Search PubMedSearch

SEARCH · Search PubMed

Results for “CT-guided Intervention”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

873 recordsLinked to original sources

Robotic Needle Insertion for CT-guided Percutaneous Biopsy of Thoracoabdominal Lesions: A Prospective Multicenter Randomized Trial.

Purpose To compare safety and feasibility between a novel CT-guided robotic system and the conventional freehand technique for puncture biopsy of thoracoabdominal lesions. Materials and Methods In this prospective multicenter randomized trial, individuals with suspected lesions were enrolled between July 2023 and April 2024 across three university teaching hospitals and randomized to the robot-assisted group (n = 82) or the freehand group (n = 83). Procedure outcomes included the technical success rate, targeting error, number of CT scans and needle adjustments, puncture time, and complications. Descriptive and inferential statistics were calculated. Results A total of 165 participants (mean age, 60 years &#xb1; 10 [SD]; 83 male) were included. Compared with the freehand group, the robot-assisted group demonstrated a higher technical success rate (97.56% [80 of 82] vs 62.65% [52 of 83], P < .001), lower targeting error (mean Euclidean deviation: 1.7 mm &#xb1; 1.1 vs 4.5 mm &#xb1; 3.9, P < .001), and fewer CT scans (mean, 4.3 &#xb1; 1.9 vs 5.2 &#xb1; 2.3; P = .002) and needle adjustments (mean, 0.7 &#xb1; 0.7 vs 1.6 &#xb1; 1.6; P = .003). Despite differences in geometric precision, both groups achieved 100% (82 of 82 and 83 of 83) diagnostic yield. The median puncture time was comparable between groups (5.5 minutes &#xb1; 4.3 vs 4.8 minutes &#xb1; 7.0, P = .50). During lung biopsies, the robot-assisted approach yielded fewer complications compared with the freehand approach (4.88% [four of 82] vs 16.87% [14 of 83], P = .014). Conclusion Compared with the freehand approach, robot-assisted biopsy yielded greater precision and reduced adjustments and complications while demonstrating noninferior diagnostic efficacy and comparable duration. Keywords: Robotic Needle Insertion, Biopsy, Thoracoabdominal Lesions, Robot-assisted Biopsy, CT-guided Intervention, Percutaneous Needle Biopsy, Randomized Controlled Trial, Algorithm Development, CT, Clinical Testing, Interventional-Body, Biopsy/Needle Aspiration, Percutaneous, Thorax, Abdomen/GI, Liver, Lung, Kidney &#xa9;RSNA, 2026.

Humans

Ketamine Plus Midazolam versus Fentanyl Plus Midazolam for Sedation and Analgesia during Image-guided Procedures in Interventional Radiology: Randomized Clinical Trial.

Background Opioid-benzodiazepine regimens remain common for radiologist-administered procedural sedation despite respiratory and analgesic effectiveness concerns. Purpose To compare intraprocedural pain and patient-reported experience between ketamine/midazolam and fentanyl/midazolam during image-guided procedural sedation. Materials and Methods This randomized clinical trial was conducted at a single academic center between June 2025 and February 2026. Adults undergoing image-guided lung or bone biopsy or abscess drainage were randomized to fentanyl/midazolam or ketamine/midazolam administered by interventional radiologists. Procedures were performed using US, CT, CT fluoroscopy, or combined CT and US guidance. The primary outcome was maximum intraprocedural pain (0-10 on the Numeric Rating Scale). Secondary outcomes included sedation depth, physiologic parameters, oxygen desaturation, patient-reported experience assessed using a modified Heidelberg questionnaire, and complications. Results Among 264 randomized procedures (132 procedures per group) in 260 participants (median age, 68 years [IQR, 61-75 years]; 135 [52%] female), ketamine/midazolam resulted in lower maximum intraprocedural pain than fentanyl/midazolam (mean difference, -1.4 points [95% CI: -2.0, -0.8]; P < .001). Pain scores greater than 4 occurred less frequently with ketamine/midazolam (2.3% vs 17%; absolute difference, 14 percentage points [95% CI: 8, 21]; P < .001). Ketamine/midazolam was associated with higher nadir oxygen saturation (mean difference, +1.4% [95% CI: 0.6, 2.2]; P = .001) and fewer oxygen desaturation events below 90% (three [2.3%] vs 13 [9.8%]; absolute difference, 7.6 percentage points [95% CI: 1.9, 13.3]; P = .02). Ketamine/midazolam produced deeper sedation and higher intraprocedural systolic blood pressure. Hallucinations occurred more frequently with ketamine/midazolam (15 [11.4%] vs five [3.8%]; absolute difference, 7.6 percentage points [95% CI: 1.3, 13.9]; P = .03), though overall procedural comfort, reduced recall, and perceived adequacy of sedation were improved. Procedure-related and sedation-related complications did not differ between groups. Conclusion Radiologist-administered ketamine/midazolam during image-guided procedural sedation improved analgesia and patient-reported experience with fewer hypoxemic events and no increase in complications compared with fentanyl/midazolam. Clinical trial registration no. NCT07040163

