Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Pentachlorophenol”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

Levels of PCDDs, PCDFs, and PCBs in the blood of the non-occupationally exposed residents living in the vicinity of a chemical plant in the Czech Republic.

In 2003, concentrations of altogether 17 PCDD/Fs congeners and 12 non-ortho and mono-ortho dioxin-like PCBs were measured in the blood of 60 randomly selected adults who lived in three settlements surrounding a chemical plant that had been producing chlorinated herbicides (mainly HCHs, HCB, pentachlorophenole, 2,4,5-T) in the 1960's; subjects consuming home-produced animal foods were chosen. Twenty blood donors with similar characteristics from the locality with about 80 km distance were used as control subjects. The factors that influenced the dioxin levels were investigated on the basis of a questionnaire. The aim of our study was to find out whether the residents living in the surroundings of the chemical plant are at a greater exposure risk than the controls. To calculate TEQ values, WHO-TEFs were used. The concentrations of four PCDD and six PCDF congeners were below the LOD in more than 50% of samples. Significantly higher WHO-TEQ levels (p<0.05) were found for PCDDs, PCDFs, or PCBs in all three followed up groups compared with controls. The geometric means of the total TEQ values for PCDD/F/PCBs were 43.8, 50.2, and 40.0 pg/g fat compared to 23.2 pg/g fat in the control. The percentages of TEQ due to the measured congeners in exposed groups were 9-10.3% for PCDDs, 20.5-26.9% for PCDFs, 19.2-23.1% for coplanar and 43.6-47.2% for mono-ortho PCBs. In control, the percentage of TEQ was 11.6, 26.7, 24.1, and 37.5%. PCBs, predominantly PCB156, followed by PCB126 contributed 60 to 70% of the total TEQ value. Positive correlation of the PCDD/PCDF/PCB blood levels with age and with consumption of locally produced eggs was found.

Adult↗

Transformation of phenol, catechol, guaiacol and syringol exposed to sodium hypochlorite.

Germs, xenobiotics and organic matter that influence the colour, turbidity and organoloeptic properties of water are removed by chlorination. Unfortunately, chlorine oxidants including sodium hypochlorite, used in water treatment induce processes that partly convert the treated compounds to unwanted chlorinated derivatives. The purpose of this work was to analyse the efficiency of transformation of phenol, catechol, guaiacol and syringol exposed to sodium hypochlorite and determine the intermediates formed during oxidative conversion of these compounds. The analysis was performed in aerobic conditions, both in acidic (pH 4.0) and alkaline (pH 8.0) medium. The effectiveness of transformation was slightly higher in acidic in comparison to alkaline conditions. Some chlorophenols, such as 2-chlorophenol, 2,4-dichlorophenol, 2,4,5-trichlorophenol and pentachlorophenol were determined as the products of phenol conversion. Chlorophenols were also formed during catechol, guaiacol and syringol transformation by replacement of hydroxy and methoxy residues by chlorine atoms. Moreover, some chlorocatechols and chlorinated methoxyphenols were determined during catechol and methoxyphenols transformations. Higher concentrations of chlorinated compounds were observed in the alkaline environment during phenol transformation. Conversion of catechol and methoxyphenols generated higher amounts of chlorinated intermediates in the acidic medium. In samples carboxylic acids like acetic and formic acids were determined. The formation of these compounds was the result of the cleavage of aromatic structure of phenols.

Catechols↗

Sequential photochemical-biological degradation of chlorophenols.

