Search PubMedSearch

SEARCH · Search PubMed

Results for “Dental impression technique”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

249 recordsLinked to original sources

Comparison of short-term clinical outcomes and patient satisfaction between intraoral scanning and conventional impressions for complete-arch implant prostheses: a pilot RCT.

OBJECTIVE: To compare framework passive fit, subjective evaluations, and short-term clinical outcomes between conventional impressions (CI) and intraoral scanning (IOS) for complete-arch implant-supported fixed dental prostheses (CIFDPs). METHODS: In this randomized controlled trial, 22 patients were allocated to the CI or IOS groups. All participants received a definitive one-piece CIFDP. The primary outcome was framework passive fit, assessed using the Vision and Tactile Score (V&T score), which included framework lift-off, the single-screw test, the full-screw test, smoothness of screw insertion, and radiographic gap assessment. Secondary outcomes included operator evaluation, patient satisfaction using a visual analog scale (VAS), early implant survival, marginal bone loss (MBL), modified Plaque Index (mPII), and complications at the 6-month follow-up. RESULTS: Twenty-two patients were enrolled (CI: n = 11; IOS: n = 11), and one patient in the CI group was lost to follow-up. No statistically significant difference in the V&T score was observed between the CI and IOS groups (4.66 &#xb1; 0.17 vs. 4.65 &#xb1; 0.28; P = 0.93). The operator reported greater nervousness during the CI procedure than during IOS (21.82 &#xb1; 15.69 vs. 8.64 &#xb1; 7.47; P < 0.05). Patients in the CI group reported significantly greater discomfort, including nausea and anxiety, than those in the IOS group (P < 0.05). At the 6-month follow-up, the early implant survival rate was 100% in both groups. No significant differences were found between the groups in MBL (0.09 &#xb1; 0.09 vs. 0.06 &#xb1; 0.10 mm; P = 0.43) or mPII (0.10 &#xb1; 0.12 vs. 0.10 &#xb1; 0.28; P = 0.99). CONCLUSION: IOS and CI achieved comparable short-term clinical outcomes in patients who met the predefined inclusion criteria, including controlled implant number, spacing, and angulation. IOS provided a more favorable experience for both operators and patients. CLINICAL SIGNIFICANCE: In complete-arch implant restorations, intraoral scanning may provide clinical outcomes comparable to those of conventional impressions while improving patient comfort.

Humans

Evaluating Patient Satisfaction and Oral Health Impact Profile-14 (OHIP-14): A Multicenter Crossover Study Comparing Selective Pressure Impression Conventional Dentures with Mucostatic Digital Dentures.

PURPOSE: To compare patient satisfaction and oral health impact between individuals receiving complete dentures made by digital methods and those using conventional techniques. MATERIALS AND METHODS: In this randomized crossover clinical trial, 23 patients aged 40 years and older with completely edentulous arches were enrolled at three treatment centers. Each participant received two sets of complete dentures: one set created using conventional methods (selective pressure impression) and the other through digital techniques (mucostatic digital impression). The order of denture placement was randomized, with each set used for 4 weeks. A trained specialist administered treatments alongside research tools, including a general information questionnaire, a denture satisfaction survey, and the OHIP-14 interview tool. Statistical analysis was conducted using Mann-Whitney U test. RESULTS: Participants with digital dentures reported significantly higher satisfaction regarding treatment duration, comfort, confidence, chewing ability, esthetics, and overall satisfaction compared to those with conventional dentures. There were no significant differences in satisfaction concerning speech and pronunciation. Overall, the oral health impact on quality of life was similar between denture types, but participants indicated improved quality of life while using dentures compared to being edentulous. CONCLUSIONS: Patients with digital dentures exhibited greater satisfaction across various domains compared to those with conventional dentures, despite similar satisfaction levels in speech and pronunciation. The impact on quality of life was comparable between both types, as measured by the OHIP-14.

Humans

Comfort and Usability of Digital Versus Conventional Custom-Fit Mouthguards: A Randomized Clinical Trial.