Aged

PCa Detection in PI-RADS 4 and 5 Lesions: Comparison of [68Ga]Ga-PSMA-11 PET/CT-Guided Robot-Assisted Biopsy Versus mpMRI Cognitive-Fusion TRUS-Guided Prostate Biopsy.

Lesions with a Prostate Imaging-Reporting and Data System (PI-RADS) score of 4 or greater on multiparametric MRI (mpMRI) indicate a high likelihood of prostate cancer (PCa), and guidelines recommend a targeted biopsy. We aimed to compare the diagnostic performance of robotic arm-assisted [68Ga]Ga-PSMA-11 PET/CT-guided prostate biopsy (PGPB) with mpMRI-directed cognitive-fusion transrectal ultrasound-guided biopsy (MCFB) in biopsy-na&#xef;ve men with clinical findings suggestive of PCa. Methods: This prospective, single-center, randomized clinical trial (NCT05137561) enrolled biopsy-na&#xef;ve men age 50-90 y with elevated levels of prostate-specific antigen (&#x2265;4 ng/mL) and abnormal digital rectal examination findings. All participants underwent mpMRI, and those with a PI-RADS score of 4 or greater were randomized into 2 arms. In arm 1, participants underwent PGPB for a [68Ga]Ga-PSMA-avid lesion, and participants in arm 2 underwent MCFB. Participants in arm 1 with PET-negative findings subsequently underwent MCFB, and participants with negative biopsy results underwent PET and PGPB. The primary outcome was the detection of PCa. Secondary outcomes included complication rates and participant-reported pain. Result: Of the 267 participants enrolled, 81.3% (217) had lesions with a PI-RADS score of 4 or greater and were randomized to either PGPB (n = 112) or MCFB (n = 105). PCa was detected in 97.1% of participants (101/104) in arm 1 and 81.0% (85/105) in arm 2 (P < 0.05). PGPB showed higher diagnostic accuracy for PI-RADS 5 lesions (100% vs. 95.1%, P = 0.09). Major complications were observed in arm 2 only (n = 5). Arm 1 had significantly fewer complications (10.8% vs. 51.4%, P < 0.01), a lower median visual analog scale score for pain (3 vs. 5), and shorter procedure times. The core positivity rate was higher in arm 1 (60% &#xb1; 20%), despite obtaining fewer cores. Conclusion: [68Ga]Ga-PSMA-11 PGPB demonstrated higher diagnostic performance, fewer complications, and better tolerability compared with MCFB. This approach enables integrated diagnosis and staging, offering a promising alternative for efficient, safe, and accurate evaluation of prostate cancer.

Humans

Higher Rates of PASS and SCB After Arthroscopic Subspine Decompression Are Associated With a Positive Diagnostic AIIS Injection: A Propensity Score-Matched Cohort Study.

