Search PubMedSearch

SEARCH · Search PubMed

Results for “FS-LASIK”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

4 recordsLinked to original sources

Astigmatic vector outcomes after FS-LASIK versus SMILE for high myopic astigmatism: a single-center retrospective comparative cohort study without cyclotorsion compensation.

PURPOSE: To compare astigmatic correction vector outcomes between femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small-incision lenticule extraction (SMILE, also termed Keratorefractive Lenticule Extraction, KLEx) without intraoperative cyclotorsion compensation in patients with high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D), and to clarify procedure-specific correction tendencies under this non-standardized alignment protocol. METHODS: This single-center retrospective comparative cohort study enrolled 155 eyes (one eye randomly selected per patient) that underwent FS-LASIK (80 eyes) or SMILE/KLEx (75 eyes) for high myopic astigmatism correction from January 2023 to July 2024 in Beijing Fenglian Jiayue Lige Clinic. Intraoperative cyclotorsion compensation was intentionally disabled to isolate inherent procedural astigmatism correction characteristics. Standardized Alpins vectorial analysis was performed at 3&#xa0;months and 12&#xa0;months postoperatively. PRIMARY ENDPOINT: 12-month Alpins correction index (CI). Multivariable propensity score adjustment was applied to mitigate confounding by clinical treatment selection bias. Statistical multiplicity control was implemented for secondary vector and visual outcomes. RESULTS: Baseline demographic, refractive, corneal and ocular biometric parameters were balanced between groups after propensity matching. No statistically significant intergroup differences were detected in uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), residual cylinder, safety index or efficacy index at 3 and 12&#xa0;months (all P&#x2009;>&#x2009;0.05). Under the non-cyclotorsion-compensated protocol, significant intergroup differences were identified in the magnitude of surgically induced astigmatism (SIA), correction index (CI), and magnitude error (ME) at both follow-up timepoints (all P&#x2009;<&#x2009;0.0001). Target induced astigmatism (TIA), difference vector (DV), index of success (IOS), and angle error (AE) magnitudes were comparable between groups (all P&#x2009;>&#x2009;0.05). The vector mean axis of DV differed significantly between groups at 3 and 12&#xa0;months (Watson-Williams circular test, all P&#x2009;<&#x2009;0.0001). No reoperations were documented in clinic medical records for either cohort. No standardized dry eye questionnaires, tear film testing or corneal nerve density metrics were collected to quantify dry eye adverse events; only unstructured clinical notes were reviewed for complication screening. CONCLUSIONS: Under surgical alignment without cyclotorsion compensation, FS-LASIK and SMILE/KLEx both yielded acceptable visual and refractive safety/efficacy for high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D) at 1-year follow-up, but demonstrated divergent astigmatism correction tendencies: FS-LASIK exhibited relative astigmatism overcorrection (vector mean DV:&#x2009;-&#x2009;0.35&#x2009;&#xb1;&#x2009;0.43 D&#x2009;&#xd7;&#x2009;91&#xb0;, CI&#x2009;>&#x2009;1), while SMILE/KLEx showed relative undercorrection (vector mean DV:&#x2009;-&#x2009;0.21&#x2009;&#xb1;&#x2009;0.53 D&#x2009;&#xd7;&#x2009;12&#xb0;, CI&#x2009;<&#x2009;1). These correction biases are specific to the study's manual limbal alignment protocol without cyclotorsion tracking and cannot be generalized to modern optimized surgical platforms equipped with automated cyclotorsion compensation. Residual refractive errors across both groups are likely multifactorial, including differential corneal stromal healing responses, divergent femtosecond/excimer laser tissue modification mechanisms, and uncorrected intraoperative ocular cyclotorsion.

Humans

Comparative genomics and full-length transcriptome profiling of wing morphs in Tetrix grossus (Orthoptera: Tetrigidae).

Wing polymorphism represents a paradigmatic dispersal-reproduction trade-off, yet its molecular basis remains uncharacterised in the phylogenetically distant pygmy grasshoppers (Tetrigidae). Here we integrate comparative genomics across ten orthopteran species with full-length transcriptomics of long-winged (FL) and short-winged (FS) Tetrix grossus. OrthoFinder recovered 118 orthogroups specific to T. grossus. Against a backdrop of pronounced gene-family contraction (36 expansions versus 222 contractions; net -186, mirrored at the ancestral Tetrix node, +37/-140), we identified an ancestral, Tetrix-specific expansion of hormone-regulation (12 genes; fold enrichment 7.93) and lipid/carbohydrate-metabolic families organised into syntenic clusters, alongside 513 positively selected genes enriched for integrin-mediated cell adhesion (6 genes), a process relevant to epithelial and appendage morphogenesis. Full-length transcriptomics of one long-winged (FL) and one short-winged (FS) adult female detected 7530 (FL) and 7515 (FS) expressed genes, with 794 FL- and 776 FS-restricted transcriptome-derived SNP-associated genes. The FL morph was enriched for an EGFR/Ras-Rho developmental-patterning axis and neuromuscular flight genes, whereas the FS morph was enriched for insulin/peptide-hormone response and growth-regulatory loci. Overall, we present genomic resources and testable hypotheses concerning the evolution and regulation of wing morphs in Tetrigidae rather than a validated genetic architecture of wing-morph determination.