BACKGROUND/OBJECTIVES: The use of mouthguards protects teeth and the supporting tissues against impacts. Digital impressions and 3D-printed models can reduce manufacturing steps and minimize discomfort. This study evaluated the fit, comfort, and usability of custom-made mouthguards, obtained by conventional and digital workflow, in amateur athletes. MATERIALS AND METHODS: Amateur athletes were recruited for this randomized, double-blind, crossover clinical study. Each participant received two 4-mm-thick custom-fit mouthguards made of ethylene vinyl acetate (EVA) sheets using two protocols: conventional impression using alginate to produce dental stone cast (CMP) and intraoral digital scanning to produce 3D-printed resin models (DMP). Each mouthguard was worn during all training and matches over 3&#x2009;months. The order of mouthguard use was randomly assigned. Patient satisfaction with the impression protocol and mouthguard use, model accuracy, and mouthguard fit were assessed. RESULTS: Overall, 46 participants completed the study. The DMP protocol required less execution time (p&#x2009;=&#x2009;0.023), caused less discomfort (p&#x2009;=&#x2009;0.018), anxiety (p&#x2009;=&#x2009;0.008), nausea (p&#x2009;=&#x2009;0.027), difficulty breathing (p&#x2009;<&#x2009;0.001), and unpleasant taste (p&#x2009;=&#x2009;0.006) compared to the CMP protocol. The pain (p&#x2009;=&#x2009;0.971) perceived by the participants was similar in both impression protocols. The CMP-mouthguards were considered to be better fitting by the majority of participants (p&#x2009;=&#x2009;0.027). Between-group comparisons revealed that DMP-mouthguard caused less discomfort immediately postadaptation (p&#x2009;=&#x2009;0.034), with no significant differences observed at 30 or 90&#x2009;days. CONCLUSIONS: The digital workflow demonstrated to be efficient in the fabrication of mouthguards. Digital impression was more comfortable, requiring less execution time, with more accurate printed models and produced mouthguards with reported comfort and fit levels similar to those manufactured conventionally.

Humans

The use of diode laser and scalpel blade in stage-two dental implant surgery: a comparative study.

OBJECTIVE: The use of lasers in dental implant procedures raises questions regarding the preservation of keratinized tissues and implant outcomes. This study aimed to compare the clinical effects (pain and impression time) and soft tissue healing (keratinization, peri-implant probing, bleeding, and healing) of diode lasers and scalpels used during stage-two dental implant surgery. METHOD AND MATERIALS: A prospective randomized clinical trial with a 1:1 allocation ratio was conducted. The study included 30 patients, each with a single, fully osseointegrated implant. Patients were categorized into two groups. The study group underwent stage-two implant surgery using a 970-nm diode laser. In the control group, implants were exposed using a conventional surgical blade. A comparison between the diode laser and conventional scalpel groups was made based on clinical outcomes (pain and impression time) and soft tissue healing (keratinization, peri-implant probing, bleeding, and healing). Data were analyzed using a paired t test. RESULTS: Pain intensity significantly decreased from immediate postoperative to 7 days in both scalpel (49.87 &#xb1; 6.78, t = 28.48, df = 14, P .001) and diode laser (7.67 &#xb1; 7.58, t = 3.91, df = 14, P = .002) groups. Immediately after surgery, pain scores were significantly higher in the scalpel group compared with the diode laser group (94.53 &#xb1; 4.45 vs 46.93 &#xb1; 5.85, t = 25.076, df = 26.151, P .001). Although pain decreased in both groups by day 7, the scalpel group continued to exhibit significantly greater pain (44.67 &#xb1; 5.96 vs 39.27 &#xb1; 3.73, t = 2.974, df = 23.513, P = .007). Impression time (P = .231) and gingival keratinized tissue (P = .736) did not differ significantly between the scalpel and diode laser approaches. At week 6, the scalpel group exhibited a significantly higher mean peri-implant bleeding index (2.60 &#xb1; 0.507) compared with the laser group (0.07 &#xb1; 0.258, P .001). However, after 12 weeks, no significant difference was observed (1.58 &#xb1; 0.19 vs 1.55 &#xb1; 0.21, P = .748). Laser surgery produced significantly better early wound healing at all intervals (P .001), while intraoperative bleeding was more common with the scalpel technique than with the diode laser (100.0% vs 66.7%, P = .042). CONCLUSION: Compared with the scalpel method, the diode laser method resulted in a significant reduction in pain intensity, improved wound healing, and less peri-implant bleeding during the stage-two dental implant surgery.

Humans

Clinical accuracy and short-term outcomes of intraoral photogrammetry for complete-arch implant rehabilitation: A retrospective multicentre study on 35 patients.