UV/TiO2/H2O2, UV/TiO2 and UV/H2O2 were compared as pre-treatment processes for the detoxification of mixtures of 4-chlorophenol (4CP), 2,4-dichlorophenol (DCP), 2,4,6-trichlorophenol (TCP) and pentachlorophenol (PCP) prior to their biological treatment. When each chlorophenol was initially supplied at 50 mg l(-1), UV/TiO2/H2O2 treatment supported the highest pollutant removal, COD removal, and dechlorination efficiencies followed by UV/TiO2 and UV/H2O2. The remaining toxicity to Lipedium sativum was similar after all pre-treatments. Chlorophenol photodegradation was always well described by a first order model kinetic (r2>0.94) and the shortest 4CP, DCP, TCP and PCP half-lives of 8.7, 7.1, 4.5 and 3.3 h, respectively, were achieved during UV/TiO2/H2O2 treatment. No pollutant removal was observed in the controls conducted with H2O2 or TiO2 only. Inoculation of all the photochemically pre-treated mixtures with activated sludge microflora was followed by complete removal of the remaining pollutants. Combined UV/TiO2/H2O2-biological supported the highest detoxification, dechlorination (99%) and COD removal (88%) efficiencies. Similar results were achieved when each chlorophenol was supplied at 100 mg l(-1). COD and Cl mass balances indicated UV, UV/H2O2, and UV/TiO2 treatments lead to the formation of recalcitrant photoproducts, some of which were chlorinated.

Bacteria↗

Polychlorinated dibenzo-p-dioxins and dibenzofurans in paddy soils and river sediments in Akita, Japan.

Paddy soils and sediments from the Yoneshirogawa, Omonogawa, and Koyoshigawa River Basins in Akita were analyzed for polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). The levels and compositions in those samples including soils from non-agricultural areas (non-agricultural soils) were investigated using isomer-specific analysis to determine characteristic sources. The PCDD/PCDF compositions in the samples were compared with respect to possible sources. The PCDD/PCDF concentrations in paddy soils were much higher than those in the non-agricultural soils and much higher than those found in other parts of Japan. Although PCDD/PCDFs were ubiquitous in sediments from river sources to mouths of the respective river basins, those concentrations were much lower than those from paddy soils and non-agricultural soils, and from other parts of Japan. Comparison of PCDD/PCDF homologues and isomer compositions for samples indicated that compositions of paddy soils and sediments, except for those from river sources, had similar characteristics to PCDD/PCDFs originating from impurities in herbicides, 2,4,6-trichlorophenyl 4-nitrophenyl ether (CNP) and pentachlorophenol (PCP), and that compositions of river-source sediments and non-agricultural soils resembled those of atmospheric depositions. Results of statistical analyses suggest that PCDD/PCDF contamination of paddy soils and sediments is attributable mainly to three sources: CNP, PCP, and atmospheric deposition. Results of this study also demonstrate that CNP and PCP are not only important contaminants of local areas of Japan, but that they exist throughout Akita, in northern Japan. We therefore conclude that PCDD/PCDF pollution caused by those compounds has a widespread influence on paddy soils and river sediments in Japan.

Benzofurans↗

Monitoring PCDD/Fs and other organic substances in workers of a hazardous waste incinerator: a case study.

The aim of this study was to measure, 6 years after regular operations, the concentrations of a number of organic substances in blood and urine of 19 workers employed at a hazardous waste incinerator (HWI) in Spain, and to establish the temporal variation with respect to baseline data and previously performed surveys. This facility was the first, and so far the only HWI in that country. The levels of hexachlorobenzene (HCB), polychlorinated biphenyls (PCB 28, 52, 101, 138, 153 and 180) and polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were analyzed in six composite plasma samples, while concentrations of di-, tri, and pentachlorophenols, as well those of 1-hydroxypyrene were measured in the urine of these workers. The current mean PCDD/F concentration, 10.4 ng I-TEQ/kg lipid, was significantly lower than that found in the baseline survey, 26.7 ng I-TEQ/kg lipid and similar to that found in the previous (2004) study (7.7 ng I-TEQ/kg lipid). PCDD/F levels in plasma were similar or even lower than those recently reported for various non-exposed populations. For the remaining analyzed substances in plasma and urine, there was not any significant increase in comparison with the levels found in the baseline survey. On the other hand, no marked differences between the concentrations of organic substances in plasma or urine were found according to the respective workplace (plant, laboratory and administration). The results of the present survey indicate that after 6 years of regular operation, the workers at the HWI are not occupationally exposed to PCDD/Fs and other organic substances in their workplaces.