BACKGROUND: Hip arthroscopy effectively treats femoroacetabular impingement syndrome (FAIS), but persistent pain may be related to concomitant extra-articular pathology such as subspine impingement syndrome (SSI). Standard diagnosis of SSI often relies on 3-dimensional computed tomography (3D-CT) morphology (Hetsroni type II/III), although this morphology is common in individuals who are asymptomatic and correlates poorly with symptoms. PURPOSE: To compare minimum 2-year clinical outcomes after arthroscopic subspine decompression in patients with concurrent FAIS and type II/III anterior inferior iliac spine (AIIS) morphology, stratified by diagnostic method: 3D-CT morphology alone versus 3D-CT morphology plus a positive ultrasound-guided diagnostic injection. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: This study included patients aged 18 to 55 years with type II/III AIIS morphology who underwent primary hip arthroscopy for FAIS and SSI between January 2021 and November 2023 and had minimum 2-year follow-up. Patients diagnosed by CT morphology alone (CT classification group) were propensity score matched 1:1 to patients with a positive ultrasound-guided AIIS injection (injection group), with 57 patients per group. Matching variables were age, sex, body mass index, lateral center-edge angle, alpha angle, T&#xf6;nnis grade, and Beighton score. All patients underwent arthroscopic subspine decompression. Patient-reported outcomes and rates of achieving the minimal clinically important difference, Patient Acceptable Symptom State (PASS), and substantial clinical benefit (SCB) were compared. RESULTS: Preoperative patient-reported outcome scores were similar between groups (all P > .05). At minimum 2-year follow-up, the injection group had significantly better scores on the modified Harris Hip Score (90.8 vs 84.2), Hip Outcome Score-Activities of Daily Living (88.4 vs 82.4), Hip Outcome Score-Sports Subscale (71.9 vs 64.1), 12-item International Hip Outcome Tool (83.9 vs 76.1), and visual analog scale for pain (1.2 vs 2.0) (all P < .001). Minimal clinically important difference rates were high in both groups, with higher rates in the injection group for modified Harris Hip Score (93% vs 77%; P = .033) and Hip Outcome Score-Activities of Daily Living (91% vs 75%; P = .042). PASS and SCB rates were significantly higher in the injection group across all patient-reported outcome measures (all P < .05). Revision and complication rates were low and did not differ significantly between groups. CONCLUSION: Both groups improved significantly after arthroscopic subspine decompression. However, patients with a positive ultrasound-guided diagnostic AIIS injection achieved higher PASS and SCB rates than those selected by CT morphology alone, suggesting that injection-confirmed SSI may improve patient selection for subspine decompression.

Humans

Pelvic lymph node dissection in prostate cancer: current evidence, controversies, and future directions.

BACKGROUND: Pelvic lymph node dissection (PLND) remains controversial in the management of prostate cancer. Although it provides the most accurate pathological staging, its therapeutic value beyond staging has long been debated due to conflicting evidence and concerns regarding procedure-related morbidity. OBJECTIVE: To critically evaluate the contemporary role of PLND, particularly extended pelvic lymph node dissection (ePLND), in prostate cancer management in the context of modern imaging, risk stratification tools, and evolving oncologic endpoints. EVIDENCE ACQUISITION: A narrative review of recent literature was conducted, focusing on high-level evidence including randomized trials, observational studies, and contemporary guideline recommendations addressing the indications, extent, oncologic outcomes, and complications of PLND. EVIDENCE SYNTHESIS: Recent randomized and observational studies suggest that ePLND improves nodal staging accuracy and may be associated with modest improvements in metastasis-free survival (MFS) in selected patients with intermediate- and high-risk prostate cancer, although the absolute benefit remains limited and causality is not definitively established. Advances in molecular imaging, particularly prostate-specific membrane antigen (PSMA) PET/CT, together with multiparametric MRI, validated nomograms, and emerging genomic classifiers, now allow more precise identification of patients most likely to benefit from ePLND. The integration of these tools supports a more individualized surgical strategy, including image-guided and sentinel lymph node approaches designed to maximize staging accuracy while minimizing unnecessary dissection. CONCLUSIONS: In the contemporary PSMA imaging era, ePLND continues to play an important role in nodal staging and may contribute to improved oncologic outcomes in carefully selected patients.

Humans

Wedge tarsectomy using patient specific instrumentation for complex multiplanar foot deformity Reconstruction: A prospective case series.

BACKGROUND: Bony correction in complex cavovarus deformities is often multiplanar. We examine our results following wedge tarsectomy (WT) using patient-specific instrumentation (PSI). METHODS: This single-centre, prospective case series evaluated noncorrectable cavovarus feet undergoing PSI-guided WT. Accuracy of PSI guides/plans, operative duration, and adjunctive procedures were recorded. Weightbearing CT (WBCT) measurements and PROM scores were recorded preoperatively and postoperatively, with 1 year follow-up. Data was then statistically analysed. RESULTS: Eleven patients were included. Planned correction was achieved (two required minor intraoperative adjustments to the initial osteotomy and nine required adjunctive procedures). Mean operative time was 135&#x202f;min. Postoperative improvements were significant radiologically and in MOxFW walking distance. All fused by 3 months, with no significant complications. CONCLUSION: PSI-guided wedge tarsectomy safely achieves predictable multiplanar corrections. Our unit's experience has been excellent, with improvement in patients' walking, particularly with larger deformity corrections. LEVEL OF EVIDENCE: Level IV, prospective case series.