OBJECTIVES: To evaluate the clinical accuracy and short-term outcomes of complete-arch implant-supported fixed dental prostheses (ISFDPs) fabricated using an intraoral photogrammetry (IPG) based digital workflow in completely edentulous patients. METHODS: This multicenter retrospective clinical study included 35 patients rehabilitated with 52 complete-arch ISFDPs (10 FP1, 18 FP2 and 24 FP3 restorations) supported by 221 implants. All definitive prostheses were designed and fabricated using a fully digital workflow initiated by IPG acquisition with the Aoralscan Elite IPG&#xae; (SHINING 3D). The primary outcome was clinical accuracy, assessed at definitive prosthesis delivery through evaluation of passive fit using the Sheffield test and radiographic verification. Secondary outcomes included biologic and prosthetic complications, as well as implant and prosthesis survival rates during the follow-up. RESULTS: Passive fit was achieved in all definitive restorations (100%). Radiographic evaluation confirmed accurate marginal adaptation at the implant-prosthesis interface in all cases. No statistically significant differences in clinical accuracy were observed according to treated arch, number of supporting implants, or prosthetic design (P > .05). During a mean follow-up period of 12.1 &#xb1; 3.5 months, biologic and prosthetic complications were limited and generally minor. Implant survival was 99.5%, and prosthesis survival was 100%. CONCLUSIONS: Within the limitations of this retrospective clinical study, the IPG based workflow demonstrated high clinical accuracy and predictable short-term outcomes for complete-arch implant rehabilitation, consistently enabling passive fit and favorable prosthetic performance. CLINICAL RELEVANCE: IPG may represent a clinically reliable and predictable approach for complete-arch digital implant impression acquisition. The high rates of passive fit, together with the low incidence of biologic and prosthetic complications observed in this multicenter clinical study, support the use of IPG based workflows for the fabrication of complete-arch ISFDPs.

Humans

Clinical Performance of Bulk-Fill Versus Incremental Composite Placement Approaches in Vital Posterior Teeth: A 24&#x2009;Months Randomized Controlled Trial.

BACKGROUND: Composite resin placement technique may influence marginal integrity, polymerization stress distribution, and long-term clinical performance of posterior restorations. This randomized controlled clinical trial evaluated the 24-month clinical performance of four different placement techniques in Class I posterior composite restorations. METHODS: Fifty patients aged 20-35&#x2009;years presenting with four occlusal carious lesions each were enrolled, resulting in 200 restorations. Cavities (4-5&#x2009;mm depth) were prepared according to caries extension. Restorations were randomly allocated into four equal groups (n&#x2009;=&#x2009;50) according to placement technique: stamp technique, snowplow technique, modified incremental "pizza" technique, and bulk-fill technique. All materials were applied following manufacturers' instructions. Clinical evaluation was performed at baseline and after 6, 12, and 24&#x2009;months using FDI criteria. Functional (fracture/retention, marginal adaptation), esthetic (marginal staining, anatomical form), and biological (postoperative sensitivity, secondary caries) properties were assessed by two calibrated evaluators. Statistical analysis was performed at a significance level of &#x3b1;&#x2009;=&#x2009;0.05. RESULTS: Thirty-eight patients with a total of 152 restorations were evaluated at the end of the 24&#x2009;months in line with FDI at the end of the study with 76% recall rates. No statistically significant differences were observed among groups regarding fracture/retention or secondary caries (p&#x2009;>&#x2009;0.05). Marginal adaptation and marginal staining demonstrated minor deterioration over time across all groups, with statistically significant intergroup differences found (p&#x2009;<&#x2009;0.05). Postoperative sensitivity was minimal and transient in all groups with no significant difference (p&#x2009;=&#x2009;0.181). CONCLUSIONS: Within the limitations of this 24-month follow-up, the four placement techniques demonstrated comparable clinical performance in Class I posterior composite restorations. Selection of technique may therefore be guided by clinical preference and procedural efficiency rather than differences in short-term clinical outcomes. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT07415317.

Humans

Indications, Techniques and Complications Associated With Pterygoid Implants: A Systematic Review and Meta-Analysis.