Adult↗

Sequential treatment via Trametes versicolor and UV/TiO2/Ru(x)Se(y) to reduce contaminants in waste water resulting from the bleaching process during paper production.

An efficient sequential, biological and photocatalytic treatment to reduce the pollutant levels in wastewater due to the bleaching process during paper production is reported. For a biological pre-treatment, 800 ml of non-sterilized effluent was inoculated with Trametes versicolor immobilized in polyurethane foam, with 25 g l(-1) glucose, 6.75 mM CuSO(4), and 0.22 mM MnSO(4) added, and cultured at 25 degrees C with an air flow of 800 ml min(-1) for 8d. The fungus did not inhibit growth of the heterotropic populations of the effluent. After 4d of culture, the chemical oxygen demand (COD) reduction and colour removal (CR) were 82% and 80%, respectively, with laccase (LAC) and manganese peroxidase (MnP) activities of 345 U l(-1) and 78 U l(-1), respectively. The COD reduction and CR correlated positively (p<0.0001) with LAC and MnP activities. Chlorophenol removal was 99% of pentachlorophenol, 99% of 2,3,4,6-tetrachlorophenol (2,3,4,6-TCP), 98% of 3,4-dichlorophenol (3,4-DCP) and 77% of 4-chlorophenol (4-CP), while 2,4,5-trichlorophenol (2,4,5-TCP) increased to 0.2 mg l(-1). The pre-treated effluent was then exposed to a photocatalytic treatment. The treatment with photolysis resulted in 9% CR and 46% COD reduction, 42% CR and 60% COD reduction by photocatalysis, and 62% CR and 85% COD reduction by heterogeneous photocatalysis with the system TiO(2)/Ru(x)Se(y) (Fig. 4). With this treatment the bacterial and fungal populations also decreased by 5 logarithmic units with respect to the biological treatment alone (Fig. 5). The total sequential treatment resulted in a 92% CR (from 5800 UC), 97% COD reduction (from 59 g l(-1)) and 99% chlorophenol removal at 96 h and 20 min.

Biodegradation, Environmental↗

Stir bar sorptive extraction for the analysis of wine cork taint.

A magnetic stir bar with a polydimethylsiloxane coating was used to absorb 2,4,6-trichloroanisole, 2,3,4,5-tetrachloroanisole, pentachloroanisole and their respective phenols from synthetic and real wine samples. The stir bar sorptive extraction method was optimised to obtain the best extraction conditions in terms of temperature, time, pH and NaCl addition. The stir bar was desorbed in a thermal desorption system coupled to a gas chromatograph-mass spectrometer. The method proposed showed good linearity over the concentration range tested and correlation coefficients ranged from 0.96 to 0.99 for all the analytes. The reproducibility and repeatability of the method was estimated between 1.29 and 4.02%. With no a pre-concentration step and with a much reduced analysis time, all the analyzed compounds showed detection and quantification limits that were lower than those observed with other methods found in the bibliography. Except for pentachlorophenol due to its poor absorptivity in polydimethysiloxane, in red wines, LOD ranged between 7.56 and 61.56 pg/l, and LOQ ranged between 17.21 and 205.11 pg/l; while in white wines, the LOD ranged between 5.82 and 30.50 pg/l and LOQ ranged between 19.41 and 101.61 pg/l. These concentrations were always lower than their respective olfactory thresholds values.

Gas Chromatography-Mass Spectrometry↗

Trace analysis of phenolic xenoestrogens in water samples by stir bar sorptive extraction with in situ derivatization and thermal desorption-gas chromatography-mass spectrometry.

