Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Liquid Phase Microextraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8Linked to original sources

Automated in-tube solid-phase microextraction coupled with liquid chromatography-electrospray ionization mass spectrometry for the determination of selected benzodiazepines.

A simple, rapid, and sensitive method, which allowed us to simultaneously determine seven benzodiazepines (diazepam, nordiazepam, temazepam, oxazepam, 7-aminoflunitrazepam, N-desmethylflunitrazepam, and clonazepam) in buffer solution and in urine and serum samples, was investigated by automated in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS). In-tube SPME, in which the analytes were extracted from the sample directly into an open tubular capillary column by repeated draw/eject cycles of sample solution, is an extraction technique for organic compounds in aqueous samples. The separation of benzodiazepines was carried out under ion-suppressed reversed-phase conditions by using methanol/50mM ammonium acetate in water (60:40) as a mobile phase with a Supelco LC-18 column. The optimal extraction condition was 10 draw/eject cycles of 30 mL of sample in 100mM Tris-HCl (pH 8.5) at a flow rate of 0.3 mL/min using a piece of 60-cm length Supelco-Q plot capillary column as the extraction capillary. The quantitative study was explored by operating in selected-ion monitoring (SIM) mode. The calibration curves were linear in the range from 0.5 ng/mL or 2 ng/mL to 500 ng/mL. The detection limits were from 0.02 ng/mL to 2 ng/mL. At the optimized capillary and fragmentor voltages, the characteristic ions for each compound clearly showed up in the spectra and it is possible to use the LC-MS to identify these compounds. The method was applied to the analysis of biological samples without interfering peaks. However, the recoveries for some of the compounds in serum samples need to be further improved.

Benzodiazepines↗

Determination of hydroxyaromatic compounds in water by solid-phase microextraction coupled to high-performance liquid chromatography.

Solid-phase microextraction (SPME) coupled with high-performance liquid chromatography (HPLC) for the analysis of hydroxyaromatic compounds is described. Three kinds of fibers [50 microns carbowax-templated resin (CW-TPR), 60 microns polydimethylsiloxane-divinylbenzene (PDMS-DVB) and 85 microns polyacrylate (PA) fibers] were evaluated. CW-TPR and PDMS-DVB were selected for further study. The parameters of the desorption procedure (such as desorption mode, the composition of the solvent for desorption and the duration of fiber soaking) were studied and optimized. The effect of the structure and physical properties of analytes, carryover, duration of absorption, temperature of absorption, pH and ionic strength of samples were also investigated. The method was applied to environmental samples (lake water) using a simple calibration curve.

Adsorption↗

Determination of plastic monomers in water by solid-phase microextraction coupled with liquid chromatography.

A method is presented for the determination of 2 major plastic monomers, terephthalic acid and vinyl acetate, which are widely used to manufacture plastics that come in contact with foods. The analytes are extracted from aqueous solution by using solid-phase microextraction, followed by quantitation by liquid chromatography (LC) with UV detection. Multivariate optimization was applied and is described. The optimized method has linear ranges of 5-150 microg/g for terephthalic acid and 7.5-100 microg/g for vinyl acetate. Coefficients of variation at a spiking level of 20 microg/g were 13.6% for terephthalic acid and 3.1% for vinyl acetate; detection and quantitation limits were 0.59 and 1,99 microg/g, respectively, for terephthalic acid and 1.56 and 5.20 microg/g, respectively, for vinyl acetate. The characteristics of both the extraction technique and its coupling with LC are described and discussed.

Chromatography, Liquid↗

Solvent-free method for the determination of polynuclear aromatic hydrocarbons in waste water by solid-phase microextraction-high-performance liquid chromatography with photodiode-array detection.

Solid-phase microextraction (SPME) has rapidly been established among the practical alternatives for sample preparation for gas chromatography. Nevertheless polynuclear aromatic hydrocarbons (PAHs) are more effectively monitored by high-performance liquid chromatography (HPLC), but initially, there was no simple way to introduce analytes extracted by SPME into an HPLC system. A SPME-HPLC interface was developed by Supelco, which enables one to take advantages of the time and solvent savings offered by SPME. In the present work six PAHs from the European Union directives: fluoranthene, benzo[b]fluoranthene, benzo[k]fluoranthene benzo[a]pyrene, benzo[ghi]perylene, indeno[1,2,3-cd]pyrene were evaluated after optimization of a sample preparation method with a 100-micron poly(dimethylsiloxane) fiber. Repeatability, reproducibility, correlation coefficients, linearity, recoveries and limits of detection where determined and are indicated.