Animals

[Analysis of clinical phenotypes and pathogenicity of a c.4476+5G>T variant of SCN1A gene in a Chinese pedigree affected with Genetic epilepsy with febrile seizures plus].

OBJECTIVE: To explore the pathogenicity and characteristics of a heterozygous splicing variant of SCN1A gene in a Chinese pedigree affected with Genetic epilepsy with febrile seizures plus (GEFS+). METHODS: A retrospective analysis was carried out on the clinical data and results of genetic testing of a GEFS+ pedigree consisting of 5 members who had visited the First Affiliated Hospital of Zhengzhou University on July 1, 2024. Pathogenicity of the splicing variant of the SCN1A gene was validated with a minigene splicing assay. This study was approved by the Medical Ethics Committee of the the First Affiliated Hospital of Zhengzhou University (Ethics No.: KS-2018-KY-36). RESULTS: The proband, a 24-year-old female, presented with FS in conjunct with focal seizures, and both of her younger brothers had Dravet syndrome. All of the three patients had carried a c.4476+5G>T variant of the SCN1A gene, which was unreported previously. Minigene experiment verified that the variant could cause loss of the first 7 bps of exon 24 and 138 bps from exon 23 of the SCN1A gene, resulting in alteration p.V1447_1495delfs*6 and affecting splicing. Based on the guidelines from American College of Medical Genetics and Genomics (ACMG), the variant was predicted as likely pathogenic (PVS1+PM2_Supporting). CONCLUSION: The c.4476+5G>T variant at an intronic site of the SCN1A gene probably underlay the pathogenesis of GEFS+ in this pedigree.

Adult

Second-Generation ELZA-sub400 Protocol: Individualized High-Fluence Cross-Linking for Ultra-Thin Keratoconus Corneas.

PURPOSE: To evaluate the safety and efficacy of a second-generation individualized corneal cross-linking (CXL) protocol (ELZA-sub400) using high-fluence UV-A irradiation in ultrathin ectatic corneas. DESIGN: Retrospective, single-center, consecutive interventional case series. METHODS: Twenty-nine eyes of 24 patients with progressive keratoconus or post-LASIK ectasia and a post-soak intraoperative thinnest stromal thickness <400 &#xb5;m were included. After epithelial removal and riboflavin soaking, continuous UV-A irradiation (365 nm) at 3 or 9 mW/cm&#xb2; was delivered with total fluence titrated up to 10 J/cm&#xb2; based on intraoperative ultrasound pachymetry and a previously published nomogram targeting an uncross-linked stromal margin of approximately 70 &#xb5;m above the endothelium. Outcomes were assessed at baseline and up to 12 months using corrected distance visual acuity (CDVA) and corneal parameters measured using Scheimpflug tomography and anterior segment OCT (AS-OCT) with Placido-based topography. The main outcome measure was the proportion of eyes without progression at 12 months, defined as <1.0 D increase in maximum keratometry (Kmax). Secondary outcomes included changes in CDVA, refraction, Kmax, stromal thickness, demarcation line depth, densitometry, and safety parameters. RESULTS: At 12 months, 22/29 eyes (76%; 95% CI, 57.9%-87.8%) met the nonprogression criterion. Mean change in Kmax was -0.77 &#xb1; 5.10 D (95% CI, -2.71 to 1.17; P = .418). Mean demarcation line-to-anterior stroma distance was 205 &#xb1; 64 &#xb5;m (95% CI, 180.7-229.3), and demarcation line-to-endothelium distance was 64 &#xb5;m (IQR, 49-152). All demarcation lines remained within the stromal layer; 15/29 eyes (51.7%) had a demarcation line located &#x2264;70 &#xb5;m from the endothelium. Median CDVA changed from 0.10 to 0.32 logMAR (P = .142). Minimum stromal thickness showed a median change of -4.0 &#xb5;m (P = .309). No significant change was observed in densitometry, and no eye developed deep stromal haze or endothelial decompensation. CONCLUSIONS: Second-generation ELZA-sub400 CXL halted ectasia progression in 76% of ultrathin corneas at 12 months and was associated with an acceptable short-term safety profile, including stromal-confined demarcation line formation and no observed endothelial decompensation. The numerical decline in spectacle CDVA observed in this severely affected cohort did not reach statistical significance but is clinically important and warrants confirmation in larger prospective studies.

Humans