelligence on Radiologist Reading Time for Pulmonary Nodule Evaluation at Chest CT.

Background Chest CT is a primary method for identifying pulmonary nodules, yet interpreting scans remains time-intensive and demanding. Currently, artificial intelligence (AI) is expected to reduce reading times, but the effect of AI on reporting times in this setting is unknown. Purpose To evaluate the impact of a commercial AI software on radiologists' reading time for pulmonary nodule assessment on chest CT scans within a real-world clinical setting. Materials and Methods This retrospective study included patients who underwent chest CT examinations at a tertiary medical center between September 2021 and May 2024. The study period was divided into pre- and post-AI phases. The primary outcome was radiology reporting time. The association between AI implementation and reporting time was evaluated using a multivariable parametric Weibull shared frailty survival model adjusted for reader function, examination type, patient location, and requesting specialty, with clustering at the radiologist level. Interaction analyses assessed heterogeneity across prespecified subgroups. An exploratory extrapolation estimated projected workforce and financial impact. Results This study included 19&#x2009;433 patients (mean age, 62 years &#xb1; 14.2 [SD]; 21&#x2009;814 men; 39&#x2009;323 chest CT examinations, 19&#x2009;190 pre-AI, and 20&#x2009;133 post-AI). AI implementation was associated with faster report completion (adjusted hazard ratio, 1.17; 95% CI: 1.14, 1.21; P < .001). The adjusted median reporting time decreased from 21.3 minutes pre-AI to 18.2 minutes post-AI (14.6% reduction; P < .001). Heterogeneity was observed across reader function (P < .001), examination type (P = .048), and requesting specialty (P = .03). The largest relative reductions were observed for CT thorax electrocardiogram-gated examinations (-41.1%; P < .001) and thoracic radiologists (-25.0%; P < .001), whereas emergency department examinations showed increased median reporting time (7.1%; P < .001). At institutional scan volumes (approximately 20&#x2009;000-22&#x2009;000 chest CT examinations annually), exploratory modeling suggested an approximate reduction of 0.5 full-time equivalent radiologist workload. Conclusion Implementation of commercial AI-assisted pulmonary nodule assessment on chest CT scans reduced radiologist reporting time in a real-world clinical setting. &#xa9; The Author(s) 2026. Published by the Radiological Society of North America under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Iwasawa in this issue.

Humans

The role of particle therapy in the treatment of locally recurrent rectal cancer: a systematic review.

BACKGROUND: Colorectal cancer is a common malignancy. Advancements in multimodality treatment have improved outcomes. About 2-10% of patients will have a local recurrence even after optimal treatment. Salvage surgical treatment is the treatment of choice, however, in posterior and lateral recurrences, surgery is linked to a high rate of treatment-related morbidity. Some recurrences remain unresectable even after neoadjuvant treatment. MATERIALS AND METHODS: A systematic literature review was performed to search for studies on curative-intent radiation therapy (RT) with photons, stereotactic body radiation therapy (SBRT) and particle beam therapy. The aim of the literature search was to define the role of particle therapy in the treatment of patients with unresectable or inoperable local recurrences of rectal cancer where neoadjuvant treatment is unlikely to result in downstaging, leaving patients with RT as the only curative treatment option. RESULTS: 32 studies which fulfil the criteria were identified. In general, SBRT and particle beam therapy permitted the application of significantly higher doses to the target without a concomitant increase in treatment-related toxicities. CONCLUSIONS: For unresectable and inoperable locally recurrent rectal cancer ablative radiotherapy techniques such as SBRT and particle beam therapy offer a curative treatment approach as an alternative to surgery. SBRT can be offered for small local and nodal recurrences, while particle beam therapy can be offered for larger recurrences and complex shapes spanning several anatomical compartments as well. Further research is needed to stratify patients according to their need and eligibility for the different possible modalities of curative-intent RT.

Humans

Neighborhood Deprivation and Screening Mammography Utilization: A Retrospective Cross-Sectional Study.

