Search PubMedSearch

SEARCH · Search PubMed

Results for “Low-dose CT”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

777 recordsLinked to original sources

A reanalysis of the Hitachi cohort study evaluating the effectiveness of low-dose CT screening for lung cancer.

The effectiveness of low-dose thoracic computed tomography (CT) screening for lung cancer for non-smokers or light smokers has been unclear. The results of the Hitachi cohort study performed by the conventional multivariable analysis suggested the reduction of lung cancer mortality by thoracic CT screening, but also revealed the lower all-cause mortality in the CT group, which indicated the existence of self-selection bias. Because the background of the subjects in the CT screening group and that in the X-ray screening group were very different, it is critical to adjust appropriately the confounding factors. In this brief report, we describe a re-evaluation of the results of the Hitachi Cohort Study performed by using more flexible methods, propensity score matching and inverse probability weighting.

epidemiology/public health

Stage shift, histological differentiation, and survival patterns of lung squamous cell carcinoma versus adenocarcinoma in low-dose CT screening.

BACKGROUND: Whether LDCT-associated stage shift translates into similar survival patterns across lung cancer histologies remains uncertain. We compared stage shift, histological differentiation, tumor characteristics, and survival between lung squamous cell carcinoma (LUSC) and adenocarcinoma (LUAD) in the National Lung Screening Trial. METHODS: Among participants diagnosed with LUSC or LUAD, stage distribution and histological differentiation were compared between LDCT and chest X-ray (CXR) arms. Survival among diagnosed cases was measured from randomization. Multivariable models tested screening arm-by-histology interactions. Screen-detected LDCT tumors were compared by histology. RESULTS: During 6.5 years of median follow-up, 498 LUAD and 249 LUSC cases were diagnosed in the LDCT arm, and 374 and 212, respectively, were diagnosed in the CXR arm. LDCT was associated with higher odds of stage I disease for LUAD (adjusted odds ratio [aOR], 2.48; 95% CI 1.88-3.28) and LUSC (aOR, 1.71; 95% CI 1.17-2.48), without significant interaction (P&#x202f;=&#x202f;0.116). LDCT was associated with lower hazard of lung cancer-specific death among diagnosed LUAD cases (adjusted hazard ratio [aHR], 0.54; 95% CI 0.43-0.66), but not among diagnosed LUSC cases (aHR, 1.04; 95% CI 0.78-1.39; P for interaction<0.001). LUSC had lower screening sensitivity, more frequent detection in annual screening rounds, greater prediagnostic tumor size increase, and fewer well-differentiated stage I tumors than LUAD. CONCLUSION: LDCT was associated with stage shift for both subtypes, but favorable survival patterns among diagnosed cases were mainly observed for LUAD. Lower screening sensitivity, greater prediagnostic tumor size increase, and poorer histological differentiation may help explain why stage shift did not translate into similar survival patterns for LUSC. TRIAL REGISTRATION: ClinicalTrials.gov, NCT00047385.

Humans

Photon-counting detector computed tomography (PCD-CT) in multiple myeloma: a systematic review and trial sequential meta-analysis on image quality and radiation dose.

OBJECTIVES: To systematically review and perform a meta-analysis comparing the effects of PCD-CT versus EID-CT on image quality (sharpness) and radiation dose (CTDIvol) in patients with bone lesions due to multiple myeloma&#xa0;(MM). METHODS: A comprehensive search of PubMed, Embase, Scopus, and Cochrane Central was conducted from inception to October 2025. Studies comparing PCD-CT and EID-CT in MM patients were included. Methodological quality was assessed using ROBINS-I, and the certainty of evidence was assessed using GRADE. RESULTS: A total of 41 studies were identified that matched our search criteria. After duplicate removal and screening, five studies (n = 170 patients) were included in the systematic review, with four contributing to the meta-analysis. PCD-CT showed a significant pooled mean difference in image sharpness (mean difference, + 0.99 points; 95% CI, 0.62-1.37; p < 0.001). PCD-CT also demonstrated a reduction in radiation dose (mean difference, -4.95 milligrays; 95% CI, -8.39 to -1.50; p = 0.005). Trial sequential analysis (TSA) confirmed stability of pooled estimates, with conclusive evidence for image sharpness improvement, and suggestive yet incomplete evidence for radiation dose reduction. CONCLUSION: Compared to EID-CT in MM, PCD-CT significantly improves subjective image sharpness as supported by trial sequential analysis. Conventional meta-analysis suggested a reduction in radiation dose with PCD-CT; however, trial sequential analysis indicated that the cumulative evidence remains inconclusive. Further large-scale studies are suggested to confirm the magnitude of the radiation dose reduction benefit.

Humans

Comparison of Iodinated Contrast Doses Based on Total Body Weight and Lean Body Weight in Pediatric Patients: Impact on Image Quality and Contrast Exposure.

