Search PubMedSearch

SEARCH · Search PubMed

Results for “Bioanalytical methods”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,780 recordsLinked to original sources

Unravelling bioanalytical innovations, degradation processes, and impurity landscapes of VEGFR inhibitors.

From pre-formulation studies to clinical trials, VEGFR-targeted small-molecule tyrosine kinase inhibitors (TKIs) require rigorous analytical standards. Bioanalysis, stability-indicating studies, and impurity profiling are used to examine chromatographic advances for VEGFR-targeted TKIs like sunitinib, pazopanib, axitinib, sorafenib, cabozantinib, vandetanib, apatinib, lenvatinib, nintedanib, and regorafenib. An LC-MS/MS and UPLC-MS/MS routinely show sub ng/mL performance, as shown by LLOQs (0.2 ng/mL) for sunitinib and axitinib, 1 ng/mL for pazopanib, 5-7 ng/mL for sorafenib, 0.5-1.5 ng/mL for regorafenib metabolic products, and 0.1-0.5 ng/mL for lenvatinib. These approaches are used for pharmacokinetics and therapeutic drug monitoring due to their good correlation coefficient of 0.1-10,000 ng/mL, accuracy of 95%-108%, and precision of 15% RSD. UPLC-QTOF-MS/MS distinguishes degradants and metabolites during forced degradation studies, enabling structural elucidation following ICH M7 risk evaluation protocol. HPTLC/MLC offers fast, sensitive screenings, while RP-HPLC/DAD or HPLC-UV offer reliable, cost-effective routine quality-control solutions with LOD/LOQ in the μg/mL range and linearity of 10-240 μg/mL. This review lists the structures and CAS numbers of ten VEGFR-2 TKI degradants and metabolites, as well as pharmacopeial impurities in SMILES forms. It will be useful for future method development and regulatory applications. To ensure VEGFR-targeted TKI quality, safety, and therapeutic efficacy, LC-MS/MS for trace quantification and HRMS for structure elucidation provide a robust, future-oriented framework. To improve VEGFR-targeted TKI quality, safety, and regulatory compliance, analytical development should focus on HRMS-based impurity characterization, AI-assisted degradation prediction, green chromatography, and harmonized bioanalytical validation.

Humans

Validated UPLC-MS/MS quantification and intracellular PK-PD Modeling of periplocin-related cardiac glycosides in H/R-injured H9c2 cells.

Reliable intracellular quantification is essential for characterizing the target-site disposition and exposure-response relationships of bioactive natural products. In this study, an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous determination of periplocin and four related cardiac glycoside metabolites in H9c2 cell lysates. Acceptable linearity, precision, recovery, and stability were achieved for intracellular quantification. Cells were treated with each compound at 50 μM, and intracellular concentrations and cell viability were monitored over 48 h. In hypoxia/reoxygenation (H/R) -injured cells, the time to maximum intracellular concentration was shortened for all five compounds, indicating altered cellular disposition under injury conditions. Cell viability was improved by all compounds during the observation period. Pharmacokinetic-pharmacodynamic (PK-PD) integration was performed using a sigmoid Emax model, and acceptable model fits were obtained, with Akaike information criterion (AIC) values ranging from 79.22 to 130.46. Low apparent EC50 values were estimated under this single-dose design, whereas the estimated Ke0 values suggested delayed equilibration with the effect compartment. These findings indicate that sustained cytoprotective responses can be produced by periplocin and related metabolic markers in injured cardiomyocytes. This intracellular bioanalytical strategy provides a quantitative approach for linking cellular exposure to pharmacodynamic response and may support further evaluation of periplocin-related cardiac glycosides.

Tandem Mass Spectrometry

Development and validation of an LC-MS/MS method for the quantification of the KRASG12C inhibitor divarasib.