BACKGROUND AND OBJECTIVES: Pterygoid implants represent a graftless option for rehabilitation of patients with posterior maxillary atrophy, engaging the dense cortical bone of the pterygomaxillary complex. Despite clinical growth, a comprehensive synthesis of indications, surgical techniques, and complications is lacking. This review evaluated the prevalence of complications, implant survival rates, and marginal bone loss (MBL) associated with pterygoid implant placement. METHODS: The reporting of this review follows PRISMA 2020 guidelines. Six electronic databases (PubMed, Ovid, Scopus, WoS, CENTRAL, and Dentistry & Oral Sciences Source) were searched from 1 January 2020 to 31 December 2025. Included criteria comprised randomized and non-randomized clinical studies reporting outcomes of pterygoid implants (&#x2265;&#x2009;13&#x2009;mm) in adult patients with posterior maxillary atrophy (minimum 10 implants). Risk of bias was assessed using JBI critical appraisal checklists. Proportions were pooled using the Freeman-Tukey double arcsine transformation under a random-effects model. Certainty of evidence was assessed using GRADE. RESULTS: Seventeen studies reporting 846 patients and 1915 pterygoid implants were included. The pooled survival rate was 97.9% (95% CI: 97.1%-98.6%; I2&#x2009;=&#x2009;0%; 14 studies) and the overall failure rate was 2.1% (95% CI: 1.4%-3.0%). Early failure rate was 0.9% (95% CI: 0.0%-3.0%; I2&#x2009;=&#x2009;59.5%). Late failure and MBL were summarized narratively. Certainty of evidence was low to very low. CONCLUSIONS: Pterygoid implants demonstrate excellent survival (97.9%) and low failure rates (2.1%), primarily early, supporting their reliability as a graftless solution for posterior maxillary atrophy. Complications appear infrequent though heterogeneously reported. Low evidence certainty necessitates prospective studies with standardized outcome reporting.

Humans

Effectiveness of different anaesthetic techniques, agents and adjunctive interventions in handling pain during dental treatment of MIH-affected teeth: a systematic review.

BACKGROUND: Molar incisor hypomineralisation (MIH) is frequently associated with hypersensitivity, dental anxiety and reduced efficacy of local anaesthesia, complicating pain control during dental treatment in children. AIM: To evaluate, based exclusively on randomised controlled trials (RCTs), the effectiveness of different local anaesthetic techniques, agents and adjunctive interventions in reducing pain during dental treatment of MIH-affected teeth in children. METHODS: A systematic review was conducted following PRISMA 2020 guidelines and registered in PROSPERO (CRD420251150485). MEDLINE, Cochrane Central, ScienceDirect, SCOPUS, EBSCO, and LILACS were searched up to September 2025. Eligible studies were RCTs involving children and adolescents (6 - 18&#xa0;years-of-age) with MIH, assessing pain outcomes during dental procedures. Risk of bias was assessed using the Cochrane RoB 2 tool, and certainty of evidence was evaluated using the GRADE approach. RESULTS: Eight RCTs were included. Low-certainty evidence suggested that intraosseous anaesthesia and 4% articaine may reduce intra-operative pain compared with conventional techniques or 2% lidocaine. Adjunctive cryotherapy and pre-emptive ibuprofen showed potential benefits, but evidence was of very low certainty and limited to single trials. Findings for photobiomodulation were inconsistent across studies. Most trials were judged to be at high risk of bias, primarily due to lack of blinding and reliance on subjective pain outcomes. CONCLUSION: Current evidence supporting specific pain management strategies for MIH-affected teeth is limited and of low certainty. Whilst 4% articaine and intraosseous anaesthesia appear promising, well-designed, adequately powered RCTs with standardised pain outcomes are required to inform robust clinical recommendations.

Local anaesthesia

Marginal fit and five-year outcomes of posterior monolithic zirconia restorations: A randomized paired and observational clinical study.

