Automated CEAP Classification of Venous Duplex Reports Using Multimodal Artificial Intelligence.

OBJECTIVE: To develop and internally validate a prototype multimodal artificial intelligence system for automated CEAP (Clinical, Etiological, Anatomical and Pathophysiological) classification of venous duplex ultrasound (VDUS) reports, integrating natural language processing of free-text components with computer vision analysis of hand-drawn anatomical diagrams. METHODS: Single centre retrospective observational study using routinely collected clinical data. One thousand consecutive venous duplex ultrasound reports from Cambridge University Hospitals NHS Foundation Trust, UK (July 2024 - May 2025) were labelled according to the CEAP classification, excluding the Etiological component, which could not be reliably determined from duplex reports alone. Transfer learning was applied using ClinicalBERT for text and MobileNetV3 for diagrammatic data. Clinical classes were predicted from request line text. Text- and image-based pathophysiological models were developed for four anatomical territories (Great Saphenous Vein, Small Saphenous Vein, Deep system, Perforators), combined using late fusion with probability averaging. RESULTS: The clinical CEAP model achieved accuracy of 0.91, macro-F1 of 0.82, and macro-AUC of 0.98. Pathophysiological prediction varied, with text models broadly outperforming image models. Fusion yielded heterogeneous benefits, improving SSV performance but reducing Deep system accuracy. The performance of the final pathophysiological CEAP fusion models varied across anatomical territories: accuracy ranged from 0.70-0.92 and macro-AUC from 0.80-0.92. CONCLUSION: This study demonstrates the feasibility of automated CEAP classification from VDUS reports. Despite class imbalance affecting minority class predictions, the strong discriminatory performance validates this multimodal ML model for extracting clinically meaningful information from real-world data. This approach offers potential, pending external validation, to streamline vascular services through automated triage and guideline-compliant decision making.

Artificial intelligence

Real-time intraoperative perfusion assessment using indocianine green in pediatric extrinsic ureteropelvic junction obstruction with crossing vessel.

INTRODUCTION: In vascular hitch (VH) particular attention must be paid to preserving lower pole perfusion. Hypoperfusion is normally excluded by macroscopic visual assessment of parenchyma appearance. Our aim is to explore the possible role of indocyanine green (ICG) in highlighting focal hypoperfusion. MATERIALS AND METHODS: This prospective study included pediatric patients with UPJO caused by crossing vessels, treated with robot-assisted VH. Intraoperative evaluation assessed UPJ appearance, reduction of hydronephrosis after vessel mobilization, and the adequacy of pelvic drainage during diuretic testing. ICG was used to assess renal perfusion via NIRF imaging. A 25 mg ICG solution was prepared in 10 mL and administered in 1 mL doses. Fluorescence distribution, operative time, and complications were recorded. Follow-up at 3, 6, and 12 months included clinical evaluations, blood pressure measurements, and Doppler ultrasound. RESULTS: Eight patients (median age 8years) were enrolled between October 2023 and February 2025. ICG assessed renal perfusion post-procedure; one case of focal hypoperfusion due to vessel tension was resolved with intraoperative revision. At a median follow-up of 18 months, no hypertension, pain, or UTIs were observed. Ultrasound demonstrated improved hydronephrosis and normal Doppler flow. CONCLUSION: ICG angiography is a safe and effective tool for the real-time assessment of renal perfusion during pediatric VH procedures.

Humans

A child and young person focused systematic review of scrotal ultrasound with Mitigants to identify missed torsion.