Divarasib is a newly developed covalent KRASG12C inhibitor, currently under clinical investigation in a phase 3 trial in patients with non-small cell lung cancer (NSCLC). At the moment, very limited pharmacokinetic data are publicly known. However, obtaining more insight into the pharmacokinetic properties of divarasib is important, since this may provide a better understanding of its efficacy and safety risks. Pre-clinical studies have been performed in mouse models to evaluate the effect of drug transporters and drug-metabolizing enzymes on the plasma exposure and tissue distribution of divarasib. Therefore, a reliable quantification method is required. To our knowledge, no bioanalytical assay of divarasib has been published yet. Therefore, in this study we developed and validated an assay to quantify divarasib in human plasma and in eight different mouse-related matrices, and partially in mouse plasma, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was initially evaluated over a concentration range of 1-10,000 nM. However, due to carry-over observed at 10,000 nM, the validated calibration range was established at 1-2000 nM, with matrix-dependent LLOQs of 1-10 nM. Erlotinib was used as an internal standard and acetonitrile was utilized to perform protein precipitation as sample pretreatment. Divarasib demonstrated stability in human plasma and in mouse plasma and tissue homogenates under various experimental conditions. A pilot in vivo study showed the applicability of our validated LC-MS/MS method. Ongoing clinical trials may collect plasma samples, and this developed method enables quantification of divarasib in both mouse and human plasma samples.

Animals

A phase I clinical study of the safety, tolerability, pharmacokinetics and pharmacodynamics of SHR-2106, an anti-CD40 antibody, following single intravenous or subcutaneous administration in healthy participants.

BACKGROUND: SHR-2106 is a humanized IgG1 monoclonal antibody that blocks CD40-CD40L interactions and has demonstrated immunosuppressive activity and graft-prolonging effects in preclinical studies. This first-in-human Phase I study evaluated the safety, pharmacokinetics, pharmacodynamics, and immunogenicity of single intravenous or subcutaneous doses of SHR-2106 in healthy adults. METHODS: This randomized, double-blind, placebo-controlled Phase I study enrolled healthy participants. Fifty-one participants were enrolled in seven cohorts and received five intravenous doses (50-1200 mg) or two subcutaneous doses (300 and 600 mg). Safety, serum pharmacokinetics, CD40 occupancy on B cells, and anti-drug antibodies were assessed using standard clinical and bioanalytical methods. RESULTS: SHR-2106 demonstrated a favorable safety and tolerability profile, and most treatment-emergent adverse events were mild to moderate laboratory abnormalities with incidence rates comparable to placebo. SHR-2106 exhibited nonlinear pharmacokinetics consistent with target-mediated drug disposition, with a dose-dependent increase in geometric mean terminal half-life following intravenous administration (1.83-10.7 days). Absolute bioavailability after subcutaneous administration was approximately 60%. CD40 occupancy exceeded 80% within 24 h at all doses, with saturation duration increasing from 7 to 70 days across the intravenous dose range and remaining comparable between routes at matched doses. Anti-drug antibody incidence decreased with increasing intravenous dose and did not significantly affect pharmacokinetics or pharmacodynamics. CONCLUSION: SHR-2106 was well tolerated and achieved rapid and sustained CD40 engagement, supporting dose and route selection for Phase II studies.

Humans

Mixed Methods Research on Family Caregiving for Stroke Survivors: A Methodological Systematic Review.

AIM: To examine how mixed methods research has been applied in studies of family caregiving for stroke survivors, focusing on key methodological components (rationale, design types, integration strategies, and use of joint displays). DESIGN: Methodological systematic review. METHODS: A systematic search of five databases yielded 17 studies. The extraction focused on mixed methods features (rationale, design, integration, joint displays), and quality was appraised using the Mixed Methods Appraisal Tool. DATA SOURCES: PubMed, CINAHL, Scopus, Web of Science, and PsycINFO were searched for relevant studies published from 2010 to 2025. RESULTS: The included studies addressed topics such as caregiver burden, coping, resilience, and intervention outcomes. Convergent and explanatory sequential designs predominated. Complementarity was the most frequent rationale for mixing methods. Integration occurred mainly through merging, with fewer instances of connecting or building. Three studies included joint displays to integrate the results. CONCLUSION: Mixed methods research is increasingly applied in family caregiving. To advance the field, researchers should strengthen integration during analysis and results and improve transparency in reporting key design features. IMPLICATIONS FOR THE PROFESSION AND/OR PATIENT CARE: Strengthening methodological rigour in mixed methods studies on stroke caregiving will improve the evidence base for nursing practice. Intentional and meaningful integration of qualitative and quantitative evidence can better inform effective interventions and support programs, ultimately enhancing care for stroke survivors and their families. IMPACT: This review evaluates how mixed methods research is applied in family caregiving studies. It identifies significant methodological gaps, including unclear reporting of design and limited use of advanced integration techniques. The recommendations provide practical guidance for researchers to improve reporting and integration, yielding richer evidence to inform interventions and policies that support family caregivers. REPORTING METHOD: The review followed the PRISMA 2021 guidelines for transparent reporting of systematic reviews. PATIENT OR PUBLIC CONTRIBUTION: No patient or public involvement.