Chromatography, High Pressure Liquid↗

Simultaneous determination of ochratoxin A and cyclopiazonic, mycophenolic, and tenuazonic acids in cornflakes by solid-phase microextraction coupled to high-performance liquid chromatography.

A solid-phase microextraction (SPME) method, coupled to liquid chromatography with diode array UV detection (LC-UV/DAD), for the simultaneous determination of cyclopiazonic acid, mycophenolic acid, tenuazonic acid, and ochratoxin A is described. Chromatographic separation was achieved on a propylamino-bonded silica gel stationary phase using acetonitrile/methanol/ammonium acetate buffer mixture (78:2:20, v/v/v) as mobile phase. SPME adsorption and desorption conditions were optimized using a silica fiber coated with a 60 microm thick polydimethylsiloxane/divinylbenzene film. Estimated limits of detection and limits of quantitation ranged from 3 to 12 ng/mL and from 7 to 29 ng/mL, respectively. The method has been applied to cornflake samples. Samples were subjected to a preliminary short sonication in MeOH/2% KHCO(3) (70:30, v/v); the mixture was evaporated to near dryness and reconstituted in 1.5 mL of 5 mM phosphate buffer (pH 3) for SPME followed by LC-UV/DAD. The overall procedure had recoveries (evaluated on samples spiked at 200 ng/g level) ranging from 74 +/- 4 to 103 +/- 9%. Samples naturally contaminated with cyclopiazonic and tenuazonic acids were found; estimated concentrations were 72 +/- 9 and 25 +/- 6 ng/g, respectively.

Chromatography, High Pressure Liquid↗

Automated in-tube solid-phase microextraction-high-performance liquid chromatography for carbamate pesticide analysis.

In-tube solid-phase microextraction (SPME) is an automated version of SPME that can be easily coupled to a conventional HPLC autosampler for on-line sample preparation, separation and quantitation. It has been termed "in-tube" SPME because the extraction phase is coated inside a section of fused-silica tubing rather than coated on the surface of a fused-silica rod as in the conventional syringe-like SPME device. The new in-tube SPME technique has been demonstrated as a very efficient extraction method for the analysis of polar and thermally labile analytes. The in-tube SPME-HPLC method used with the FAMOS autosampler from LC Packings was developed for detecting polar carbamate pesticides in clean water samples. The main parameters relating to the extraction and desorption processes of in-tube SPME (selection of coatings, aspirate/dispense steps, selection of the desorption solvents, and the efficiency of desorption solvent, etc.) were investigated. The method was evaluated according to the reproducibility, linear range and limit of detection. This method is simple, effective, reproducible and sensitive. The relative standard deviation for all the carbamates investigated was between 1.7 and 5.3%. The method showed good linearity between 5 and 10000 microg/l with correlation coefficients between 0.9824 and 0.9995. For the carbamates studied, the limits of detection observed are lower than or similar to that of US Environmental Protection Agency or National Pesticide Survey methods. Detection of carbaryl present in clean water samples at 1 microg/l is possible.

Carbamates↗

Determination of bisphenol-type contaminants from food packaging materials in aqueous foods by solid-phase microextraction-high-performance liquid chromatography.

A fast screening method consisting of off-line solid-phase microextraction coupled to HPLC and fluorescence detection, suitable for the analysis of several bisphenol derivatives and their degradation products in aqueous solution, has been developed. Detection limits of 0.7 ng ml(-1) for 2,2-bis[4-(glycidyloxy)phenyl]propane, 0.9 ng ml(-1) for bisphenol A bis(3-chloro-2-hydroxypropyl)ether, 1.1 ng ml(-1) for 2,2-bis(4-hydroxyphenyl)propane and 2.4 ng ml(-1) for bisphenol F diglycidyl ether have been achieved working in the linear range 10-500 ng ml(-1). The good analytical features achieved make the proposed method an interesting option for the direct determination of these compounds in aqueous canned food such as peas, tuna, olives, maize, artichokes or palm hearts. Both the optimization process and the results, including the analysis of real samples, are given and discussed.