A method for the simultaneous measurement of trace amounts of phenolic xenoestrogens, such as 2,4-dichlorophenol (2,4-DCP), 4-tert-butyl-phenol (BP), 4-tert-octylphenol (OP), 4-nonylphenol (NP), pentachlorophenol (PCP) and bisphenol A (BPA), in water samples was developed using stir bar sorptive extraction (SBSE) with in situ derivatization followed by thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS) analysis. The conditions for derivatization with acetic acid anhydride were investigated. A polydimethylsiloxane (PDMS)-coated stir bar and derivatization reagents were added to 10 ml of water sample and stirring was commenced for 10-180 min at room temperature (25 degrees C) in a headspace vial. Then, the extract was analyzed by TD-GC-MS. The optimum time for SBSE with in situ derivatization was 90 min. The detection limits of 2,4-DCP, BP, OP, NP, PCP and BPA were 2, 1, 0.5, 5, 2 and 2 pg ml(-1), respectively. The method showed good linearity over the concentration ranges of 10, 5, 2, 20, 10 and 10-1000 pg ml(-1) for 2,4-DCP, BP, OP, NP, PCP and BPA, respectively, and the correlation coefficients were higher than 0.99. The average recoveries of those compounds in river water samples were equal to or higher than 93.9% (R.S.D. <7.2%) with correction using the added surrogate standards. This simple, accurate, sensitive and selective method can be used in the determination of trace amounts of phenolic xenoestrogens in river water samples.

Estrogens↗

Development of solid-phase extraction and solid-phase microextraction methods for the determination of chlorophenols in cork macerate and wine samples.

Tri-, tetra- and pentachlorophenol (TCP, TeCP and PCP) can be considered the precursors in the formation of corresponding chloroanisoles, known to be powerful odorants in corks and wine. Determining the presence of these chlorophenolic compounds in cork soaking solutions (ethanol/water mixtures, 12% (v/v) ethanol used for cork quality control testing), or in wine can be achieved by acetylation/gas chromatography electron-capture detection. In order to reach the required sensitivity, a previous preconcentration step is necessary. Solid-phase extraction (SPE) and headspace solid-phase microextraction (HS-SPME) have given good results for the preconcentration of TCP, TeCP and PCP in such matrices. The use of Oasis HLB cartridges gives acceptable recoveries for the three compounds when different volumes (50-250 mL) of cork macerate with concentrations ranging from 20 to 150 ng/L are processed. Preconcentration based on HS-SPME has also been optimised with a 100 microm polydimethylsiloxane fibre and in situ derivatization. The HS-SPME method allows chlorophenols in a cork soaking solution and in wine to be determined with a limit of detection of 1 ng/L for each compound (in cork macerate) and a repeatability of around 0.5%-5% (n=8) for a concentration level of 30 ng/L.

Chlorophenols↗

Determination of weakly acidic endocrine-disrupting compounds by liquid chromatography-mass spectrometry with post-column base addition.

A sensitive analytical method based on liquid chromatography-electrospray ionisation mass spectrometry (LC-ESI-MS) has been developed for the determination of seven endocrine-disrupting compounds: 4-n-nonylphenol (NP), 4-tert-butylphenol (t-BP), bisphenol A (BPA), 2,4-dichlorophenol (DCP), 2,4,5-trichlorophenol (TCP), pentachlorophenol (PCP) and 4-tert-butylbenzoic acid (BBA) in water samples. To achieve a good LC separation, acidification of the LC mobile phase was necessary, but this led to MS signal suppression for the less acidic compounds. In order to enhance the sensitivity for these analytes, post-column addition of different bases such as ammonia, trimethylamine, and 1,8-diazabicyclo-(5,4,0)undec-7-en (DBU) was evaluated. The post-column addition of base is proposed here to raise effluent pH, helping in the ionisation process of the compounds with higher pKa values (t-BP, BPA, DCP and NP). The use of DBU, diluted in MeOH, proved to be the most efficient post-column reagent for enhancing the MS signal. The signal-to-noise ratios for t-BP and NP increased by more than 200-fold and 35-fold, respectively, whereas for DCP and BPA an increase of about 10-fold was achieved. This strategy permitted direct determination of the seven compounds at low ppb levels. For application to real water samples, an extraction and preconcentration step using the solid-phase extraction (SPE) technique was carried out. The applicability of three solid-phase materials--Bond Elut C18, and two polymeric sorbents: LiChrolut EN and Oasis HLB--and the optimization of other SPE parameters such as the elution solvent and sample volume used, were studied in order to maximize extraction efficiency. Oasis HLB provided the best results, obtaining--with the proposed SPE procedure--satisfactory percentage recoveries for all compounds (70-110%) with the exception of NP, for which a recovery of 54% was achieved. Application of the whole method, SPE-LC-(ESI)-MS, to natural waters permitted low nanogram-per-liter determination of all seven compounds.