Humans

An Assessment of Reliability Estimation Methods for Binomial Health Care Quality Measures.

We evaluated the performance of commonly used methods for estimating the reliability of binomial health care quality measures using simulated datasets spanning a range of performance score means and variances, numbers of entities, and patient sample sizes. For each simulation, reliability was estimated for all selected methods and compared with the known true reliability derived from the simulation parameters, with methods assessed on their accuracy and precision. Logistic regression with reliability estimated on the outcome scale demonstrated the highest accuracy and precision among all methods evaluated. The widely used Adams beta-binomial method performed poorly, although a modification recommended by Nieser and Harris substantially improved its performance. These approaches are applicable only to binomial measures. Among methods that can be applied to both binomial and continuous measures, permutation resampling of the Spearman rank correlation coefficient was the most accurate and precise, outperforming other commonly used approaches. Overall, for binomial quality measures, logistic regression on the outcome scale is the preferred method for reliability estimation, followed closely by the modified beta-binomial approach, while for non-binomial measures, permutation-based Spearman rank correlation appears to be the most suitable method.

Reproducibility of Results

Natural deep eutectic solvent in situ formation-based extraction method coupled to high-performance anion-exchange chromatography with pulsed amperometric detection for multiclass carbohydrates in hot pot bases.

A novel method was developed for the simultaneous extraction of fourteen multiclass carbohydrates from high-fat foods via the in situ formation of deep eutectic adducts from analytes and acetate ions. Different natural deep eutectic solvents (NADESs) composed of fructose and organic acids were tested as extraction solvents. A model NADES formulated with sodium acetate and fructose was characterized using Fourier transform infrared (FTIR) spectroscopy and hydrogen nuclear magnetic resonance (1H-NMR) spectroscopy. The critical extraction parameters were systematically optimized using multi-response surface methodology (MRSM) with a central composite design (CCD). The extract was analyzed using high-performance anion-exchange chromatography coupled with pulsed amperometric detection (HPAEC-PAD) using a sodium hydroxide-sodium acetate eluent, which did not require organic solvents. This approach exhibited good linearity over the concentration range of 0.02-10 mg L-1, with correlation coefficients (r) ranging from 0.9994 to 0.9999. The limits of detection and quantification were in the ranges of 0.06-0.42 mg kg-1 and 0.19-1.3 mg kg-1, respectively, which were significantly lower than those of liquid chromatography (LC). The protocol was successfully applied to the determination of fourteen carbohydrates in forty-five hotpot seasoning samples. The recoveries ranged from 86.3% to 104.1%, with relative standard deviations (RSDs) of 0.9-7.1%. By integrating multiple techniques, this strategy simplifies operations, shortens extraction time, and achieves baseline separation of three carbohydrate classes that exhibit poor resolution using a conventional LC method. This study describes an efficient procedure for the simultaneous determination of multiple trace-level carbohydrates in complex samples using HPAEC-PAD.

Journal Article

Comparison of three tracking methods to assess usage of two pediatric powered mobility devices for young children with cerebral palsy.