Benzhydryl Compounds↗

Determination of naproxen in human urine by solid-phase microextraction coupled to liquid chromatography.

An SPME-LC-UV method for the determination of the non-steroidal anti-inflammatory drug (NSAID) naproxen and, after hydrolysis, its glucuronide in human urine samples was developed for the first time using a carbowax/templated resin (CW/TPR-100)-coated fibre. The procedure required a very simple sample pre-treatment, an isocratic elution, and provides a highly selective extraction. All the aspects influencing adsorption (extraction time, temperature, pH and salt addition) and desorption (desorption and injection time and desorption solvent mixture composition) of the analyte on the fibre have been investigated. The linear range investigated in urine was 0.2-20 microg/ml (that covers the typical naproxen urinary concentration) and almost quantitative recoveries were obtained. Within-day and between-days R.S.D.% in urine were 4.5 and 6.0, respectively. The LOD and LOQ in spiked urine were 0.03 and 0.20 microg/ml, well below the usual naproxen urinary level.

Adsorption↗

Poly(acrylamide-vinylpyridine-N,N'-methylene bisacrylamide) monolithic capillary for in-tube solid-phase microextraction coupled to high performance liquid chromatography.

In-tube solid-phase microextraction (SPME) based on a poly(acrylamide-vinylpyridine-N,N'-methylene bisacrylamide) monolithic capillary was investigated and on-line coupled to HPLC for the determination of trace analytes in aqueous samples. The polymer monolith was conveniently synthesized in a fused silica capillary by in situ polymerization method. Several groups of analytes including non-steroidal anti-inflammatory drugs, phenols, non-peptide angiotensin II receptor antagonists and endocrine disrupting chemicals were extracted by the monolithic capillary. High extraction efficiency was achieved for the analytes investigated and great improvement of the limits of detection were obtained in comparison to that of direct chromatographic analysis and strong hydrophobic and ion-exchange interactions between the analytes and the polymer were confirmed. The newly developed monolithic capillary showed excellent reusability and high stability under extreme pH conditions during extraction. The possibility of applying the established method to water sample analysis was also demonstrated.

Chromatography, High Pressure Liquid↗

Detection of the isoflavone aglycones genistein and daidzein in urine using solid-phase microextraction-high-performance liquid chromatography-electrospray ionization mass spectrometry.

An improved method of detection of the isoflavone aglycones, genistein and daidzein, is reported using solid-phase microextraction-high-performance liquid chromatography-electrospray ionization mass spectrometry (SPME-HPLC-ESI-MS). Extraction of the isoflavonoids from urine using SPME with a Carbowax-templated resin fiber coating allows rapid preconcentration of the analytes without the usual sample preparation required by other methods. Detection of the analytes is accomplished by HPLC-ESI-MS. Analysis of spiked samples of urine resulted in a linear range of 0.25 to 250 ng/ml for daidzein and 0.27 to 27.0 ng/ml for genistein. Limits of detection of daidzein and genistein were measured at 25.4 pg/ml for daidzein and 2.70 pg/ml for genistein. Daidzein and genistein were detected in urine following consumption of a soy drink.

Chromatography, High Pressure Liquid↗

Dynamic liquid-liquid-liquid microextraction with automated movement of the acceptor phase.

A new dynamic liquid-liquid-liquid microextraction procedure, with the automated movement of acceptor phase (LLLME/AMAP) to facilitate mass transfer, was developed in this study. Four compounds, 3-nitrophenol, 4-nitrophenol, 3,4-dinitrophenol, and 2,4-dichlorophenol, were used as model compounds to be preconcentrated from water samples. The extraction involved filling a 2-cm length of hollow fiber with 4 muL of acceptor solution using a conventional microsyringe, followed by impregnation of the pores of the fiber wall with 1-octanol. The fiber was then immersed in 4 mL of aqueous sample solution. The analytes in the sample solution were extracted into the organic solvent and then back-extracted into the acceptor solution. During extraction, the acceptor phase was repeatedly moved in and out of the hollow fiber channel and the syringe controlled by a syringe pump. Separation and quantitative analyses were then performed by using high-performance liquid chromatography. The results indicated that up to 400-fold enrichment of the analytes could be obtained under the optimized conditions. The enrichment factors were two times those of static liquid-liquid-liquid microextraction. Good repeatabilities (RSD values below 9.30%) were obtained. The calibration linear range was from 10 to 1000 ng/mL with the square of the correlation coefficient (r2) >0.9916. Detection limits were in the range of 0.45-0.98 ng/mL. In addition, as compared with the previously reported dynamic three-phase microextraction in which there was no relative movement between the acceptor and the organic phase (which is not conducive to effective mass transfer), this new method shows much higher extraction efficiency. All these results suggest that this new dynamic LLLME/AMAP technique could be a better alternative to the previous LLLME for the extraction of analytes from aqueous samples.

