Results for “ECG”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

8 recordsLinked to original sources

Ultra-high-frequency ECG quantifies residual electrical dyssynchrony during left bundle branch area pacing in patients with wide QRS: a paired within-patient study.

BACKGROUND: Left bundle branch area pacing (LBBAP) may restore a more physiological pattern of ventricular activation in patients with conduction delay; however, QRS narrowing alone may incompletely characterize electrical resynchronization. Ultra-high-frequency ECG (UHF-ECG) provides quantitative markers of ventricular activation timing and dyssynchrony. OBJECTIVE: To quantify paired OFF-to-ON changes in conventional ECG and UHF-ECG metrics during LBBAP in patients with baseline wide QRS and to assess the relationship between paced R-wave peak time (RWPT) and residual UHF-ECG dyssynchrony. METHODS: In this prospective single-center paired study, 21 patients with bradycardia and baseline wide QRS underwent standard ECG and UHF-ECG assessment during intrinsic rhythm (pacing OFF) and during LBBAP (pacing ON). Endpoints included QRS duration, signed VED16, absolute VED16 (|VED16|), mean ventricular delay (meanVD), and a clinically interpretable distance-to-normal metric defined as dist&#xa0;=&#xa0;max(|VED16|-20, 0). Paired changes were summarized as medians with bootstrap 95% confidence intervals and tested using the Wilcoxon signed-rank test. Associations between paced RWPT and residual dyssynchrony during pacing were evaluated using Pearson and Spearman correlation coefficients. RESULTS: LBBAP significantly narrowed QRS duration from 136.8 [130.2-153.6] ms during intrinsic rhythm to 116.0 [107.8-125.6] ms during pacing (median &#x394; -21.0&#xa0;ms; 95% CI -33.9 to -18.6; p&#xa0;<&#xa0;0.001). Signed VED16 did not change significantly (median &#x394; 0.4&#xa0;ms; p&#xa0;=&#xa0;1.000), consistent with the mixed conduction-phenotype composition of the cohort. In contrast, severity-oriented UHF-ECG endpoints improved: |VED16| decreased numerically (median &#x394; -5.2&#xa0;ms; p&#xa0;=&#xa0;0.070), whereas dist decreased significantly (median &#x394; -0.7&#xa0;ms; 95% CI -14.4 to 0.0; p&#xa0;=&#xa0;0.015). The proportion of patients within the normal dyssynchrony band (|VED16|&#xa0;&#x2264;&#xa0;20&#xa0;ms) increased from 7/21 (33.3%) to 12/21 (57.1%). Median paced RWPT was 66.6 [58.6-74.6] ms, and shorter RWPT correlated with lower residual |VED16| during pacing (Pearson r&#xa0;=&#xa0;-0.45, p&#xa0;=&#xa0;0.038). CONCLUSIONS: In patients with baseline wide QRS, LBBAP produces marked QRS narrowing, whereas UHF-ECG provides complementary quantification of residual electrical dyssynchrony. Severity-oriented UHF-ECG endpoints, particularly a distance-to-normal metric, may offer an interpretable mechanistic framework beyond conventional ECG alone. Shorter paced RWPT was associated with lower residual dyssynchrony during pacing, supporting physiological coherence between procedural and high-resolution electrocardiographic markers.

Humans

Reliability-aware hierarchical learning for Chagas disease screening from 12-lead ECGs: tackling label uncertainty and class imbalance.