OBJECTIVES: The aim of this study was to evaluate the marginal fit and five-year clinical performance of posterior 5 mol% yttria-partially stabilized zirconia restorations. A randomized paired comparison with lithium disilicate crowns was performed for marginal fit. METHODS: A total of 65 posterior restorations were placed in 38 patients, including 32 zirconia crowns, 17 lithium disilicate crowns, and 16 zirconia partial coverage restorations. In the randomized paired comparison, 17 patients received one lithium disilicate crown and one zirconia crown. Additional zirconia crowns (n=15) and zirconia partial coverage restorations (n=16) were included in a prospective observational cohort. The primary outcome was marginal fit within the randomized cohort. Marginal and internal fit were assessed using the replica technique. Marginal and internal gap values were compared using the Wilcoxon signed-rank test; clinical outcomes were analyzed descriptively, and Kaplan-Meier estimates were calculated for survival and complication-free survival. Clinical performance was assessed using CDA criteria, periodontal parameters, complication recording, and patient-reported outcomes. Clinical examinations were performed at baseline and at 12, 24, 36, 48, and 60 months. RESULTS: Mean marginal gap values at the crown margin were 46 &#xb1;33 &#xb5;m for lithium disilicate crowns and 50 &#xb1;32 &#xb5;m for zirconia crowns (p>0.05). No restoration required replacement, resulting in 100% restoration survival after a median follow-up of 60 months (range: 57-64 months). Most complications were biological or functional, including endodontic, periodontal, occlusal, and proximal-contact-related events. One zirconia partial coverage restoration exhibited a small ceramic fracture managed by polishing. The Kaplan-Meier probability of complication-free survival was 76.4% for zirconia crowns, 66.7% for lithium disilicate crowns, and 87.5% for zirconia partial coverage restorations. CONCLUSIONS: In the randomized paired comparison, 5 mol% yttria-partially stabilized zirconia crowns showed marginal gap values similar to lithium disilicate crowns. All restorations remained in situ during the observation period. Lower complication-free survival was mainly related to biological and functional events and should be interpreted separately from restoration survival. CLINICAL SIGNIFICANCE: Clinical evidence for posterior 5 mol% yttria-partially stabilized zirconia restorations remains limited. This study provides mid-term clinical data on crowns and partial coverage restorations. In the randomized full-crown comparison, marginal fit was similar to that of lithium disilicate crowns, supporting the clinical consideration of monolithic zirconia restorations for posterior teeth.

Humans

Comparison of conventional and micro-surgical techniques for gingival recession using collagen matrix: Randomised controlled split-mouth clinical trial.

BACKGROUND: The present study aimed to determine the effectiveness of the microsurgical approach in treating gingival recession with collagen matrix by comparing it with Conventional surgery in terms of clinical and patient-centered outcomes. METHODS: A total of 29 patients with bilateral gingival recession in the maxillary canine and/or premolar region were selected. After randomisation, bilateral recession sites were grouped into the test group (Microsurgery under 3.5 X magnification) and the control group (Conventional surgery). All the clinical and patient-reported parameters were recorded at baseline, 1, 3 and 6 months. RESULTS: Both groups showed statistically significant differences in terms of reduction in gingival recession height (GRH), gingival recession width (GRW), clinical attachment level gain (CAL gain), increase in keratinized tissue thickness (KTT) and keratinized tissue width (KTW) after 6 months. But intergroup comparison showed no significant difference in terms of clinical parameters. The only significant difference was noted in terms of patient-centred parameters (Patient satisfactory score, Hypersensitivity score, Root aesthetic scores), which favoured the microsurgical group. CONCLUSIONS: Both groups demonstrated comparable clinical improvement; However, Patient-centred parameters were significantly better with the Microsurgical approach. Selection of the surgical approach should balance patient needs with practical considerations like cost, time, and clinician proficiency.

Adult

Double-Axis Maxillary Skeletal Expander Suggests Higher Expansion Efficiency in Early Activation: A Finite Element Analysis.

INTRODUCTION: Conventional single-axis maxillary skeletal expanders (MSE) have some drawbacks, such as limited control over maxillary expansion and possible asymmetric expansion between the anterior nasal spine (ANS) and posterior nasal spine (PNS). This report introduces a double-axis maxillary skeletal expander (DAMSE) concept to overcome these drawbacks and enhance the efficiency of maxillary skeletal expansion. MATERIALS AND METHODS: Five different DAMSE designs were compared with a conventional single-axis MSE. Finite element analysis was performed to analyse their expansion efficiency, stress magnitude and distribution occurring in a simplified bone model. RESULTS: DAMSE outperformed the single-axis MSE and provided better control over ANS and PNS expansion. During early activation, the highest expansion efficiency (31.7%) was achieved by DAMSE Model V, 13% more efficient than the single-axis MSE. This efficiency was increased to 100.8% by combining the DAMSE Model V with midpalatal suture surgery. However, with the simplified bone model, the current study could not demonstrate that DAMSE can resolve the issue of asymmetric expansion between ANS and PNS. CONCLUSIONS: An appropriately designed DAMSE can be a promising tool for maxillary expansion treatment. DAMSE offers more efficient treatment than the conventional single-axis MSE while maintaining similar levels of patient comfort and invasiveness.