Journal Article↗

Method based on solid-phase microextraction--high-performance liquid chromatography with UV and electrochemical detection to determine estrogenic compounds in water samples.

We determined a group of estrogenic compounds by solid-phase microextraction (SPME) coupled to high-performance liquid chromatography (HPLC) with both ultraviolet (UV) and electrochemical detection (ED). A modified liquid chromatograph was used. Polyacrylate fibers (85 microns) were used to extract the analytes from the aqueous samples. Dynamic and static modes of desorption were compared and the variables affecting both absorption and desorption processes in SPME-HPLC were optimized. Static desorption gave the best recoveries and peak shapes. The performance of the SPME-HPLC-UV-ED method was checked with river water and wastewater. The method enabled estrogenic compounds to be determined at low-microgram l-1 levels in real water samples. Limits of detection were between 0.3 and 1.1 micrograms l-1 using UV detection and between 0.06 and 0.08 microgram l-1 using ED. beta-Estradiol was found in samples from a wastewater treatment plant at concentrations between 1.9 and 2.2 micrograms l-1.

Chromatography, High Pressure Liquid↗

Analysis of biogenic amines by solid-phase microextraction and high-performance liquid chromatography with electrochemical detection.

We investigated the new solid-phase microextraction method by high-performance liquid chromatography with electrochemical detection for the analysis of biogenic amines. The Carbowax-Templated Resin 50 microm (purple) fibre coating offers good performances for dopamine and serotonin separation, i.e., good selectivity and high sensibility (0.1 microg l(-1)). We also tested this fibre for biogenic amines quantification of rat striatum. The coating seems to be selective towards the amines and has low affinity for the metabolites, allowing a good separation and preventing drawbacks from the biological matrix. These first results obtained using this original separation method offer large perspectives of application to many biological samples.

Animals↗

Monolithic silica column for in-tube solid-phase microextraction coupled to high-performance liquid chromatography.

In-tube solid-phase microextraction (SPME) has successfully been coupled to capillary LC, and further an automated in-tube SPME system has been developed using a commercially available HPLC auto-sampler. However, an open tubular capillary column with a thick film of polymer (stationary phase) is unfavorable because the ratio of the surface area of coating layer contacted with sample solution to the volume of the capillary column is insufficient for mass transfer. A highly efficient SPME column is. therefore, required. We introduced a C18-bonded monolithic capillary column that was used for in-tube SPME. The column consisted of continuous porous silica having a double-pore structure. Both the through-pore and the meso-pore were optimized for in-tube SPME, and the optimized capillary column was connected to an HPLC injection valve for characterization. The results demonstrated that the pre-concentration efficiency is excellent compared with the conventional in-tube SPME. The novel method for both introduction and concentration of the samples was effective. satisfactory and suitable for use in the SPME medium.

Chromatography, High Pressure Liquid↗

Coupling solid-phase microextraction and high-performance liquid chromatography for direct and sensitive determination of halogenated fungicides in wine.

A solid-phase microextraction (SPME) method coupled to high-performance liquid chromatography with diode array detection (HPLC-DAD) for the analysis of six organochlorine fungicides (nuarimol, triadimenol, triadimefon, folpet, vinclozolin and penconazole) in wine was developed. For this purpose, polydimethylsiloxane-divinylbenzene-coated fibers were utilized and all factors affecting throughput, precision, and accuracy of the SPME method were investigated and optimized. These factors include: matrix influence, extraction and desorption time, percentage of ethanol, pH, salt effect and desorption mode. The performed analytical procedure showed detectability ranging from 4 to 27 microg l(-1) and precision from 2.4 to 14.2% (as intra-day relative standard deviation, RSD) and 4.7-25.7% (as inter-day RSD) depending on the fungicide. The results demonstrate the suitability of the SPME-HPLC-DAD method to analyze these organochlorine fungicides in red wine.