Acids↗

Development of a multiresidue method for analyzing herbicide and fungicide residues in bovine milk based on solid-phase extraction and liquid chromatography-tandem mass spectrometry.

This report describes a liquid chromatography (LC)-tandem mass spectrometry (MS) multiresidue method for determining traces of 30 base/neutral/acid herbicides and fungicides in bovine whole milk. Four milliliters of milk was spiked with the analytes and two surrogate analytes (SAs) and then diluted with 35 mL of a water/methanol solution (50:50, v/v). This mixture was passed through a 0.5-g Carbograph 4 cartridge. After washings, analytes were re-extracted by back-flushing the cartridge with 1.5 mL of methanol followed by 6 mL of methylene chloride/methanol (80:20, v/v), 50 mmol/L formic acid. After partial solvent removal down to about 0.1, 0.15 mL of 1 mmol/L formic acid aqueous solution and an internal standard (IS) were added. After filtration, 50 microL of the final extract was then introduced into the LC analytical column. During the chromatographic run, the MS system was operated in both positive and negative ion modes. MS data acquisition was performed in the multi-reaction monitoring mode, selecting two precursor ion>product ion transitions for each target compound, except for pentachlorophenol. On analyzing six milk samples from different sources, absolute recovery of the analytes and the two SAs ranged between 78% and 104% with RSDs not larger than 13%. The accuracy of the method at three different spike levels was assessed by adding the two SAs to analyte-containing milk samples and varied between 82% and 120% with RSDs not larger than 11%. Limits of quantification were estimated to range between 0.008 and 1.4 microg/L. Compared to the Carbograph 4 cartridge, one filled with a N-vinylpyrrolidone-m-divinylbenzene co-polymer (Oasis HLB) sorbent was much less efficient in recovering several of the acidic herbicides considered and, in addition, its relative final extract produced a severe negative matrix effect that drastically weakened ion signal intensities of several non acidic analytes.

Animals↗

Ion chromatography-atmospheric pressure chemical ionization mass spectrometry for the determination of trace chlorophenols in clam tissues.

A novel analytical method has been developed for the determination of 14 trace chlorophenols in clam tissues by ion chromatography (IC) coupled with atmospheric pressure chemical ionization mass spectrometry (APCI-MS) in the negative mode. The method comprised a fast ultrasound-assisted extraction using a mixture of methanol/water (4:1v/v) containing 5% triethylamine (TEA) as extraction solvent, solid-phase extraction with an Oasis HLB cartridge and gradient separation using KOH/acetonitrile at a flow rate of 1.0 mL/min on an IonPac AG11 guard column (50 mm x 4.0 mm I.D.) and an IonPac AS11 analytical column (250 mm x 4.0 mm I.D.). The molecular ions m/z [M-H](-) 127, 129; 161, 163; 195, 197 and 263, 265, 267 were selected for quantification in the selected ion monitoring (SIM) mode for monochlorophenols (MCPs), dichlorophenols (DCPs), trichlorophenols (TCPs) and pentachlorophenol (PCP), respectively. The average recoveries of the objective compounds spiked in clam tissues were between 80.2% and 98.2%. Within-day and day-to-day relative standard deviations were less than 12.6% and 13.2%, respectively. The optimum IC-APCI-MS conditions were successfully applied to the analyses of 14 trace chlorophenols in clam tissues.