RATIONALE AND OBJECTIVES: Access to screening mammography reduces breast cancer mortality disparities. The Area Deprivation Index (ADI) is a validated measure of neighborhood socioeconomic disadvantage linked to adverse health outcomes. There is limited data evaluating mammography utilization among patients residing in areas of higher deprivation. This study evaluated the association between ADI and screening mammography utilization within an accountable care organization (ACO) affiliated with a multicenter academic medical center in the Upper Midwest. METHODS: This retrospective cross-sectional study included women aged 40-85 years attributed to the ACO in 2022, based on Wisconsin Collaborative for Healthcare Quality criteria. The primary outcome was receipt of screening mammography within two years. The primary exposure was ADI, analyzed by decile (ordinal) and as low (deciles 1-5) versus high (deciles 6-10) deprivation. The logistic regression models evaluated associations between ADI and screening, unadjusted and adjusted for age, race, ethnicity, and preferred language. RESULTS: Among 7463 participants with geographic data, 74.4% completed screening. Screening rates were 75.7% in low-deprivation areas versus 66.2% in high-deprivation areas. Increasing ADI decile was associated with reduced screening in unadjusted (OR 0.891, 95% CI 0.87-0.91, p<0.001) and adjusted analyses (OR 0.897, 95% CI 0.88-0.92, p<0.001). Black participants (OR 0.444, p<0.001) and individuals preferring non-English languages (OR 0.333, p<0.001) had lower screening odds after adjustment. CONCLUSION: Higher neighborhood deprivation is independently associated with lower screening mammography utilization. Targeted, equity-focused interventions addressing neighborhood, racial, and language-related barriers are needed to reduce screening disparities.

Area deprivation Index

Ultrasound protocols used to detect vascular gas emboli in divers: a systematic review.

INTRODUCTION: Venous gas emboli (VGE) detected via ultrasound can be used as a surrogate marker for decompression stress. While Doppler ultrasound is the historical gold standard, two-dimensional (2D) ultrasonography offers advantages for on-site monitoring, including a wider field of view and reduced dependence on noise-free environments. This systematic review evaluates 2D ultrasonography protocols used in decompression research since the 2015 International Meeting on Ultrasound for Diving Research, identifying methodological similarities, differences, and adherence to consensus recommendations. METHODS: A search of PubMed and Scopus identified studies using 2D ultrasound to detect VGE in divers. Inclusion criteria were: (1) use of 2D ultrasound, (2) detection of VGE or monitoring of decompression stress, (3) inclusion of a diver cohort, and (4) publication after 2015. Data extraction focused on VGE scoring systems, ultrasound hardware, measurement protocols, and operator experience. Risk of bias was assessed using ROBINS-I-V2, and compliance with the 2015 consensus recommendations was evaluated. RESULTS: Twenty studies were included. The Eftedal-Brubakk scale was most commonly used (n = 15), with cardiac ultrasound as the primary imaging modality; one study assessed a peripheral vessel. Common shortcomings included post-dive measurements lasting less than two hours, underreporting of operator experience and hardware specifications, limited individual-level data, and inappropriate use of parametric statistics for ordinal bubble grade data. No study fully complied with all consensus recommendations. CONCLUSIONS: This review demonstrates that, although two-dimensional ultrasound is widely used for post-dive VGE assessment, methodological heterogeneity with multiple shortcomings remain. Furthermore, nearly all studies restricted imaging to the heart, thus leaving peripheral vessel assessment largely unexplored.

Embolism, Air

Photon-counting detector computed tomography (PCD-CT) in multiple myeloma: a systematic review and trial sequential meta-analysis on image quality and radiation dose.