Humans

Effect of demographic characteristics on the outcome of prostate cancer salvage radiotherapy: Analysis from a randomized controlled trial.

BACKGROUND: This study investigated the impact of advanced molecular imaging, race, socioeconomic status, and metabolic dysregulation on the outcome of salvage radiotherapy (sRT) for prostate cancer recurrence in a clinical trial setting. METHODS: The authors randomized post-prostatectomy men with detectable prostate-specific antigen to sRT guided by conventional imaging (arm A) or 18F-fluciclovine-positron emission tomography/computed tomography (arm B) and followed them up for up to 48 months to determine failure-free survival (FFS). The authors computed socioeconomic status (SES) and allostatic load (AL) scores to quantify socioeconomic status and level of metabolic dysregulation. They stratified patients by race as African American men (AAM) versus men of other races (MOR) and compared FFS between them using the z-test. RESULTS: Eighty-one (AAM&#xa0;=&#xa0;29, MOR&#xa0;=&#xa0;52) and 76 (AAM&#xa0;=&#xa0;26, MOR&#xa0;=&#xa0;50) men completed per-protocol sRT in arms A and B, respectively. Across study arms, AAM showed a higher FFS rate than MOR (72.8% [95% CI, 53.8%-85.0%] vs. 58.7% [95% CI, 46.6%-68.9%]; p&#xa0;=&#xa0;.002). In arm A, FFS rate was better for AAM than MOR, (64.0% [95% CI, 34.4%-82.9%] vs. 45.3% [95% CI, 28.8%-60.4%]; p&#xa0;=&#xa0;.008). In arm B, FFS improved for both groups but less so for AAM, (81.5% [95% CI, 57.2%-92.7%] vs. 73.0% [95% CI, 56.3%-84.1%]; p&#xa0;=&#xa0;.131). The authors found lower SES scores and higher AL scores for AAM in both study arms than MOR. CONCLUSION: Despite lower socioeconomic status and higher burden of metabolic dysregulation, in a clinical trial setting that controls for disparities in health care access, AAM have a more favorable sRT outcome than MOR.

Humans

Photon-counting detector computed tomography (PCD-CT) in multiple myeloma: a systematic review and trial sequential meta-analysis on image quality and radiation dose.

OBJECTIVES: To systematically review and perform a meta-analysis comparing the effects of PCD-CT versus EID-CT on image quality (sharpness) and radiation dose (CTDIvol) in patients with bone lesions due to multiple myeloma&#xa0;(MM). METHODS: A comprehensive search of PubMed, Embase, Scopus, and Cochrane Central was conducted from inception to October 2025. Studies comparing PCD-CT and EID-CT in MM patients were included. Methodological quality was assessed using ROBINS-I, and the certainty of evidence was assessed using GRADE. RESULTS: A total of 41 studies were identified that matched our search criteria. After duplicate removal and screening, five studies (n = 170 patients) were included in the systematic review, with four contributing to the meta-analysis. PCD-CT showed a significant pooled mean difference in image sharpness (mean difference, + 0.99 points; 95% CI, 0.62-1.37; p < 0.001). PCD-CT also demonstrated a reduction in radiation dose (mean difference, -4.95 milligrays; 95% CI, -8.39 to -1.50; p = 0.005). Trial sequential analysis (TSA) confirmed stability of pooled estimates, with conclusive evidence for image sharpness improvement, and suggestive yet incomplete evidence for radiation dose reduction. CONCLUSION: Compared to EID-CT in MM, PCD-CT significantly improves subjective image sharpness as supported by trial sequential analysis. Conventional meta-analysis suggested a reduction in radiation dose with PCD-CT; however, trial sequential analysis indicated that the cumulative evidence remains inconclusive. Further large-scale studies are suggested to confirm the magnitude of the radiation dose reduction benefit.

Humans

A reanalysis of the Hitachi cohort study evaluating the effectiveness of low-dose CT screening for lung cancer.

The effectiveness of low-dose thoracic computed tomography (CT) screening for lung cancer for non-smokers or light smokers has been unclear. The results of the Hitachi cohort study performed by the conventional multivariable analysis suggested the reduction of lung cancer mortality by thoracic CT screening, but also revealed the lower all-cause mortality in the CT group, which indicated the existence of self-selection bias. Because the background of the subjects in the CT screening group and that in the X-ray screening group were very different, it is critical to adjust appropriately the confounding factors. In this brief report, we describe a re-evaluation of the results of the Hitachi Cohort Study performed by using more flexible methods, propensity score matching and inverse probability weighting.

epidemiology/public health

Effects of 12 weeks of resistance and concurrent training with graded protein intakes on lipid profile, kidney and liver biomarkers in middle-aged to older women.