Objective.Chagas disease, a neglected tropical disease (NTD) with significant cardiovascular impact, remains underdiagnosed in resource-limited regions. Electrocardiogram (ECG) screening offers a low-cost tool for detecting cardiac involvement, yet algorithm development is challenged by label noise, data scarcity, and the latent nature of infection. This study proposes a robust ECG-based screening framework that explicitly addresses these constraints.Approach.We introduce aReliability-Aware Hierarchical Learningstrategy that calibrates supervision according to data provenance, prioritizing serology-confirmed labels over noisy self-reports. To mitigate data scarcity, we compare a specialized convolutional neural network (CNN) trained from scratch with a transfer learning approach based on a Spatio-Temporal ECG foundation Model (FM). Performance is evaluated across varying data scales, and the representation structure is analyzed to interpret model behavior.Main results.On the official hidden test set of the George B. Moody PhysioNet/Computing in Cardiology Challenge 2025, our approach achieved a Challenge Score of 0.163. We observe that while the specialized CNN performs competitively in data-rich regimes, the FM exhibits superior robustness in extreme low-resource settings. Furthermore, performance reaches a plateau imposed by underlying disease physiology. Bimodal score distributions suggest that models distinguish established cardiomyopathy from indeterminate infection, which remains electrophysiologically indistinguishable from healthy controls.Significance.These findings clarify both the potential and intrinsic limits of ECG-based AI screening for NTD-associated cardiac involvement. Reliability-aware supervision and data-efficient transfer learning provide a practical framework toward scalable and clinically meaningful ECG screening systems in resource-constrained environments.

Humans

Teaching Acute Coronary Syndrome High-Risk ECG Interpretation and Clinical Decision-Making Through FOAMed Videos and Podcast Versus Print-Based Materials Among Emergency Care Providers: Randomized Controlled Mixed Methods Trial.

BACKGROUND: Accurate interpretation of high-risk acute coronary syndrome (ACS) electrocardiograms (ECGs) is essential for early diagnosis and timely reperfusion, yet substantial deficits persist across health care professions. Digital self-learning formats such as FOAMed (Free Open Access Medical Education) are widely used, but their effectiveness has rarely been evaluated for complex, high-risk ACS ECG patterns. Existing ECG education studies often focus on students or single professional groups and established ST-segment elevation myocardial infarction (STEMI) criteria, leaving newer guideline-recognized STEMI equivalents, selected emerging occlusion myocardial infarction (OMI)-related patterns, and interprofessional emergency care underrepresented. OBJECTIVE: This study aimed to compare the effectiveness of FOAMed podcast and videos versus traditional print-based materials for teaching high-risk ACS ECG patterns and related clinical decision-making in emergency providers. METHODS: We conducted a prospective, interprofessional, controlled mixed methods trial across 5 training sites in Germany. Paramedics, prehospital emergency physicians, and emergency department clinicians received either a FOAMed multimedia module or print-based materials through concealed allocation; deviations from the intended 1:1 ratio resulted from participant no-shows. The intervention consisted of a 30-minute supervised self-learning session. In total, 103 participants were allocated to FOAMed (n=45) or print-based materials (n=58). Two coprimary outcomes were assessed: ECG interpretation accuracy and text-based ACS clinical decision-making. Secondary outcomes included subjective confidence, learning experience, and exploratory qualitative free-text responses. Outcome assessment was automated and blinded; mixed ANOVA was the primary analysis. The study was not prospectively registered because it assessed educational outcomes in health care professionals rather than patient health outcomes. RESULTS: All 103 participants completed the study. Both groups improved, with greater gains in the FOAMed group: ECG interpretation increased from 55% to 65.5% and text-based ACS clinical decision-making from 45% to 68%, versus 57% to 60% and from 47% to 63%, respectively, in the print-based group. Effect sizes were &#x3b7;&#xb2;=0.055 for ECG interpretation and &#x3b7;&#xb2;=0.044 for clinical decision-making. Exploratory subgroup analyses provided no evidence of differential effects across age, gender, or professional background and were likely underpowered. Qualitative responses (46 and 37 entries) provided contextual insights into perceived clarity, engagement, and practical relevance supporting the quantitative findings. CONCLUSIONS: This study is innovative in directly comparing a curated FOAMed multimedia module with selected print-based materials in an interprofessional emergency care population. It differs from existing research by focusing on subtle, emerging ischemic patterns and evaluating realistic, time-limited self-learning formats. The findings provide evidence that curated FOAMed resources can produce greater short-term improvements in ECG interpretation and text-based ACS clinical decision-making than traditional print-based materials in this setting. Although implications for clinical performance remain hypothetical, concise, high-quality digital modules may represent a practical supplement to structured continuing education in emergency care.