INTRODUCTION: Iodinated contrast dosing in pediatric computed tomography (CT) traditionally relies on total body weight (TBW), which may result in excessive contrast administration, particularly in patients with higher adiposity. Lean body weight (LBW)-based protocols have shown promise in adults but remain underexplored in children. Therefore, the aim of this study was to compare contrast volume requirements and hepatic enhancement quality among three dosing protocols: LBW-based, TBW-based, and the Control Group (CG), based on the institutional standard for pediatric abdominal CT. METHODS: This prospective study enrolled 66 patients (age 0-16 years) undergoing contrast-enhanced abdominal CT between September 2023 and August 2024. Patients were randomly assigned to receive iodinated contrast (iobitridol 350mg I/mL) dosed by: (1) LBW (0.63 g iodine/kg x LBW, calculated using Peters formula; n = 23), (2) TBW (0.46 g iodine/kg x TBW; n = 20), or (3) institutional control protocol (2 mL/kg x TBW, equivalent to 0.7 g iodine/kg; n = 23). Kruskal-Wallis, ANOVA, Two-way ANOVA, ANCOVA, Scheirer-Ray-Hare, and Cohen's Kappa tests with Likert scale were used. RESULTS: The LBW group received lower median contrast volumes (27 mL; IQR, 10-80 mL) compared to the TBW group (34.5 mL; IQR, 18-78 mL) and the CG group (40 mL; IQR, 13-80 mL), although the differences did not reach statistical significance (P > 0.05). Notably, this reduction did not compromise hepatic enhancement, which remained comparable to the CG (552 &#xb1; 139 HU; P = 0.107). CONCLUSION: Lean body weight may be a useful parameter for estimating contrast dose in pediatric abdominal CT, potentially reducing administered volumes without compromising diagnostic image quality. IMPLICATIONS FOR PRACTICE: These results provide early evidence that LBW-based dosing may support more individualized contrast administration in pediatric CT, potentially reducing exposure-related risks.

Humans

Shielding performance and clinical applicability of lead-free materials in computed tomography.

Owing to the high radiation exposure associated with computed tomography (CT) examinations and the image quality degradation caused by conventional radiation shielding materials, this study evaluated the dose reduction performance and image quality maintenance potential of a newly developed lead-free composite shielding material. This material was composed of bismuth, tungsten, tungsten carbide, aluminium, and polyurethane. Phantom-based dose measurements demonstrated that the shielding material achieved dose reduction rates ranging from 17.6% to 37.6%, depending on tube voltage. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and changes in tube current-time product (mAs) under a scout-based automatic exposure control (AEC) protocol were analysed according to the presence or absence of the shielding material across regions. For the clinical evaluation, CT scans were performed on four patients. Furthermore, the images were reviewed to evaluate whether this material affected image quality. The shielding material exhibited radiation reduction levels comparable to those reported in previous studies. SNR and CNR analyses showed minor statistical variations in certain regions; however, most differences were not statistically significant, and even significant differences remained within a range that did not compromise diagnostic image quality. Under the scout-based AEC protocol, the use of the shielding material resulted in less than 1% variation in mAs values. No visually perceptible artefacts or clinically significant image quality degradation were observed. The proposed composite shielding material demonstrated the potential to mitigate some limitations of conventional shielding materials and showed preliminary clinical feasibility as an adjunctive strategy for radiation dose reduction in CT examinations.

Radiation Protection

Performance of Photon-counting CT for Assessing Pretreatment Breast Cancer: Comparison with Mammography, MRI, and 18F-FDG PET/CT.

Background Photon-counting CT (PCCT) offers improved spatial resolution, contrast to noise ratio, and dose efficiency, but its clinical utility remains incompletely defined for breast cancer. Purpose To evaluate the feasibility of PCCT for pretreatment breast cancer assessment through comparisons with MRI, full-field digital mammography (FFDM), and fluorine 18 (18F) fluorodeoxyglucose (FDG) PET/CT. Materials and Methods In this prospective study (March-May 2025), female participants with breast lesions categorized as Breast Imaging Reporting and Data System 4C or higher at US or FFDM underwent breast MRI and multiphasic contrast-enhanced PCCT. 18F-FDG PET/CT was performed in a subset with locally advanced disease. Four radiologists independently evaluated lesion morphologic characteristics, additional findings, and clinical TNM stage. Agreement was analyzed using intraclass correlation coefficients (ICCs) and &#x3ba; statistics. The diagnostic performance for additional lesions and nodal metastasis was compared with the reference standard (pathologic examination). Results Among 126 participants (mean age, 58.1 years &#xb1; 12.3 [SD]), interreader agreement across PCCT, MRI, and FFDM was good to excellent. PCCT agreed with MRI for lesion characterization (&#x3ba; = 0.57-0.96) and clinical T categorization (&#x3ba; = 0.86-0.88), with highest agreement with pathologic size (ICC, 0.70-0.81). For 46 pathologically confirmed additional lesions, PCCT was more sensitive than FFDM (difference, 44% [95% CI: 19, 66]) and similar to MRI (difference, 7% [95% CI: -5, 21]). Additionally, 44% (95% CI: 27, 52) of microcalcifications were missed at PCCT versus FFDM. For pathologically confirmed nodal metastasis, PCCT was more sensitive (difference, 10% [95% CI: 1, 20]) and accurate (difference, 6% [95% CI: 1, 11]) than MRI. For clinical N category, PCCT agreed with PET/CT (&#x3ba; = 0.82 [95% CI: 0.62, 0.96]; n = 19). Two distant metastases identified at PCCT were consistent with 18F-FDG PET/CT and pathologic findings. Conclusion PCCT demonstrated similar performance to MRI for lesion characterization and detection of additional lesions, with better performance for nodal metastasis evaluation; however, detection of microcalcifications was limited. &#xa9; RSNA, 2026 Supplemental material is available for this article.