PURPOSE: To examine secondary lipid, kidney-related, and liver-enzyme responses to three protein intakes during resistance training (RT) alone or the same RT plus cycling (CT) in middle-aged to older women. METHODS: In this randomized 2&#xd7;3 factorial trial, 108 women aged 40-77 years were assigned to RT or CT and 0.8, 1.6, or 2.2 g kg-1 d-1 protein for 12 weeks. This complete-case secondary analysis included 83 participants. Linear mixed-effects models tested Time &#xd7; Training, Time &#xd7; Protein, and Time &#xd7; Training &#xd7; Protein effects, with false-discovery-rate-adjusted omnibus tests and Holm-adjusted contrasts. RESULTS: Triglycerides, total cholesterol, LDL-C, and apolipoprotein B decreased and HDL-C increased in all conditions. Lipid changes differed by protein condition, and several were more favorable with CT; however, CT comprised RT plus additional cycling and greater exercise exposure. Urea, blood urea nitrogen, creatinine, the blood urea nitrogen-to-creatinine ratio, and cystatin C increased, whereas three eGFR estimates decreased. Responses differed mainly between 0.8 and the two higher protein conditions, with little evidence of differences between 1.6 and 2.2 g kg-1 d-1. ALT, AST, and GGT differed by protein condition; AST and GGT also showed training-dependent responses. CONCLUSIONS: The dietary and exercise interventions modified lipid and clinical-chemistry responses. Because energy and food composition were not fully matched and CT added cycling to RT, the findings do not isolate protein dose or exercise modality. Changes in eGFR estimates and liver enzymes do not establish organ injury or long-term safety.

Humans

Performance of Photon-counting CT for Assessing Pretreatment Breast Cancer: Comparison with Mammography, MRI, and 18F-FDG PET/CT.

Background Photon-counting CT (PCCT) offers improved spatial resolution, contrast to noise ratio, and dose efficiency, but its clinical utility remains incompletely defined for breast cancer. Purpose To evaluate the feasibility of PCCT for pretreatment breast cancer assessment through comparisons with MRI, full-field digital mammography (FFDM), and fluorine 18 (18F) fluorodeoxyglucose (FDG) PET/CT. Materials and Methods In this prospective study (March-May 2025), female participants with breast lesions categorized as Breast Imaging Reporting and Data System 4C or higher at US or FFDM underwent breast MRI and multiphasic contrast-enhanced PCCT. 18F-FDG PET/CT was performed in a subset with locally advanced disease. Four radiologists independently evaluated lesion morphologic characteristics, additional findings, and clinical TNM stage. Agreement was analyzed using intraclass correlation coefficients (ICCs) and &#x3ba; statistics. The diagnostic performance for additional lesions and nodal metastasis was compared with the reference standard (pathologic examination). Results Among 126 participants (mean age, 58.1 years &#xb1; 12.3 [SD]), interreader agreement across PCCT, MRI, and FFDM was good to excellent. PCCT agreed with MRI for lesion characterization (&#x3ba; = 0.57-0.96) and clinical T categorization (&#x3ba; = 0.86-0.88), with highest agreement with pathologic size (ICC, 0.70-0.81). For 46 pathologically confirmed additional lesions, PCCT was more sensitive than FFDM (difference, 44% [95% CI: 19, 66]) and similar to MRI (difference, 7% [95% CI: -5, 21]). Additionally, 44% (95% CI: 27, 52) of microcalcifications were missed at PCCT versus FFDM. For pathologically confirmed nodal metastasis, PCCT was more sensitive (difference, 10% [95% CI: 1, 20]) and accurate (difference, 6% [95% CI: 1, 11]) than MRI. For clinical N category, PCCT agreed with PET/CT (&#x3ba; = 0.82 [95% CI: 0.62, 0.96]; n = 19). Two distant metastases identified at PCCT were consistent with 18F-FDG PET/CT and pathologic findings. Conclusion PCCT demonstrated similar performance to MRI for lesion characterization and detection of additional lesions, with better performance for nodal metastasis evaluation; however, detection of microcalcifications was limited. &#xa9; RSNA, 2026 Supplemental material is available for this article.

Humans

Discrepancies in CPAK classification between CT and long-leg radiography: a systematic review and meta-analysis.