Animals↗

Separation of carbon nanotubes in aqueous medium by capillary electrophoresis.

A robust and reproducible method for the dispersion of carbon nanotubes, either single-walled or multi-walled is presented. Dispersion of nanotubes was achieved as surfactant-coated species of sodium dodecyl sulphate. The addition of small amounts of hydroxypropyl methyl cellulose (HPMC) together with the surfactant, sodium dodecyl sulphate, was found critical to achieve reproducible nanotubes dispersion and to obtain an homogeneous and stable solution. This solution is further analyzed by capillary electrophoresis using a background electrolyte solution containing a polymer, 0.025% (w/v) HPMC solution prepared in 5 mM ammonium acetate at pH 8.03. This electrophoretic method presents a high reproducibility between runs, being an interesting alternative to study nanotube size distribution or characterization after synthesis. In addition, the methodology developed allowed the study of the interaction of the different types of carbon nanotubes with a molecular probe such as pentachlorophenol. This procedure was showed effective to detect small differences on the chemical/physical surface properties of the nanotubes. The different interaction behavior found within the two SWNTs selected was critically discussed.

Electrophoresis, Capillary↗

Multiple response optimisation based on desirability functions of a microwave-assisted extraction method for the simultaneous determination of chloroanisoles and chlorophenols in oak barrel sawdust.

A microwave-assisted extraction (MAE) method was optimised for extracting 2,4,6-trichloroanisole (TCA), 2,3,4,6-tetrachloroanisole (TeCA), pentachloroanisole (PCA), 2,4,6-trichlorophenol (TCP), 2,3,4,6-tetrachlorophenol (TeCP) and pentachlorophenol (PCP) from oak barrels. The method was optimised by using a central composite experimental design with extraction time, temperature and solvent volume as influential parameters. A desirability function was then employed in addition to the simultaneous optimisation of the compounds. The optimal conditions identified were temperature 130 degrees C, solvent volume 35 mL and extraction time 50 min. The compounds were determined by gas chromatography with electron-capture detection. MAE was compared with conventional Soxhlet extraction; the results obtained with MAE were in good agreement with those obtained by Soxhlet extraction.

Anisoles↗

Rapid, one-pot derivatization and distillation of chlorophenols from solid samples with their on-line enrichment.

A microwave-assisted steam distillation (MASD) sample preparation technique for extracting chlorophenols from solid samples was studied. This open vessel microwave system based study developed as an integrated method since it has incorporated extractive distillation, derivatization and on-line enrichment. Gas chromatography (GC) with electron-capture detection was used for the analysis. The study involved optimization of MASD parameters and on-line enrichments using spiked solid samples. MASD achieved recoveries for spiked soil samples in the range of 94-101% within 20min with a collection of only 20ml distillate facilitating on-line enrichment. Some real samples were analyzed that included soil, wood, leather, textiles, dyes and certified reference materials of soil and wood samples. Limit of detection values of 12ng/g for pentachlorophenol and 194ng/g for monochlorophenol were found. Recoveries of 96.6% in the case of soil certified reference material (CRM) with RSD 2.7% and 80.6% in the case of wood CRM with RSD 3.3% were observed in this study. MASD studied found to produce very clean extracts in comparison to reference techniques.

Chemical Fractionation↗

Establishing the feasibility of coupled solid-phase extraction-solid-phase derivatization for acidic herbicides.