Chromatography, High Pressure Liquid↗

[Determination of trace chrysene in environmental water by solid-phase microextraction coupled with high performance liquid chromatography].

A rapid method for the determination of trace chrysene in environmental water by solid-phase microextraction (SPME) coupled with high performmnce liquid chromatography (HPLC) was developed. The experimental conditions of SPME, such as extraction time, extraction temperature, effect of ion strength, desorption time, desorption solution, desorption mode and the analytical conditions of HPLC were optimized. The optimal conditions were room temperature, 1,100 r/min of stirring rate, 30 min of extraction time, 3 min of desorption time, and methanol as the desorption solution. Methanol was used as the mobile phase on a C18 reversed phase chromatographic column. The flow rate was 1 mL/min. The detection wavelength was 266 nm on a UV-Vis detector. The linear range was from 0.013 microgram/L to 3.0 micrograms/L, the detection limit was 2.7 ng/L, and the relative standard deviation (RSD) was 5.6%. The method was used for the determination of trace chrysene in tap water, mineral water, rain water and river water. The recoveries were from 103.2% to 119.3%, the RSDs were from 4.8% to 10.2%. The method is fast, convenient, sensitive, solvent-free, and suitable for the determination of trace chrysene in environmental water.

Chromatography, Gas↗

Application of a static solid-phase microextraction procedure combined with liquid-liquid extraction to determine poly(dimethyl)siloxane-water partition coefficients for selected polychlorinated biphenyls.

A static solid-phase microextraction (SPME) procedure combined with liquid-liquid extraction (LLE) was used to determine the poly(dimethyl)siloxane (PDMS)-water partition coefficients (K(f)) for selected polychlorinated biphenyl congeners (PCBs), including PCB 1, 15, 28, 47, 101, 153, 180, 202, 206, and 209. The accuracy for the measurements of analyte concentrations in the aqueous phase was ensured with a one-to-one recovery correction strategy employing one 13C-labeled PCB congener as a surrogate standard for each unlabeled PCB counterpart. The effects of coating thickness (7, 30, and 100 microm) and sample volume (130 mL and 2 L) on the K(f) values were examined experimentally and confirmed with paired t-tests. Significant dependence of K(f) values on coating thickness was found for a few heavily chlorinated congeners only, and was tentatively attributed to the use of the inaccurate effective coating volumes and the structural variation with these PDMS coatings. In addition, no significant differences in the log K(f) values of all analytes except for PCB 206 were found between the sample sizes of 130 mL and 2 L for both the 7- and 100-microm coatings. Overall, K(f) values obtained with 2-L sample containers were consistently higher than those reported in the literature, which is attributable to the selection of appropriate equilibrium times for SPME and direct measurements of aqueous analyte concentrations with LLE in the present study.

Dimethylpolysiloxanes↗

Poly(methacrylic acid-ethylene glycol dimethacrylate) monolith in-tube solid phase microextraction coupled to high performance liquid chromatography and analysis of amphetamines in urine samples.

In-tube solid-phase microextraction (SPME) based on a poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column was investigated for the extraction of amphetamine, methamphetamine and their methylenedioxy derivatives. The monolithic capillary column showed high extraction efficiency towards target analytes, which could be attributed to its larger loading amount of extraction phase than conventional open-tubular extraction capillaries and the convective mass transfer procedure provided by its monolithic structure. The extraction mechanism was studied, and the results indicated that the extraction process of the target analytes was involved with hydrophobic interaction and ion-exchange interaction. The polymer monolith in-tube SPME-HPLC system with UV detection was successfully applied to the determination of amphetamine, methamphetamine and their methylenedioxy derivatives in urine samples, yielding the detection limits of 1.4 - 4.0 ng/mL. Excellent method reproducibility (RSD < 2.9%) was found over a linear range of 0.05-5 microg/mL, and the time for the whole analysis was only approximately 25 min. The monolithic capillary column was reusable in coping with the complicated urine samples.

Adsorption↗