OBJECTIVE: To determine whether substantial differences in coronal plane alignment of the knee phenotype distribution, as well as systematic angular measurement discrepancies, exist between CT and long-leg radiography. MATERIALS AND METHODS: From February 2021 to April 2025, we searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials for studies comparing CT- and long-leg radiography-derived coronal plane alignment classifications of the knee in patients with osteoarthritis. The primary outcome was distribution of coronal plane alignment phenotypes. Secondary outcomes included differences in medial proximal tibial angle, lateral distal femoral angle, arithmetic hip-knee-ankle angle, and joint line obliquity. RESULTS: Four studies (1,134 knees) were included. Compared with long-leg radiography-derived classification, CT-derived classification increased type I phenotypes (risk difference: 0.10; 95% confidence interval: 0.01-0.20; P&#x2009;=&#x2009;0.040) and decreased type III (risk difference: -0.04; 95% confidence interval: -0.07 to -0.01; P&#x2009;=&#x2009;0.020) and type V phenotypes (risk difference: -0.04; 95% confidence interval: -0.07 to -0.01; P&#x2009;=&#x2009;0.004). CT yielded significantly lower medial proximal tibial angle (weighted mean difference:&#x2009;-&#x2009;1.18&#xb0;; P&#x2009;<&#x2009;0.001), arithmetic hip-knee-ankle angle (weighted mean difference:&#x2009;-&#x2009;0.95&#xb0;; P&#x2009;<&#x2009;0.001), and joint line obliquity (weighted mean difference:&#x2009;-&#x2009;1.40&#xb0;; P&#x2009;<&#x2009;0.001) than long-leg radiography. Heterogeneity was high for type I phenotype (I2&#x2009;=&#x2009;81%), lateral distal femoral angle (I2&#x2009;=&#x2009;70%), and joint line obliquity (I2&#x2009;=&#x2009;69%). CONCLUSION: Discrepancies between CT-based software-generated and long-leg radiography-derived measurements substantially affect coronal plane alignment classification and angular parameters. Surgeons should consider these modality-specific variations and employ compensatory verification strategies to ensure optimal alignment.

Humans

Which radiographic plane should be used to quantify the distal tibia angle on weightbearing CT images?

BACKGROUND: Precise quantification of distal tibial alignment is essential for planning corrective osteotomies and ankle joint replacement surgery. The lateral distal tibial angle (LDTA) is the principal radiographic parameter used for this purpose. While LDTA is increasingly measured on weightbearing cone-beam CT (WBCT) using two-dimensional coronal slices, the optimal measurement plane remains unclear. METHODS: In this retrospective comparative study, full-leg WBCT scans of patients scheduled for supramalleolar osteotomy (n&#x202f;=&#x202f;20; mean age 47&#x202f;&#xb1;&#x202f;12.8 years) were analyzed. LDTA was measured on three coronal planes of the distal tibial plafond (anterior edge, mid-dome, posterior edge) and compared with semi-automated three-dimensional (3D) tibial alignment measurements as the reference standard. RESULTS: Mid-dome LDTA showed no significant difference from the 3D reference (p&#x202f;>&#x202f;0.05) and demonstrated excellent agreement. Anterior measurements significantly overestimated LDTA, while posterior measurements underestimated it (both p&#x202f;<&#x202f;0.05), with only fair agreement. CONCLUSION: LDTA should be measured at the mid-dome of the distal tibial plafond on WBCT to ensure accurate and reproducible alignment assessment. LEVEL OF EVIDENCE: Level III - Retrospective Comparative Study.

Humans

Impact of Commercial Artificial Intelligence on Radiologist Reading Time for Pulmonary Nodule Evaluation at Chest CT.