Powered mobility devices are underutilized for promoting self-initiated mobility in young children with cerebral palsy due to prioritization of walking, caregiver effort, device characteristics, and environmental factors. Understanding device usage patterns is important to assess the impact of powered mobility interventions on child outcomes. As part of clinical trial (NCT04684576), three objective tracking methods including integrated loggers, Global Positioning System trackers (GPST), and caregiver reported activity logs (CRAL) were compared to provide insights into device usage patterns. Metrics included play session frequency, session duration, total usage minutes, and unique usage days for two powered mobility devices: Modified Ride-on Cars (MROC) and the Permobil Explorer Mini (EM). Twelve children with cerebral palsy used each device for eight consecutive weeks in home and community settings (16 weeks total), with device ordered randomized. Results showed no significant differences among tracking methods for the MROC. For the EM, only session duration differed between GPST and CRAL. Correlation analysis revealed variable relationships amongst tracking methods for both devices. The EM was used more frequently than the MROC, with significantly greater total usage minutes and session duration via CRAL, not GPST. The findings highlight the need for reliable tracking technologies that can be used across powered mobility devices.

Child, Preschool

Understanding Suicide through Coroners' Narratives: implications for primary care from a mixed‑methods study of 157 Coroners' reports.

Suicide is a major public health concern, and general practice is often a recent point of contact before death. While mental illness is well recognised, the broader social and contextual factors influencing suicide risk remain under-reported in primary care and epidemiological research Aim To describe the demographic, clinical, and psychosocial characteristics of individuals who died by suicide, integrating coronial quantitative data with qualitative narrative accounts to identify implications for primary/ secondary care and public health. Design and setting Explanatory sequential mixed‑methods study of 157 consecutive deaths by suicide recorded by coroners (2018-19) across five English local authorities. Method Demographic, clinical, and social data were extracted from coroners' records and summarised descriptively. Narrative case summaries were coded and analysed thematically to identify contextual, relational, and service factors preceding death. Results Of 157 individuals: 79% were male; 65% lived in the most deprived IMD quintile; 85% had a diagnosed mental health condition; 62% had a long‑term physical illness; 41% had a previous suicide attempt. About half consulted a GP in the preceding three months; mental health featured in about half of those consultations. Common stressors were relationship breakdown (37.2%), housing instability (22.1%), and work pressures (18.2%). Seven interlinked themes were identified: Mental health; Alcohol/Substance use, Physical health; Social connectedness; Life course trauma, Socioeconomic and Structural Vulnerability; Healthcare access. Service transitions were key vulnerability points Conclusion Coroners' records offer important insights into the complex circumstances preceding suicide and highlight opportunities for GPs to recognise intersectional complexity and support integrated, cross-sector suicide prevention approaches.

General Practice

Mixed Methods Findings from a Stepped Wedge Hybrid Implementation Trial of ATTAIN NAV: A Mental Health Family Navigation Intervention for Autistic Youth.

ATTAIN NAV (Access to Tailored Autism Integrated Care through Family Navigation) was delivered by family navigators to promote access to and engagement with mental health services for school-age autistic youth. This study used a mixed method, stepped wedge design to test the effects of family navigation on service and clinical outcomes while gathering information on implementation. Primary care providers from six clinics in California and 56 caregiver-child dyads enrolled in and completed the study. Clinics were randomized to either a technology-enhanced or standard family navigation condition. Caregivers completed assessments at baseline and post about child, family and services outcomes, and a subset participated in a post qualitative interview. Quantitative findings demonstrated improvements in child challenging behavior and parent activation across conditions although these improvements were more pronounced for families in the standard FN condition. At post-intervention, families in the standard FN condition reported higher levels of navigation satisfaction, a shorter time to attend their first mental health appointment, and higher engagement with their navigator. Qualitative findings complemented and expanded the quantitative survey findings. The ATTAIN NAV model of family navigation for autistic children with co-occurring mental health needs demonstrates promising implementation, service, and clinical benefits. Clinical Trials Registration. NCT05344378.

Humans

Performance comparison of rapid and native barcoding methods for Oxford Nanopore sequencing of Poliovirus Viral Protein 1 (VP1) amplicons.

