Search PubMedSearch

SEARCH · Search PubMed

Results for “Gray matter volume”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

147 records · Page 9Linked to original sources

Artificial Intelligence Cannot Replace Peer Reviewers but May Help Editors Triage: A Comparative Analysis of a Large Language Model and Human Reviewer Recommendations at the American Journal of Sports Medicine.

BACKGROUND: The peer review system faces increasing strain from rising manuscript volumes, reviewer fatigue, and well-documented interreviewer disagreement. Large language models (LLMs) have shown potential to support the peer review process, but their ability to replicate editorial decisions at high-impact medical journals and their utility as manuscript screening tools remain unknown. PURPOSE: To compare the agreement between an LLM and the final editorial decision on manuscripts submitted to the American Journal of Sports Medicine and to evaluate the potential of LLMs as a manuscript screening tool. STUDY DESIGN: Cross-sectional agreement study. METHODS: Fifty-four manuscripts randomly selected from submissions to the American Journal of Sports Medicine (September 2024-October 2024) were reviewed by a locally deployed LLM (Ministral 3 14B; Mistral AI) using a standardized prompt. The artificial intelligence (AI) produced a categorical recommendation (reject, cascade, revision, or accept) and a numerical score (0-100) for each manuscript. Agreement with the final editorial decision was assessed by Cohen kappa (4-category model) for pooled human reviewers (n = 139 reviews) and the AI (n = 54). Screening performance was evaluated by positive predictive value (PPV), sensitivity, and specificity. RESULTS: Pooled human reviewers demonstrated fair agreement with the final decision (&#x3ba; = 0.181 [P < .001]; 42.4% agreement), while the AI demonstrated slight, nonsignificant agreement (&#x3ba; = 0.126 [P = .099]; 37.0% agreement). The AI recommended revision for 61.1% of manuscripts, of which 72.7% were ultimately rejected or cascaded, demonstrating systematic "revision bias." When the AI recommended rejection, 54.5% of those manuscripts were ultimately rejected and 27.3% were cascaded; when the AI recommended cascade, 50% were rejected and 50% were cascaded. However, when the AI recommended rejection or cascade (n = 21), 90.5% received a final decision of rejection or cascade (PPV, 90.5%; specificity, 81.8%). Manuscripts with an AI score <70 were rejected or cascaded 88.0% of the time (PPV, 88.0%). CONCLUSION: AI cannot replicate the nuanced judgment of human peer reviewers at a high-impact sports medicine journal. When AI recommended rejection or cascade, 90.5% of manuscripts received that final decision (descriptive PPV, 90.5%; 95% CI, 71.1%-97.3%), suggesting potential utility as an exploratory first-pass screening tool warranting further validation in larger cohorts. However, AI could not reliably distinguish manuscripts destined for outright rejection from those that would be cascaded to a sister journal-an important limitation for editorial triage applications.

Sports Medicine

Aquablation/AquaBeam Waterjet Therapy for Benign Prostatic Hyperplasia: Three-Year Functional and Ejaculatory Outcomes in a Multicenter Real-World Italian Cohort.