Humans

First evaluation of a novel recombinant eCG molecule in ewes reveals a discrepancy between ovulatory response and pregnancy outcome.

This study evaluated the reproductive performance and clinical safety of a novel recombinant eCG (r-eCG) in ewes. Two weeks prior to study onset (Day 0: intravaginal progesterone device insertion), 45 ewes were randomly assigned to negative control (NC; no eCG; n&#x202f;=&#x202f;10), positive control (PC; 400IU commercial non-recombinant eCG; n&#x202f;=&#x202f;20), or treatment group (T; 400IU r-eCG; n&#x202f;=&#x202f;15). Ewes were inseminated with fresh-diluted semen (200&#x202f;&#xd7;&#x202f;106 sperm). Ultrasonography assessed follicle count/diameter (days 11, 13), ovulation (day 13), corpus luteum (CL) number/characteristics (day 20), and pregnancy (day 44). Serum progesterone was measured on day 20; Group T underwent clinical/hematological evaluations (days 0, 20, and 44). Estrus signs were more frequent (P&#x202f;<&#x202f;0.01) in T (100%) than NC (50%), while PC (85%) did not differ. Ovulation rates were similar between T (93%) and PC (95%), but higher than NC (50%; P&#x202f;<&#x202f;0.05). On day 13, largest follicle diameter did not differ (P&#x202f;>&#x202f;0.05) among groups; however, fewer follicles > 2&#x202f;mm occurred in PC than NC and T (P&#x202f;<&#x202f;0.05). CL number was higher in T than PC (2.0&#x202f;&#xb1;&#x202f;0.3 vs. 1.0&#x202f;&#xb1;&#x202f;0.0, P&#x202f;<&#x202f;0.01), while NC did not differ (1.0&#x202f;&#xb1;&#x202f;0.25). Conversely, pregnancy rate was higher (P&#x202f;<&#x202f;0.05) in PC (70%) than T (28.6%) and NC (20%). Among ovulated ewes, progesterone concentration and progesterone/CL ratio did not differ among groups (P&#x202f;=&#x202f;0.92 and P&#x202f;=&#x202f;0.08, respectively). No relevant r-eCG-related clinical or hematological alterations occurred. In conclusion, 400IU r-eCG effectively induces estrus and ovulation without adverse effects; however, the discrepancy between ovulatory response and pregnancy rate underscores the need for further study refinement to improve fertility.

Animals

Evaluation of the difference between automated and measured QTc intervals in children.

BACKGROUND: The corrected QT interval (QTc) is obtained through automated ECG computations or manual physician measurements. We hypothesized that differences exist in children between the measured and automated QTc intervals within and between Healthy and hypertrophic cardiomyopathy (HCM) subjects with greater differences for HCM due to structural abnormalities. METHODS: QT measurements - Bazett correction- automated (aQTc) and measured (mQTc), were extracted from the GE MUSE database for 385 Healthy pediatric (single ECG) and 208 HCM subjects (2 ECGs), stratified by age&#xa0;<&#xa0;12 and&#xa0;&#x2265;&#xa0;12&#xa0;yrs., sex, race, and ethnicity. QTc means (SD), automated and measured differences, and the difference of the differences of aQTc and mQTc were analyzed overall and by subgroups. All ECGs were read by one pediatric cardiologist with a second cardiologist reading a random subset of HCM ECGs to evaluate intraclass correlations and agreement. RESULTS: The mQTc intervals were shorter than aQTc intervals within Healthy (p&#xa0;<&#xa0;0.001) and within first HCM ECGs (p&#xa0;<&#xa0;0.001) with both aQTc and mQTc shorter in Healthy than HCM (p&#xa0;<&#xa0;0.001). The difference in these differences was significant overall using HCM ECG 1 but not HCM ECG 2. Healthy subject aQTc and mQTc intervals differed by age, sex, and race (p&#xa0;<&#xa0;0.002). HCM ECG 1 aQTc- mQTc intervals differed for age&#xa0;<&#xa0;12&#xa0;yrs., as well as by sex and race. HCM ECG 2 intervals differed only for age&#xa0;<&#xa0;12&#xa0;yrs. CONCLUSIONS: Compared to measured values, automated QTc values were significantly longer in both Healthy and HCM subjects. Automated measurements may overestimate the QTc.