Accurate and timely sequencing of poliovirus is critical for global eradication efforts, particularly for molecular epidemiology based on the typing region of the genome, viral protein 1 (VP1). While Oxford Nanopore Technologies (ONT) sequencing has expanded capabilities for poliovirus surveillance, the relative performance of different ONT library preparation methods, including ligation-based (Native Barcoding) and transposase-based (Rapid Barcoding) approaches, has not been systematically evaluated. In this study, we compared rapid barcoding and native barcoding workflows for sequencing VP1 amplicons from 17 type 2 poliovirus-positive samples, each processed in triplicate. Native barcoding generated significantly more sequencing output, producing approximately 2.3-fold greater total read yield than rapid barcoding, and demonstrated higher run-to-run reproducibility (R2 = 0.979-0.998 vs. 0.847-0.929, respectively; p&#x202f;<&#x202f;0.001). In addition, native barcoding generated 80% of the total yield achieved by rapid barcoding within approximately 7&#x202f;h, whereas rapid barcoding required approximately 40&#x202f;h to reach the same output. Despite these differences, both methods produced identical VP1 consensus sequences across all samples, with comparable read quality (median per-base Q-scores of approximately Q17-Q18). Rapid barcoding provided substantial practical advantages, reducing hands-on library preparation time (55 vs. 200&#x202f;min) and per-sample cost ($12.82 vs. $16.54), while simplifying workflow and reducing technical complexity. These findings indicate that sequencing yield may not be a determinant of downstream analytical outcomes for poliovirus VP1 ONT sequencing. Rapid barcoding therefore represents a cost-effective and efficient approach for routine poliovirus surveillance, whereas native barcoding remains advantageous in applications requiring rapid data generation or maximal sequencing depth.

Poliovirus

Development and validation of a novel LC-MS/MS method for simultaneous quantification of fidaxomicin and metabolite (OP-1118) from feces for gut pharmacobiome studies.

Fidaxomicin is a first-line antibiotic for treating Clostridioides difficile infection. While it has low systemic absorption and reaches high colonic concentrations, it is hydrolyzed to a less active metabolite, OP-1118. Few studies have completely described critical experimental details of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for quantifying fecal fidaxomicin and OP-1118. This study developed and validated a simple, fast, and sensitive LC-MS/MS method to quantify fidaxomicin and OP-1118 in human and mouse feces. This method simplified fecal sample preparation without the use of solid phase extraction and optimized LC-MS/MS parameters. A broad working range (0.3-1000&#xa0;ng/ml) in both diluted human and murine fecal matrices was achieved with good intra- and inter-day accuracy (93-107%), precision (1-7%), and recovery (70-105%) as well as little IS-normalized matrix effects. This method was utilized to quantify fidaxomicin and OP-1118 in human and murine fecal samples. This novel method was simple, fast, sensitive, and accurate in analyzing fecal fidaxomicin and OP-1118 and could be deployed to facilitate gut pharmacobiome research.

Feces

Comparison between the thoracoabdominal rebalancing (TAR) method and the slow expiratory flow acceleration (SEFA) technique in preterm newborns: protocol for a randomised controlled clinical trial.