Finite Element Analysis

Effectiveness of high-power laser use in the removal of esthetic restorations: a systematic review.

This systematic review aimed to evaluate the effectiveness of high-power lasers in the removal of esthetic restorations compared with conventional methods. The review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and registered in PROSPERO (registration number: CRD420251055736). A comprehensive electronic search was performed in MEDLINE, Scopus, Embase, Web of Science, and the Cochrane Library. Study selection, data extraction, and methodological quality assessment were independently performed by four reviewers using QUIN tool for in vitro studies. A total of 2.384 records were identified, of which 19 in vitro studies conducted on extracted human permanent teeth met the eligibility criteria and were included in the qualitative synthesis. The included studies evaluated different high-power laser systems, predominantly Er: YAG and Er, Cr: YSGG lasers, as well as CO&#x2082; lasers. Five studies were classified as high quality, whereas the remaining fourteen studies were classified as moderate quality. Available laboratory evidence suggests that laser-assisted techniques may represent a potential alternative approach for removing esthetic restorations, with advantages including conservative tissue removal, reduced damage to underlying tooth structures, and intrapulpal temperature increases within acceptable limits. The Er: YAG laser was the most frequently investigated system, with power settings ranging from 1.5 to 5.9&#xa0;W, showing particularly favorable laboratorial performance in the removal of lithium disilicate restorations, especially in thinner substrates. Within the limitations of the available evidence, high-power lasers appear to be a promising and minimally invasive alternative to conventional methods for the removal of esthetic restorations. However, the predominance of in vitro studies highlights the need for well-designed clinical trials to confirm these findings and support their clinical application.

Humans

Flap Versus Tunneling for Horizontal Ridge Augmentation With FDBA and i-PRF: A Randomized Controlled Clinical Trial.

AIM: This study evaluated the efficacy of conventional flap and tunneling techniques for horizontal alveolar ridge augmentation using freeze-dried bone allograft (FDBA) particles combined with injectable platelet-rich fibrin (i-PRF). MATERIALS AND METHODS: Forty-five patients were randomly allocated to one of three groups (n&#x2009;=&#x2009;15 each): conventional flap (CF), tunneling with membrane (TM), or tunneling without membrane (TnM). Preoperative ridge width was measured via cone beam computed tomography (CBCT). All augmentation procedures incorporated FDBA and i-PRF; an absorbable collagen membrane was applied in the CF and TM groups. Follow-up assessments, including CBCT imaging and histomorphometric analysis, were conducted 6&#x2009;months postoperatively. For normally distributed data, ANOVA with Tukey's post hoc test and paired samples t-test were applied. Non-normally distributed data were analyzed using Kruskal-Wallis, Mann-Whitney U, and Wilcoxon signed-rank tests. RESULTS: Statistical analysis was performed on 43 patients. All groups demonstrated an increase in ridge width after 6&#x2009;months. At the 2&#x2009;mm level, the mean width gain was 1.28&#x2009;mm (95% CI: 0.17 to 2.40) in the TM group, 2.85&#x2009;mm (95% CI: 1.80 to 3.89) in the TnM group, and 1.95&#x2009;mm (95% CI: 1.07 to 2.83) in the CF group. However, statistical analysis revealed no significant intergroup variation (p&#x2009;>&#x2009;0.05). Histomorphometric assessments similarly demonstrated comparable outcomes across all groups, with no statistically significant differences observed (p&#x2009;>&#x2009;0.05). CONCLUSION: Within the limitations of this study, the tunneling technique, regardless of membrane use, appears to be a clinically viable alternative to the conventional flap method for horizontal alveolar ridge augmentation. However, further studies with longer follow-up periods are required to substantiate these findings. TRIAL REGISTRATION: irct.behdasht.gov.ir identifier: IRCT 20101204005305N21.

Humans

Prevalence and pattern of psychological symptoms in form of dental fear and anxiety in children and adolescents with traumatic dental injuries: a systematic review.