Humans

Comparison between measured and synthesized posterior lead electrocardiograms during percutaneous coronary intervention-induced myocardial ischemia.

BACKGROUND: Posterior/inferolateral myocardial ischemia is frequently underrecognized on standard 12&#x2011;lead electrocardiography (ECG). Synthesized posterior leads derived from the standard 12&#x2011;lead ECG have been proposed as an alternative to directly measured posterior leads; however, their accuracy under controlled ischemic conditions has not been fully validated. METHODS: We prospectively enrolled 26 consecutive patients undergoing percutaneous coronary intervention (PCI) in whom simultaneously recorded measured and synthesized posterior lead ECGs (V7-V9) were obtained during balloon-induced myocardial ischemia. ST-segment deviation was measured at the ST junction (STJ), 40&#xa0;ms (ST1), and 80&#xa0;ms (ST2) thereafter. Agreement between measured and synthesized posterior leads was assessed using Pearson correlation and Bland-Altman analyses. As an exploratory patient-level analysis, diagnostic performance was compared with reciprocal anterior ST-segment depression (V1-V4). RESULTS: Strong correlations were observed between measured and synthesized posterior lead ST-segment deviations (V7: r&#xa0;=&#xa0;0.89; V8: r&#xa0;=&#xa0;0.86; V9: r&#xa0;=&#xa0;0.83; all P&#xa0;<&#xa0;0.001). Bland-Altman analysis demonstrated minimal systematic bias (within &#xb1;0.004&#xa0;mV) and narrow limits of agreement. Synthesized posterior leads showed higher diagnostic performance than reciprocal anterior ST-segment depression (AUC 0.917 vs. 0.708), although the difference was not statistically significant (DeLong test, P&#xa0;=&#xa0;0.197). Using a 0.05&#xa0;mV threshold, synthesized posterior leads demonstrated 83.3% sensitivity, 100% specificity, and 96.2% overall accuracy. CONCLUSIONS: Synthesized posterior leads closely reproduced measured posterior lead ST-segment deviations during percutaneous coronary intervention (PCI)-induced myocardial ischemia, supporting the technical validity of posterior lead reconstruction. Larger prospective studies are warranted to determine whether synthesized posterior leads provide incremental diagnostic value beyond careful interpretation of the standard 12&#x2011;lead ECG.

Humans

Electrocardiographic correlates of pacing induced cardiomyopathy and response to cardiac resynchronization therapy.

BACKGROUND: Chronic right ventricular (RV) pacing (RVP) causes pacing-induced cardiomyopathy (PICM) in only a small number of patients. We evaluated ECG correlates of (i) PICM and (ii) response to cardiac resynchronization therapy (CRT) upgrade. METHODS: We conducted a retrospective case-control study by including all CRT upgrades for PICM (LVEF <50%) at our center between 2014 and 2018. Controls were patients with &#x2265;5 ECGs all demonstrating RVP over &#x2265;2&#xa0;years and all echocardiographic LVEF &#x2265;50%. Root-summed-squared (3D) ECG was obtained from reconstructed vectorcardiographic X-Y-Z leads. Predictors of PICM and CRT response were assessed as area under ROC curve (AUC) for pre-CRT and &#x394; (post-CRT - pre-CRT) ECG intervals and QRS voltage-time-integrals (VTI). RESULTS: We included 104 patients with CRT upgrade for PICM (age 73.7&#xa0;&#xb1;&#xa0;10.5&#xa0;years, female 29.1%, QRS duration 167.8&#xa0;&#xb1;&#xa0;25.2&#xa0;ms, LVEF 28.8&#xa0;&#xb1;&#xa0;8.0%, &#x394;LVEF 13.8&#xa0;&#xb1;&#xa0;10.3%) and 178 controls without PICM (age 73.2&#xa0;&#xb1;&#xa0;14.9&#xa0;years, female 52.8%, QRS duration 144.0&#xa0;&#xb1;&#xa0;20.9&#xa0;ms, LVEF 56.7&#xa0;&#xb1;&#xa0;5.2%). PICM was best identified by VTIQRS-3D (AUC 0.851; VTIQRS-3D&#xa0;&#x2265;&#xa0;80 &#x3bc;Vs sensitivity 87.5%, specificity 63.5%), VTIQRS-Y (0.846), and QRS duration (0.775). CRT response (LVEF increase &#x2265;10% at 3-12&#xa0;months) occurred in 73/104 (70.2%) patients. Lack of CRT response was best predicted by longer pre-CRT QRS duration (AUC 0.640; QRS duration &#x2265;180&#xa0;ms sensitivity 45.2%, specificity 83.6%), and less &#x394;VTIQRS-3D (0.609) and &#x394;VTIQRS-X (0.608). CONCLUSION: In patients with chronic RVP, VTIQRS-3D&#xa0;&#x2265;&#xa0;80 &#x3bc;Vs can be used as a screening test for echocardiographic confirmation of PICM. RV-paced QRS duration >180&#xa0;ms, on the other hand, identifies those who may not respond to CRT upgrade.