Background Chest CT is a primary method for identifying pulmonary nodules, yet interpreting scans remains time-intensive and demanding. Currently, artificial intelligence (AI) is expected to reduce reading times, but the effect of AI on reporting times in this setting is unknown. Purpose To evaluate the impact of a commercial AI software on radiologists' reading time for pulmonary nodule assessment on chest CT scans within a real-world clinical setting. Materials and Methods This retrospective study included patients who underwent chest CT examinations at a tertiary medical center between September 2021 and May 2024. The study period was divided into pre- and post-AI phases. The primary outcome was radiology reporting time. The association between AI implementation and reporting time was evaluated using a multivariable parametric Weibull shared frailty survival model adjusted for reader function, examination type, patient location, and requesting specialty, with clustering at the radiologist level. Interaction analyses assessed heterogeneity across prespecified subgroups. An exploratory extrapolation estimated projected workforce and financial impact. Results This study included 19&#x2009;433 patients (mean age, 62 years &#xb1; 14.2 [SD]; 21&#x2009;814 men; 39&#x2009;323 chest CT examinations, 19&#x2009;190 pre-AI, and 20&#x2009;133 post-AI). AI implementation was associated with faster report completion (adjusted hazard ratio, 1.17; 95% CI: 1.14, 1.21; P < .001). The adjusted median reporting time decreased from 21.3 minutes pre-AI to 18.2 minutes post-AI (14.6% reduction; P < .001). Heterogeneity was observed across reader function (P < .001), examination type (P = .048), and requesting specialty (P = .03). The largest relative reductions were observed for CT thorax electrocardiogram-gated examinations (-41.1%; P < .001) and thoracic radiologists (-25.0%; P < .001), whereas emergency department examinations showed increased median reporting time (7.1%; P < .001). At institutional scan volumes (approximately 20&#x2009;000-22&#x2009;000 chest CT examinations annually), exploratory modeling suggested an approximate reduction of 0.5 full-time equivalent radiologist workload. Conclusion Implementation of commercial AI-assisted pulmonary nodule assessment on chest CT scans reduced radiologist reporting time in a real-world clinical setting. &#xa9; The Author(s) 2026. Published by the Radiological Society of North America under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Iwasawa in this issue.

Humans

Efficacy of a self-guided online resilience intervention for improving mental health among university students: A randomized controlled trial.

Epidemiological data indicates that university students are an at-risk population for the development of mental disorders. Online interventions have been proposed as promising tools for reducing barriers to treatment and establishing easily accessible health-care services promoting mental health and resilience. This study investigated the efficacy of a Learning Management System (LMS)-based self-guided online resilience intervention. 216 university students took part in a randomized controlled trial with an intervention and a waitlist control group and three measurement points (pre, post and follow-up). We conducted per-protocol (PP) and intention-to-treat (ITT) analyses with mental distress as primary outcome, and self-reported resilience and resilience factors as secondary outcomes. Further, attitudes towards online interventions, adherence, satisfaction and possible negative effects were explored. Satisfaction with the intervention was high and PP analyses (n&#x2009;=&#x2009;150) revealed significant improvements in mental distress and self-compassion at post-test and acceptance at follow-up. No favourable effects were found for self-reported resilience and resilience factors. Adherence was low and ITT analyses revealed no significant effects. Overall, the study provides preliminary evidence for the LMS-based self-guided online intervention as a potentially valuable tool for university mental health services under optimal adherence conditions. Further research into determinants of adherence is needed to improve intervention reach.

Humans

Role of routine surveillance stress testing in patients with or without imaging-guided or physiology-guided PCI.

OBJECTIVE: The optimal follow-up strategy for high-risk patients who underwent imaging-guided or physiology-guided percutaneous coronary intervention (PCI) remains uncertain. We investigated whether routine surveillance stress testing after PCI provides clinical benefit when the procedure is guided by intravascular ultrasonography (IVUS) or fractional flow reserve (FFR). METHODS: In the Pragmatic Trial Comparing Symptom-Oriented vs Routine Stress Testing in High-Risk Patients Undergoing PCI randomised trial, 1706 high-risk patients who underwent PCI were assigned to either routine functional testing at 1 year or standard care alone. In this prespecified subgroup analysis, patients were subsequently categorised according to whether IVUS or FFR was used at the index procedure. The primary outcome was a composite of death, myocardial infarction or hospitalisation for unstable angina over 2 years. RESULTS: Among the randomised population, 74% underwent IVUS-guided intervention and 36% underwent FFR-guided intervention. At 2 years, rates of the primary outcome were similar between routine testing and standard care both in patients treated with IVUS guidance (5.3% vs 6.7%; HR 0.79; 95% CI 0.50 to 1.24) and without IVUS guidance (5.7% vs 3.8%; HR 1.52; 95%&#x2009;CI 0.63 to 3.68; interaction p=0.21). Comparable results were observed in patients with FFR guidance (2.6% vs 3.9%; HR 0.65; 95%&#x2009;CI 0.26 to 1.58) and without FFR guidance (7.0% vs 7.1%; HR 0.99; 95%&#x2009;CI 0.63 to 1.55; interaction p=0.59). Routine functional testing was consistently associated with higher use of invasive coronary angiography and repeat revascularisation, without improvement in clinical outcomes. CONCLUSIONS: Among high-risk patients who underwent PCI, routine surveillance stress testing did not reduce the risk of death, myocardial infarction or unstable angina, regardless of the use of IVUS or FFR at the index procedure. Routine functional testing increased downstream invasive procedures without clinical benefit. These findings support guideline recommendations against routine surveillance testing after PCI. TRIAL REGISTRATION NUMBER: NCT03217877.