Humans

Resistance versus concurrent training with three assigned protein targets in middle-aged and older women: a randomized 2 &#xd7; 3 factorial trial.

BACKGROUND: Evidence is limited regarding whether assigned protein targets modify responses to resistance training (RT) alone or to the same RT program plus cycling (concurrent training [CT]) in middle-aged and older women. This randomized 2&#x2009;&#xd7;&#x2009;3 factorial trial examined bioelectrical impedance analysis (BIA)-derived skeletal muscle mass (SMM; primary outcome), other body composition outcomes, muscular and functional performance, and cycle-derived estimated VO&#x2082;max. METHODS: In this randomized 2&#x2009;&#xd7;&#x2009;3 factorial trial, 108 women aged 40-77 years were assigned to 12 weeks of supervised RT or CT (identical RT followed by cycling) and protein targets of 0.8, 1.6, or 2.2 g&#xb7;kg-1&#xb7;d-1. Baseline-adjusted ANCOVA tested training&#x2009;&#xd7;&#x2009;protein interactions and marginal training and protein effects. Complete-case analyses included 83 participants. RESULTS: For SMM, no training-condition&#x2009;&#xd7;&#x2009;protein-target interaction (p&#x2009;=&#x2009;0.856), marginal protein-target effect (p&#x2009;=&#x2009;0.726), or marginal training-condition effect (p&#x2009;=&#x2009;0.273) was detected. CT had a lower baseline-adjusted week-12 BFP than RT (adjusted difference, -2.04 percentage points; 95% CI, -2.94 to -1.14; p&#x2009;<&#x2009;0.001). RT had a higher baseline-adjusted week-12 leg-press estimated 1-RM than CT (CT - RT: -6.68 kg; 95% CI, -8.32 to -5.04; p&#x2009;<&#x2009;0.001), whereas CT had a higher baseline-adjusted week-12 cycle-derived estimated VO&#x2082;max (adjusted difference, 4.53 mL&#xb7;kg-1&#xb7;min-1; 95% CI, 3.80 to 5.25; p&#x2009;<&#x2009;0.001). No detectable marginal protein-target effects or training-condition&#x2009;&#xd7;&#x2009;protein-target interactions were observed for the key secondary outcomes. CONCLUSIONS: No detectable differences in SMM or key secondary outcomes were attributable to assigned protein target. Compared with RT, CT favored estimated aerobic fitness and BFP, whereas RT favored leg-press strength. Because CT included additional cycling and greater exercise exposure, these differences cannot be attributed solely to training modality. Null protein findings do not establish equivalence among doses.

Humans

Effects of 12 weeks of resistance and concurrent training with graded protein intakes on lipid profile, kidney and liver biomarkers in middle-aged to older women.

PURPOSE: To examine secondary lipid, kidney-related, and liver-enzyme responses to three protein intakes during resistance training (RT) alone or the same RT plus cycling (CT) in middle-aged to older women. METHODS: In this randomized 2&#xd7;3 factorial trial, 108 women aged 40-77 years were assigned to RT or CT and 0.8, 1.6, or 2.2 g kg-1 d-1 protein for 12 weeks. This complete-case secondary analysis included 83 participants. Linear mixed-effects models tested Time &#xd7; Training, Time &#xd7; Protein, and Time &#xd7; Training &#xd7; Protein effects, with false-discovery-rate-adjusted omnibus tests and Holm-adjusted contrasts. RESULTS: Triglycerides, total cholesterol, LDL-C, and apolipoprotein B decreased and HDL-C increased in all conditions. Lipid changes differed by protein condition, and several were more favorable with CT; however, CT comprised RT plus additional cycling and greater exercise exposure. Urea, blood urea nitrogen, creatinine, the blood urea nitrogen-to-creatinine ratio, and cystatin C increased, whereas three eGFR estimates decreased. Responses differed mainly between 0.8 and the two higher protein conditions, with little evidence of differences between 1.6 and 2.2 g kg-1 d-1. ALT, AST, and GGT differed by protein condition; AST and GGT also showed training-dependent responses. CONCLUSIONS: The dietary and exercise interventions modified lipid and clinical-chemistry responses. Because energy and food composition were not fully matched and CT added cycling to RT, the findings do not isolate protein dose or exercise modality. Changes in eGFR estimates and liver enzymes do not establish organ injury or long-term safety.