Humans

A Phase I Study Assessing the Safety, Tolerability, and Pharmacokinetics of Yinfenidone: A Novel, Potent Drug for Idiopathic Pulmonary Fibrosis Treatment in Healthy Chinese Subjects.

PURPOSE: Idiopathic pulmonary fibrosis (IPF) is a fatal interstitial lung disease with a median survival of only 2-3 years after diagnosis. Yinfenidone (HEC585) possesses the potential to inhibit the proliferation of pulmonary fibroblasts, making it a promising candidate for the treatment of IPF. This study assessed the safety, tolerability, pharmacokinetics, and metabolic profile of Yinfenidone hydrochloride capsule in healthy Chinese subjects. METHODS: This single-center, randomized, double-blind, placebo-controlled, single ascending-dose trial included seven dose groups(20, 50, 100, 200, 400, 600, and 800 mg). Each group enrolled8 healthy subjects: 6 received Yinfenidone hydrochloride capsules and 2 received matching placebo under fasting conditions. Serial pharmacokinetic (PK) blood samples were collected pre-dose and post-dose, liquid chromatography-tandem mass spectrometry was used to analyze the plasma concentrations of Yinfenidone. Additionally, metabolic biotransformation of Yinfenidone in plasma were conducted in the 100 mg dose group. Safety and tolerability endpoints were monitored via physical examinations, vital signs measurements, clinical laboratory tests, 12-lead electrocardiography (ECG), and adverse events (AEs) documentation throughout the trial. FINDINGS: Yinfenidone was rapidly absorbed, with a median maximum plasma concentration (Tmax) of 1.8-3.0 hours, and had a mean half-life (t1/2) ranging from 31.9 to 62.0 hours. Within the 20-100 mg dose range, systemic drug exposure generally increased with ascending dose, above 100 mg, exposure increased less than proportionally to dose. Metabolite profiling in the 100 mg group revealed that the parentcompound predominated in plasma, with metabolic pathways including mono-oxygenation and N-dealkylation. All reported AEswere mild, classified as Common Terminology Criteria for Adverse Events (CTCAE) version 4.03 grade 1. No serious AEs observed; no subject discontinued the trial due to AEs. Single oral doses of 20-800 mg Yinfenidone hydrochloride capsules administered under fasting conditions demonstrated favorable safety and tolerability profiles in healthy Chinese subjects. IMPLICATIONS: Yinfenidone exhibited rapid absorption (median Tmax, 1.8-3.0 hours) and a long terminal t1/2 ranging from 31.9 to 62.0 hours in this single ascending-dose study, indicating that Yinfenidone can be taken once a day in subsequent clinical studies. Yinfenidone mainly exists in human plasma as the original drug and is metabolized through a variety of metabolic pathways. The AEs observed with Yinfenidone in this study, such as diarrhea, nausea, and dizziness, were similar to those reported with pirfenidone. Overall, Yinfenidone demonstrated a favorable safety and tolerability profile in this cohort of healthy subjects.

Adult