BACKGROUND/AIMS: This systematic review aimed to evaluate the level and pattern of dental fear and anxiety (DFA) amongst children and adolescents with traumatic dental injuries (TDI) and, where available, to compare these outcomes with non-traumatised controls. METHODS: An a priori protocol was developed and registered in PROSPERO (CRD420261329946). A comprehensive literature search was conducted in PubMed, EMBASE, Web of Science, and Scopus on 3 March 2026, with additional grey literature, citation, and reference searching. No language or time restrictions were applied. Observational clinical studies assessing DFA in individuals with TDI using validated tools were included. Two reviewers independently screened studies, extracted data, and assessed risk of bias using the Joanna Briggs Institute checklist. Certainty of evidence was evaluated using the GRADE approach. RESULTS: A total of 2885 records were identified, of which 4 cross-sectional studies met the inclusion criteria after screening. Studies were conducted in Croatia and Kosovo and included paediatric populations. Sample sizes ranged from 147 to 505 participants. Different validated scales (CFSS-DS, CDAS, S-DAI) were used to assess DFA. Overall, children with TDI demonstrated predominantly low levels of dental fear and anxiety across assessment tools. However, findings were inconsistent, with some studies reporting lower or similar anxiety levels in TDI patients compared to controls. Risk of bias was moderate or high in three of the four studies, and the overall certainty of evidence was rated as low to very low due to methodological limitations, heterogeneity, and imprecision. CONCLUSION: The limited available evidence suggests that children and adolescents with TDI do not consistently present with higher levels of dental fear and anxiety than non-traumatised controls. These findings indicate that TDI does not inherently cause DFA, underscoring the critical role of empathetic behaviour support in mitigating post-traumatic dental fear. However, the evidence is based on a small number of regionally concentrated cross-sectional studies with low to very low certainty. Future prospective studies using standardised TDI classifications, validated DFA instruments, and clearly defined assessment time points are needed.

Dental anxiety

Socioeconomic differences in the effectiveness of oral health programs for dental caries prevention in Europe: A systematic review and meta-analysis.

AIM: The meta-analysis systematically summarized evidence on how socioeconomic status (SES), access to dental care, and oral health programs (OHP) affect caries prevalence and severity among children and adults in Europe. METHODS: Four electronic databases (PubMed, Scopus, Cochrane Library and Embase) were systematically screened from 1947-2026, supplemented by cross-referencing and manual searches, without language restrictions. Study selection, data extraction and quality assessment were done in duplicate. Methodological quality was assessed using the NHLBI Study Quality Assessment Tools according to study design. Certainty of evidence was graded using GRADE Profiler 3.6. Mean differences (MD) were calculated for changes in DMFT, and odds ratios (OR) for the presence of dental caries in individuals using fixed-or random-effects models. RESULTS: Electronic searching identified 1800 articles; 23 studies were included in the review (>169,000 participants) and 14 in the meta-analyses (>88,000). Nine studies evaluated the effectiveness of OHP stratified by SES, and ten examined OHP in low-SES populations. Among low-SES individuals, participation in OHP was associated with a significantly lower increase in DMFT (MD[95% CI]=-0.63[-0.94;-0.31];very low certainty) and significantly lower odds of having dental caries (OR[95% CI]=0.61[0.52;0.73];very low) compared with non-participation. Among program participants, individuals with low SES showed a significantly greater increase in DMFT than those with high SES (MD[95% CI]=0.79[0.30;1.21];very low) and had significantly higher odds of having dental caries (OR[95% CI]= 2.88[1.97;4.22];very low). CONCLUSION: Participation in OHP may be associated with reducing dental caries in European populations, but benefits are unequally distributed and increase with higher SES. However, this conclusion is based on a limited number of well-conducted trials.

Humans

Nutrition and Diet-Related Training and Curriculum in the US Predoctoral Dental Programs.