Humans

Developing low-carbon metered-dose inhalers: effects of propellant HFA-152a on mucociliary clearance and bronchoconstriction in two Phase 1 randomised trials.

BACKGROUND: To reduce the impact of respiratory care on climate change, metered-dose inhalers (MDIs) are being reformulated with low-global warming potential (GWP) propellants. Next-generation propellant hydrofluoroalkane (HFA)-152a has >90% lower GWP than HFA-134a. As part of the safety evaluation for HFA-152a, mucociliary clearance (MCC), bronchoconstriction and safety were compared with HFA-134a. METHODS: Two Phase 1, randomised, two-way crossover studies (NCT06506266/NCT06702462) were conducted. MCC study: healthy participants inhaled HFA-152a and HFA-134a in two 7-day sequences. MCC was quantified as area under radiolabelled particle retention time curve over 4&#x202f;h (AUC0-4h) after nebulised 99mTc sulphur colloid, following each propellant. Bronchoconstriction study: patients with mild asthma inhaled single doses of HFA-152a and HFA-134a. Non-inferiority of HFA-152a versus HFA-134a was defined as percent change in FEV1 (litres), 15&#x202f;min post dose (95% confidence intervals [CI]: lower limit >-10%, upper limit >0%). Both studies assessed safety. RESULTS: In 22 healthy participants, the impact on MCC did not differ between HFA-134a and HFA-152a (AUC0-4h geometric mean ratio [90% CI]: 1.00 [0.99,&#xa0;1.01]). In 19 patients with mild asthma, neither HFA-152a nor HFA-134a induced bronchoconstriction (percent change in FEV1 at 15&#x202f;min: -0.37% [HFA-152a] vs -0.60% [HFA-134a]); HFA-152a was non-inferior to HFA-134a (mean difference [95% CI]: 0.23% [-3.61,&#xa0;4.07]). Adverse event (AE) rates were low and similar for both propellants in both studies; all AEs were mild, with no serious AEs or deaths. CONCLUSION: HFA-152a and HFA-134a had almost identical effects on MCC, neither induced bronchoconstriction, supporting MDI reformulation with the low-GWP propellant HFA-152a.

Humans

Robotic Needle Insertion for CT-guided Percutaneous Biopsy of Thoracoabdominal Lesions: A Prospective Multicenter Randomized Trial.

Purpose To compare safety and feasibility between a novel CT-guided robotic system and the conventional freehand technique for puncture biopsy of thoracoabdominal lesions. Materials and Methods In this prospective multicenter randomized trial, individuals with suspected lesions were enrolled between July 2023 and April 2024 across three university teaching hospitals and randomized to the robot-assisted group (n = 82) or the freehand group (n = 83). Procedure outcomes included the technical success rate, targeting error, number of CT scans and needle adjustments, puncture time, and complications. Descriptive and inferential statistics were calculated. Results A total of 165 participants (mean age, 60 years &#xb1; 10 [SD]; 83 male) were included. Compared with the freehand group, the robot-assisted group demonstrated a higher technical success rate (97.56% [80 of 82] vs 62.65% [52 of 83], P < .001), lower targeting error (mean Euclidean deviation: 1.7 mm &#xb1; 1.1 vs 4.5 mm &#xb1; 3.9, P < .001), and fewer CT scans (mean, 4.3 &#xb1; 1.9 vs 5.2 &#xb1; 2.3; P = .002) and needle adjustments (mean, 0.7 &#xb1; 0.7 vs 1.6 &#xb1; 1.6; P = .003). Despite differences in geometric precision, both groups achieved 100% (82 of 82 and 83 of 83) diagnostic yield. The median puncture time was comparable between groups (5.5 minutes &#xb1; 4.3 vs 4.8 minutes &#xb1; 7.0, P = .50). During lung biopsies, the robot-assisted approach yielded fewer complications compared with the freehand approach (4.88% [four of 82] vs 16.87% [14 of 83], P = .014). Conclusion Compared with the freehand approach, robot-assisted biopsy yielded greater precision and reduced adjustments and complications while demonstrating noninferior diagnostic efficacy and comparable duration. Keywords: Robotic Needle Insertion, Biopsy, Thoracoabdominal Lesions, Robot-assisted Biopsy, CT-guided Intervention, Percutaneous Needle Biopsy, Randomized Controlled Trial, Algorithm Development, CT, Clinical Testing, Interventional-Body, Biopsy/Needle Aspiration, Percutaneous, Thorax, Abdomen/GI, Liver, Lung, Kidney &#xa9;RSNA, 2026.