OBJECTIVES: To systematically review and perform a meta-analysis comparing the effects of PCD-CT versus EID-CT on image quality (sharpness) and radiation dose (CTDIvol) in patients with bone lesions due to multiple myeloma&#xa0;(MM). METHODS: A comprehensive search of PubMed, Embase, Scopus, and Cochrane Central was conducted from inception to October 2025. Studies comparing PCD-CT and EID-CT in MM patients were included. Methodological quality was assessed using ROBINS-I, and the certainty of evidence was assessed using GRADE. RESULTS: A total of 41 studies were identified that matched our search criteria. After duplicate removal and screening, five studies (n = 170 patients) were included in the systematic review, with four contributing to the meta-analysis. PCD-CT showed a significant pooled mean difference in image sharpness (mean difference, + 0.99 points; 95% CI, 0.62-1.37; p < 0.001). PCD-CT also demonstrated a reduction in radiation dose (mean difference, -4.95 milligrays; 95% CI, -8.39 to -1.50; p = 0.005). Trial sequential analysis (TSA) confirmed stability of pooled estimates, with conclusive evidence for image sharpness improvement, and suggestive yet incomplete evidence for radiation dose reduction. CONCLUSION: Compared to EID-CT in MM, PCD-CT significantly improves subjective image sharpness as supported by trial sequential analysis. Conventional meta-analysis suggested a reduction in radiation dose with PCD-CT; however, trial sequential analysis indicated that the cumulative evidence remains inconclusive. Further large-scale studies are suggested to confirm the magnitude of the radiation dose reduction benefit.

Humans

Robust optimisation for photon radiotherapy: A scoping review of models, paradigms, and reporting.

BACKGROUND AND PURPOSE: Robust optimisation offers an alternative to conventional margin-based photon radiotherapy planning by explicitly modelling uncertainty, but practice is variable and not standardised. MATERIALS AND METHODS: A scoping review was conducted to map robust optimisation for photon external beam radiotherapy. Electronic searches of Scopus, PubMed and Google Scholar (2000-2025, English language) identified planning studies that incorporated modelled uncertainties into the optimisation process and reported at least one robustness-related outcome. Data were charted on clinical context, uncertainty models, optimisation paradigms, robustness metrics and evidence for clinical implementation. RESULTS: Seventy-one studies were included. Most investigated prostate, breast or lung cancer and used intensity-modulated radiotherapy or volumetric-modulated arc therapy in commercial or research treatment planning systems. Scenario-based worst-case (minimax) optimisation was the dominant paradigm in clinically oriented work, while chance-constrained, conditional value at-risk, distributionally robust and adaptive formulations were confined to small methodological series. Uncertainty modelling focused mainly on rigid set-up error; fewer studies incorporated respiratory motion, inter-fraction anatomical change, dose-calculation uncertainty or biological variation. Robustness was evaluated with diverse scenario-based dose-volume metrics, probabilistic coverage measures, composite robustness indices and, less often, biological endpoints. Direct clinical implementation reports were scarce. CONCLUSION: Robust photon planning is technically feasible and generally maintains or improves target coverage and organ sparing compared with margin-based planning. However, heterogeneity in uncertainty models, optimisation configuration and robustness reporting limits comparison and synthesis. Pragmatic minimum standards are proposed to support future consensus and wider clinical adoption.

Humans

Discrepancies in CPAK classification between CT and long-leg radiography: a systematic review and meta-analysis.

OBJECTIVE: To determine whether substantial differences in coronal plane alignment of the knee phenotype distribution, as well as systematic angular measurement discrepancies, exist between CT and long-leg radiography. MATERIALS AND METHODS: From February 2021 to April 2025, we searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials for studies comparing CT- and long-leg radiography-derived coronal plane alignment classifications of the knee in patients with osteoarthritis. The primary outcome was distribution of coronal plane alignment phenotypes. Secondary outcomes included differences in medial proximal tibial angle, lateral distal femoral angle, arithmetic hip-knee-ankle angle, and joint line obliquity. RESULTS: Four studies (1,134 knees) were included. Compared with long-leg radiography-derived classification, CT-derived classification increased type I phenotypes (risk difference: 0.10; 95% confidence interval: 0.01-0.20; P&#x2009;=&#x2009;0.040) and decreased type III (risk difference: -0.04; 95% confidence interval: -0.07 to -0.01; P&#x2009;=&#x2009;0.020) and type V phenotypes (risk difference: -0.04; 95% confidence interval: -0.07 to -0.01; P&#x2009;=&#x2009;0.004). CT yielded significantly lower medial proximal tibial angle (weighted mean difference:&#x2009;-&#x2009;1.18&#xb0;; P&#x2009;<&#x2009;0.001), arithmetic hip-knee-ankle angle (weighted mean difference:&#x2009;-&#x2009;0.95&#xb0;; P&#x2009;<&#x2009;0.001), and joint line obliquity (weighted mean difference:&#x2009;-&#x2009;1.40&#xb0;; P&#x2009;<&#x2009;0.001) than long-leg radiography. Heterogeneity was high for type I phenotype (I2&#x2009;=&#x2009;81%), lateral distal femoral angle (I2&#x2009;=&#x2009;70%), and joint line obliquity (I2&#x2009;=&#x2009;69%). CONCLUSION: Discrepancies between CT-based software-generated and long-leg radiography-derived measurements substantially affect coronal plane alignment classification and angular parameters. Surgeons should consider these modality-specific variations and employ compensatory verification strategies to ensure optimal alignment.