PURPOSE: Nutrition and diet are vital for oral and systemic health. It is unclear how well US predoctoral dental programs prepare students in nutrition screening and counseling. This study analyzed US dental school curricula on these topics. METHODS: A cross-sectional online survey was sent to the publicly available email addresses of 67 of 72 academic dental deans at US Commission on Dental Accreditation-accredited dental schools. Items assessed availability, modes and hours of instruction, curricular topics, clinical integration, and instructors. Descriptive statistics summarized responses. RESULTS: A total of 21 academic deans responded, for an overall response rate of 29%. Most (85%) of responding academic dental deans reported that nutrition and diet education was mandatory, with none treating it as optional. Of these schools, 83% offered both classroom and clinical training, while 17% provided only didactic teaching. Didactic hours varied; 42% reported 10 or fewer hours. Foundational nutrition topics were common, although dietary guidelines such as MyPlate were reported less often (66%). Oral health-related nutrition content was broadly covered, with all respondents reporting instruction related to caries, erosion, periodontal disease, and oral dysfunction. Counseling content was less consistent, particularly public health nutrition (67%) and the impact of oral dysfunction on diet and nutrition (72%). CONCLUSION(S): Most responding academic dental deans report including nutrition and diet education in their curricula. However, it remains uncertain whether these topics are incorporated at schools that did not participate in the survey. Variability in curricular time, counseling, and teaching highlights the need for clearer competencies and more clinical training. Improving this could better prepare future dentists for common dietary risks affecting oral and systemic health.

dental caries

Clinical performance evaluation of single-shade versus multi-shade composite resins in non-carious cervical lesions: a 36-month randomized clinical trial.

BACKGROUND: Composite resins are widely used as the material of choice for definitive restorations due to their ability to integrate functional and aesthetic aspects in dental rehabilitation. Recently, one-shade composite resins have been introduced to simplify the clinical workflow. OBJECTIVES: This study aimed to compare the clinical performance of a "chameleon effect" composite resin with that of a multi-shade composite resin in non-carious cervical lesions after 36 months of follow-up. METHODS: This study was a randomized, controlled, double-blind clinical trial with an equivalence design using a split-mouth approach. The sample consisted of 60 patients presenting at least two non-carious cervical lesions, totaling 120 restorations. Restorations were performed using two materials from the same commercial brand: Vittra Unique (one-shade group) and Vittra APS (multi-shade group). The clinical performance of the restorations was longitudinally evaluated according to the FDI criteria. Survival analysis was performed using Kaplan-Meier curves and the log-rank test, while other clinical parameters were compared using the chi-square test (&#x3b1; = 0.05). RESULTS: At baseline, no statistically significant differences were observed between the groups regarding the evaluated biological, functional, and aesthetic parameters (p > 0.05). Both materials demonstrated clinically acceptable performance according to the FDI criteria, with no significant differences between them. CONCLUSIONS: After 36 months, no significant differences were observed between the one-shade and the multi-shade composite resins in the restoration of non-carious cervical lesions. CLINICAL SIGNIFICANCE: This 36-month randomized clinical trial demonstrates that single-shade composite resins achieve structural durability and aesthetic integration equivalent to traditional multi-shade layering when restoring non-carious cervical lesions. This evidence validates a simplified, single-shade restorative workflow, significantly reducing chairside time and operator-dependent variables without compromising the clinical longevity.

Humans

Artificial intelligence for dental caries detection: An umbrella review.

Artificial intelligence (AI) has been proposed as a tool to improve dental caries detection across imaging modalities; however, its clinical value remains uncertain. This umbrella review aimed to synthesize and critically appraise systematic reviews evaluating AI for caries detection and diagnosis. An umbrella review was conducted following PRIOR guidance (PROSPERO CRD420261340728). Searches were performed in MEDLINE, Embase, Scopus, Web of Science, and Google Scholar up to 15 March 2026. Methodological quality was assessed using AMSTAR 2, and overlap of primary studies was quantified using the corrected covered area (CCA). Seventeen systematic reviews were included, of which five reported diagnostic test accuracy meta-analyses using bivariate or HSROC models. Across these meta-analyses, pooled sensitivity ranged from 0.76 to 0.94 and specificity from 0.85 to 0.91. Most systems were based on deep learning models applied to bitewing radiographs and intraoral photographs. However, substantial heterogeneity was observed in imaging modalities, lesion thresholds, analytical tasks, and evaluation metrics. In addition, a high degree of overlap across reviews and recurrent methodological limitations, including reliance on retrospective datasets, limited external validation, and inconsistent reporting, substantially weaken the reliability of the evidence. Although AI models demonstrate high diagnostic performance under experimental conditions, current evidence does not support their use as stand-alone diagnostic tools. Their clinical applicability remains limited, and implementation should be restricted to decision-support contexts until robust prospective validation demonstrates meaningful impact on clinical decision-making and patient outcomes.

Dental Caries