Humans

Effects of Acute Low- and Moderate-Dose Alcohol on Chronic Disease-Related Biomarkers in Healthy Light and Heavy Drinkers.

BACKGROUND: Alcohol consumption is a major contributor to global chronic disease, with growing evidence indicating health risks even at low levels of intake. However, mechanistic understanding of these risks relies heavily on preclinical models and observational data, leaving a critical gap in controlled experimental evidence regarding how alcohol perturbs human biological systems in&#xa0;vivo. METHODS: The present study utilized plasma samples from a randomized, placebo-controlled trial to evaluate the effects of low-dose (0.35&#x2009;g/kg) and moderate-dose (0.60&#x2009;g/kg) alcohol on disease-relevant biomarkers in 32 healthy adults (mean age&#x2009;=&#x2009;25.0&#x2009;&#xb1;&#x2009;3.8&#x2009;years; 21 female/11 male), characterized by light (n&#x2009;=&#x2009;15) or heavy (n&#x2009;=&#x2009;17) drinking. This design enabled evaluation of effects across dose, timescale, and drinking history, as well as assessment of their interactions. Plasma was collected at prebeverage baseline and hourly for 4&#x2009;h afterward. Immunoassays quantified 10 disease-related biomarkers: adiponectin, angiogenin, D-dimer, high-sensitivity C-reactive protein (hsCRP), Intercellular Adhesion Molecule-1 (ICAM-1), Lipocalin-2 (LCN2), Matrix Metalloproteinase-7 (MMP-7), Matrix Metalloproteinase-9 (MMP-9), soluble Receptor for Advanced Glycation End-products (sRAGE), and Triggering Receptor Expressed on Myeloid cells 2 (TREM2). RESULTS: Main effects of group indicated that even in this young healthy sample, heavy drinking status was associated with higher levels of adiponectin, angiogenin, ICAM-1, LCN2, and sRAGE, a profile suggesting altered vascular and metabolic activity. Acute alcohol administration induced changes in sRAGE and hsCRP. Specifically, moderate-dose alcohol triggered an increase in the immunoglobulin sRAGE, which may reflect an acute compensatory response to inflammation and/or oxidative stress. Compared to placebo, hsCRP was lower in the low-dose alcohol condition; however, this finding should be interpreted in light of CRP biology. MMP-7, MMP-9, and LCN2 showed time-dependent fluctuations that were independent of experimental condition, highlighting the critical importance of placebo-controlled designs to account for diurnal/postprandial variation in immune biomarkers. CONCLUSION: Findings provide translational evidence that alcohol is associated with multisystem biomarker changes relevant to chronic disease and that alcohol-related biomarker perturbations vary by dose and chronicity.

Humans

Daily low-dose carboplatin or weekly carboplatin plus nab-paclitaxel for concurrent chemoradiotherapy in older patients with locally advanced non-small cell lung cancer (JCOG1914): A randomized phase 3 trial.

BACKGROUND: Daily low-dose carboplatin with concurrent thoracic radiotherapy is the standard treatment for older patients with unresectable locally advanced non-small cell lung cancer (LA-NSCLC) in Japan. METHODS: This open-label phase 3 trial was conducted at 38 institutions in Japan. Patients aged&#xa0;&#x2265;&#xa0;75&#xa0;years with LA-NSCLC were randomly assigned (1:1) to receive daily carboplatin (30&#xa0;mg/m2) or weekly carboplatin (area under the curve, 2&#xa0;mg&#xb7;min/mL) plus nab-paclitaxel (30&#xa0;mg/m2) with thoracic radiotherapy. Durvalumab maintenance therapy was recommended after treatment completion. The primary endpoint was overall survival, which was used to assess the non-inferiority of weekly carboplatin plus nab-paclitaxel compared to daily low-dose carboplatin. RESULTS: From December 2020 to March 2024, 124 patients were enrolled (carboplatin arm, 61 and carboplatin plus nab-paclitaxel arm, 63). In the planned interim analysis, the Bayesian predictive probability indicating the non-inferiority of carboplatin plus nab-paclitaxel compared with carboplatin in the final analysis was 8.0%, leading to early study termination for futility. The median overall survival was not estimable in the carboplatin arm; the estimated value in the carboplatin plus nab-paclitaxel arm was 26.1&#xa0;months (hazard ratio, 1.56; 95% confidence interval, 0.79-3.11; p&#xa0;=&#xa0;0.200). Two treatment-related and seven non-cancer-related deaths occurred in the carboplatin plus nab-paclitaxel arm. Patients in the carboplatin arm had better quality of life than those in the carboplatin plus nab-paclitaxel arm at 6&#xa0;weeks (odds ratio, 0.39; 95% confidence interval, 0.18-0.81; p&#xa0;=&#xa0;0.012). CONCLUSIONS: Daily low-dose carboplatin with concurrent thoracic radiotherapy remains the standard treatment for older patients with unresectable LA-NSCLC in Japan.