Humans

Complexity in disguise: a systematic review of fractal analysis in psychiatric neuroimaging.

OBJECTIVES: Psychiatric diagnosis and fractal studies are complex processes that extend beyond clinical evaluation and require careful methodological considerations in neuroimaging. Over the years, fractals have helped reduce these complexities in research, but they still cannot grant clinical diagnoses. Thus, the main objective was a systematic review exploring the potential applications of fractal analysis in characterizing psychiatric conditions through neuroimaging techniques-including both functional and structural MRI. MATERIALS AND METHODS: A systematic literature review was conducted on PubMed, identifying thirty-nine original studies that met the inclusion criteria. Areas showing statistical significance (p&#x2009;<&#x2009;0.05) were reported. These studies were categorized according to DSM-V classification and examined for the description of psychiatric conditions through the fractal analysis. RESULTS: The review primarily focuses on young adults with psychiatric conditions compared to control groups. Schizophrenia and Autism Spectrum Disorder are major areas of investigation, and fractal dimension (FD) is the primary analysis method used to reflect brain patterns. Studies that calculated whole-brain FD may have underestimated local abnormalities due to the inclusion of a high percentage of tissue, potentially resulting in overlooked findings. Notably, abnormalities in the frontal cortex represent a common neurobiological feature across several psychiatric conditions. CONCLUSIONS: The findings from this systematic review shed light on the use of fractal analysis to quantify complex brain patterns in both psychiatric patients and healthy individuals. However, it is essential to recognize the need for further research to elucidate a fractal analysis protocol that allows for optimal extraction of psychiatric insights. KEY POINTS: Question Fractal analysis applied to structural and functional MRI help characterize brain alterations across psychiatric conditions. Findings This review shows consistent fractal patterns across multiple psychiatric disorders, especially in frontal regions. Despite heterogeneous methodologies, results highlight shared structural and functional abnormalities. Clinical relevance Fractal analysis may offer complementary characterization of subtle brain organization across psychiatric disorders. Its potential clinical utility-such as improving diagnostic characterization, earlier detection, among others-remains limited by the current absence of a standardized protocol.

Humans

Exploring the Diagnostic Utility of Ferumoxytol for Brachial Plexus MR Neurography.