BACKGROUND: Diagnostic accuracy of ultrasound for adults is stated as excellent. Paediatric and adult acute scrotal diseases are different. Findings in adults may not apply in children. The authors have seen overconfidence and interpretation with adult disease in mind in children with scrotal pain and have seen testicular loss as a result. OBJECTIVES: To interrogate the literature methodologically to report diagnostic accuracy of ultrasound (US) for the acute scrotum specifically in CYP with a follow-up methodology which allows identification of missed torsion. STUDY DESIGN: We performed systematic review and meta-analysis of studies reporting true diagnostic accuracy of ultrasound for testicular torsion (TT). PubMed, MEDLINE, Scopus, and Web of Science databases were searched from platform start until September 2023 using MeSH terms with protocol as detailed on PROSPERO. Multiple author search was undertaken. Two authors extracted data for included studies. Study quality was reported through QUADAS-2 methodology. Surgical findings or 12 months follow up in non-operative cases would be the gold standard to identify late atrophy due to missed torsion. Studies with methodology to identify missed torsion outwith the initial consult were included for meta-analysis. RESULTS: A total of 6790 cases were reported from the 38 papers identified. Studies were often flawed with poor definition of outcomes and short follow-up duration. Meta-analysis of the 10 high-quality studies revealed pooled sensitivity and specificity of 0.93 and 0.99. Doppler US by trained individuals demonstrated excellent diagnostic accuracy. Nonetheless, on extrapolation of the data, especially where flow was preserved, 5.6% of torsions were missed. DISCUSSION/CONCLUSION: Our review confirms a high diagnostic accuracy of US for TT in CYP. However, a 5.6% missed torsion rate was found if flow alone was considered diagnostic. The authors suggest US should be used as an adjunct in ambiguous cases, ensuring that clinically obvious torsion goes to theatre immediately and is not delayed by ultrasound. TRIAL REGISTRATION: PROSPERO: CRD42023412619.

Humans

Distal versus proximal radial access for diagnostic cerebral angiography: comparative outcomes and learning curve analysis.

BACKGROUND AND PURPOSE: Distal transradial access (dTRA) is an alternative to proximal transradial access (pTRA) for neuroangiography, but comparative real-world data and evidence on its early learning curve remain limited. We compared procedural performance and access-site complications between dTRA and pTRA and evaluated the early learning curve of dTRA. METHODS: We retrospectively analyzed 470 diagnostic cerebral angiography procedures, representing 421 unique patients, performed via radial access at a single center between January 2025 and February 2026, including 237 dTRA and 233 pTRA procedures. Baseline characteristics, including age, sex, body mass index (BMI) category, aortic arch type, and antiplatelet/anticoagulant use, procedural performance, and clinically assessed access-site events were compared between groups. Radial artery occlusion (RAO) was assessed by postoperative bedside pulse examination and confirmed with Doppler ultrasound when clinical findings were uncertain. Multivariable logistic regression was used to evaluate predictors of RAO, persistent bleeding or repeated compression, hand edema, and a composite access-site event endpoint. Because repeated procedures occurred in a subset of patients and event counts were limited, first-procedure sensitivity analysis and analyses of infrequent outcomes were interpreted cautiously. The dTRA learning process was assessed in the first 100 dTRA cases performed by a single operator using multivariable regression, cumulative sum (CUSUM) analysis, segmented trend analysis, and phase-based comparisons. RESULTS: Baseline characteristics were comparable between groups, including age, male sex, BMI category, aortic arch type, and antiplatelet/anticoagulant use. Compared with pTRA, dTRA was associated with more puncture attempts (3.0 [2.0-4.0] vs 2.0 [1.0-3.0], P&#xa0;<&#xa0;0.001), longer puncture time (2.0 [1.0-5.0] vs 2.0 [1.0-3.0] min, P&#xa0;=&#xa0;0.003), lower first-pass success (19.4% vs 35.2%, P&#xa0;<&#xa0;0.001), and a higher crossover rate (11.4% vs 6.0%, P&#xa0;=&#xa0;0.037). However, dTRA was associated with a lower clinically assessed RAO rate (2.5% vs 7.7%, P&#xa0;=&#xa0;0.011). On multivariable analysis, pTRA was independently associated with higher odds of RAO (OR 3.27, 95% CI 1.26-8.49, P&#xa0;=&#xa0;0.015) and the composite access-site event endpoint (OR 3.12, 95% CI 1.55-6.28, P&#xa0;=&#xa0;0.001). Similar findings were observed in a sensitivity analysis restricted to the first procedure per patient. In the first 100 dTRA cases, cumulative dTRA experience was independently associated with shorter total procedure time (beta&#xa0;=&#xa0;-0.074&#xa0;min/case, P&#xa0;=&#xa0;0.009), while CUSUM and moving-average analyses suggested that the major learning effect occurred within approximately the first 10-15 cases. CONCLUSIONS: In this retrospective single-operator cohort, dTRA was associated with lower clinically assessed RAO than pTRA despite greater access difficulty. The early learning effect was mainly reflected in shorter total procedure time. These findings support the feasibility of dTRA but should be interpreted cautiously given the study's observational design and limited anatomical data.

Humans