Humans

Discrepancies in CPAK classification between CT and long-leg radiography: a systematic review and meta-analysis.

OBJECTIVE: To determine whether substantial differences in coronal plane alignment of the knee phenotype distribution, as well as systematic angular measurement discrepancies, exist between CT and long-leg radiography. MATERIALS AND METHODS: From February 2021 to April 2025, we searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials for studies comparing CT- and long-leg radiography-derived coronal plane alignment classifications of the knee in patients with osteoarthritis. The primary outcome was distribution of coronal plane alignment phenotypes. Secondary outcomes included differences in medial proximal tibial angle, lateral distal femoral angle, arithmetic hip-knee-ankle angle, and joint line obliquity. RESULTS: Four studies (1,134 knees) were included. Compared with long-leg radiography-derived classification, CT-derived classification increased type I phenotypes (risk difference: 0.10; 95% confidence interval: 0.01-0.20; P&#x2009;=&#x2009;0.040) and decreased type III (risk difference: -0.04; 95% confidence interval: -0.07 to -0.01; P&#x2009;=&#x2009;0.020) and type V phenotypes (risk difference: -0.04; 95% confidence interval: -0.07 to -0.01; P&#x2009;=&#x2009;0.004). CT yielded significantly lower medial proximal tibial angle (weighted mean difference:&#x2009;-&#x2009;1.18&#xb0;; P&#x2009;<&#x2009;0.001), arithmetic hip-knee-ankle angle (weighted mean difference:&#x2009;-&#x2009;0.95&#xb0;; P&#x2009;<&#x2009;0.001), and joint line obliquity (weighted mean difference:&#x2009;-&#x2009;1.40&#xb0;; P&#x2009;<&#x2009;0.001) than long-leg radiography. Heterogeneity was high for type I phenotype (I2&#x2009;=&#x2009;81%), lateral distal femoral angle (I2&#x2009;=&#x2009;70%), and joint line obliquity (I2&#x2009;=&#x2009;69%). CONCLUSION: Discrepancies between CT-based software-generated and long-leg radiography-derived measurements substantially affect coronal plane alignment classification and angular parameters. Surgeons should consider these modality-specific variations and employ compensatory verification strategies to ensure optimal alignment.

Humans

Higher Rates of PASS and SCB After Arthroscopic Subspine Decompression Are Associated With a Positive Diagnostic AIIS Injection: A Propensity Score-Matched Cohort Study.

BACKGROUND: Hip arthroscopy effectively treats femoroacetabular impingement syndrome (FAIS), but persistent pain may be related to concomitant extra-articular pathology such as subspine impingement syndrome (SSI). Standard diagnosis of SSI often relies on 3-dimensional computed tomography (3D-CT) morphology (Hetsroni type II/III), although this morphology is common in individuals who are asymptomatic and correlates poorly with symptoms. PURPOSE: To compare minimum 2-year clinical outcomes after arthroscopic subspine decompression in patients with concurrent FAIS and type II/III anterior inferior iliac spine (AIIS) morphology, stratified by diagnostic method: 3D-CT morphology alone versus 3D-CT morphology plus a positive ultrasound-guided diagnostic injection. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: This study included patients aged 18 to 55 years with type II/III AIIS morphology who underwent primary hip arthroscopy for FAIS and SSI between January 2021 and November 2023 and had minimum 2-year follow-up. Patients diagnosed by CT morphology alone (CT classification group) were propensity score matched 1:1 to patients with a positive ultrasound-guided AIIS injection (injection group), with 57 patients per group. Matching variables were age, sex, body mass index, lateral center-edge angle, alpha angle, T&#xf6;nnis grade, and Beighton score. All patients underwent arthroscopic subspine decompression. Patient-reported outcomes and rates of achieving the minimal clinically important difference, Patient Acceptable Symptom State (PASS), and substantial clinical benefit (SCB) were compared. RESULTS: Preoperative patient-reported outcome scores were similar between groups (all P > .05). At minimum 2-year follow-up, the injection group had significantly better scores on the modified Harris Hip Score (90.8 vs 84.2), Hip Outcome Score-Activities of Daily Living (88.4 vs 82.4), Hip Outcome Score-Sports Subscale (71.9 vs 64.1), 12-item International Hip Outcome Tool (83.9 vs 76.1), and visual analog scale for pain (1.2 vs 2.0) (all P < .001). Minimal clinically important difference rates were high in both groups, with higher rates in the injection group for modified Harris Hip Score (93% vs 77%; P = .033) and Hip Outcome Score-Activities of Daily Living (91% vs 75%; P = .042). PASS and SCB rates were significantly higher in the injection group across all patient-reported outcome measures (all P < .05). Revision and complication rates were low and did not differ significantly between groups. CONCLUSION: Both groups improved significantly after arthroscopic subspine decompression. However, patients with a positive ultrasound-guided diagnostic AIIS injection achieved higher PASS and SCB rates than those selected by CT morphology alone, suggesting that injection-confirmed SSI may improve patient selection for subspine decompression.