The significance of this research is that it improves analytical methodology used for organic chemicals in aqueous solutions by establishing the feasibility of heterogeneous chemical derivatization at the liquid-solid interface (i.e., solid-phase reaction or solid-phase derivatization). A solid-phase derivatization method for determining chlorinated herbicide acids was developed. Solid-phase extraction was used to concentrate and retain analytes on sorbents for subsequent solid-phase derivatization. Background interferences were removed from the chromatograms by electronically subtracting the responses of blank, nonfortified analyses from spiked samples. Two extraction sorbents (octadecyl bonded silica and polystyrene-divinylbenzene) and two derivatizing reagents (BF3-MeOH and trimethylsilyldiazomethane) were investigated. Recovery of 13 chlorinated herbicide acids--including pentachlorophenol, dinoseb, and bentazon (having a derivatizable functional group, -OH or -NH, bonded directly to a phenyl group); dicamba, picloram, acifluorfen, 3,5-dichlorobenzoic acid, and dacthal (having a derivatizable functional group, -COOH, bonded directly to a phenyl group); and 2,4-D, 2,4,5-T, dichlorprop, 2,4,5-TP, and 2,4-DB (having a derivatizable functional group, -COOH, bonded directly to a sp3 carbon atom)--was tested. The analytical method developed was proven successful for determining acidic herbicides, except for the dacthal diacid metabolite, in aqueous samples.

Acids↗

Chemical analysis and genotoxicological safety assessment of paper and paperboard used for food packaging.

This study presents the research on the chemical analysis and genotoxicity of 28 virgin/recycled paper products in food-contact use. In the chemical analysis, paper products were extracted by reflux with ethanol, and analyzed by gas chromatography/mass spectrometry. 4,4'-bis(dimethylamino)benzophenone (Michler's ketone: MK), 4,4'-bis(diethylamino)benzophenone (DEAB), 4-(dimethylamino)benzophenone (DMAB) and bisphenol A (BPA) were found characteristically in recycled products. Seventy-five percent of the recycled paper products contained MK (1.7-12 microg/g), 67% contained DEAB (0.64-10 micro g/g), 33% contained DMAB (0.68-0.9 microg/g) and 67% contained BPA (0.19-26 microg/g). Although, BPA was also detected in virgin paper products, the detection levels in the recycled products were ten or more times higher than those in the virgin products. The genotoxicity of paper and paperboard extracts and compounds found in them were investigated by Rec-assay and comet assay. Of the 28 products tested by Rec-assay using Bacillus subtilis, 13 possessed DNA-damaging activity. More recycled than virgin products (75% against 25%) exhibited such activity, which, of the compounds, was observed in BPA, 1,2-benzisothiazoline-3-one (BIT), 2-(thiocyanomethylthio)benzothiazole, 2,4,5,6-tetrachloro-isophthalonitrile, 2,4,6-trichlorophenol (TCP), and pentachlorophenol. The critical toxicant in one virgin paper product was concluded to be BIT. Eight samples with DNA-damaging activity were also tested by comet assay using HL-60 cells; six induced comet cells significantly (five times or higher than the control) without a decrease of viable cells. TCP, BZ, DEAB, and BIT also caused a slight increase in comet cells. In conclusion, we showed that most recycled paper products contain chemicals such as MK, DEAB, DMAB, and BPA, and possess genotoxicity. However, the levels of the chemicals in the recycled products could not explain their genotoxic effects.

Apoptosis↗

Quantification of phenolic metabolites of environmental chemicals in human urine using gas chromatography-tandem mass spectrometry and isotope dilution quantification.

We have developed a method to measure 12 urinary phenolic metabolites of pesticides or related chemicals. The target chemicals for our method are 2-isopropoxyphenol; 2,4-dichlorophenol; 2,5-dichlorophenol; carbofuranphenol; 2,4,5-trichlorophenol; 2,4,6-trichlorophenol; 3,5,6-trichloro-2-pyridinol; para-nitrophenol, ortho-phenylphenol, pentachlorophenol, 1-naphthol and 2-naphthol. The sample preparation involves enzyme hydrolysis, isolation of the target chemicals using solid phase extraction cartridges, a phase-transfer catalyzed derivatization, cleanup using sorbent-immobilized liquid/liquid extraction cartridges, and concentration of the sample. Derivatized samples are analyzed by capillary gas chromatography-tandem mass spectroscopy using isotope dilution calibration for quantification. The limits of detection are in the mid ng/L range and the average coefficient of variation was below 15% for most of the analytes. Using our method, we measured concentrations of the target chemicals in urine samples from the general population.

Calibration↗