INTRODUCTION: Preterm newborns (PTNB) present respiratory immaturity and increased susceptibility to muscle fatigue. The thoracoabdominal rebalancing (TAR) method is a physiotherapeutic intervention developed in Brazil that aims to reorganise the synergy of the thoracoabdominal muscles and reduce the effort of the respiratory muscles, a benefit that is particularly important for PTNB; however, the evidence regarding its effectiveness in this population remains inconclusive. Therefore, this study aims to compare the short-term effects of the TAR method and the slow expiratory flow acceleration (SEFA) technique in improving respiratory distress and peripheral oxygen saturation (SpO2) in PTNB admitted to neonatal intensive care unit (NICU). METHODS AND ANALYSIS: The study will be a randomised, controlled, two-arm, parallel-group, single-blind clinical trial. 68 participants will be randomly assigned to one of the two treatment groups. Group 1 will receive four handling techniques of the TAR method for 10&#x2009;min, followed by the rhinopharyngeal retrograde clearance with saline instillation (RRC+I) technique. Group 2 will receive the SEFA technique for 10&#x2009;min, also followed by RRC+I. Primary outcomes are respiratory distress and SpO2. Secondary outcomes are respiratory rate (RR), heart rate (HR), pain, behaviour and diaphragmatic excursion. Assessments will be conducted by a blinded researcher at baseline (T0), immediately after the intervention (T1) and at the 30-minute follow-up (T2). Data will be described using measures of central tendency and dispersion and absolute and relative frequencies. An intention-to-treat analysis will be performed, and intragroup and intergroup comparisons will be assessed using generalised estimating equations (GEE). ETHICS AND DISSEMINATION: The Research Ethics Committee of the Faculty of Health Sciences of Trairi of the Federal University of Rio Grande do Norte approved this study (number 8,055,786). The results will be disseminated through peer-reviewed journal publications, scientific conferences presentations and knowledge translation to the public. TRIAL REGISTRATION NUMBER: This study was registered on Brazilian Registry of Clinical Trials (ReBEC) on 9 January 2026 (RBR-3gbsyc2).

Humans

Comparison of black carbon measurements using filter-specific reference transmittance to those using lab blanks or an average of unloaded filters.

Filter-based optical techniques compare light transmission intensities between loaded (I) and unloaded (I0) filters as a measure of light-absorbing mass for subsequent estimations of equivalent black carbon (eBC). We analyzed 5,379 15&#x2009;mm Teflon filters from the Household Air Pollution Intervention Network (HAPIN) trial to assess the influence that different methods of I0 estimations have on eBC measures. We compared eBC measurements using filter-specific I0 values (Method 1) to those using three other methods of I0 estimation: the lab blank scan from a given session (Method 2), the average of all pre-sample filter scans (Method 3), and the average of all lab blank filter scans (Method 4). We assessed the agreement between Method 1 and the alternative methods using Bland-Altman analysis. We also assessed the relationship between Method 1 and the alternative methods across the complete measurement range and after stratifying exposure data into quartiles according to Method 1 eBC exposures. The mean (SD) personal eBC exposure for Method 1 was 7.8&#x2009;&#x3bc;g/m3 (5.9), and exposures ranged from 1.3 to 46.8&#x2009;&#x3bc;g/m3. Compared to Method 1, eBC using Methods 2, 3, and 4 were higher by 0.7&#x2009;&#x3bc;g/m3, 0.1&#x2009;&#x3bc;g/m3, and 0.7&#x2009;&#x3bc;g/m3, respectively. The performances of linear regression models between Method 1 and all other methods were moderate to strong (R2 range: 0.42-0.93) in the second, third, and fourth quartiles; however, the models in the first quartile (eBC range: 1.3-2.9&#x2009;&#x3bc;g/m3) performed poorly (R2&#x2009;=&#x2009;0.25-0.26), with error approximately 25% of the mean. Our findings suggest that, in most instances, conventional methods for obtaining I0 values can be used to sufficiently characterize eBC; however, analyzing filters before sampling adds appreciably to the accuracy of eBC estimations in lower concentration settings.Implications: Filter-based optical techniques compare light transmission intensities between loaded (I) and unloaded (I0) filters as a measure of light-absorbing mass for subsequent estimations of equivalent black carbon (eBC). To assess the influence that different methods of I0 estimations have on eBC measures, we analyzed 5,379 15 mm Teflon filters from the Household Air Pollution Intervention Network (HAPIN) trial. Our findings suggest that, in most instances, conventional methods for obtaining I0 values can be used to sufficiently characterize eBC; however, analyzing filters before sampling adds appreciably to the accuracy of eBC estimations in lower concentration settings.

Soot

Citizenship Status and Contraceptive Method Use Among Latinx, Asian and Pacific Islander (API) Women in California.