Humans

Which radiographic plane should be used to quantify the distal tibia angle on weightbearing CT images?

BACKGROUND: Precise quantification of distal tibial alignment is essential for planning corrective osteotomies and ankle joint replacement surgery. The lateral distal tibial angle (LDTA) is the principal radiographic parameter used for this purpose. While LDTA is increasingly measured on weightbearing cone-beam CT (WBCT) using two-dimensional coronal slices, the optimal measurement plane remains unclear. METHODS: In this retrospective comparative study, full-leg WBCT scans of patients scheduled for supramalleolar osteotomy (n&#x202f;=&#x202f;20; mean age 47&#x202f;&#xb1;&#x202f;12.8 years) were analyzed. LDTA was measured on three coronal planes of the distal tibial plafond (anterior edge, mid-dome, posterior edge) and compared with semi-automated three-dimensional (3D) tibial alignment measurements as the reference standard. RESULTS: Mid-dome LDTA showed no significant difference from the 3D reference (p&#x202f;>&#x202f;0.05) and demonstrated excellent agreement. Anterior measurements significantly overestimated LDTA, while posterior measurements underestimated it (both p&#x202f;<&#x202f;0.05), with only fair agreement. CONCLUSION: LDTA should be measured at the mid-dome of the distal tibial plafond on WBCT to ensure accurate and reproducible alignment assessment. LEVEL OF EVIDENCE: Level III - Retrospective Comparative Study.

Humans

Efficacy and Safety of Ultra-Low Starting Dose Febuxostat Titration in Male Patients With Primary Gout.

BACKGROUND: Since gout is a common metabolic arthritis caused by urate crystal deposition, urate-lowering therapy (ULT) is clearly indicated, but the initiation of ULT frequently causes paradoxical acute flares that in turn impair patient adherence. OBJECTIVE: This study sought to assess the effectiveness and safety of an ultra-low-dose initiation strategy for febuxostat (10&#x2009;mg/day) compared to the standard starting dose (20&#x2009;mg/day) in reducing initiation-related flares while maintaining long-term urate control. METHODS: 120 male patients with primary gout presenting with acute arthritis were randomly assigned to initiate febuxostat at 10&#x2009;mg/day (Group A) or 20&#x2009;mg/day (Group B), with protocol-mandated biweekly titration. The primary outcomes were gout flare frequency over 24&#x2009;weeks (assessed using Poisson regression), serum uric acid (SUA) target attainment, and the incidence of adverse events. RESULTS: Although both groups achieved comparable target SUA levels by week 24, Group A demonstrated a significantly lower overall flare incidence (36.7% vs. 70.0%; p&#x2009;<&#x2009;0.001), along with a greater percentage of flare-free patients (70.0% vs. 46.7%; p&#x2009;=&#x2009;0.016). Multivariable Poisson regression revealed that Group B had an approximately twofold higher risk of flares compared to Group A (Incidence Rate Ratio&#x2009;=&#x2009;1.95; p&#x2009;=&#x2009;0.012), with obese patients deriving the most pronounced benefit from the ultra-low-dose approach. To avert one additional flare, the calculated number needed to treat was 4.3. Additionally, the occurrence of clinically significant liver injury (ALT/AST >&#x2009;3&#xd7; ULN) was low in both groups, with 3.3% in Group A and 1.7% in Group B. Multivariable regression analysis confirmed that LDL-C is an independent predictor of ALT (&#x3b2;&#x2009;=&#x2009;12.90, p&#x2009;=&#x2009;0.009), while febuxostat dosage was not linked to hepatotoxicity. CONCLUSION: Initiating febuxostat at a dose of 10&#x2009;mg/day with gradual titration demonstrates a superior safety profile by effectively reducing early acute flares without compromising long-term urate control, which is particularly advantageous for high-risk cohorts, including obese patients.

Humans

Impact of Commercial Artificial Intelligence on Radiologist Reading Time for Pulmonary Nodule Evaluation at Chest CT.