OBJECTIVE: To evaluate the 3-year functional outcomes of Aquablation/AquaBeam waterjet therapy for bladder outlet obstruction secondary to benign prostatic hyperplasia (BPH), with particular attention to urinary symptoms, quality of life, continence, ejaculatory function, and complications. METHODS: We performed a retrospective analysis of a prospectively maintained multicenter database including 218 consecutive men who underwent Aquablation/AquaBeam for symptomatic BPH between January 2019 and January 2022 at three referral centers. Functional outcomes assessed preoperatively and during follow-up included International Prostate Symptom Score (IPSS), IPSS quality-of-life item (IPSS-QoL), maximum urinary flow rate (Qmax), post-void residual urine (PVR), continence, and ejaculatory function. Median follow-up was 36&#x2009;months. Ejaculatory preservation was evaluated only in patients with preserved antegrade ejaculation at baseline. RESULTS: Median age was 61&#x2009;years (IQR 57-66), median prostate-specific antigen (PSA) was 2.52&#x2009;ng/mL (IQR 0.40-21.60), and median prostate volume was 55&#x2009;mL (IQR 40-73). Median operative time was 56&#x2009;min, while median catheterization time and length of hospital stay were both 48&#x2009;h. Functional improvements were evident from the 3-month follow-up and remained stable through 36&#x2009;months. At 36&#x2009;months, median IPSS improved to 5 and median Qmax to 18&#x2009;mL/s. Median PSA changed modestly from 2.52&#x2009;ng/mL at baseline to 2.75&#x2009;ng/mL at 36&#x2009;months. No cases of de novo urinary incontinence were observed throughout follow-up. Among patients with preserved antegrade ejaculation at baseline, 87% maintained antegrade ejaculation at 36&#x2009;months. Most postoperative complications were minor (Clavien-Dindo grade I-II, 20.2%). One grade III rectal injury occurred (0.5%). Median hemoglobin decreased from 15.2&#x2009;g/dL preoperatively to 14.0&#x2009;g/dL before hospital discharge, and two patients required blood transfusion. During the 36-month follow-up, no surgical retreatment was required, whereas 11 patients (5.0%) received temporary medical retreatment. CONCLUSION: In this multicenter real-world cohort, Aquablation/AquaBeam was safe and effective over 3&#x2009;years, providing durable improvement in lower urinary tract symptoms and quality of life while preserving continence and antegrade ejaculation in most patients. These findings support Aquablation/AquaBeam as a valuable minimally invasive surgical option for selected men with BPH, particularly those who prioritize preservation of ejaculatory function. Longer-term and comparative studies are warranted. TRIAL REGISTRATION: 48281.

Humans

Structured robotic colorectal training in a non-tertiary NHS hospital: a 502-case consecutive cohort implementation study.

Robotic-assisted colorectal surgery has expanded rapidly across NHS practice in the UK. Structured unit-wide training pathways are essential for safe technology adoption, yet published outcome data from non-tertiary hospitals remain limited. This study describes the implementation and feasibility of a unit-wide robotic colorectal program at a high-volume non-tertiary hospital, reporting outcomes across 502 consecutive resections performed by eight consultant surgeons and presenting these in the context of nationally published benchmarks. A retrospective cohort study of 502 consecutive robotic colorectal resections performed at York Teaching Hospital between May 2022 and December 2025. Eight consultant surgeons (A-H) participated in a structured four-phase training pathway incorporating simulation training, proctored cases, complexity-based case progression, and formal credentialing. Primary outcomes were 30-day mortality, unplanned return to theatre (RTT), and anastomotic leak (AL). Anastomotic leak was calculated using only patients who underwent anastomosis as the denominator. Procedure-stratified and individual surgeon outcomes with 95% confidence intervals were reported. Risk-adjusted cumulative sum (RA-CUSUM) analysis was performed to evaluate learning curves. Outcomes are presented descriptively alongside nationally published reference data; no formal statistical comparison against national benchmarks was performed. 502 robotic colorectal resections were performed. Mean patient age was 70.0 &#xb1; 11.3&#xa0;years; 58.4% were male. Median ASA grade was III. The indication was malignancy in 89.2% of cases. Length of stay was non-normally distributed and is therefore reported using median and interquartile range in the revised analysis. Key outcomes: - 30-day mortality: 1.0% (5/502; 95% CI 0.4-2.3%) - Unplanned return to theatre (RTT): 5.2% (26/502; 95% CI 3.6-7.5%) - Anastomotic leak (AL): 3.3% (15/450; 95% CI 2.0-5.5%; denominator = patients with anastomosis) - 30-day unplanned readmission: 5.0% (25/502; 95% CI 3.4-7.2%) - Conversion to open surgery: 3.6% (18/502; 95% CI 2.3-5.6%) - Lymph node yield &#x2265;12: 91.3% of cancer resections - R0 resection rate: 95.1% of cancer resections All primary outcomes fell within or below the published reference ranges used for descriptive context. RA-CUSUM trajectories were heterogeneous: no surgeon crossed the predefined upper control limit, but several curves showed later upward movement. Accordingly, the analysis is interpreted as safety surveillance rather than evidence of uniform performance improvement. RA-CUSUM monitoring showed that no surgeon crossed the predefined upper control limit; however, heterogeneous trajectories precluded a claim of uniform performance improvement.

Humans