Citizenship status confers rights and access to healthcare, yet little is known about how it impacts contraception use and type of method use. This study examined the role of citizenship status on contraceptive use among reproductive-aged (18-44 years), cis-gender Latinx and Asian and Pacific Islander (API) women. This study used the 2017-2020 waves of the California Health Interview Survey (CHIS). Inclusion criteria included cisgender, heterosexual Latinx and API women of reproductive age (18-44 years) who were at risk of becoming pregnant (N&#x2009;=&#x2009;3,027). Participants were classified into the following categories based on their citizenship status: non-citizens without a green card, legal permanent residents (LPRs), naturalized citizens, and U.S.-born citizens. We conducted bivariate analyses using Pearson's chi-square tests and multivariable analyses using adjusted binomial logistic regressions to assess associations between citizenship status and use of any modern and reversible method of contraception and type of method used. Models were stratified by race/ethnicity. All analyses were weighted. Three-quarters (75.8%) of the sample were Latinx, 57.5% were U.S.-born citizens, 16.3% were naturalized citizens, 10.6% were LPRs, and 15.7% were non-citizens without a green card. There were no significant differences in the type of contraception method use by citizenship status among Latinx. Among API, naturalized citizens had lower odds of any use and condom use and naturalized citizens and U.S.-born citizens had higher odds of using pill or other hormonal methods and IUD or implant compared to non-citizens without a green card. This study makes important contributions in understanding the role of citizenship status as a social determinant of reproductive health for Latinx and API in California.

Citizenship status

Vitamin B12 Deficiency in Sickle Cell Disease: Method-Driven Estimates and Systematic Diagnostic Misclassification.

OBJECTIVES: To determine whether the reported 0%-70% prevalence of vitamin B12 deficiency in sickle cell disease (SCD) reflects true population variation or diagnostic misclassification. METHODS: We conducted a PRISMA 2020-compliant systematic review of observational studies (January 1, 2000-May 13, 2026; PROSPERO CRD420251087800) assessing B12 status in SCD. PubMed, AJOL, and Google Scholar were searched with citation tracking and dual screening. Diagnostic validity was assessed across biomarker strategy, analytical platform, thresholds, and confounder control using a proposed context-integrated framework to classify methodological robustness and discordance. RESULTS: Fourteen studies were included (57% high-income; 43% LMIC). The evidence base was dominated by limited diagnostic approaches: 71% used immunoassays, over one-third relied on circulating B12 alone, and functional biomarkers were inconsistently applied without systematic confounder adjustment. Prevalence estimates were strongly influenced by diagnostic methods rather than underlying population biology, ranging from 0% to 70% in single-marker studies (mostly 0%-7.1%, with outliers ~50%-70%) and 6.9%-53% in multi-marker studies. Discordance was substantial and greater in LMIC settings than HIC. CONCLUSION: Current diagnostic approaches in SCD appear method-dependent, generating heterogeneous prevalence estimates with uncertain clinical validity. These findings challenge existing estimates and have implications for clinical practice, research design, and diagnostic equity. TRIAL REGISTRATION: ClinicalTrials.gov identifier: CRD420251087800.

Humans

Standardized visual overlays enhance laparoscopic instruction: A mixed-methods evaluation.

Effective communication during laparoscopic procedures is frequently undermined by spatial disorientation and inconsistent terminology between instructors and trainees. This study examined whether standardized visual overlays on endoscopic monitors could enhance communication and learning. We conducted a three-phase mixed-methods study: qualitative observation of 20 laparoscopic teaching cases; a randomized trial of 63 second-year medical students assigned to control, clock, or alphanumeric grid (AG) overlays during three trials of a standardized transfer task; and intraoperative implementation in 44 cases (30 AG, 14 clock) with post-case surveys and qualitative feedback. In simulation, the clock overlay produced the fastest completion times, whereas the AG yielded the lowest error scores, and both overlays outperformed the control. Intraoperatively, the AG was rated higher than the clock for communication clarity, spatial orientation, perceived operative efficiency, and trainee confidence. Standardized visual overlays, particularly the AG, appear to support intraoperative teaching by providing a shared spatial frame of reference.

Laparoscopy