Background Chest CT is a primary method for identifying pulmonary nodules, yet interpreting scans remains time-intensive and demanding. Currently, artificial intelligence (AI) is expected to reduce reading times, but the effect of AI on reporting times in this setting is unknown. Purpose To evaluate the impact of a commercial AI software on radiologists' reading time for pulmonary nodule assessment on chest CT scans within a real-world clinical setting. Materials and Methods This retrospective study included patients who underwent chest CT examinations at a tertiary medical center between September 2021 and May 2024. The study period was divided into pre- and post-AI phases. The primary outcome was radiology reporting time. The association between AI implementation and reporting time was evaluated using a multivariable parametric Weibull shared frailty survival model adjusted for reader function, examination type, patient location, and requesting specialty, with clustering at the radiologist level. Interaction analyses assessed heterogeneity across prespecified subgroups. An exploratory extrapolation estimated projected workforce and financial impact. Results This study included 19&#x2009;433 patients (mean age, 62 years &#xb1; 14.2 [SD]; 21&#x2009;814 men; 39&#x2009;323 chest CT examinations, 19&#x2009;190 pre-AI, and 20&#x2009;133 post-AI). AI implementation was associated with faster report completion (adjusted hazard ratio, 1.17; 95% CI: 1.14, 1.21; P < .001). The adjusted median reporting time decreased from 21.3 minutes pre-AI to 18.2 minutes post-AI (14.6% reduction; P < .001). Heterogeneity was observed across reader function (P < .001), examination type (P = .048), and requesting specialty (P = .03). The largest relative reductions were observed for CT thorax electrocardiogram-gated examinations (-41.1%; P < .001) and thoracic radiologists (-25.0%; P < .001), whereas emergency department examinations showed increased median reporting time (7.1%; P < .001). At institutional scan volumes (approximately 20&#x2009;000-22&#x2009;000 chest CT examinations annually), exploratory modeling suggested an approximate reduction of 0.5 full-time equivalent radiologist workload. Conclusion Implementation of commercial AI-assisted pulmonary nodule assessment on chest CT scans reduced radiologist reporting time in a real-world clinical setting. &#xa9; The Author(s) 2026. Published by the Radiological Society of North America under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Iwasawa in this issue.

Humans

Effects of low-dose esketamine on early quality of recovery following minimally invasive esophagectomy: a multicenter, randomized controlled study.

BACKGROUND: Patients undergoing minimally invasive esophagectomy (MIE) frequently experience moderate-to-severe postoperative pain and anxiety-depressive symptoms, compromising postoperative quality of recovery (QoR). Esketamine is a promising adjunct for analgesia and anxiolysis; however, the effect of low-dose esketamine on patient-centered recovery outcomes in MIE remains unclear. METHODS: In this double-blinded, multicenter randomized controlled trial, patients scheduled for elective McKeown esophagectomy were allocated to esketamine (0.25&#x2009;mg/kg loading dose and 0.125&#x2009;mg/kg/h continuous infusion during surgery) or placebo (equivalent volume and rate of saline). The primary outcome was the QoR-15 score on postoperative day (POD) 2. Secondary outcomes included QoR-15 scores on POD 1, 3, 7 and 30. Hospital Anxiety and Depression Scale - Anxiety Subscale (HADS-A) and Depression Subscale (HADS-D) scores, numeric rating scale (NRS) pain scores, and the Brief Pain Inventory (BPI) scores on POD 1 to 3, and safety evaluations. RESULTS: A total of 198 patients were analyzed (esketamine, n&#x2009;=&#x2009;98; placebo, n&#x2009;=&#x2009;100). Intraoperative esketamine significantly improved QoR-15 scores on POD 2 (116.9&#x2009;&#xb1;&#x2009;9.4 vs. 110.2&#x2009;&#xb1;&#x2009;9.8, p&#x2009;<&#x2009;0.001) and POD 3 (123.6&#x2009;&#xb1;&#x2009;7.2 vs. 116.8&#x2009;&#xb1;&#x2009;8.4, p&#x2009;<&#x2009;0.001) compared with placebo. HADS-A and HADS-D scores were lower in the esketamine group on POD 1 to 3 (all p&#x2009;<&#x2009;0.001). Additionally, esketamine recipients reported significantly lower NRS scores at rest and during movement and BPI scores for pain severity and pain interference items (all p&#x2009;<&#x2009;0.001). There were no significant between-group differences in safety outcomes. CONCLUSIONS: Intraoperative low-dose esketamine improved early, patient-reported recovery after MIE by enhancing analgesia and reducing postoperative anxiety and depression without increasing adverse events. TRIAL REGISTRATION: Chinese Clinical Trial Register (identifier: ChiCTR2400088916).

Humans