Background Ferumoxytol has been described as an alternative contrast agent for vascular suppression in MR neurography (MRN), but its diagnostic utility in patients has yet to be evaluated. Purpose To evaluate the impact of ferumoxytol on vascular suppression, nerve conspicuity, and evaluation of nerve abnormalities at three-dimensional (3D) brachial plexus MRN, compared with noncontrast and gadolinium-enhanced MRN, in participants with suspected Parsonage-Turner syndrome (PTS) or thoracic outlet syndrome (TOS). Materials and Methods This prospective study included participants who underwent 3D MRN with and/or without gadolinium chelate for clinical suspicion of PTS or TOS and subsequently underwent 3D MRN with ferumoxytol (within 3 months of the clinical examination). Two musculoskeletal radiologists qualitatively evaluated 3D short-tau inversion-recovery fast spin-echo scans for the degree of vascular suppression, nerve conspicuity, and presence of nerve abnormalities. Wilcoxon signed-rank or McNemar tests were used for comparing noncontrast and gadolinium-enhanced scans with ferumoxytol-enhanced scans. Results This study included 18 participants (mean age, 42 years &#xb1; 15.2 [SD]; 10 men). Ferumoxytol-enhanced scans demonstrated improved vascular suppression compared with both noncontrast scans (both raters, P < .001) and gadolinium-enhanced scans (both P = .04). For rater 2, ferumoxytol-enhanced acquisitions demonstrated improved conspicuity of several nerve segments relative to the noncontrast scan, including segments of the suprascapular (P = .01), axillary (P = .02), and long thoracic nerves (P = .004). The distribution of scores for these nerve segments for rater 1 also favored ferumoxytol-enhanced versus noncontrast scans, but the differences were not statistically significant (all P &#x2265; .06). There was no evidence of a difference in nerve conspicuity between ferumoxytol-enhanced and gadolinium-enhanced scans (P &#x2265; .17 for all nerve segments) and also no evidence of discrepancies in abnormal nerve findings between the acquisitions (all P &#x2265; .48). Conclusion Ferumoxytol improved vascular suppression compared with noncontrast and gadolinium-enhanced 3D short-tau inversion-recovery fast spin-echo sequences in brachial plexus MRN, enhancing the conspicuity of several nerve branches versus noncontrast scans, with similar detection of abnormal nerve findings. &#xa9; RSNA, 2026 Supplemental material is available for this article.

Humans

Performance of Photon-counting CT for Assessing Pretreatment Breast Cancer: Comparison with Mammography, MRI, and 18F-FDG PET/CT.

Background Photon-counting CT (PCCT) offers improved spatial resolution, contrast to noise ratio, and dose efficiency, but its clinical utility remains incompletely defined for breast cancer. Purpose To evaluate the feasibility of PCCT for pretreatment breast cancer assessment through comparisons with MRI, full-field digital mammography (FFDM), and fluorine 18 (18F) fluorodeoxyglucose (FDG) PET/CT. Materials and Methods In this prospective study (March-May 2025), female participants with breast lesions categorized as Breast Imaging Reporting and Data System 4C or higher at US or FFDM underwent breast MRI and multiphasic contrast-enhanced PCCT. 18F-FDG PET/CT was performed in a subset with locally advanced disease. Four radiologists independently evaluated lesion morphologic characteristics, additional findings, and clinical TNM stage. Agreement was analyzed using intraclass correlation coefficients (ICCs) and &#x3ba; statistics. The diagnostic performance for additional lesions and nodal metastasis was compared with the reference standard (pathologic examination). Results Among 126 participants (mean age, 58.1 years &#xb1; 12.3 [SD]), interreader agreement across PCCT, MRI, and FFDM was good to excellent. PCCT agreed with MRI for lesion characterization (&#x3ba; = 0.57-0.96) and clinical T categorization (&#x3ba; = 0.86-0.88), with highest agreement with pathologic size (ICC, 0.70-0.81). For 46 pathologically confirmed additional lesions, PCCT was more sensitive than FFDM (difference, 44% [95% CI: 19, 66]) and similar to MRI (difference, 7% [95% CI: -5, 21]). Additionally, 44% (95% CI: 27, 52) of microcalcifications were missed at PCCT versus FFDM. For pathologically confirmed nodal metastasis, PCCT was more sensitive (difference, 10% [95% CI: 1, 20]) and accurate (difference, 6% [95% CI: 1, 11]) than MRI. For clinical N category, PCCT agreed with PET/CT (&#x3ba; = 0.82 [95% CI: 0.62, 0.96]; n = 19). Two distant metastases identified at PCCT were consistent with 18F-FDG PET/CT and pathologic findings. Conclusion PCCT demonstrated similar performance to MRI for lesion characterization and detection of additional lesions, with better performance for nodal metastasis evaluation; however, detection of microcalcifications was limited. &#xa9; RSNA, 2026 Supplemental material is available for this article.

Humans