Humans

Stage shift, histological differentiation, and survival patterns of lung squamous cell carcinoma versus adenocarcinoma in low-dose CT screening.

BACKGROUND: Whether LDCT-associated stage shift translates into similar survival patterns across lung cancer histologies remains uncertain. We compared stage shift, histological differentiation, tumor characteristics, and survival between lung squamous cell carcinoma (LUSC) and adenocarcinoma (LUAD) in the National Lung Screening Trial. METHODS: Among participants diagnosed with LUSC or LUAD, stage distribution and histological differentiation were compared between LDCT and chest X-ray (CXR) arms. Survival among diagnosed cases was measured from randomization. Multivariable models tested screening arm-by-histology interactions. Screen-detected LDCT tumors were compared by histology. RESULTS: During 6.5 years of median follow-up, 498 LUAD and 249 LUSC cases were diagnosed in the LDCT arm, and 374 and 212, respectively, were diagnosed in the CXR arm. LDCT was associated with higher odds of stage I disease for LUAD (adjusted odds ratio [aOR], 2.48; 95% CI 1.88-3.28) and LUSC (aOR, 1.71; 95% CI 1.17-2.48), without significant interaction (P&#x202f;=&#x202f;0.116). LDCT was associated with lower hazard of lung cancer-specific death among diagnosed LUAD cases (adjusted hazard ratio [aHR], 0.54; 95% CI 0.43-0.66), but not among diagnosed LUSC cases (aHR, 1.04; 95% CI 0.78-1.39; P for interaction<0.001). LUSC had lower screening sensitivity, more frequent detection in annual screening rounds, greater prediagnostic tumor size increase, and fewer well-differentiated stage I tumors than LUAD. CONCLUSION: LDCT was associated with stage shift for both subtypes, but favorable survival patterns among diagnosed cases were mainly observed for LUAD. Lower screening sensitivity, greater prediagnostic tumor size increase, and poorer histological differentiation may help explain why stage shift did not translate into similar survival patterns for LUSC. TRIAL REGISTRATION: ClinicalTrials.gov, NCT00047385.

Humans

Intervention Without Borders - an Automated Self-Guided AI-Enhanced Psychoeducation Intervention for Dementia Caregivers: Parallel-Group Randomized Waitlist-Controlled Trial.

OBJECTIVE: To examine whether a fully automated, self-guided intervention (PDC30) could improve caregiver well-being over a 1-month waitlist control in an international sample. DESIGN: Randomized waitlist-controlled trial. SETTING: Web-based platform accessible globally. PARTICIPANTS: 441 individuals responded to study promotion on the internet, of whom 274 from 43 countries met the study criteria and were randomized. Eligible participants were adults providing &#x2265;10 care hours weekly to community-dwelling relatives with dementia, scoring &#x2265;5 on Patient Health Questionnaire-9 (PHQ-9), and without recent caregiver intervention. INTERVENTION: Available 24/7, PDC30 is a self-guided, automated intervention consisting of a Guidebook, an AI-powered counseling chatbot, and interactive applications for cognitive-behavioral techniques, relaxation, and caregiver-recipient bonding. MEASUREMENTS: At baseline and follow-ups at 1, 2, and 3 months, depression was assessed by PHQ-9. Secondary outcomes were measured with validated brief versions of anxiety, burden, and positive gains. RESULTS: Intent-to-treat analysis using mixed-effects regression showed treatment x time2 effects on all outcomes except anxiety. At 1-month follow-up, coinciding with exclusive access to PDC30, intervention caregivers showed significant improvements in depression (d = -0.37), burden (d = -0.34), and positive gains (d = 0.42). The differences mostly disappeared after control participants received the intervention, while improvements in both groups were sustained thereafter. Participants reported using the website several times weekly, were generally satisfied with it, and found the chatbot most helpful. CONCLUSIONS: The effects on depression and other outcomes were consistent with those observed for in-person programs, suggesting the viability of well-designed automated intervention. The study demonstrates the feasibility, acceptability, and potential global health impact of PDC30.

Humans